973 resultados para power measurements
Resumo:
Electrical conductivity and thermoelectric power measurements carried out in a heamatite ceramic showed a strong anisotropy in directions normal and parallel to the uniaxial pressing direction. This behaviour is similar to that verified in alpha-Fe2O3 single crystal. The results suggest that the extended structural defects, generated during sintering, disturb the magnetic order on the (001) planes of alpha-Fe2O3 and limit the mobility of n type carriers.
Resumo:
The paper explains the conceptual design of instrumentation that measures electric quantities defined in the trial-use Std. 1459-2000. It is shown how the Instantaneous-Space-Phasor (ISP) approach, based on α, β, 0 components, can be used to monitor electric energy flow, evaluate the utilization of transmission line and quantify the level of harmonic pollution injected by nonlinear loads.
Resumo:
This work examines the effect of copper nanoparticles (Cu NPs) on the photocurrent efficiency of silicon photovoltaic (Si PV) devices. An optimized synthesis of stable Cu NPs is reported together with a procedure for their immobilization on the Si PV surface. A comprehensive analysis of the photocurrent and power dependence of the Cu NPs surface coverage and size is presented. A decrease in photoconversion was observed for wavelengths shorter than similar to 500 nm, due to the Cu interband absorption. In the low surface coverage limit, where the level of aggregation was found to be low, the surface plasmon resonance absorption dominates leading to a modest effect on the photocurrent response. As the number of aggregates increased with the surface coverage, the photocurrent efficiency also increased, and a maximum enhancement power conversion of 16% was found for a 54 +/- 6 NPs per mu m(2) PV cell. This enhancement was attributed to SPR light scattering and trapping into the Si PV device. Higher surface coverage yielded numerous aggregates which acted as a bulk coating and caused a decrease in both photocurrent and power measurements.
Resumo:
The effects of cryogenic and stress relief treatments on temper carbide precipitation in the cold work tool steel AISI D2 were studied. For the cryogenic treatment the temperature was −196°C and the holding time was 2, 24 or 30 h. The stress relief heat treatment was carried at 130°C/90 min, when applied. All specimens were compared to a standard thermal cycle. Specimens were studied using metallographic characterisation, X-ray diffraction and thermoelectric power measurements. The metallographic characterisation used SEM (scanning electron microscopy) and SEM-FEG (SEM with field emission gun), besides OM (optical microscopy). No variation in the secondary carbides (micrometre sized) precipitation was found. The temper secondary carbides (nanosized) were found to be more finely dispersed in the matrix of the specimens with cryogenic treatment and without stress relief. The refinement of the temper secondary carbides was attributed to a possible in situ carbide precipitation during tempering.
Resumo:
The running innovation processes of the microwave transistor technologies, used in the implementation of microwave circuits, have to be supported by the study and development of proper design methodologies which, depending on the applications, will fully exploit the technology potentialities. After the choice of the technology to be used in the particular application, the circuit designer has few degrees of freedom when carrying out his design; in the most cases, due to the technological constrains, all the foundries develop and provide customized processes optimized for a specific performance such as power, low-noise, linearity, broadband etc. For these reasons circuit design is always a “compromise”, an investigation for the best solution to reach a trade off between the desired performances. This approach becomes crucial in the design of microwave systems to be used in satellite applications; the tight space constraints impose to reach the best performances under proper electrical and thermal de-rated conditions, respect to the maximum ratings provided by the used technology, in order to ensure adequate levels of reliability. In particular this work is about one of the most critical components in the front-end of a satellite antenna, the High Power Amplifier (HPA). The HPA is the main power dissipation source and so the element which mostly engrave on space, weight and cost of telecommunication apparatus; it is clear from the above reasons that design strategies addressing optimization of power density, efficiency and reliability are of major concern. Many transactions and publications demonstrate different methods for the design of power amplifiers, highlighting the availability to obtain very good levels of output power, efficiency and gain. Starting from existing knowledge, the target of the research activities