594 resultados para 1081
Resumo:
Propolis obtained from honeybee hives has been widely used in medicine, cosmetics, and industry due to its versatile biological activities (antioxidant, antimicrobial, fungicidal, antiviral, antiulcer, immunostimulating, and cytostatic). These activities are mainly attributed to the presence of flavonoids in propolis, which points out the interest in quantifying these constituents in propolis preparations, as well as validation of analytical methodologies. High-performance liquid chromatography (HPLC) methods have been reported to quantify isolated flavonoids or these compounds in complex biological matrices, such as herbal raw materials and extractive preparations. An efficient, precise, and reliable method was developed for quantification of propolis extractive solution using HPLC with UV detection. The chromatograms were obtained from various gradient elution systems (GES) tested in order to establish the ideal conditions for the analysis of propolis extractive solution, using methanol and water: acetonitrile (97.5 : 2.5, v/v) as mobile phase. Gradient reversed phase chromatography was performed using a stainless steel column (250 x 4.6 mm i.d., 5 mum) filled with Chromsep RP 18 (Varian), column temperature at 30.0 +/- 0.1degreesC and detection at 310 nm. The main validation parameters of the method were also determined. The method showed linearity for chrysin in the range 0.24-2.4 mug mL(-1) with good correlation coefficients (0.9975). Precision and accuracy were determined. The obtained results demonstrate the efficiency of the proposed method. The analytical procedure is reliable and offers advantages in terms of speed and cost of reagents.
Resumo:
Simple and rapid procedures were developed for the quantification of amfepramone hydrochloride and diazepam and mazindol and diazepam in tablets using high performance liquid chromatography (HPLC) with UV detection. These techniques provided conditions for the separation of each active ingredient from the complex matrices of the dosage forms by dilution or extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (70:10:20, v/v/v) as a mobile phase, Radial-Pak C-18 column (100 x 8 mm id, 4 mu m), a column temperature of 25+/-1 degrees C and detection at 255 nm. The calibration curves were linear over a wide concentration range (100-1000 mu g.mL(-1) to amfepramone hydrochloride and mazindol and 10-100 mu g.mL(-1) to diazepam) with good correlation factors of 0.9978, 0.9956 and 0.9997 for amfepramone hydrochloride, mazindol, and diazepam, respectively.Mean recoveries obtained from the two kinds of samples ranged from 83.2 to 102.5%, with coefficients of variation ranging from 1.0 to 6.1.These results demonstrated the efficiency of the proposed methods, as well as advantages such as simplicity and short duration of analysis.
Resumo:
Liposomes of soya phosphatidylcholine, cholesterol, and stearylamine (molar ratio 6/3/1) and 0.1% alpha-tocopherol were prepared by the extrusion of multilamellar vesicles through 0.2-mu m polycarbonate membrane. Liposomes were characterized by electron transmission microscopy, and the mean structure diameter was 278 nm. The encapsulation efficiency obtained was 12.73%. The topical anti-inflammatory effect was evaluated in vivo by the cotton pellet granuloma method. We analyzed free piroxicam at 4 mg/kg, piroxicam encapsulated in liposomes added to 1.5% hydroxyethylcellulose (HEC) gel at 1.6 mg/kg, and piroxicam encapsulated in liposomes added to HEC gel at 4 mg/kg; the inhibition of inflammation obtained was 21.1%, 32.8%, and 47.4%, respectively. These results showed that the encapsulation of piroxicam produced an increase of topical anti-inflammatory effect, suggesting that the inhibition of inflammation can be obtained with lower drug concentrations.
Resumo:
Three sets of non-singular canonical variables for the rotational motion are analyzed. These sets are useful when the angle between z-axis of a coordinate system fixed in artificial satellite ( here defined by the directions of principal moments of inertia of the satellite) and the rotational angular momentum vector is zero or when the angle between Z-inertial axis and rotational angular momentum vector is zero. The goal of this paper is to compare all these sets and to determine the benefits of their uses. With this objective, the dynamical equations of each set were derived, when mean hamiltonian associate with the gravity gradient torque is included. For the torque-free rotational motion, analytical solutions are computed for symmetrical satellite for each set of variables. When the gravity gradient torque is included, an analytical solution is shown for one of the sets and a numerical solution is obtained for one of the other sets. By this analysis we can conclude that: the dynamical equation for the first set is simple but it has neither clear geometrical nor physical meaning; the other sets have geometrical and physical meaning but their dynamical equations are more complex.
