86 resultados para ventilazione, VMC, IAQ,


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background/Aims: In an investigation of the functional impact of amblyopia on children, the fine motor skills, perceived self-esteem and eye movements of amblyopic children were compared with that of age-matched controls. The influence of amblyogenic condition or treatment factors that might predict any decrement in outcome measures was investigated. The relationship between indirect measures of eye movements that are used clinically and eye movement characteristics recorded during reading was examined and the relevance of proficiency in fine motor skills to performance on standardised educational tests was explored in a sub-group of the control children. Methods: Children with amblyopia (n=82; age 8.2 ± 1.3 years) from differing causes (infantile esotropia n=17, acquired strabismus n=28, anisometropia n=15, mixed n=13 and deprivation n=9), and a control group of children (n=106; age 9.5 ± 1.2 years) participated in this study. Measures of visual function included monocular logMAR visual acuity (VA) and stereopsis assessed with the Randot Preschool Stereoacuity test, while fine motor skills were measured using the Visual-Motor Control (VMC) and Upper Limb Speed and Dexterity (ULSD) subtests of the Brunicks-Oseretsky Test of Motor Proficiency. Perceived self esteem was assessed for those children from grade 3 school level with the Harter Self Perception Profile for Children and for those in younger grades (preschool to grade 2) with the Pictorial Scale of Perceived Competence and Acceptance for Young Children. A clinical measure of eye movements was made with the Developmental Eye Movement (DEM) test for those children aged eight years and above. For appropriate case-control comparison of data, the results from amblyopic children were compared with age-matched sub-samples drawn from the group of children with normal vision who completed the tests. Eye movements during reading for comprehension were recorded by the Visagraph infra-red recording system and results of standardised tests of educational performance were also obtained for a sub-set of the control group. Results Amblyopic children (n=82; age 8.2 ± 1.7 years) performed significantly poorer than age-matched control children (n=37; age 8.3 ± 1.3 years) on 9 of 16 fine motor skills sub-items and for the overall age-standardised scores for both VMC and ULSD items (p<0.05); differences were most evident on timed manual dexterity tasks. The underlying aetiology of amblyopia and level of stereoacuity significantly affected fine motor skill performance on both items. However, when examined in a multiple regression model that took into account the inter-correlation between visual characteristics, poorer fine motor skills performance was only associated with strabismus (F1,75 = 5.428; p =0. 022), and not with the level of stereoacuity, refractive error or visual acuity in either eye. Amblyopic children from grade 3 school level and above (n=47; age 9.2 ± 1.3 years), particularly those with acquired strabismus, had significantly lower social acceptance scores than age-matched control children (n=52; age 9.4 ± 0.5 years) (F(5,93) = 3.14; p = 0.012). However, the scores of the amblyopic children were not significantly different to controls for other areas related to self-esteem, including scholastic competence, physical appearance, athletic competence, behavioural conduct and global self worth. A lower social acceptance score was independently associated with a history of treatment with patching but not with a history of strabismus or wearing glasses. Amblyopic children from pre-school to grade 2 school level (n=29; age = 6.6 ± 0.6 years) had similar self-perception scores to their age-matched peers (n=20; age = 6.4 ± 0.5 years). There were no significant differences between the amblyopic (n=39; age 9.1 ± 0.9 years) and age-matched control (n = 42; age = 9.3 ± 0.38 years) groups for any of the DEM outcome measures (Vertical Time, Horizontal Time, Number of Errors and Ratio (Horizontal time/Vertical time)). Performance on the DEM did not significantly relate to measures of VA in either eye, level of binocular function, history of strabismus or refractive error. Developmental Eye Movement test outcome measures Horizontal Time and Vertical Time were significantly correlated with reading rates measured by the Visagraph for both reading for comprehension and naming numbers (r>0.5). Some moderate correlations were also seen between the DEM Ratio and word reading rates as recorded by Visagraph (r=0.37). In children with normal vision, academic scores in mathematics, spelling and reading were associated with measures of fine motor skills. Strongest effect sizes were seen with the timed manual dexterity domain, Upper Limb Speed