Resumo

PURPOSE The study aims to evaluate three-dimensionally (3D) the accuracy of implant impressions using a new resin splinting material, "Smart Dentin Replacement" (SDR). MATERIALS AND METHODS A titanium model of an edentulous mandible with six implant analogues was used as a master model and its dimensions measured with a coordinate measuring machine. Before the total 60 impressions were taken (open tray, screw-retained abutments, vinyl polysiloxane), they were divided in four groups: A (test): copings pick-up splinted with dental floss and fotopolymerizing SDR; B (test): see A, additionally sectioned and splinted again with SDR; C (control): copings pick-up splinted with dental floss and autopolymerizing Duralay® (Reliance Dental Mfg. Co., Alsip, IL, USA) acrylic resin; and D (control): see C, additionally sectioned and splinted again with Duralay. The impressions were measured directly with an optomechanical coordinate measuring machine and analyzed with a computer-aided design (CAD) geometric modeling software. The Wilcoxon matched-pair signed-rank test was used to compare groups. RESULTS While there was no difference (p = .430) between the mean 3D deviations of the test groups A (17.5 μm) and B (17.4 μm), they both showed statistically significant differences (p < .003) compared with both control groups (C 25.0 μm, D 19.1 μm). CONCLUSIONS Conventional impression techniques for edentulous jaws with multiple implants are highly accurate using the new fotopolymerizing splinting material SDR. Sectioning and rejoining of the SDR splinting had no impact on the impression accuracy.

Formato

application/pdf

Identificador

http://boris.unibe.ch/78402/1/In%20Vitro%20Implant%20Impression.pdf

Di Fiore, Adolfo; Meneghello, Roberto; Savio, Gianpaolo; Sivolella, Stefano; Katsoulis, Joannis; Stellini, Edoardo (2015). In Vitro Implant Impression Accuracy Using a New Photopolymerizing SDR Splinting Material. Clinical implant dentistry and related research, 17(Suppl 2), e721-e729. Blackwell 10.1111/cid.12321 <http://dx.doi.org/10.1111/cid.12321>

doi:10.7892/boris.78402

info:doi:10.1111/cid.12321

info:pmid:25782045

urn:issn:1523-0899

Idioma(s)

eng

Publicador

Blackwell

Relação

http://boris.unibe.ch/78402/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Di Fiore, Adolfo; Meneghello, Roberto; Savio, Gianpaolo; Sivolella, Stefano; Katsoulis, Joannis; Stellini, Edoardo (2015). In Vitro Implant Impression Accuracy Using a New Photopolymerizing SDR Splinting Material. Clinical implant dentistry and related research, 17(Suppl 2), e721-e729. Blackwell 10.1111/cid.12321 <http://dx.doi.org/10.1111/cid.12321>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed