972 resultados para solid sampling technique
Resumo:
In the work underlying this thesis solid-phase microextraction (SPME) was evaluated as a passive sampling technique for organophosphate triesters in indoor air. These compounds are used on a large scale as flame-retarding and plastizicing additives in a variety of materials and products, and have proven to be common pollutants in indoor air. The main objective of this work was to develop an accurate method for measuring the volatile fraction. Such a method can be used in combination with active sampling to obtain information regarding the vapour/particulate distribution in different indoor environments. SPME was investigated under both equilibrium and non-equilibrium conditions and parameters associated with these different conditions were estimated. In Paper I, time-weighted average (TWA) SPME under dynamic conditions was investigated in order to obtain a fast air sampling method for organophosphate triesters. Among the investigated SPME coatings, the absorptive PDMS polymer had the highest affinity for the organophosphate triesters and was consequently used in all further work. Since the sampling rate is dependent on the agitation conditions, the linear airflow rates had to be carefully considered. Sampling periods as short as 1 hour were shown to be sufficient for measurements in the ng-μg m-3 range when using a PDMS 100-μm fibre and a linear flow rate above 7 cm s-1 over the fibre. SPME under equilibrium conditions is rather time-consuming, even under dynamic conditions, for slowly partitioning compounds such as organophosphate triesters. Nevertheless, this method has some significant advantages. For instance, the limit of detection is much lower compared to 1 h TWA sampling. Furthermore, the sampling time can be ignored as long as equilibrium has been attained. In Paper II, SPME under equilibrium conditions was investigated and evaluated for organophosphate triester vapours. Since temperature and humidity are closely associated with the distribution constant a simple study of the effect of these parameters was performed. The obtained distribution constants were used to determine the air levels in a common indoor environment. SPME and parallel active sampling on filters yielded similar results, indicating that the detected compounds were almost entirely associated with the vapour phase To apply dynamic SPME method in the field a sampler device, which enables controlled linear airflow rates to be applied, was constructed and evaluated (Paper III). This device was developed for application of SPME and active sampling in parallel. A GC/PICI-MS/MS method was developed and used in combination with active sampling of organophosphate triesters in indoor air (Paper IV). The combination of MS/MS and the soft ionization achieved with methanol as reagent gas yielded high selectivity and detection limits comparable to those provided by GC with nitrogen-phosphorus detection (NPD). The method limit of detection, when sampling 1.5 m3 of air, was in the range 0.1-1.4 ng m-3. In Paper V, the developed MS method was used in combination with SPME for indoor air measurements. The levels detected in the investigated indoor environments range from a few ng to μg m-3. Tris(2-chloropropyl) phosphate was detected at a concentration as high as 7 μg m-3 in a newly rebuilt lecture room.
Resumo:
This is a review of direct analysis using solid sampling graphite furnace atomic absorption spectrometry. Greater emphasis is dedicated to sample preparation, sample homogeneity, calibration and its application to microanalysis and micro-homogeneity studies. The main advantages and some difficulties related to the applicability of this technique are discussed. A literature search on the application of solid sampling graphite furnace atomic absorption spectrometry in trace element determination in many kinds of samples, including biological, clinical, technological and environmental ones, is also presented.
Resumo:
Pollen counts from samples taken from storage pots throughout one year (from October to September) were adjusted by Tasei's volumetric correction coefficient for the determination of pollen sources exploited by two colonies of Nannotrigona testaceicornis in Sao Paulo, Brazil. The results obtained by this sampling technique for seven months (December to June) were compared with those from corbicula load samples taken within the same period. This species visited a large variety of plant species, but few of them were frequently used. As a rule, pollen sources that appeared at frequencies greater than 1% were found with both sampling methods and significant positive correlations (Spearman correlation coefficient) were found between their values. The pollen load sample data showed that N. testaceicornis gathered pollen throughout the external activity period.
Resumo:
This is a review of direct analysis using solid sampling graphite furnace atomic absorption spectrometry. Greater emphasis is dedicated to sample preparation, sample homogeneity, calibration and its application to microanalysis and micro-homogeneity studies. The main advantages and some difficulties related to the applicability of this technique are discussed. A literature search on the application of solid sampling graphite furnace atomic absorption spectrometry in trace element determination in many kinds of samples, including biological, clinical, technological and environmental ones, is also presented.