Resumo:
The main target here is to determine the orbit of an artificial satellite, using signals of the GPS constellation and least squares algorithms implemented through sequential Givens rotations as a method of estimation, with the aim of improving the performance of the orbit estimation process and, at the same time, minimizing the computational procedure cost. Geopotential perturbations up to high order and direct solar radiation pressure were taken into account. It was also considered the position of the GPS antenna on the satellite body that, lately, consists of the influence of the satellite attitude motion in the orbit determination process. An application has been done, using real data from the Topex/Poseidon satellite, whose ephemeris is available at Internet. The best accuracy obtained in position was smaller than 5 meters for short period (2 hours) and smaller than 28 meters for long period (24 hours) orbit determination. In both cases, the perturbations mentioned before were taken into consideration and the analysis occurred without selective availability on the signals measurements.
Resumo:
This paper presents a hybrid way mixing time and frequency domain for transmission lines modelling. The proposed methodology handles steady fundamental signal mixed with fast and slow transients, including impulsive and oscillatory behaviour. A transmission line model is developed based on lumped elements representation and state-space techniques. The proposed methodology represents an easy and practical procedure to model a three-phase transmission line directly in time domain, without the explicit use of inverse transforms. The proposed methodology takes into account the frequency-dependent parameters of the line, considering the soil and skin effects. In order to include this effect in the state matrices, a fitting method is applied. Furthermore the accuracy of proposed the developed model is verified, in frequency domain, by a simple methodology based on line distributed parameters and transfer function related to the input/output signals of the lumped parameters representation. In addition, this article proposes the use of a fast and robust analytic integration procedure to solve the state equations, enabling transient and steady-state simulations. The results are compared with those obtained by the commercial software Microtran (EMTP), taking into account a three-phase transmission line, typical in the Brazilian transmission system.
Resumo:
Introduction: To study the functional and hystological alterations in dog kidneys submitted to total ischemia for thirty minutes and the possible metoprolol protective action. Material and methods: Sixteen dogs anesthetized with sodium pentobarbital (SP) were studied and divided into two groups: G1-8 dogs submitted to left nephrectomy and right renal artery clamping for thirty minutes, and G2-8 dogs submitted to the same procedures of G1 and to the administration of 0.5 mg.kg(-1) metoprolol before ischemia. Attributes of renal function were studied. Results: There was acute tubular necrosis and a decrease of renal blood flow and glomerular filtration, and a increase of renal vascular resistance in both groups. Conclusion: the thirty minute renal ischemia appears to have determined the alterations found in the renal function and hystology in both groups. Metoprolol, used in G2, as to the time and dose applied didn't protect the kidney from the ischemic episode.
Resumo:
Aim: To investigate the role of MMP-2 and MMP-9 in cardiac remodelling induced by tobacco smoke exposure in rats.Methods: Rats were allocated into two groups: C (n = 9): control animals; ETS (n = 9): exposed to tobacco smoke. After 4months, the animals underwent echocardiography, morphometric study and determination of MMP-2 and MMP-9 activity.Results: ETS rats had larger diastolic (C= 15.6 +/- 1.2 mm/kg, ETS = 18.0 +/- 0.9 mm/kg; p < 0.001) and systolic (C= 7.3 +/- 1.2 mm/kg, ETS = 9.2 0.9 mm/kg; p = 0.001) ventricular diameters adjusted for body weight. Fractional shortening (C= 53 +/- 4.8%, ETS = 48 +/- 3.3%; p = 0.031) and ejection fraction (C= 0. 89 +/- 0.03 5 ETS = 0. 86 +/- 0.02; p = 0.03 0) were smaller in the ETS group. Myocyte cross-sectional area (C= 245 8 mu m(2), ETS=253 8 mu m(2); p = 0.028) was higher in ETS rats. There were no differences in MNtP-2 (C=50 +/- 14%; ETS 43 +/- 11%, p 0.22 +/- 8) or MMP-9 (C=0.36 +/- 0.3%; ETS=0.62 +/- 0.3%, p=0.630) activity between the groups.Conclusion: MMP-2 and MMP-9 did not participate in the remodelling process induced by tobacco smoke exposure. (c) 2007 European Society of Cardiology. Published by Elsevier B.V. All rights reserved.