summarized in this dissertation was to develop a design methodology capable optimize power amplifier performances complying all the constraints imposed by the space applications, tacking into account the thermal behaviour in the same manner of the power and the efficiency. After a reminder of the existing theories about the power amplifier design, in the first section of this work, the effectiveness of the methodology based on the accurate control of the dynamic Load Line and her shaping will be described, explaining all steps in the design of two different kinds of high power amplifiers. Considering the trade-off between the main performances and reliability issues as the target of the design activity, we will demonstrate that the expected results could be obtained working on the characteristics of the Load Line at the intrinsic terminals of the selected active device. The methodology proposed in this first part is based on the assumption that designer has the availability of an accurate electrical model of the device; the variety of publications about this argument demonstrates that it is so difficult to carry out a CAD model capable to taking into account all the non-ideal phenomena which occur when the amplifier operates at such high frequency and power levels. For that, especially for the emerging technology of Gallium Nitride (GaN), in the second section a new approach for power amplifier design will be described, basing on the experimental characterization of the intrinsic Load Line by means of a low frequency high power measurements bench. Thanks to the possibility to develop my Ph.D. in an academic spin-off, MEC – Microwave Electronics for Communications, the results of this activity has been applied to important research programs requested by space agencies, with the aim support the technological transfer from universities to industrial world and to promote a science-based entrepreneurship. For these reasons the proposed design methodology will be explained basing on many experimental results.
Resumo:
Determinar con buena precisión la posición en la que se encuentra un terminal móvil, cuando éste se halla inmerso en un entorno de interior (centros comerciales, edificios de oficinas, aeropuertos, estaciones, túneles, etc), es el pilar básico sobre el que se sustentan un gran número de aplicaciones y servicios. Muchos de esos servicios se encuentran ya disponibles en entornos de exterior, aunque los entornos de interior se prestan a otros servicios específicos para ellos. Ese número, sin embargo, podría ser significativamente mayor de lo que actualmente es, si no fuera necesaria una costosa infraestructura para llevar a cabo el posicionamiento con la precisión adecuada a cada uno de los hipotéticos servicios. O, igualmente, si la citada infraestructura pudiera tener otros usos distintos, además del relacionado con el posicionamiento. La usabilidad de la misma infraestructura para otros fines distintos ofrecería la oportunidad de que la misma estuviera ya presente en las diferentes localizaciones, porque ha sido previamente desplegada para esos otros usos; o bien facilitaría su despliegue, porque el coste de esa operación ofreciera un mayor retorno de usabilidad para quien lo realiza. Las tecnologías inalámbricas de comunicaciones basadas en radiofrecuencia, ya en uso para las comunicaciones de voz y datos (móviles, WLAN, etc), cumplen el requisito anteriormente indicado y, por tanto, facilitarían el crecimiento de las aplicaciones y servicios basados en el posicionamiento, en el caso de poderse emplear para ello. Sin embargo, determinar la posición con el nivel de precisión adecuado mediante el uso de estas tecnologías, es un importante reto hoy en día. El presente trabajo pretende aportar avances significativos en este campo. A lo largo del mismo se llevará a cabo, en primer lugar, un estudio de los principales algoritmos y técnicas auxiliares de posicionamiento aplicables en entornos de interior. La revisión se centrará en aquellos que sean aptos tanto para tecnologías móviles de última generación como para entornos WLAN. Con ello, se pretende poner de relieve las ventajas e inconvenientes de cada uno de estos algoritmos, teniendo como motivación final su aplicabilidad tanto al mundo de las redes móviles 3G y 4G (en especial a las femtoceldas y small-cells LTE) como al indicado entorno WLAN; y teniendo siempre presente que el objetivo último es que vayan a ser usados en interiores. La principal conclusión de esa revisión es que las técnicas de triangulación, comúnmente empleadas para realizar la localización en entornos de exterior, se muestran inútiles en los entornos de interior, debido a efectos adversos propios de este tipo de entornos como la pérdida de visión directa o los caminos múltiples en el recorrido de la señal. Los métodos de huella radioeléctrica, más conocidos bajo el término inglés “fingerprinting”, que se basan