Resumo:
A survey of predominantly industrial silicon carbide has been carried out using Magic Angle Spinning nuclear magnetic resonance (MAS nmr); a solid state technique. Three silicon carbide polytypes were studied; 3C, 6H, and 15R. The 13C and 29 Si MAS nmr spectra of the bulk SiC sample was identified on the basis of silicon (carbon) site type in the d iff ere n t pol Y t Y pes • Out to 5.00 A fro mac en t r a lsi 1 i con (0 r carbon) atom four types of sites were characterized using symmetry based calculations. This method of polytype analysis was also considered, in the prelminary stages, for applications with other polytypic material; CdBr 2 , CdI 2 , and PbI 2 " In an attempt to understand the minor components of silicon carbide, such as its surface, some samples were hydrofluoric acid washed and heated to extreme temperatures. Basically, an HF removable species which absorbs at -110 ppm (Si0 2 ) in the 29 Si MAS nmr spectrum is found in silicon carbide after heating. Other unidentified peaks observed at short recycle delays in some 29 Si MAS nmr spectra are considered to be impurities that may be within the lattice. These components comprise less than 5% of the observable silicon. A Tl study was carried out for 29 Si nuclei in a 3C ii polytype sample, using the Driven Equilibrium Single-Pulse Observation of T1 (DESPOT) technique. It appears as though there are a number of nuclei that have the same chemical shift but different T1 relaxation times. The T1 values range from 30 seconds to 11 minutes. Caution has to be kept when interpreting these results because this is the first time that DESPOT has been used for solid samples and it is not likely in full working order. MAS nmr indicates that the 13C and 29 Si ~sotropic chemical shifts of silicon carbide appear to have a reciprocal type of relationship_ Single crystal nmr analysis of a 6H sample is accordance with this finding when only the resultant isotropic shift is considered. However, single crystal nmr also shows that the actual response of the silicon and carbon nuclear environment to the applied magnetic field at various angles is not at all reciprocal. Such results show that much more single crystal nmr work is required to determine the actual behavior of the local magnetic environment of the SiC nuclei.
Resumo:
Compared to other volatile carbonylic compounds present in outdoor air, formaldehyde (CH2O) is the most toxic, deserving more attention in terms of indoor and outdoor air quality legislation and control. The analytical determination of CH2O in air still presents challenges due to the low-level concentration (in the sub-ppb range) and its variation with sampling site and time. Of the many available analytical methods for carbonylic compounds, the most widespread one is the time consuming collection in cartridges impregnated with 2,4-dinitrophenylhydrazine followed by the analysis of the formed hydrazones by HPLC. The present work proposes the use of polypropylene hollow porous capillary fibers to achieve efficient CH2O collection. The Oxyphan (R) fiber (designed for blood oxygenation) was chosen for this purpose because it presents good mechanical resistance, high density of very fine pores and high ratio of collection area to volume of the acceptor fluid in the tube, all favorable for the development of air sampling apparatus. The collector device consists of a Teflon pipe inside of which a bundle of polypropylene microporous capillary membranes was introduced. While the acceptor passes at a low flow rate through the capillaries, the sampled air circulates around the fibers, impelled by a low flow membrane pump (of the type used for aquariums ventilation). The coupling of this sampling technique with the selective and quantitative determination of CH2O, in the form of hydroxymethanesulfonate (HMS) after derivatization with HSO3-, by capillary electrophoresis with capacitively coupled contactless conductivity detection (CE-(CD)-D-4) enabled the development of a complete analytical protocol for the CH2O evaluation in air. (C) 2008 Published by Elsevier B.V.
