909 resultados para American-college
Resumo:
Purpose: The aim of this study was to evaluate the effectiveness of disinfectant solutions (1% sodium hypochlorite, 2% chlorhexidine digluconate, 2% glutaraldehyde, 100% vinegar, tabs of sodium perborate-based denture cleanser, and 3.8% sodium perborate) in the disinfection of acrylic resin specimens (n = 10/group) contaminated in vitro by Candida albicans, Streptococcus mutans, S. aureus, Escherichia coli, or Bacillus subtilis as measured by residual colony-forming unit (CFU). In a separate experiment, acrylic resin was treated with disinfectants to monitor potential effects on surface roughness, Ra (μm), which might facilitate microbial adherence. Materials and Methods: Three hundred fifty acrylic resin specimens contaminated in vitro with 1×10 6 cells/ml suspensions of standard strains of the cited microorganisms were immersed in the disinfectants for 10 minutes; the control group was not submitted to any disinfection process. Final counts of microorganisms per ml were performed by plating method for the evaluation of microbial level reduction. Results were compared statistically by ANOVA and Tukey's test (p ≤ 0.05). In a parallel study aiming to evaluate the effect of the tested disinfectant on resin surface, 60 specimens were analyzed in a digital rugosimeter before and after ten cycles of 10-minute immersion in the disinfectants. Measurements of superficial roughness, Ra (μm), were compared statistically by paired t-test (p ≤ 0.05). Results: The results showed that 1% sodium hypochlorite, 2% glutaraldehyde, and 2% chlorhexidine digluconate were most effective against the analyzed microorganisms, followed by 100% vinegar, 3.8% sodium perborate, and tabs of sodium perborate-based denture cleanser. Superficial roughness of the specimens was higher after disinfection cycles with 3.8% sodium perborate (p = 0.03) and lower after the cycles with 2% chlorhexidine digluconate (p = 0.04). Conclusion: Within the limits of this experiment, it could be concluded that 1% sodium hypochlorite, 2% glutaraldehyde, 2% chlorexidine, 100% vinegar, and 3.8% sodium perborate are valid alternatives for the disinfection of acrylic resin. © 2008 by The American College of Prosthodontists.
Resumo:
Purpose: To detect the occurrence and expression of the suppressor gene p53 and of the oncogene c-Myc in eyelid tumors of dogs using the PCR, RT-PCR, PCR-ELISA and RT-PCR-ELISA techniques. These genes have not been described in dog eyelid tumors before. Methods: Nine samples of eyelid or third eyelid epithelial tumors were obtained from the archives of the Department of Veterinary Pathology. Tumor diagnosis was confirmed by evaluation of hematoxylin-eosin stained sections, and immunohistochemistry for cytokeratin AE1/AE3 and vimentin V9. A canine mammary tumor was used for positive control. Agarose gel electrophoresis, PCR-ELISA and RT-PCR-ELISA were used to detect p53 and c-Myc genes. Results: The occurrence of p53 was detected in most of the eyelid tumors and third eyelid tumors studied (88.8%, n = 8) and was expressed in 75% of the positive samples, as indicated by ELISA. The c-Myc gene was found in 77.7% (n = 7) of the samples and was expressed in eight samples. Conclusions: Eyelid and third eyelid tumors of dogs express both the p53 and the c-Myc genes as shown by PCR and RT-PCR. However, PCR ELISA and RT-PCR ELISA were more efficient in assessing occurrence and expression of these genes because they identified amplified products that were not detected by agarose gel electrophoresis. © 2010 American College of Veterinary Ophthalmologists.
Resumo:
Purpose: To evaluate the shear bond strength and bond durability between a dual-cured resin cement (RC) and a high alumina ceramic (In-Ceram Alumina), subjected to two surface treatments. Materials and Methods: Forty disc-shaped specimens (sp) (4-mm diameter, 5-mm thick) were fabricated from In-Ceram Alumina and divided into two groups (n = 20) in accordance with surface treatment: (1) sandblasting by aluminum oxide particles (50 μm Al 2O 3) (SB) and (2) silica coating (30 μm SiO x) using the CoJet system (SC). After the 40 sp were bonded to the dual-cured RC, they were stored in distilled water at 37°C for 24 hours. After this period, the sp from each group were divided into two conditions of storage (n = 10): (a) 24 h-shear bond test 24 hours after cementation; (b) Aging-thermocycling (TC) (12,000 times, 5 to 55°C) and water storage (150 days). The shear test was performed in a universal test machine (1 mm/min). Results: ANOVA and Tukey (5%) tests noted no statistically significant difference in the bond strength values between the two surface treatments (p= 0.7897). The bond strengths (MPa) for both surface treatments reduced significantly after aging (SB-24: 8.2 ± 4.6; SB-Aging: 3.7 ± 2.5; SC-24: 8.6 ± 2.2; SC-Aging: 3.5 ± 3.1). Conclusion: Surface conditioning using airborne particle abrasion with either 50 μm alumina or 30 μm silica particles exhibited similar bond strength values and decreased after long-term TC and water storage for both methods. © 2011 by The American College of Prosthodontists.