en la comparación de los valores de potencia de señal que se están recibiendo en el momento de llevar a cabo el posicionamiento por un terminal móvil, frente a los valores registrados en un mapa radio de potencias, elaborado durante una fase inicial de calibración, aparecen como los mejores de entre los posibles para los escenarios de interior. Sin embargo, estos sistemas se ven también afectados por otros problemas, como por ejemplo los importantes trabajos a realizar para ponerlos en marcha, y la variabilidad del canal. Frente a ellos, en el presente trabajo se presentan dos contribuciones originales para mejorar los sistemas basados en los métodos fingerprinting. La primera de esas contribuciones describe un método para determinar, de manera sencilla, las características básicas del sistema a nivel del número de muestras necesarias para crear el mapa radio de la huella radioeléctrica de referencia, junto al número mínimo de emisores de radiofrecuencia que habrá que desplegar; todo ello, a partir de unos requerimientos iniciales relacionados con el error y la precisión buscados en el posicionamiento a realizar, a los que uniremos los datos correspondientes a las dimensiones y realidad física del entorno. De esa forma, se establecen unas pautas iniciales a la hora de dimensionar el sistema, y se combaten los efectos negativos que, sobre el coste o el rendimiento del sistema en su conjunto, son debidos a un despliegue ineficiente de los emisores de radiofrecuencia y de los puntos de captura de su huella. La segunda contribución incrementa la precisión resultante del sistema en tiempo real, gracias a una técnica de recalibración automática del mapa radio de potencias. Esta técnica tiene en cuenta las medidas reportadas continuamente por unos pocos puntos de referencia estáticos, estratégicamente distribuidos en el entorno, para recalcular y actualizar las potencias registradas en el mapa radio. Un beneficio adicional a nivel operativo de la citada técnica, es la prolongación del tiempo de usabilidad fiable del sistema, bajando la frecuencia en la que se requiere volver a capturar el mapa radio de potencias completo. Las mejoras anteriormente citadas serán de aplicación directa en la mejora de los mecanismos de posicionamiento en interiores basados en la infraestructura inalámbrica de comunicaciones de voz y datos. A partir de ahí, esa mejora será extensible y de aplicabilidad sobre los servicios de localización (conocimiento personal del lugar donde uno mismo se encuentra), monitorización (conocimiento por terceros del citado lugar) y seguimiento (monitorización prolongada en el tiempo), ya que todos ellas toman como base un correcto posicionamiento para un adecuado desempeño. ABSTRACT To find the position where a mobile is located with good accuracy, when it is immersed in an indoor environment (shopping centers, office buildings, airports, stations, tunnels, etc.), is the cornerstone on which a large number of applications and services are supported. Many of these services are already available in outdoor environments, although the indoor environments are suitable for other services that are specific for it. That number, however, could be significantly higher than now, if an expensive infrastructure were not required to perform the positioning service with adequate precision, for each one of the hypothetical services. Or, equally, whether that infrastructure may have other different uses beyond the ones associated with positioning. The usability of the same infrastructure for purposes other than positioning could give the opportunity of having it already available in the different locations, because it was previously deployed for these other uses; or facilitate its deployment, because the cost of that operation would offer a higher return on usability for the deployer. Wireless technologies based on radio communications, already in use for voice and data communications (mobile, WLAN, etc), meet the requirement of additional usability and, therefore, could facilitate the growth of applications and services based on positioning, in the case of being able to use it. However, determining the position with the appropriate degree of accuracy using these technologies is a major challenge today. This paper provides significant advances in this field. Along this work, a study about the main algorithms and auxiliar techniques related with indoor positioning will be initially carried out. The review will be focused in those that are suitable to be used with both last generation mobile technologies and WLAN environments. By doing this, it is tried to highlight the advantages and disadvantages of each one of these algorithms, having as final motivation their applicability both in the world of 3G and 4G mobile networks (especially in femtocells and small-cells of LTE) and in the WLAN world; and having always in mind that the final aim is to use it in indoor