Resumo:
This thesis covers sampling and analytical procedures for isocyanates (R-NCO) and amines (R-NH2), two kinds of chemicals frequently used in association with the polymeric material polyurethane (PUR). Exposure to isocyanates may result in respiratory disorders and dermal sensitisation, and they are one of the main causes of occupational asthma. Several of the aromatic diamines associated with PUR production are classified as suspected carcinogens. Hence, the presence of these chemicals in different exposure situations must be monitored. In the context of determining isocyanates in air, the methodologies included derivatisation with the reagent di-n-butylamine (DBA) upon collection and subsequent determination using liquid chromatography (LC) and mass spectrometric detection (MS). A user-friendly solvent-free sampler for collection of airborne isocyanates was developed as an alternative to a more cumbersome impinger-filter sampling technique. The combination of the DBA reagent together with MS detection techniques revealed several new exposure situations for isocyanates, such as isocyanic acid during thermal degradation of PUR and urea-based resins. Further, a method for characterising isocyanates in technical products used in the production of PUR was developed. This enabled determination of isocyanates in air for which pure analytical standards are missing. Tandem MS (MS/MS) determination of isocyanates in air below 10-6 of the threshold limit values was achieved. As for the determination of amines, the analytical methods included derivatisation into pentafluoropropionic amide or ethyl carbamate ester derivatives and subsequent MS analysis. Several amines in biological fluids, as markers of exposure for either the amines themselves or the corresponding isocyanates, were determined by LC-MS/MS at amol level. In aqueous extraction solutions of flexible PUR foam products, toluene diamine and related compounds were found. In conclusion, this thesis demonstrates the usefulness of well characterised analytical procedures and techniques for determination of hazardous compounds. Without reliable and robust methodologies there is a risk that exposure levels will be underestimated or, even worse, that relevant compounds will be completely missed.
Resumo:
An increasing number of publications on the dried blood spot (DBS) sampling approach for the quantification of drugs and metabolites have been spurred on by the inherent advantages of this sampling technique. In the present research, a selective and sensitive high-performance liquid chromatography method for the concurrent determination of multiple antiepileptic drugs (AEDs) [levetiracetam (LVT), lamotrigine (LTG), phenobarbital (PHB)], carbamazepine (CBZ) and its active metabolite carbamazepine-10,11 epoxide (CBZE)] in a single DBS has been developed and validated. Whole blood was spotted onto Guthrie cards and dried. Using a standard punch (6 mm diameter), a circular disc was punched from the card and extracted with methanol: acetonitrile (3:1, v/v) containing hexobarbital (Internal Standard) and sonicated prior to evaporation. The extract was then dissolved in water and vortex mixed before undergoing solid phase extraction using HLB cartridges. Chromatographic separation of the AEDs was achieved using Waters XBridge™ C18 column with a gradient system. The developed method was linear over the concentration ranges studied with r ≥ 0.995 for all compounds. The lower limits of quantification (LLOQs) were 2, 1, 2, 0.5 and 1 μg/mL for LVT, LTG, PHB, CBZE and CBZ, respectively. Accuracy (%RE) and precision (%CV) values for within and between day were <20% at the LLOQs and <15% at all other concentrations tested. This method was successfully applied to the analysis of the AEDs in DBS samples taken from children with epilepsy for the assessment of their adherence to prescribed treatments.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Objective: The aim of this study was to compare the prevalence of sleep habits and complaints and to estimate the secular trends through three population-based surveys carried out in 1987, 1995, and 2007 in the general adult population of the city of Sao Paulo, Brazil. Methods: Surveys were performed using the same three-stage cluster-sampling technique in three consecutive decades to obtain representative samples of the inhabitants of Sao Paulo with respect to gender, age (20-80 years), and socio-economic status. Sample sizes were 1000 volunteers in 1987 and 1995 surveys and 1101 in a 2007 survey. In each survey, the UNIFESP Sleep Questionnaire was administered face-to-face in each household selected. Results: For 1987, 1995, and 2007, respectively, difficulty initiating sleep (weighted frequency %; 95% CI) [(13.9; 11.9-16.2), (19.15; 16.8-21.6), and (25.0; 22.5-27.8)], difficulty maintaining sleep [(15.8; 13.7-18.2), (27.6; 24.9-30.4), and (36.5; 33.5-39.5)], and early morning awakening [(10.6; 8.8-12.7), (14.2; 12.2-16.5), and (26.7; 24-29.6)] increased in the general population over time, mostly in women. Habitual snoring was the most commonly reported complaint across decades and was more prevalent in men. There was no statistically significant difference in snoring complaints between 1987 (21.5; 