Resumo:
Purpose: Staining of prosthodontic materials may result in patient dissatisfaction and additional expense for replacement. This study aimed to determine the color stability of two heat-cured denture base acrylic (Lucitone 550, Vipi Cril) and one nylon denture base resin (Transflex) after immersion in beverages. Materials and Methods: Forty disks of each resin (20.0-mm diameter, 3.0-mm thick) were prepared and stored in distilled water for 24 hours at 37°C. During that time (T 0), the color of all specimens was spectrophotometrically measured. Each specimen was immersed in coffee, cola, red wine, and distilled water as a means of control. After 15-day (T 1) and 30-day (T 2) periods of immersion, the color of the specimens was measured again. The CIE (Commission Internationale de L' Eclairage) L*a*b* system was used to determine mean ΔE (color changes) values for each material and compared statistically with two-way ANOVA and Bonferroni intervals at 0.95. Results: In ΔET 0T 1 and ΔET 0T 2 the most severe staining was apparent with red wine (p < 0.001), followed by coffee (p < 0.01), when compared to the specimens stored in distilled water. Transflex also showed significant color change after immersion in cola (p < 0.01). In ΔET 1T 2 only red wine promoted significant staining of all resins (p < 0.0001). Conclusion: Chromatic changes were exhibited by specimens immersed in red wine, followed by coffee. For Transflex, cola also promoted color changes. The values of color changes converted to National Bureau of Standard units showed them to be perceivable to the human eye. © 2011 by the American College of Prosthodontists.
Resumo:
Objective To describe simultaneous pharmacokinetics (PK) and thermal antinociception after intravenous (IV), intramuscular (IM) and subcutaneous (SC) buprenorphine in cats. Study design Randomized, prospective, blinded, three period crossover experiment. Animals Six healthy adult cats weighing 4.1±0.5kg. Methods Buprenorphine (0.02mgkg-1) was administered IV, IM or SC. Thermal threshold (TT) testing and blood collection were conducted simultaneously at baseline and at predetermined time points up to 24hours after administration. Buprenorphine plasma concentrations were determined by liquid chromatography tandem mass spectrometry. TT was analyzed using anova (p<0.05). A pharmacokinetic-pharmacodynamic (PK-PD) model of the IV data was described using a model combining biophase equilibration and receptor association-dissociation kinetics. Results TT increased above baseline from 15 to 480minutes and at 30 and 60minutes after IV and IM administration, respectively (p<0.05). Maximum increase in TT (mean±SD) was 9.3±4.9°C at 60minutes (IV), 4.6±2.8°C at 45minutes (IM) and 1.9±1.9°C at 60minutes (SC). TT was significantly higher at 15, 60, 120 and 180minutes, and at 15, 30, 45, 60 and 120minutes after IV administration compared to IM and SC, respectively. IV and IM buprenorphine concentration-time data decreased curvilinearly. SC PK could not be modeled due to erratic absorption and disposition. IV buprenorphine disposition was similar to published data. The PK-PD model showed an onset delay mainly attributable to slow biophase equilibration (t1/2ke0=47.4minutes) and receptor binding (kon=0.011mL ng-1minute-1). Persistence of thermal antinociception was due to slow receptor dissociation (t1/2koff=18.2minutes). Conclusions and clinical relevance IV and IM data followed classical disposition and elimination in most cats. Plasma concentrations after IV administration were associated with antinociceptive effect in a PK-PD model including negative hysteresis. At the doses administered, the IV route should be preferred over the IM and SC routes when buprenorphine is administered to cats. © 2012 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesiologists.