Resumo:
The left ventricular mass (LVM) measurement is of major importance for renal patients, as ventricular hypertrophy is an important prognostic index. The echo-cardiogram of the ventricular mass is larger before than it is after hemodialysis, which can confuse data interpretation. The aim of this work is to study the influence of alterations in fluid volume on the variations in measurements of ventricular mass observed during the course of a hemodialysis. Sixteen patients with chronic renal insufficiency in hemodialysis were evaluated at the Dialysis Unit of the University Hospital-UNESP, Botucatu, São Paulo State. The left ventricular mass was calculated from echocardiograms taken before and after hemodialysis and simultaneous ultra-filtration (12 patients: UF GROUP) and before and after hemodialysis isovolemic phase with sequential ultra-filtration (10 patients: ISO GROUP). Six of these patients were submitted to measurements of left ventricular mass before and after hemodialysis in both isovolemic and simultaneous ultra-filtration procedures. In the UF group, there was significant reduction in the following parameters before and after dialysis: diastolic diameter from 54.0 +/- 6.0 mm to 45.6 +/- 7.6 mm; left ventricular mass from 342 +/- 114 g to 265 +/- 117 g; and its respective index (IMVE) from 214 +/- 68 g/m(2) to 168 +/- 71 g/m(2). The ISO group showed no statistically significant variation. The behavior of the variables of six patients submitted to both observations confirm these results. In conclusion, the variations in echocardiogram measurements of the left ventricular mass relating to hemodialysis appear to be induced by alterations of the volemic condition.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: The purpose of this study was to histometrically evaluate the influence of photodynamic therapy on bone loss in furcation areas in rats with experimentally induced periodontal disease.Methods: Ligatures were placed on the first mandibular molar in rats. Then the animals were divided into four groups: control group = no treatment; methylene blue group (MB) = treated topically with methylene blue (100 mu g/ml); laser group (LLLT) = treated with low-level laser therapy; and photodynamic therapy group (PDT) = treated topically with MB followed by LLLT (4.5 J/cm(2)). Rats from all groups were sacrificed at 7, 15, or 30 days postoperatively. The area of bone loss in the furcation region of the first molar was histometrically analyzed. Data were analyzed statistically (analysis of variance and Bonferroni tests; P<0.05).Results: The PDT group demonstrated less bone loss compared to the other groups at 7 days (1.986 +/- 0.417 mm(2)); at 15 days, the PDT (1.641 +/- 0.115 mm(2)) and MB groups (1.991 +/- 0.294 mm(2)) demonstrated less bone loss compared to the control (4.062 +/- 0.416 mm(2)) and LLLT (2.641 +/- 0.849 mm(2)) groups.Conclusion: Within the parameters used in this study, PDT may be an effective alternative for control of bone loss in furcation areas in periodontitis.
Resumo:
Ties among event times are often recorded in survival studies. For example, in a two week laboratory study where event times are measured in days, ties are very likely to occur. The proportional hazards model might be used in this setting using an approximated partial likelihood function. This approximation works well when the number of ties is small. on the other hand, discrete regression models are suggested when the data are heavily tied. However, in many situations it is not clear which approach should be used in practice. In this work, empirical guidelines based on Monte Carlo simulations are provided. These recommendations are based on a measure of the amount of tied data present and the mean square error. An example illustrates the proposed criterion.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of the present study was to assess the spectral behavior of the erector spinae muscle during isometric contractions performed before and after a dynamic manual load-lifting test carried out by the trunk in order to determine the capacity of muscle to perform this task. Nine healthy female students participated in the experiment. Their average age, height, and body mass (± SD) were 20 ± 1 years, 1.6 ± 0.03 m, and 53 ± 4 kg, respectively. The development of muscle fatigue was assessed by spectral analysis (median frequency) and root mean square with time. The test consisted of repeated bending movements from the trunk, starting from a 45º angle of flexion, with the application of approximately 15, 25 and 50% of maximum individual load, to the stand up position. The protocol used proved to be more reliable with loads exceeding 50% of the maximum for the identification of muscle fatigue by electromyography as a function of time. Most of the volunteers showed an increase in root mean square versus time on both the right (N = 7) and the left (N = 6) side, indicating a tendency to become fatigued. With respect to the changes in median frequency of the electromyographic signal, the loads used in this study had no significant effect on either the right or the left side of the erector spinae muscle at this frequency, suggesting that a higher amount and percentage of loads would produce more substantial results in the study of isotonic contractions.
Resumo:
Verificou-se a influência de duas variedades de cana-de-açúcar (Saccharum spp.), incorparados em dieta artificial, na forma de colmos triturados, no desenvolvimento de Diatraea saccharalis (Fabr.) e no parasitismo de Cotesia flavipes (Cam.). A variedade SP71-1081 foi menos adequada ao desenvolvimento de D. saccharalis comparada à SP71-3146, aumentando os períodos larval e pupal (dias) e, diminuindo o peso larval; não houve diferenças para as viabilidades larval e pupal e peso de pupa. Lagartas oriundas das dietas artificiais e lagartas alojadas no interior dos toletes das variedades de cana, foram igualmente parasitadas por C. flavipes. Lagartas criadas em dieta artificial contendo colmos triturados das variedades testadas, promoveram desenvolvimento semelhante de C. flavipes. A percentagem de parasitismo foi semelhante nas larvas criadas em dietas artificiais contendo colmos das variedades SP 71 - 1081 (84,0%) e SP 71-3146 (81,3%).