19.1-24.2) and 1995 (19.0; 16.7-21.6), but a significant increase was noted in 2007 (41.7; 38.6-44.8). Nightmares, bruxism, leg cramps, and somnambulism complaints were significantly higher in 2007 compared to 1987 and 1995. All were more frequent in women. Conclusions: This is the first study comparing sleep complaints in probabilistic population-based samples from the same metropolitan area, using the same methodology across three consecutive decades. Clear trends of increasing sleep complaints were observed, which increased faster between 1995 and 2007 than from 1987 to 1995. These secular trends should be considered a relevant public health issue and support the need for development of health care and educational strategies to supply the population`s increased need for information on sleep disorders and their consequences. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
O presente estudo tem por objetivo avaliar se o perfil do adotante de inovações altera a relação entre o Valor Percebido e a Intenção de Compra de mídias móveis (smartphones, tablets, ultrabooks e leitores de e-books). Trata-se de uma pesquisa quantitativa que busca explorar a relação estrutural entre as variáveis por meio de Modelagem de Equações Estruturais (SEM – Strutural Equation Modeling). O modelo de pesquisa proposto foi desenvolvido tendo como base a Teoria da Difusão da Inovação (TDI), a Teoria Unificada de Aceitação e Uso de Tecnologia (UTAUT), o Modelo de Aceitação de Tecnologia (TAM), o Modelo Baseado em Valor (VAM), o Modelo de Aceitação de Tecnologia pelo Consumidor (CAT) e o Modelo de Influência Social (IS). Para coletar os dados foi utilizada a técnica snowball sampling ou amostragem em bola de neve, forma de amostragem não probabilística utilizada em pesquisas sociais. Foi feito um levantamento (survey), distribuindo-se questionário disponibilizado pela rede social Facebook, a partir dos contatos do autorsolicitando-se que os respondentes replicassem em suas páginas pessoais o link da pesquisa, ampliando a amostra. A coleta dos dados foi realizada nos meses de setembro e outubro de 2013, obtendo-se um total de 362 questionários respondidos. O estudo apresentou um efeito significativo da variável Valor Percebido na Intenção de Compra (estatística t = 4,506; nível de significância de 1%), além de sustentar a influência moderadora do Perfil do Adotante sobre essa relação (estatística t = 4,066; nível de significância de 1%), apresentando alto impacto sobre a Intenção de Compra (f 2 = 0,582) e relevância preditiva moderada (q2 = 0,290). Entre as variáveis antecedentes relacionadas à adoção de tecnologia, não apresentaram efeito significativo sobre o Valor Percebido: a Facilidade de Uso Percebida, a Complexidade Percebida e o Risco Percebido. O modelo contribuiu significativamente para explicar a influência dos fatores que impactam o Valor Percebido (R2 = 51,7%) o efeito do Valor Percebido na Intenção de Compra (R2 = 49,1%) de equipamentos eletrônicos portáteis. O suporte da presumidade influência moderadora do Perfil do Adotante sobre a relação Valor Percebido e Intenção de Compra indica que as organizações devem conhecer melhor os consumidores desse tipo de equipamento móveis, segmentando e desenvolvendo ações alinhadas com cada perfil de adotante.
Resumo:
INTRODUCTION: After the era of rubella vaccine, cytomegalovirus (CMV) infection is one of the most frequently causes of mental retardation and congenital deafness. Seroepidemiological studies are necessary to understand the transmission dynamics of the disease. The purpose of the study was to quantify the transmission rate of CMV disease in a community in the state of São Paulo, Brazil. METHODS: Using ELISA test (IgG), a retrospective serological survey looking for CMV antibodies was performed in an non-immunized community. Frozen sera from 443 individuals, randomly selected by cluster sampling technique in the town of Caieiras, São Paulo, were collected from November 1990 to January 1991. Seroprevalence was stratified by age (0-40 years). Mathematical techniques were applied to determine the age-dependent decay function of maternal antibodies during the first year of life, the age-dependent seroprevalence function and the force of infection for CMV in this community. RESULTS: It was observed a descending phase of seropositivity in the first 9 months, but changes in antibody titration were observed between 8 months old and one year of age. The average age of the first infection was 5.02 months of age and 19.84 years, when the age-dependent seroprevalence and the force of infection were analyzed between 10 months of age and 10 years of age and from 10 to 40 years old, respectively. CONCLUSION: CMV infection is highly prevalent among the population studied and infection occurs in the first year of life. This study shows that most women at reproductive age are vulnerable to the first infection, increasing the risk for congenital infection.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização - Ultrassonografia Cardiovascular
Resumo:
Mestrado em Engenharia Geotécnica e Geoambiente
Resumo:
Jornadas "Ciência nos Açores- que futuro?", Biblioteca Pública e Arquivo Regional de Ponta Delgada, Largo do Colégio, Ponta Delgada, 7-8 de junho de 2013.