963 resultados para sample rate


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aflowinjection squarewave cathodic stripping voltammetric method has been developed for the determination of sertraline in a pharmaceutical preparation. The method shows linearity between peak current intensity and sertraline concentration for the interval between 0.20×10−6 and 1.20×10−6 mol L−1. Limits of detection and quantification were found to be 1.5×10−7 and 5.0×10−7 mol L−1, respectively. Up to 70 samples per hour can be analysed with a good precision (R.S.D. = 2.5%). The proposed method was successfully applied to the determination of sertraline in a commercial product. In the voltammetric determination of sertraline in flow, a high sample rate is obtained at reduced costs, opening the possibility to compete with the chromatographic methods generally used for this analysis.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A parallel processor architecture based on a communicating sequential processor chip, the transputer, is described. The architecture is easily linearly extensible to enable separate functions to be included in the controller. To demonstrate the power of the resulting controller some experimental results are presented comparing PID and full inverse dynamics on the first three joints of a Puma 560 robot. Also examined are some of the sample rate issues raised by the asynchronous updating of inertial parameters, and the need for full inverse dynamics at every sample interval is questioned.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Epilepsies are neurological disorders characterized by recurrent and spontaneous seizures due to an abnormal electric activity in a brain network. The mesial temporal lobe epilepsy (MTLE) is the most prevalent type of epilepsy in adulthood, and it occurs frequently in association with hippocampal sclerosis. Unfortunately, not all patients benefit from pharmacological treatment (drug-resistant patients), and therefore become candidates for surgery, a procedure of high complexity and cost. Nowadays, the most common surgery is the anterior temporal lobectomy with selective amygdalohippocampectomy, a procedure standardized by anatomical markers. However, part of patients still present seizure after the procedure. Then, to increase the efficiency of this kind of procedure, it is fundamental to know the epileptic human brain in order to create new tools for auxiliary an individualized surgery procedure. The aim of this work was to identify and quantify the occurrence of epilepticform activity -such as interictal spikes (IS) and high frequency oscillations (HFO) - in electrocorticographic (ECoG) signals acutely recorded during the surgery procedure in drug-resistant patients with MTLE. The ECoG recording (32 channels at sample rate of 1 kHz) was performed in the surface of temporal lobe in three moments: without any cortical resection, after anterior temporal lobectomy and after amygdalohippocampectomy (mean duration of each record: 10 min; N = 17 patients; ethic approval #1038/03 in Research Ethic Committee of Federal University of São Paulo). The occurrence of IS and HFO was quantified automatically by MATLAB routines and validated manually. The events rate (number of events/channels) in each recording time was correlated with seizure control outcome. In 8 hours and 40 minutes of record, we identified 36,858 IS and 1.756 HFO. We observed that seizure-free outcome patients had more HFO rate before the resection than non-seizure free, however do not differentiate in relation of frequency, morphology and distribution of IS. The HFO rate in the first record was better than IS rate on prediction of seizure-free patients (IS: AUC = 57%, Sens = 70%, Spec = 71% vs HFO: AUC = 77%, Sens = 100%, Spec = 70%). We observed the same for the difference of the rate of pre and post-resection (IS: AUC = 54%, Sens = 60%, Spec = 71%; vs HFO: AUC = 84%, Sens = 100%, Spec = 80%). In this case, the algorithm identifies all seizure-free patients (N = 7) with two false positives. To conclude, we observed that the IS and HFO can be found in intra-operative ECoG record, despite the anesthesia and the short time of record. The possibility to classify the patients before any cortical resection suggest that ECoG can be important to decide the use of adjuvant pharmacological treatment or to change for tailored resection procedure. The mechanism responsible for this effect is still unknown, thus more studies are necessary to clarify the processes related to it

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Desenvolvimento Humano e Tecnologias - IBRC

