901 resultados para splinted squared impression coping
                                
Resumo:
Four experiments tested the hypothesis that people who are concerned with impression management cope with stereotype threat through denial. Consistent with this hypothesis, temporary employees threatened by a stereotype of incompetence (Study 1) and hostel-dwelling older adults (Study 2) were more likely to deny incompetence if they were high in impression management. African Americans (Study 3) showed a similar pattern of denying cognitive incompetence, which emerged primarily when they were interviewed by a White experimenter and had attended a predominantly Black high school. In Study 4, White students who expected to take an IQ test and were threatened by a stereotype of being less intelligent than Asians were more likely to deny that intelligence is important if they were high in impression management.
                                
Resumo:
Purpose: The objective of this study was to evaluate and compare 3 impression techniques for osseointegrated implant transfer procedures.Materials and Methods: (1) Group Splinted with Acrylic Resin (SAR), impression with square copings splinted with prefabricated autopolymerizing acrylic resin bar; (2) Group Splinted with Light-Curing Resin (SLR), impression, with square copings splinted with prefabricated light-curing composite resin bar; (3). Group Independent Air-abraded (IAA), impression with independent square coping aluminum oxide air-abraded. Impression procedures were performed with polyether material, and the data obtained was compared with a control group. These were characterized by metal matrix (MM) measurement values of the implants inclination positions at 90 and 05 degrees in relation to the matrix surface. Readings of analogs and implant inclinations were assessed randomly through graphic computation AutoCAD software. Experimental groups angular deviation with MM were submitted to analysis of variance and means were compared through Tukey's test (P < 0.05).Results: There was no statistical significant difference between SAR and SLR experimental groups and MM for vertical and angulated implants. Group IAA presented a statistically significant difference for angulated implants.Conclusion: It was concluded within the limitations of this study, that SAR and SLR produced more accurate casts than IAA technique, which presented inferior results.
                                
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
                                
Resumo:
Different transfer impression techniques for implant-supported prostheses have been suggested to obtain a working cast. This article describes and illustrates clinical and laboratory pros-thodontic procedures to transfer implant positions with splinted transfer copings and without impression material to form a laboratory analog transfer template. With this technique, a preliminary cast is modified to place the analogs according to a corrected position and obtain the master cast. Although this technique does not record adjacent tissues, it is a simple procedure, less time consuming, and easily performed.
                                
Resumo:
Purpose: The aim of this study was to compare splinting techniques for impression copings of osseointegrated implants with different angulations.Materials and Methods: Replicas (N = 24) of a metal matrix (control) containing two implants at 90 degrees and 65 degrees in relation to the horizontal surface were obtained by using four impression techniques: Technique 1 (T1), direct technique with square copings without union in open trays; Technique 2 (T2), square copings splinted with dental floss and autopolymerizing acrylic resin; Technique 3 (T3), square copings splinted with dental floss and autopolymerizing acrylic resin, sectioned and splinted again with autopolymerizing acrylic resin; Technique 4 (T4), square copings splinted with prefabricated acrylic resin bar. The impression material was polyether. The replicas were individually scanned to capture the images, which were assessed in a graphic computation program. The program allowed the angulation between the bases of the replicas and the reading screws to be measured. The images of the replicas were compared with the matrix image (control), and the differences in angulations from the control image were calculated. The analysis of variance and the Tukey test for comparisons (p < 0.05) were used for statistical analysis.Results: All groups showed significant differences in the implant angulations in comparison with the control group (p < 0.05). Group T1 showed the highest difference (1.019 degrees) followed by groups T2 (0.747 degrees), T3 (0.516 degrees), and T4 (0.325 degrees), which showed the lowest angular alteration compared to the control group. There were significant differences between inclined and straight implants in all the groups, except in group T4.Conclusions: Based on the results, the splinting of pick-up impression copings is indicated for osseointegrated implant impressions. The square copings splinted with a prefabricated acrylic resin bar presented the best results among the pick-up impression techniques evaluated in this study.
                                
Resumo:
Purpose This in vitro study compared the dimensional accuracy of two impression techniques Duralay splinted impression copings (D) and metal splinted impression copings (M) for implant supported pros theses Materials and Methods A master cast with four parallel implant abutment analogs and a passive framework were fabricated Vinyl polysiloxane impression material was used for all impressions with a metal stock tray Two groups (D and M) were tested (n = 5) The measurement method employed was just one titanium screw tightened to the framework Each group s measurements were analyzed using software that received the images of a video camera coupled to a stereomicroscope at X100 magnification The results were analyzed statistically (t test) Results The mean values of abutment/framework interface gaps were master cast = 32 mu m (SD 2), group D = 165 mu m (SD 60), and group M = 69 mu m (SD 36) There was a statistically significant difference between the D and M groups (P <= 001) Conclusion Under the limitations of this study, it could be suggested that a more accurate working cast can be fabricated using metal splinted impression copings INT J ORAL MAXILLOFAC IMPLANTS 2010 25 1153-1158
                                