and Dexterity. Conclusions Amblyopia may have a negative impact on a child’s fine motor skills and an older child’s sense of acceptance by their peers may be influenced by treatment that includes eye patching. Clinical measures of eye movements were not affected in amblyopic children. A number of the outcome measures of the DEM are associated with objective recordings of reading rates, supporting its clinical use for identification of children with slower reading rates. In children with normal vision, proficiency on clinical measures of fine motor skill are associated with outcomes on standardised measures of educational performance. Scores on timed manual dexterity tasks had the strongest association with educational performance. Collectively, the results of this study indicate that, in addition to the reduction in visual acuity and binocular function that define the condition, amblyopes have functional impairment in childhood development skills that underlie proficiency in everyday activities. The study provides support for strategies aimed at early identification and remediation of amblyopia and the co-morbidities that arise from abnormal visual neurodevelopment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION There is evidence that the reduction of blood perfusion caused by closed soft tissue trauma (CSTT) delays the healing of the affected soft tissues and bone [1]. We hypothesise that the characterisation of vascular morphology changes (VMC) following injury allows us to determine the effect of the injury on tissue perfusion and thereby the severity of the injury. This research therefore aims to assess the VMC following CSTT in a rat model using contrast-enhanced micro-CT imaging. METHODOLOGY A reproducible CSTT was created on the left leg of anaesthetized rats (male, 12 weeks) with an impact device. After euthanizing the animals at 6 and 24 hours following trauma, the vasculature was perfused with a contrast agent (Microfil, Flowtech, USA). Both hind-limbs were dissected and imaged using micro-CT for qualitative comparison of the vascular morphology and quantification of the total vascular volume (VV). In addition, biopsy samples were taken from the CSTT region and scanned to compare morphological parameters of the vasculature between the injured and control limbs. RESULTS AND DISCUSSION While the visual observation of the hindlimb scans showed consistent perfusion of the microvasculature with microfil, enabling the identification of all major blood vessels, no clear differences in the vascular architecture were observed between injured and control limbs. However, overall VV within the region of interest (ROI)was  measured to be higher for the injured limbs after 24h. Also, scans of biopsy samples demonstrated that vessel diameter and density were higher in the injured legs 24h after impact. CONCLUSION We believe these results will contribute to the development of objective diagnostic methods for CSTT based on changes to the microvascular morphology as well as aiding in the validation of future non-invasive clinical assessment modalities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent 'Global Burden of Disease' studies have provided quantitative evidence of the significant role air pollution plays as a human health risk factor (Lim et al., The Lancet, 380: 2224–2260, 2012). Tobacco smoke, including second hand smoke, household air pollution from solid fuels and ambient particulate matter are among the top risks, leading to lower life expectancy around the world. Indoor air constitutes an environment particularly rich in different types of pollutants, originating from indoor sources, as well as penetrating from outdoors, mixing, interacting or growing (when considering microbes) under the protective enclosure of the building envelope. Therefore, it is not a simple task to follow the dynamics of the processes occurring there, or to quantify the outcomes of the processes in terms of pollutant concentrations and other characteristics. This is further complicated by limitations such as building access for the purpose of air quality monitoring, or the instrumentation which can be used indoors, because of their possible interference with the occupants comfort (due to their large size, noise generated or amount of air drawn). European studies apportioned contributions of indoor versus outdoor sources of indoor air contaminants in 26 European countries and quantified IAQ associated DALYs (Disability-Adjusted Life Years) in those countries (Jantunen et al., Promoting actions for healthy indoor air (IAIAQ), European Commission Directorate General for Health and Consumers, Luxembourg, 2011). At the same time, there has been an increase in research efforts around the world to better understand the sources, composition, dynamics and impacts of indoor