Resumo:
Purpose: Adhesive cementation is an important step for restorations made of feldspathic ceramic as it increases the strength of such materials. Incorrect selection of the adhesive resin and the resin cement to adhere to the ceramic surface and their durability against aging can affect the adhesion between these materials and the clinical performance. This study evaluated the effect of adhesive resins with different pHs, resin cements with different polymerization modes, and aging on the bond strength to feldspathic ceramic. Materials and Methods: One surface of feldspathic ceramic blocks (VM7) (N = 90) (6.4 × 6.4 × 4.8 mm3) was conditioned with 10% hydrofluoric acid for 20 seconds, washed/dried, and silanized. Three adhesive resins (Scotchbond Multi-Purpose Plus [SBMP], pH: 5.6; Single Bond [SB], pH: 3.4; and Prime&Bond NT [NT], pH: 1.7) were applied on the ceramic surfaces (n = 30 per adhesive). For each adhesive group, three resin cements with different polymerization modes were applied (n = 10 per cement): photo-polymerized (Variolink II base), dual polymerized (Variolink II base + catalyst), and chemically polymerized (C&B). The bonded ceramic blocks were stored in water (37°C) for 24 hours and sectioned to produce beam specimens (cross-sectional bonded area: 1 ± 0.1 mm2). The beams of each block were randomly divided into two conditions: Dry, microtensile test immediately after cutting; TC, test was performed after thermocycling (12,000×, 5°C to 55°C) and water storage at 37°C for 150 days. Considering the three factors of the study (adhesive [3 levels], resin cement [3 levels], aging [2 levels]), 18 groups were studied. The microtensile bond strength data were analyzed using 3-way ANOVA and Tukey's post hoc test (α= 0.05). Results: Adhesive resin type (p < 0.001) and the resin cement affected the mean bond strength (p= 0.0003) (3-way ANOVA). The NT adhesive associated with the chemically polymerized resin cement in both dry (8.8 ± 6.8 MPa) and aged conditions (6.9 ± 5.9 MPa) presented statistically lower bond strength results, while the SBMP adhesive resin, regardless of the resin cement type, presented the highest results (15.4 to 18.5 and 14.3 to 18.9 MPa) in both dry and aged conditions, respectively (Tukey's test). Conclusion: Application of a low-pH adhesive resin onto a hydrofluoric acid etched and silanized feldspathic ceramic surface in combination with chemically polymerized resin cement did not deliver favorable results. The use of adhesive resin with high pH could be clinically advised for the photo-, dual-, and chemically polymerized resin cements tested. © 2012 by the American College of Prosthodontists.
Resumo:
This paper presents a novel approach to the computed assessment of a mammographic phantom device. The approach shown here is fully automated and is based on the automatic selection of the region of interest, in the use of the discrete wavelet transform (DWT) and morphological operators to assess the quality of the American College of Radiology (ACR) mammographic phantom images. The algorithms developed here have succesfully scored 30 images obtained with different combinations of voltage applied to the tube and exposure and could notice the differences in the radiographs due to the different level of exposure to radiation. © 2013 Springer-Verlag.
Resumo:
Purpose: The objectives of this study were to investigate the flexural strength (FS) and chemical interaction between 2-tert-butylaminoethyl methacrylate (TBAEMA) and a denture base acrylic resin. Materials and Methods: Specimens were divided into five groups according to the concentration of TBAEMA incorporated in acrylic resin Onda-Cryl (0%, 1%, 2%, 3%, 4%) and were submitted to Fourier transform infrared spectroscopy (FTIR), electron spectroscopy for chemical analysis (XPS-ESCA), and differential scanning calorimetry (DSC) analyses. FS of the specimens was tested, and results were analyzed by ANOVA/Tukey's test (α < 0.05). Results: Different nitrogen ratios were observed on specimens' surfaces: 0.36%, 0.54%, 0.35%, and 0.20% for groups 1%, 2%, 3%, and 4%, respectively. FTIR indicated copolymerization of acrylic resin and TBAEMA, and DSC results demonstrated a decrease in glass transition temperature (Tg). Significant differences were found for FS (p < 0.05). The mean values were 91.1 ± 5.5,A 77.0 ± 13.1,B 67.2 ± 12.5,B 64.4 ± 13.0,B and 67.2 ± 5.9B MPa for groups 0%, 1%, 2%, 3% and 4%, respectively (same superscript letters indicate no significant difference). Conclusions: The incorporation of TBAEMA in acrylic resin resulted in copolymerization and the presence of amine groups on specimens' surfaces, and in decreases of Tg and FS. © 2012 by the American College of Prosthodontists.
Resumo:
This article describes an alternative two-step ocular prosthesis impression technique that employs two materials of different consistencies. The method is intended to provide better adaptation to underlying tissues, increased mobility of the prosthesis owing to improvements in facial contours, and improved esthetics, as well as offering the patient greater comfort and security. These advantages and this prosthesis' relative ease of fabrication mean it should be considered as the first step in the management of untreated anophthalmic sockets. © 2012 by the American College of Prosthodontists.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.