Resumo:
PURPOSE The study aims to evaluate three-dimensionally (3D) the accuracy of implant impressions using a new resin splinting material, "Smart Dentin Replacement" (SDR). MATERIALS AND METHODS A titanium model of an edentulous mandible with six implant analogues was used as a master model and its dimensions measured with a coordinate measuring machine. Before the total 60 impressions were taken (open tray, screw-retained abutments, vinyl polysiloxane), they were divided in four groups: A (test): copings pick-up splinted with dental floss and fotopolymerizing SDR; B (test): see A, additionally sectioned and splinted again with SDR; C (control): copings pick-up splinted with dental floss and autopolymerizing Duralay® (Reliance Dental Mfg. Co., Alsip, IL, USA) acrylic resin; and D (control): see C, additionally sectioned and splinted again with Duralay. The impressions were measured directly with an optomechanical coordinate measuring machine and analyzed with a computer-aided design (CAD) geometric modeling software. The Wilcoxon matched-pair signed-rank test was used to compare groups. RESULTS While there was no difference (p = .430) between the mean 3D deviations of the test groups A (17.5 μm) and B (17.4 μm), they both showed statistically significant differences (p < .003) compared with both control groups (C 25.0 μm, D 19.1 μm). CONCLUSIONS Conventional impression techniques for edentulous jaws with multiple implants are highly accurate using the new fotopolymerizing splinting material SDR. Sectioning and rejoining of the SDR splinting had no impact on the impression accuracy.
                                
Resumo:
Dental impression is an important step in the preparation of prostheses since it provides the reproduction of anatomic and surface details of teeth and adjacent structures. The objective of this study was to evaluate the linear dimensional alterations in gypsum dies obtained with different elastomeric materials, using a resin coping impression technique with individual shells. A master cast made of stainless steel with fixed prosthesis characteristics with two prepared abutment teeth was used to obtain the impressions. References points (A, B, C, D, E and F) were recorded on the occlusal and buccal surfaces of abutments to register the distances. The impressions were obtained using the following materials: polyether, mercaptan-polysulfide, addition silicone, and condensation silicone. The transfer impressions were made with custom trays and an irreversible hydrocolloid material and were poured with type IV gypsum. The distances between identified points in gypsum dies were measured using an optical microscope and the results were statistically analyzed by ANOVA (p < 0.05) and Tukey's test. The mean of the distances were registered as follows: addition silicone (AB = 13.6 µm, CD=15.0 µm, EF = 14.6 µm, GH=15.2 µm), mercaptan-polysulfide (AB = 36.0 µm, CD = 36.0 µm, EF = 39.6 µm, GH = 40.6 µm), polyether (AB = 35.2 µm, CD = 35.6 µm, EF = 39.4 µm, GH = 41.4 µm) and condensation silicone (AB = 69.2 µm, CD = 71.0 µm, EF = 80.6 µm, GH = 81.2 µm). All of the measurements found in gypsum dies were compared to those of a master cast. The results demonstrated that the addition silicone provides the best stability of the compounds tested, followed by polyether, polysulfide and condensation silicone. No statistical differences were obtained between polyether and mercaptan-polysulfide materials.
                                
Resumo:
Several impression materials are available in the Brazilian marketplace to be used in oral rehabilitation. The aim of this study was to compare the accuracy of different impression materials used for fixed partial dentures following the manufacturers' instructions. A master model representing a partially edentulous mandibular right hemi-arch segment whose teeth were prepared to receive full crowns was used. Custom trays were prepared with auto-polymerizing acrylic resin and impressions were performed with a dental surveyor, standardizing the path of insertion and removal of the tray. Alginate and elastomeric materials were used and stone casts were obtained after the impressions. For the silicones, impression techniques were also compared. To determine the impression materials' accuracy, digital photographs of the master model and of the stone casts were taken and the discrepancies between them were measured. The data were subjected to analysis of variance and Duncan's complementary test. Polyether and addition silicone following the single-phase technique were statistically different from alginate, condensation silicone and addition silicone following the double-mix technique (p < .05), presenting smaller discrepancies. However, condensation silicone was similar (p > .05) to alginate and addition silicone following the double-mix technique, but different from polysulfide. The results led to the conclusion that different impression materials and techniques influenced the stone casts' accuracy in a way that polyether, polysulfide and addition silicone following the single-phase technique were more accurate than the other materials.
                                