air pollution. Particular focus has been directed towards the contemporary sources, novel pollutants and new detection methods. The importance of exposure assessment and personal exposure, the majority of which occurs in various indoor micro¬environments, has also been realized. Overall, this emerging knowledge has been providing input for global assessments of indoor environments, the impact of indoor pollutants and their science based management and control. It was a major outcome of recent international conferences that interdisciplinarity and especially a better colla¬boration between exposure and indoor sciences would be of high benefit for the health related evaluation of environmental stress factors and pollutants. A very good example is the combination of biomonitoring and indoor air, particle and dust analysis to study the exposure routes of semi volatile organic compounds (SVOCs). We have adopted the idea of combining the forces of exposure and indoor sciences for this Special Issue, identified new and challenging topics and have attracted colleagues who are top researchers in their field to provide their inputs. The Special Issue includes papers, which collectively present advances in current research topics and in our view, build the bridge between indoor and exposure sciences.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapid growth in the global population requires expansion of building stock, which in turn calls for increased energy demand. This demand varies in time and also between different buildings, yet, conventional methods are only able to provide mean energy levels per zone and are unable to capture this inhomogeneity, which is important to conserve energy. An additional challenge is that some of the attempts to conserve energy, through for example lowering of ventilation rates, have been shown to exacerbate another problem, which is unacceptable indoor air quality (IAQ). The rise of sensing technology over the past decade has shown potential to address both these issues simultaneously by providing high–resolution tempo–spatial data to systematically analyse the energy demand and its consumption as well as the impacts of measures taken to control energy consumption on IAQ. However, challenges remain in the development of affordable services for data analysis, deployment of large–scale real–time sensing network and responding through Building Energy Management Systems. This article presents the fundamental drivers behind the rise of sensing technology for the management of energy and IAQ in urban built environments, highlights major challenges for their large–scale deployment and identifies the research gaps that should be closed by future investigations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Indoor air quality is a critical factor in the classroom due to high people concentration in a unique space. Indoor air pollutant might increase the chance of both long and short-term health problems among students and staff, reduce the productivity of teachers and degrade the student’s learning environment and comfort. Adequate air distribution strategies may reduce risk of infection in classroom. So, the purpose of air distribution systems in a classroom is not only to maximize conditions for thermal comfort, but also to remove indoor contaminants. Natural ventilation has the potential to play a significant role in achieving improvements in IAQ. The present study compares the risk of airborne infection between Natural Ventilation (opening windows and doors) and a Split-System Air Conditioner in a university classroom. The Wells-Riley model was used to predict the risk of indoor airborne transmission of infectious diseases such as influenza, measles and tuberculosis. For each case, the air exchange rate was measured using a CO2 tracer gas technique. It was found that opening windows and doors provided an air exchange rate of 2.3 air changes/hour (ACH), while with the Split System it was 0.6 ACH. The risk of airborne infection ranged between 4.24 to 30.86 % when using the Natural Ventilation and between 8.99 to 43.19% when using the Split System. The difference of airborne infection risk between the Split System and the Natural Ventilation ranged from 47 to 56%. Opening windows and doors maximize Natural Ventilation so that the risk of airborne contagion is much lower than with Split System.