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new idea for waveform coding using vector quantisation (VQ) is introduced. This idea makes it possible to deal with codevectors much larger than before for a fixed bit per sample rate. Also a solution to the matching problem (inherent in the present context) in the &-norm describing a measure of neamess is presented. The overall computational complexity of this solution is O(n3 log, n). Sample results are presented to demonstrate the advantage of using this technique in the context of coding of speech waveforms.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The exsolution of volatiles from magma maintains an important control on volcanic eruption styles. The nucleation, growth, and connectivity of bubbles during magma ascent provide the driving force behind eruptions, and the rate, volume, and ease of gas exsolution can affect eruptive activity. Volcanic plumes are the observable consequence of this magmatic degassing, and remote sensing techniques allow us to quantify changes in gas exsolution. However, until recently the methods used to measure volcanic plumes did not have the capability of detecting rapid changes in degassing on the scale of standard geophysical observations. The advent of the UV camera now makes high sample rate gas measurements possible. This type of dataset can then be compared to other volcanic observations to provide an in depth picture of degassing mechanisms in the shallow conduit. The goals of this research are to develop a robust methodology for UV camera field measurements of volcanic plumes, and utilize this data in conjunction with seismoacoustic records to illuminate degassing processes. Field and laboratory experiments were conducted to determine the effects of imaging conditions, vignetting, exposure time, calibration technique, and filter usage on the UV camera sulfur dioxide measurements. Using the best practices determined from these studies, a field campaign was undertaken at Volcán de Pacaya, Guatemala. Coincident plume sulfur dioxide measurements, acoustic recordings, and seismic observations were collected and analyzed jointly. The results provide insight into the small explosive features, variations in degassing rate, and plumbing system of this complex volcanic system. This research provides useful information for determining volcanic hazard at Pacaya, and demonstrates the potential of the UV camera in multiparameter studies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Methods of rapidly measuring an impedance spectrum of an energy storage device in-situ over a limited number of logarithmically distributed frequencies are described. An energy storage device is excited with a known input signal, and aresponse is measured to ascertain the impedance spectrum. An excitation signal is a limited time duration sum-of-sines consisting of a select number offrequencies. In one embodiment, magnitude and phase of each frequency ofinterest within the sum-of-sines is identified when the selected frequencies and sample rate are logarithmic integer steps greater than two. This technique requires a measurement with a duration of one period of the lowest frequency. In another embodiment, where selected frequencies are distributed in octave steps, the impedance spectrum can be determined using a captured time record that is reduced to a half-period of the lowest frequency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A ciência na qual se estuda a deformação de um fluido no qual é aplicada uma tensão de cisalhamento é conhecida como reologia e o equipamento utilizado para a realização dos ensaios é chamado de reômetro. Devido a impraticabilidade de uso de reômetros comerciais, diversos pesquisadores desenvolveram reômetros capazes de analisar suspensões de macropartículas, baseados nos mesmos princípios de funcionamento dos equipamentos já existentes. Em alguns casos, a medição do torque do motor é realizada pela aquisição da tensão, uma vez que esta é proporcional ao torque. Entretanto, para melhor compreensão do resultado e para evitar a possibilidade de conclusões precipitadas, vê-se necessária correta interpretação do sinal elétrico, precisando avaliar qual frequência do sinal é relevante para o ensaio e, também, qual a melhor taxa de amostragem. Além da aquisição, para que o ensaio reológico seja realizado com precisão, é indispensável ótimo controle da taxa ou tensão do motor e uma alternativa é a utilização de um servomotor e um servoconversor. No caso desse ser comercial é essencial saber configurá-lo. Para facilitar o usuário leigo, alguns pesquisadores desenvolveram softwares para controle do equipamento e análise dos dados. Assim, o presente trabalho tem como objetivo propor uma metodologia para compreender o sinal aquisitado de um reômetro servo controlado e desenvolvimento do software de análise para o tratamento dos dados obtidos a partir de ensaios reológicos. Verificou-se a melhor configuração do servocontrolador, a melhor taxa de amostragem, de no mínimo 20 amostras/segundo, e, também, desenvolveu-se um filtro digital passa-baixa do tipo FIR para remover a frequência indesejada. Além disso, foi desenvolvido um software utilizando uma rotina em Matlab e uma interface gráfica do usuário (Graphical User Interface - GUI), para o pós-processamento dos dados para auxiliar o usuário leigo no tratamento e interpretação do resultado, que se mostrou eficaz.