Resumo:
Objective To describe the technique of deep anterior lamellar keratoplasty (DALK) with Descemet's membrane (DM) exposure in horse eyes. Also, to compare the efficacy and safety of viscodissection and big-bubble techniques for DALK. Animals studied Thirty-four ex vivo horse eyes. Procedure Deep anterior lamellar keratoplasty was performed in 34 ex vivo horse eyes. Two groups (Group V - viscodissection - 2% sodium hyaluronate; Group A - air - big-bubble) of 17 eyes were studied. Other than the substance used, the surgical technique was similar for both groups. Nonperforated eyes were submitted for light microscopic histologic evaluation and scanning electron microscopic (SEM) analysis. Results Group V - Perforations occurred in 18% of the eyes during surgery. Light microscopy revealed exposure of DM in 28% of the eyes with mean thickness of the remaining stroma being 70.4μm. Group A - Perforations occurred in 42% of the eyes. Light microscopy revealed exposure of DM in 60% of the eyes with mean thickness of the remaining stroma being 23.3μm. No significant differences in safety, efficacy and thickness of the remaining stroma (including all eyes or excluding those with DM exposure) were observed. SEM of the surgical site revealed a more even surface in those eyes with DM exposure compared to eyes with thicker remaining stroma in both groups. Conclusions We describe two DALK techniques (viscodissection and big-bubble) for use in horses. No significant differences in safety, efficacy and thickness of the remaining stroma were observed. However, a nonsignificant trend toward the big-bubble technique being more efficacious but less safe was observed. © 2012 American College of Veterinary Ophthalmologists.
Resumo:
Objective: The objective of this study was to assess the use of analgesics, describe the attitudes of Brazilian veterinarians towards pain relief in horses and cattle and evaluate the differences due to gender, year of graduation and type of practice. Study design: Prospective survey. Methods: Questionnaires were sent to 1000 large animal veterinarians by mail, internet and delivered in person during national meetings. The survey investigated the attitudes of Brazilian veterinarians to the recognition and treatment of pain in large animals and consisted of sections asking about demographic data, use of analgesic drugs, attitudes to pain relief and to the assessment of pain. Descriptive statistics were used to analyze frequencies. Simple post hoc comparisons were performed using the chi-square test. Results: Eight hundred questionnaires were collected, but 87 were discarded because they were incomplete or blank. The opioid of choice for use in large animals was butorphanol (43.4%) followed by tramadol (39%). Flunixin (83.2%) and ketoprofen (67.6%) were the most frequently used NSAIDs by Brazilian veterinarians. Respondents indicated that horses received preoperative analgesics for laparotomy more frequently (72.9%) than cattle (58.5%). The most frequently administered preoperative drugs for laparotomy in horses were flunixin (38.4%) and xylazine (23.6%), whereas the preoperative drugs for the same surgical procedure in cattle were xylazine (31.8%) and the local administration of lidocaine (48%). Fracture repair was considered the most painful surgical procedure for both species. Most veterinarians (84.1%) believed that their knowledge in this area was not adequate. Conclusions and clinical relevance: Although these Brazilian veterinarians thought that their knowledge on recognition and treatment of pain was not adequate, the use of analgesic in large animals was similar in Brazil to that reported in other countries. © 2013 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Purpose: The purpose of this study was to evaluate the effect of diamond-like carbon thin films doped and undoped with silver nanoparticles coating poly(methyl methacrylate) (PMMA) on Candida albicans biofilm formation. The control of biofilm formation is important to prevent oral diseases in denture users. Materials and Methods: Forty-five PMMA disks were obtained, finished, cleaned in an ultrasonic bath, and divided into three groups: Gc, no surface coating (control group); Gdlc, coated with diamond-like carbon film; and Gag, coated with diamond-like carbon film doped with silver nanoparticles. The films were deposited using a reactive magnetron sputtering system (physical vapor deposition process). The specimens were characterized by optical profilometry, atomic force microscopy, and Rutherford backscattering spectroscopy analyses that determined differences in chemical composition and morphological structure. Following sterilization of the specimens by γ-ray irradiation, C. albicans (ATCC 18804) biofilms were formed by immersion in 2 ml of Sabouraud dextrose broth inoculated with a standardized fungal suspension. After 24 hours, the number of colony forming units (cfu) per specimen was counted. Data concerning biofilm formation were analyzed using ANOVA and the Tukey test (p < 0.05). Results: C. albicans biofilm formation was significantly influenced by the films (p < 0.00001), reducing the number of cfu, while not affecting the roughness parameters (p > 0.05). The Tukey test showed no significant difference between Gdlc and Gag. Films deposited were extremely thin (∼50 nm). The silver particles presented a diameter between 60 and 120 nm and regular distribution throughout the film surface (to Gag). Conclusion: Diamond-like carbon films, doped or undoped with silver nanoparticles, coating the base of PMMA-based dentures could be an alternative procedure for preventing candidosis in denture users. © 2013 by the American College of Prosthodontists.