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In -situ soils in gee-material spectrum might arise due to sedimentation or could be non-sedimentary residual formations. The inherent nature and diversity of geological processes involved in the soil formation stage itself are responsible for a wide variability in the in-situ state of the soil. In this paper the possibility of analyses to arrive at engineering parameters of residual soils with varied degrees of residual or acquired cementation by the use of physical and in-situ parameters normally determined in routine investigations, are examined. An Intrinsic State Line,(ISL), with reference to an intrinsic state parameter (e/e(L)) and its variation with effective stress for reconstituted clays has been developed for residual tropical soils of non-sedimentary origin. In relation to the Intrinsic State Line (ISL), the undisturbed state, e, the potential parameter, e(L), along with the overburden pressure data has been analyzed to identify the dominance of cementation or stress history or both in controlling the compressibility and strength behaviour of natural residual soil. The location of yield stress point in relation to the ISL, pre-, and post- yield stress, compression indices along the e- log sigma(v) path provide a simple means to the analysis of the compressibility characteristics of cemented soils for analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The primary approaches for people to understand the inner properties of the earth and the distribution of the mineral resources are mainly coming from surface geology survey and geophysical/geochemical data inversion and interpretation. The purpose of seismic inversion is to extract information of the subsurface stratum geometrical structures and the distribution of material properties from seismic wave which is used for resource prospecting, exploitation and the study for inner structure of the earth and its dynamic process. Although the study of seismic parameter inversion has achieved a lot since 1950s, some problems are still persisting when applying in real data due to their nonlinearity and ill-posedness. Most inversion methods we use to invert geophysical parameters are based on iterative inversion which depends largely on the initial model and constraint conditions. It would be difficult to obtain a believable result when taking into consideration different factors such as environmental and equipment noise that exist in seismic wave excitation, propagation and acquisition. The seismic inversion based on real data is a typical nonlinear problem, which means most of their objective functions are multi-minimum. It makes them formidable to be solved using commonly used methods such as general-linearization and quasi-linearization inversion because of local convergence. Global nonlinear search methods which do not rely heavily on the initial model seem more promising, but the amount of computation required for real data process is unacceptable. In order to solve those problems mentioned above, this paper addresses a kind of global nonlinear inversion method which brings Quantum Monte Carlo (QMC) method into geophysical inverse problems. QMC has been used as an effective numerical method to study quantum many-body system which is often governed by Schrödinger equation. This method can be categorized into zero temperature method and finite temperature method. This paper is subdivided into four parts. In the first one, we briefly review the theory of QMC method and find out the connections with geophysical nonlinear inversion, and then give the flow chart of the algorithm. In the second part, we apply four QMC inverse methods in 1D wave equation impedance inversion and generally compare their results with convergence rate and accuracy. The feasibility, stability, and anti-noise capacity of the algorithms are also discussed within this chapter. Numerical results demonstrate that it is possible to solve geophysical nonlinear inversion and other nonlinear optimization problems by means of QMC method. They are also showing that Green’s function Monte Carlo (GFMC) and diffusion Monte Carlo (DMC) are more applicable than Path Integral Monte Carlo (PIMC) and Variational Monte Carlo (VMC) in real data. The third part provides the parallel version of serial QMC algorithms which are applied in a 2D acoustic velocity inversion and real seismic data processing and further discusses these algorithms’ globality and anti-noise capacity. The inverted results show the robustness of these algorithms which make them feasible to be used in 2D inversion and real data processing. The parallel inversion algorithms in this chapter are also applicable in other optimization. Finally, some useful conclusions are obtained in the last section. The analysis and comparison of the results indicate that it is successful to bring QMC into geophysical inversion. QMC is a kind of nonlinear inversion method which guarantees stability, efficiency and anti-noise. The most appealing property is that it does not rely heavily on the initial model and can be suited to nonlinear and multi-minimum geophysical inverse problems. This method can also be used in other filed regarding nonlinear optimization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada à Universidade Fernando Pessoa como parte dos requisitos para obtenção do Grau de Mestre em Engenharia e Gestão Ambiental, ramo de Sistemas Industriais