environments. The main conclusion of that review is that triangulation techniques, commonly used for localization in outdoor environments, are useless in indoor environments due to adverse effects of such environments as loss of sight or multipaths. Triangulation techniques used for external locations are useless due to adverse effects like the lack of line of sight or multipath. Fingerprinting methods, based on the comparison of Received Signal Strength values measured by the mobile phone with a radio map of RSSI Recorded during the calibration phase, arise as the best methods for indoor scenarios. However, these systems are also affected by other problems, for example the important load of tasks to be done to have the system ready to work, and the variability of the channel. In front of them, in this paper we present two original contributions to improve the fingerprinting methods based systems. The first one of these contributions describes a method for find, in a simple way, the basic characteristics of the system at the level of the number of samples needed to create the radio map inside the referenced fingerprint, and also by the minimum number of radio frequency emitters that are needed to be deployed; and both of them coming from some initial requirements for the system related to the error and accuracy in positioning wanted to have, which it will be joined the data corresponding to the dimensions and physical reality of the environment. Thus, some initial guidelines when dimensioning the system will be in place, and the negative effects into the cost or into the performance of the whole system, due to an inefficient deployment of the radio frequency emitters and of the radio map capture points, will be minimized. The second contribution increases the resulting accuracy of the system when working in real time, thanks to a technique of automatic recalibration of the power measurements stored in the radio map. This technique takes into account the continuous measures reported by a few static reference points, strategically distributed in the environment, to recalculate and update the measurements stored into the map radio. An additional benefit at operational level of such technique, is the extension of the reliable time of the system, decreasing the periodicity required to recapture the radio map within full measurements. The above mentioned improvements are directly applicable to improve indoor positioning mechanisms based on voice and data wireless communications infrastructure. From there, that improvement will be also extensible and applicable to location services (personal knowledge of the location where oneself is), monitoring (knowledge by other people of your location) and monitoring (prolonged monitoring over time) as all of them are based in a correct positioning for proper performance.
Resumo:
Three different methods of inclusion of current measurements by phasor measurement units (PMUs) in a power sysetm state estimator is investigated. A comprehensive formulation of the hybrid state estimator incorporating conventional, as well as PMU measurements, is presented for each of the three methods. The behaviour of the elements because of the current measurements in the measurement Jacobian matrix is examined for any possible ill-conditioning of the state estimator gain matrix. The performance of the state estimators are compared in terms of the convergence properties and the varian in the estimated states. The IEEE 14-bus and IEEE 300-bus systems are used as test beds for the study.
Resumo:
In this brief, a hybrid filter algorithm is developed to deal with the state estimation (SE) problem for power systems by taking into account the impact from the phasor measurement units (PMUs). Our aim is to include PMU measurements when designing the dynamic state estimators for power systems with traditional measurements. Also, as data dropouts inevitably occur in the transmission channels of traditional measurements from the meters to the control center, the missing measurement phenomenon is also tackled in the state estimator design. In the framework of extended Kalman filter (EKF) algorithm, the PMU measurements are treated as inequality constraints on the states with the aid of the statistical criterion, and then the addressed SE problem becomes a constrained optimization one based on the probability-maximization method. The resulting constrained optimization problem is then solved using the particle swarm optimization algorithm together with the penalty function approach. The proposed algorithm is applied to estimate the states of the power systems with both traditional and PMU measurements in the presence of probabilistic data missing phenomenon. Extensive simulations are carried out on the IEEE 14-bus test system and it is shown that the proposed algorithm gives much improved estimation performances over the traditional EKF method.