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report statistical time-series analysis tools providing improvements in the rapid, precision extraction of discrete state dynamics from time traces of experimental observations of molecular machines. By building physical knowledge and statistical innovations into analysis tools, we provide techniques for estimating discrete state transitions buried in highly correlated molecular noise. We demonstrate the effectiveness of our approach on simulated and real examples of steplike rotation of the bacterial flagellar motor and the F1-ATPase enzyme. We show that our method can clearly identify molecular steps, periodicities and cascaded processes that are too weak for existing algorithms to detect, and can do so much faster than existing algorithms. Our techniques represent a step in the direction toward automated analysis of high-sample-rate, molecular-machine dynamics. Modular, open-source software that implements these techniques is provided.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This dissertation presents the design of three high-performance successive-approximation-register (SAR) analog-to-digital converters (ADCs) using distinct digital background calibration techniques under the framework of a generalized code-domain linear equalizer. These digital calibration techniques effectively and efficiently remove the static mismatch errors in the analog-to-digital (A/D) conversion. They enable aggressive scaling of the capacitive digital-to-analog converter (DAC), which also serves as sampling capacitor, to the kT/C limit. As a result, outstanding conversion linearity, high signal-to-noise ratio (SNR), high conversion speed, robustness, superb energy efficiency, and minimal chip-area are accomplished simultaneously. The first design is a 12-bit 22.5/45-MS/s SAR ADC in 0.13-μm CMOS process. It employs a perturbation-based calibration based on the superposition property of linear systems to digitally correct the capacitor mismatch error in the weighted DAC. With 3.0-mW power dissipation at a 1.2-V power supply and a 22.5-MS/s sample rate, it achieves a 71.1-dB signal-to-noise-plus-distortion ratio (SNDR), and a 94.6-dB spurious free dynamic range (SFDR). At Nyquist frequency, the conversion figure of merit (FoM) is 50.8 fJ/conversion step, the best FoM up to date (2010) for 12-bit ADCs. The SAR ADC core occupies 0.06 mm2, while the estimated area the calibration circuits is 0.03 mm2. The second proposed digital calibration technique is a bit-wise-correlation-based digital calibration. It utilizes the statistical independence of an injected pseudo-random signal and the input signal to correct the DAC mismatch in SAR ADCs. This idea is experimentally verified in a 12-bit 37-MS/s SAR ADC fabricated in 65-nm CMOS implemented by Pingli Huang. This prototype chip achieves a 70.23-dB peak SNDR and an 81.02-dB peak SFDR, while occupying 0.12-mm2 silicon area and dissipating 9.14 mW from a 1.2-V supply with the synthesized digital calibration circuits included. The third work is an 8-bit, 600-MS/s, 10-way time-interleaved SAR ADC array fabricated in 0.13-μm CMOS process. This work employs an adaptive digital equalization approach to calibrate both intra-channel nonlinearities and inter-channel mismatch errors. The prototype chip achieves 47.4-dB SNDR, 63.6-dB SFDR, less than 0.30-LSB differential nonlinearity (DNL), and less than 0.23-LSB integral nonlinearity (INL). The ADC array occupies an active area of 1.35 mm2 and dissipates 30.3 mW, including synthesized digital calibration circuits and an on-chip dual-loop delay-locked loop (DLL) for clock generation and synchronization.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The study is a three-armed randomized controlled trial comparing values for heart rate variability (HRV), a measure of cardiovascular health, throughout a yoga intervention of breast cancer patients undergoing radiotherapy. Patients attended either a yoga (n=45), stretch, (n=46), or control (n=42) condition 3 times per week for 6 weeks of radiation. Electrocardiograms (ECGs) were conducted on each participant to provide the values necessary for HRV analysis. Analyses focused on examining scores for those participants with HRV baseline values considered to be below the cutoff point for healthy HRV levels, defined by the authors as below the cutpoint of 68 ms. From the entire sample of 133 with available baselines, 26 yogis, 26 stretchers, and 23 controls were determined to be “pathologic” in terms of HRV, and selected for follow-up analysis at 3 weeks and then again at 6 weeks. Though no statistically significant differences were found between either group means at each timepoint or group change score means, the yoga group had consistently higher mean score and mean change scores. These findings are suggestive and indicate the need to refine the use of ECGs and HRV analysis programs to more accurately and comprehensively assess the effects of yoga on cardiovascular health in cancer patients.^