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of sustainable assessment methods in the UK is on the rise, anticipating the future regulatory trajectory towards zero carbon by 2016. The indisputable influence of sustainable rating tools on UK building regulations conveys the importance of evaluating their effectiveness in achieving true sustainable design, without adversely effecting human health and wellbeing. This paper reviews indoor air-quality (IAQ) issues addressed by UK sustainable assessment tools, and the potential trade-offs between building energy conservation and IAQ. The barriers to effective adoption of IAQ strategies are investigated, including recommendations, suggestions, and future research needs. The review identified a fundamental lack of IAQ criteria in sustainable assessment tools aimed at the residential sector. The consideration of occupants’ health and well-being should be paramount in any assessment scheme, and should not be overshadowed or obscured by the drive towards energy efficiency. A balance is essential.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tem havido uma preocupação crescente com a qualidade do ar interior (QAI) nas escolas em muitos países. Muitos estudos epidemiológicos têm encontrado diferenças regionais entre ambientes interiores. Apesar da elevada incidência de asma e rinite na população infantil, praticamente nada se sabia sobre a QAI em escolas portuguesas. A percepção dos problemas de QAI é crucial para avaliar os riscos para a saúde e rendimento dos estudantes, e para sugerir meios de reduzir a exposição a poluentes indesejáveis. Neste estudo procurou-se obter as concentrações de poluentes de interesse em estabelecimentos de ensino do 1º ciclo de Lisboa e Aveiro, estimar o estado atual de casos de asma e rinite em escolas primárias da capital, avaliar a influência de diferentes materiais das salas de aula/construção e hábitos escolares na QAI, identificar potenciais fontes de poluentes nos interiores e exteriores das salas de aula e propor medidas mitigadoras. Catorze escolas de Lisboa foram visitadas para obter a caracterização física das construções em termos de estrutura, ventilação, materiais de acabamento, produtos de limpeza, densidade de ocupação e potenciais fontes interiores de poluição. Os estudantes foram questionados sobre os seus hábitos e sintomas respiratórios através de inquéritos do modelo ISAAC (International Study of Asthma and Allergies in Childhood). Durante a primavera, outono e inverno (2008-2010), nas salas de aula e pátios, foram monitorizados, por amostragem passiva, compostos orgânicos voláteis (COVs), carbonilos e dióxido de azoto (NO2). Foram também medidos parâmetros de conforto e níveis de microrganismos. Duas escolas localizadas, uma no centro da cidade e outra na região suburbana, em Aveiro foram estudadas em 2010. Parâmetros de conforto, microrganismos, COVs, NO2, material particulado (PM10) foram medidos no interior e no exterior de ambas escolas. Os iões solúveis, carbono orgânico e elementar (OC e EC), e compostos orgânicos presentes no material particulado foram subsequentemente analisados em laboratório. Uma medida mitigadora - fitoremediação - foi avaliada na escola do centro da cidade de Aveiro em 2011. Os resultados do estudo mostraram que a QAI é pior do que a do ar exterior. Em geral, os níveis de CO2 e dos bioaerosóis excederam os níveis máximos aceitáveis para o conforto dos ocupantes estipulado pelas regulamentações portuguesas. Quase todos os COVs e carbonilos identificados mostraram razões interior/exterior (I/E) maiores que uma unidade, o que demonstra a importante contribuição de fontes interiores em todas as escolas. As razões I/E das concentrações de NO2 nunca excederam a unidade. Os níveis interiores diários de PM10 foram sempre maiores que os exteriores, exceto nos fins de semana. Após a colocação de plantas numa das salas de aula, observou-se uma redução estatisticamente significativa nos níveis de CO2, COVs, carbonilos, PM10, OC, e dos iões nitrato, sulfato, amónia, cálcio e carbonato. A possível redução dos níveis de poluentes no interior após a colocação de plantas pode representar uma solução de baixo custo para reduzir a exposição a muitos compostos, melhorar o rendimento e aumentar o bem estar dos alunos e professores em sala de aula.