Resumo:
To investigate stress intensity and coping style in older people with mild Alzheimer`s disease. The potential risk assessment of a stress event and the devising of coping strategies are dependent on cognitive function. Although older individuals with Alzheimer`s disease present significant cognitive impairment, little is known about how these individuals experience stress events and select coping strategies in stress situations. Survey. A convenient sample of 30 cognitively healthy older people and 30 individuals with mild Alzheimer`s disease were given an assessment battery of stress indicators (Symptom Stress List, Cornell Scale for Depression in Dementia, State-Trait Anxiety Inventory), coping style (Jalowiec Coping Scale) and cognitive performance (mini-mental state exam) were applied in both groups. Statistical analysis of the data employed the Mann-Whitney test to compare medians of stress indicators and coping style, Fischer`s exact test to compare proportions when expected frequencies were lower than five, and Spearman`s correlation coefficient to verify correlation between coping style and cognitive performance. Both groups suffered from the same stress intensity (p = 0.254). Regarding coping styles, although differences were not statistically significant (p = 0.124), emotion-oriented coping was predominant in the patients with Alzheimer`s disease. However, those individuals displaying better cognitive performance in the Alzheimer`s disease group had selected coping strategies focused on problem solving (p = 0.0074). Despite a tendency for older people with Alzheimer`s disease to select escape strategies and emotional control, rather than attempting to resolve or lesser the consequences arising from a problem, coping ultimately depends on cognitive performance of the individual. The findings of this study provide information and data to assist planning of appropriate support care for individuals with Alzheimer`s disease who experience stress situations, based on their cognitive performance.
                                
Resumo:
Background/Aims: To investigate the association between cortisol levels, chronic stress and coping in subjects with amnestic-type mild cognitive impairment (aMCI). Methods: Cortisol levels were measured using morning saliva samples from 33 individuals with aMCI and from 41 healthy elderly. Chronic stress was evaluated with the Stress Symptoms List (SSL), whereas coping strategies were assessed using the Jalowiec Coping Scale. Results: aMCI subjects with high SSL scores presented higher cortisol levels (p = 0.045). Furthermore, aMCI subjects who employed emotion-focused coping had higher SSL scores (p = 0.023). Conclusion: The association between increased cortisol secretion, chronic stress and coping strategies may be modulated by the presence or absence of cognitive impairment, where memory deficit awareness constitutes an additional potential factor involved in high stress severity. Copyright (C) 2009 S. Karger AG, Basel
                                
Resumo:
The aim of the study was to test a revised conceptualization of the role of coping in adjustment to a low-control stressor-women's adjustment to a failed in vitro fertilization (NF) attempt. Data were collected prior to the IVF treatment (Time I) and twice after the failed NF attempt (1 to 2 weeks after finding out the results, n = 171, and fi weeks later, n = 139). Initial adjustment was assessed at Time I, whereas measures of coping and both self-report and partner ratings of adjustment were obtained at Times ? and 3. As predicted, escapist strategies and problem-management strategies (mainly at Time ?) were associated with poor adjustment, whereas problem-appraisal coping was associated with better adjustment., There was also support for the proposed positive relationship between adjustment and emotional approach coping (on self-report adjustment).
                                
Resumo:
Data pertaining to the reputations, self-concepts and coping strategies of thirty-one secondary school Volatile Solvent Users (VSUs), forty-four ex-VSUs, and forty-eight non-VSUs in the Perth Metropolitan area of Western Australia were obtained using the High School Student Activity Questionnaire. Findings revealed that significant differences between current VSUs, ex-VSUs, and non-VSUs were more attributable to factors of reputation enhancement than to factors of either self-concept or coping strategies. Current VSUs identified themselves as both having and wanting to have a more non-confronting reputation, and as admiring drug-related activities significantly more than both ex-VSUs and non-VSUs. Two coping variables were also found to be significant indicating that females use more nonproductive coping strategies and external coping strategies than males. No interaction effects were identified. The implications for drug education and further research are discussed.
                                
Resumo:
Objectives This study examines the direct and mediated effects of shift workers' coping strategies and social support on structural work-nonwork conflict and subjective health. Methods The participants were 172 registered female nurses, aged 21 to 40 years. They all worked full-time, on rapidly rotating, 8-hour shifts in metropolitan general hospitals. All the respondents completed a self-administered questionnaire requesting demographic information and data on sources of social support, work-nonwork conflict, and coping strategies. Results A path model with good fit (chi(2)=28.88, df=23, P>.23, CFI=0.97) demonstrated complex effects of social support and coping on structural work-nonwork conflict and health. Conclusions Structural work-nonwork conflict mediated the effects of social support from supervisors and emotionally expressive coping on psychological symptoms. Control of shifts mediated the effect of social support from supervisors on structural work-nonwork conflict. Disengagement coping had direct and mediated effects on psychological and physical health. However, it also had mediated effects, with the effect on psychological health being mediated by support from co-workers and the effect on physical symptoms being mediated by family support. Go-worker support mediated the effect of social support from supervisors on psychological symptoms. Overall, these findings support previous research and clarify the process by which coping strategies and social support affect structural work-nonwork conflict and health in shift work.
                                
 
                    