Resumo:
Certain materials used and produced in a wide range of non-nuclear industries contain enhanced activity concentrations of natural radionuclides. In particular, electricity production from coal is one of the major sources of increased exposure to man from enhanced naturally occurring materials. Over the past decades there has been some discussion about the elevated natural background radiation in the area near coal-fired power plants due to high uranium and thorium content present in coal. This work describes the methodology developed to assess the radiological impact due to natural radiation background increasing levels, potentially originated by a coal-fired power plant’s operation. Gamma radiation measurements have been done with two different instruments: a scintillometer (SPP2 NF, Saphymo) and a gamma ray spectrometer with energy discrimination (Falcon 5000, Canberra). A total of 40 relevant sampling points were established at locations within 20 km from the power plant: 15 urban and 25 suburban measured stations. The highest values were measured at the sampling points near to the power plant and those located in the area within the 6 and 20 km from the stacks. This may be explained by the presence of a huge coal pile (1.3 million tons) located near the stacks contributing to the dispersion of unburned coal and, on the other hand, the height of the stacks (225 m) which may influence ash’s dispersion up to a distance of 20 km. In situ gamma radiation measurements with energy discrimination identified natural emitting nuclides as well as their decay products (212Pb, 214Pb, 226Ra 232Th, 228Ac, 234Th 234Pa, 235U, etc.). This work has been primarily done to in order to assess the impact of a coal-fired power plant operation on the background radiation level in the surrounding area. According to the results, an increase or at least an influence has been identified both qualitatively and quantitatively.
Resumo:
The current design life of nuclear power plant (NPP) could potentially be extended to 80 years. During this extended plant life, all safety and operationally relevant Instrumentation & Control (I&C) systems are required to meet their designed performance requirements to ensure safe and reliable operation of the NPP, both during normal operation and subsequent to design base events. This in turn requires an adequate and documented qualification and aging management program. It is known that electrical insulation of I&C cables used in safety related circuits can degrade during their life, due to the aging effect of environmental stresses, such as temperature, radiation, vibration, etc., particularly if located in the containment area of the NPP. Thus several condition monitoring techniques are required to assess the state of the insulation. Such techniques can be used to establish a residual lifetime, based on the relationship between condition indicators and ageing stresses, hence, to support a preventive and effective maintenance program. The object of this thesis is to investigate potential electrical aging indicators (diagnostic markers) testing various I&C cable insulations subjected to an accelerated multi-stress (thermal and radiation) aging.
Resumo:
The heating produced by the absorption of radiofrequency (RF) has been considered a secondary undesirable effect during MRI procedures. In this work, we have measured the power absorbed by distilled water, glycerol and egg-albumin during NMR and non-NMR experiments. The samples are dielectric and examples of different biological materials. The samples were irradiated using the same RF pulse sequence, whilst the magnetic field strength was the variable to be changed in the experiments. The measurements show a smooth increase of the thermal power as the magnetic field grows due to the magnetoresistive effect in the copper antenna, a coil around the probe, which is directly heating the sample. However, in the cases when the magnetic field was the adequate for the NMR to take place, some anomalies in the expected thermal powers were observed: the thermal power was higher in the cases of water and glycerol, and lower in the case of albumin. An ANOVA test demonstrated that the observed differences between the measured power and the expected power are significant.
Resumo:
Nowadays the interest in high power semiconductor devices is growing for applications such as telemetry, lidar system or free space communications. Indeed semiconductor devices can be an alternative to solid state lasers because they are more compact and less power consuming. These characteristics are very important for constrained and/or low power supply environment such as airplanes or satellites. Lots of work has been done in the 800-1200 nm range for integrated and free space Master Oscillator Power Amplifier (MOPA) [1]-[3]. At 1.5 ?m, the only commercially available MOPA is from QPC [4]: the fibred output power is about 700 mW and the optical linewidth is 500 kHz. In this paper, we first report on the simulations we have done to determine the appropriate vertical structure and architecture for a good MOPA at 1.58 ?m (section II). Then we describe the fabrication of the devices (section III). Finally we report on the optical and electrical measurements we have done for various devices (section IV).
Resumo:
"June 1979."
Resumo:
Mode of access: Internet.
Resumo:
"Contract AT(30-1)-2789."