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O desenvolvimento deste trabalho teve como objectivo a optimização de um sistema de climatização industrial, constituído por quatro centrais de climatização adiabáticas, que apresentam limitações de capacidade de arrefecimento, controlo e eficiência. Inicialmente foi necessária a pesquisa bibliográfica e recolha de informação relativa à indústria têxtil e ao processo de arrefecimento evaporativo. Numa fase posterior foram recolhidos e analisados os diversos dados essenciais à compreensão do binómio edifício/sistema de climatização, para a obtenção de possíveis hipóteses de optimização. Da fase de recolha de informações e dados, destaca-se, também, a realização de análises à qualidade do ar interior (QAI). As optimizações seleccionadas como passíveis de implementação, foram estudadas e analisadas com o auxílio do software de simulação energética dinâmica DesignBuilder e os resultados obtidos foram devidamente trabalhados e ajustados de modo a permitir uma assimilação amigável e de fácil interpretação das suas vantagens e desvantagens, tendo ainda sido objecto de estudo de viabilidade económica. A optimização proposta reflecte uma melhoria substancial das condições interiores ao nível da temperatura e humidade relativa, resultando, ainda assim, numa redução de consumos energéticos na ordem dos 23 % (490.337 kWh), isto é, uma poupança anual de 42.169 € aos custos de exploração e com um período de retorno de 1 ano e 11 meses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Qualidade do Ar Interior (QAI) é um fator de grande preocupação. A importância de manter um ambiente salubre é mais acentuada em estabelecimentos escolares (EE), tendo em conta, que no interior destes permanecem crianças durante um elevado período de tempo. É fundamental garantir uma boa QAI nos edifícios escolares, de forma a salvaguardar a saúde, o bem-estar e o conforto dos ocupantes, bem como, não comprometer o seu desempenho escolar. Recentemente, foram construídos novos edifícios escolares e alguns dos existentes foram alvo de obras de remodelação. Contudo, a crescente tendência em construir edifícios cada vez mais herméticos, com vista à diminuição dos gastos de energia, origina problemas como a reduzida ventilação dos espaços. Vários estudos têm demonstrado a influência das atividades de limpeza na QAI. No entanto, verifica-se que na maioria das escolas não existem ainda procedimentos de limpeza padronizados. A falta de instruções de trabalho e a ausência de formação às assistentes operacionais pode comprometer a eficácia dos procedimentos de higienização, o que poderá ter influência na QAI dos espaços. Este estudo teve como principal objetivo avaliar a QAI em escolas básicas de 1.º ciclo. Foram contemplados no estudo fatores como a tipologia do edifício, a ocupação das salas e as atividades de limpeza. Procedeu-se à caracterização dos EE e à monitorização de parâmetros ambientais, como a temperatura do ar, a humidade relativa, a velocidade do ar, o dióxido de carbono, o monóxido de carbono, as partículas, os microrganismos mesófilos totais e os fungos. Estes parâmetros foram avaliados nas salas com ocupação, sem ocupação e durante a implementação de um plano de higienização. A ventilação inadequada parece ser o fator que mais condiciona a QAI das salas de aula avaliadas. Registaram-se elevadas concentrações de dióxido de carbono e de microrganismos mesófilos totais, que parecem estar relacionados com a permanência dos ocupantes nos locais e com a falta de ventilação adequada dos espaços. A concentração de dióxido de carbono foi mais elevada em edifícios recentes. Os picos elevados na concentração de partículas parecem estar associados com as atividades dos ocupantes. Obtiveram-se concentrações menores de fungos e de microrganismos mesófilos totais ao longo da implementação do plano de higienização, o que poderá significar que os procedimentos de limpeza contribuem para reduzir os níveis de contaminação dos espaços interiores. No entanto, tendo em conta, que a concentração de microrganismos mesófilos totais permaneceu elevada, as operações de limpeza parecem não ser suficientes para garantir uma boa QAI. O aumento da ventilação dos espaços poderia contribuir significativamente para a melhoria da QAI dos espaços avaliados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A prática de exercício físico é considerado condição essencial para a manutenção de uma boa saúde. A faixa etária de frequentadores de ginásios inclui utentes desde os 8 aos 80 anos, incluindo assim os grupos mais sensíveis à poluição do ar interior. Embora exista legislação específica para ginásios, nomeadamente para as condições de implementação, a mesma é reduzida e não contempla a qualidade do ar interior (QAI). O objetivo geral deste estudo consistiu na avaliação da QAI de quatro ginásios existentes na área metropolitana do Porto. O período de amostragem realizou-se entre 2 de Maio e 20 de Junho 2014 e, após a caracterização dos ginásios, foram monitorizados os seguintes parâmetros: partículas ultrafinas (< 100 nm), matéria particulada suspensa no ar de frações PM1, PM2,5, PM4 e PM10, dióxido de carbono, monóxido de carbono, ozono, compostos orgânicos voláteis, formaldeído, temperatura ambiente e humidade relativa durante 24 h/dia em salas com diferentes actividades (sala de musculação e cardiofitness e sala de aulas de grupo). Os resultados da avaliação dos parâmetros físicos e químicos foram comparados com os limiares de proteção e margem de tolerância do Decreto-Lei nº 118/2013 de 20 de Agosto, a Portaria nº 353-A/2013 de 4 de Dezembro e o Diploma que regula a construção, instalação e funcionamento dos ginásios. Os poluentes com maiores níveis de excedência são o dióxido de carbono, compostos orgânicos voláteis e as partículas PM2,5. As excedências devem-se essencialmente à sobrelotação das salas, excesso de atividade física e ventilação insuficiente. A localização da instalação dos ginásios é também um fator de extrema importância, sendo recomendado que este se situe em local pouco influenciado pelo tráfego automóvel, assim como, afastado de locais de possível interferência devido às atividades presentes, como é o caso da restauração existente em centros comerciais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dissertação teve como finalidade a realização de uma Auditoria Energética e da Qualidade do Ar Interior ao edifício de serviços da Câmara Municipal de Vila Nova de Gaia. No intuito de alcançar esta finalidade foram seguidos, em todo o processo, os regulamentos em vigor até à presente data da dissertação, de apoio à especialidade, nomeadamente o Regulamento das Características de Comportamento Térmico dos Edifícios, Regulamento dos Sistemas Energéticos de Climatização em Edifícios e Regulamento dos Sistemas Energéticos de Climatização em Edifícios e da Qualidade do Ar Interior. Na análise à Qualidade do Ar Interior foram verificados quase todos os parâmetros impostos por lei, exceto os das bactérias e dos fungos. Para as substâncias como dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCOH) e radão, os valores em média foram iguais a 894 ppm, 1,23 ppm, 0,07 ppm, 0,01 ppm e 378 Bq/m3 e estavam dentro dos limites regulamentares (984 ppm, 10,7ppm, 0,10 ppm, 0,08 ppm e 400 Bq/m3). Para os compostos orgânicos voláteis (COVs) e partículas do tipo PM10, os valores respetivos foram em média de 0,70 ppm e 0,16 mg/m3 e estavam acima dos limites regulamentares (0,26 ppm, 0,15 mg/m3). Admite-se que existem fontes emissoras de COVs dentro do edifício e que, para uma adequação ao tipo de tratamento ou sugestão de melhoria, seria necessário realizar uma análise por cromatografia de forma a identificar os compostos em causa. As concentrações de PM10 mais elevadas explicam-se porque existe uma abertura direta desses espaços ao exterior e em alguns casos esta é permanente. A análise energética permitiu um levantamento de todos os consumos de energia elétrica do edifício, realizando deste modo a desagregação em percentagem de cada equipamento consumidor. Em paralelo e até para se poder realizar a certificação energética do edifício foi realizado um estudo de simulação térmica dinâmica recorrendo ao programa DesignBuilder v2. Criou-se um modelo do edifício que foi validado após simulação e comparação com o consumo elétrico do ano de referência (desvio de 2,78%). Pela simulação verificou-se que os maiores consumidores de energia são a iluminação interior e o sistema de arrefecimento e determinou-se os Indicadores de Eficiência Energética (IEE) Real (com correção climática) e Nominal com valores de 73,8 e 46,5 , respetivamente. Implementando as condições nominais de utilização e funcionamento no edifício, segundo o Regulamento dos Sistemas Energéticos de vi Climatização em Edifícios (RSECE), concluiu-se que a classe energética deste edifício é do tipo D. O valor do IEE nominal foi superior ao IEE referência de 35,5 , e o requisito legal não se verificou. Assim, foi necessário apresentar medidas para um plano de racionalização energética (PRE). Nas medidas estudadas de melhoria da eficiência energética (aplicação de películas solares, compensação do fator de potência, instalação de um sistema de minigeração fotovoltaico e aplicação de iluminação eficiente tanto no interior como no exterior do edifício) destaca-se a correção do fator de potência, pois o valor pago de energia reactiva em 2011 foi de cerca de 1500 €. Admitindo ser necessário redimensionar os condensadores e que o custo é 1.840,00 €, ter-se-á um retorno do investimento em 1,2 anos. Outra medida é a aplicação de películas solares nos envidraçados com um custo de 5.046,00 €, esta terá um período de retorno de 1 ano e uma poupança de 37,90 MWh/ano. Finalmente refere-se a instalação de reguladores de tensão e substituição de determinadas lâmpadas por LEDs na iluminação interior, que prevê uma poupança anual de 25 MWh/ano e um período de retorno do investimento de 3,7 anos.