968 resultados para operating room


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND METHODS We conducted a focus group analysis with students and surgeons on factors which influence medical school students' education in the operating room (OR). The interviews were analyzed using grounded theory. RESULTS The analysis resulted in 18 detailed and easily applyable themes, which were grouped into the four categories: "Students' preparation and organizational aspects", "Learning objectives", "Educational strategies for the teacher", and "Social-environmental aspects". CONCLUSION By including students and surgeons, we were able to extend existing knowledge and enable better understanding of factors influencing teaching in the OR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Noise peaks are powerful distractors. This study focuses on the impact of noise peaks on surgical teams' communication during 109 long abdominal surgeries. We related measured noise peaks during 5-min intervals to the amount of observed communication during the same interval. Results show that noise peaks are associated with less case-relevant communication; this effect is moderated by the level of surgical experience; case-relevant communications decrease under high noise peak conditions among junior, but not among senior surgeons. However, case-irrelevant communication did not decrease under high noise level conditions, rather there was a trend to more case-irrelevant communication under high noise peaks. The results support the hypothesis that noise peaks impair communication because they draw on attentional resources rather than impairing understanding of communication. As case-relevant communication is important for surgical performance, exposure to high noise peaks in the OR should be minimised especially for less experienced surgeons. Practitioner Summary: This study investigated whether noise during surgeries influenced the communication within surgical teams. During abdominal surgeries, noise levels were measured and communication was observed. Results showed that high noise peaks reduced the frequency of patient-related communication, but did not reduce patient-irrelevant communication. Noise may negatively affect team coordination in surgeries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The operating theatres are the engine of the hospitals; proper management of the operating rooms and its staff represents a great challenge for managers and its results impact directly in the budget of the hospital. This work presents a MILP model for the efficient schedule of multiple surgeries in Operating Rooms (ORs) during a working day. This model considers multiple surgeons and ORs and different types of surgeries. Stochastic strategies are also implemented for taking into account the uncertain in surgery durations (pre-incision, incision, post-incision times). In addition, a heuristic-based methods and a MILP decomposition approach is proposed for solving large-scale ORs scheduling problems in computational efficient way. All these computer-aided strategies has been implemented in AIMMS, as an advanced modeling and optimization software, developing a user friendly solution tool for the operating room management under uncertainty.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To describe the documentary quality of two records related to patient safety in the operating room and to identify differences between information related to infection and hospitalization. Methods: Comparative study based on two cross sections, conducted with 3,033 patients who had been hospitalized for more than 24 hours in an Orthopedics and Traumatology Center. Sociodemographic and clinical data, as well as information provided in forms were compared. Postoperative infection was identified as an adverse event. Results: There was a significant correlation between hospitalization days and the total number of diagnoses collected (Pearson=0.328; p<0.001). When diagnoses and infections were grouped together, a significant value was found between closed fractures and infection (p=0.001). Conclusion: Differences in the degree of completion were observed between the two records. There were no differences between adverse events.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nancrede operating in the 1890s. Cyrenus Darling is the large man facing Nancrede. (source: University of Michigan Surgeons 1850-1970: Who They Were and What They Did by Horace W. Davenport. On verso: Dr. C. B. G. de Nancrede operating?

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper investigates the environmental conditions inside a highly-glazed cross-ventilated meeting room. A 3D computational fluid dynamics (CFD) model of an indoor environment is developed with the support of the field measurements performed in a normally operating room. The work presented here follows the steps of the formal calibration methodology for the development of CFD models of naturally ventilated environments. This paper utilises the calibration methodology in order to predict environmental conditions within the highly-glazed cross-ventilated room occupied by people. The CFD model is verified and validated with field measurements performed in an operating building. Moreover, parametric analysis determines the most influential boundary conditions on indoor air temperatures and air speeds

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVES: Pediatric resuscitation is an intense, stressful, and challenging process. The aim of this study was to review the life-threatening pediatric (LTP) emergencies admitted in a Swiss university hospital with regards to patients' demographics, reason for admission, diagnosis, treatment, significant events, critical incidents, and outcomes. METHODS: A retrospective observational cohort study of prospectively collected data was conducted, including all LTP emergencies admitted over a period of 2 years in the resuscitation room (RR). Variables, including indication for transfer, mode of prehospital transportation, diagnosis, and time spent in RR, were recorded. RESULTS: Of the 60,939 pediatric emergencies treated in our university hospital over 2 years, a total of 277 LTP emergencies (0.46%) were admitted in the RR. They included 160 boys and 117 girls, aged 6 days to 15.95 years (mean, 6.69 years; median, 5.06). A medical problem was identified in 55.9% (n = 155) of the children. Of the 122 children treated for a surgical problem, 35 (28.3%) went directly from the RR to the operating room. Hemodynamic instability was noted in 19.5% of all LTP emergencies, of which 1.1% benefited from O negative transfusion. Admission to the intensive care unit was necessary for 61.6% of the children transferred from another hospital. The average time spent in the RR was 46 minutes. The overall mortality rate was 7.2%. CONCLUSIONS: The LTP emergencies accounted for a small proportion of all pediatric emergencies. They were more medical than surgical cases and resuscitation measures because of hemodynamic instability were the most frequent treatment.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Summary : This research evolved out of the need to examine the validity and inter-rater reliability of a set of performance-based scoring rubrics designed to measure competencies within the operating suite.

Method : Both holistic and analytical rubrics were developed aligned to the ACORN Standard [Australian College of Operating Room Nurses Standard NR4, 2004. ACORN Competency Standards for Perioperative Nurses: Standard NR4: The Instrument Nurse in the Perioperative Environment. Australian College of Operating Room Nurses Ltd, Adelaide] and underpinned by the Dreyfus model (1981). Three video clips that captured varying performance of nurses performing as instrument nurses in the operating suite were recorded and used as prompts by expert raters, who judged the performance using the rubrics.

Results :
The study found that the holistic rubrics led to more consistent judgments than the analytical rubrics, yet the latter provided more diagnostic information for intervention purposes. Despite less consistency, the Analytical Observation Form had sufficient construct validity to satisfy the requirements of criterion referencing as determined by the Item Separation Index (Rasch, 1960), including high internal consistency and greater inter-rater reliability when average ratings were used.

Conclusion :
The study was an empirical investigation of the use of concomitant Analytical and Holistic Rubrics to determine various levels of performance in the operating suite including inter-rater reliability. The methodology chosen was theoretically sound and sufficiently flexible to be used to develop other competencies within the operating suite.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As a key department within a healthcare organisation, the operating room is a hazardous environment, where the consequences of errors are high, despite the relatively low rates of occurrence. Team performance in surgery is increasingly being considered crucial for a culture of safety. The aim of this study was to describe team communication and the ways it fostered or threatened safety culture in surgery. Ethnography was used, and involved a 6-month fieldwork period of observation and 19 interviews with 24 informants from nursing, anaesthesia and surgery. Data were collected during 2009 in the operating rooms of a tertiary care facility in Queensland, Australia. Through analysis of the textual data, three themes that exemplified teamwork culture in surgery were generated: ‘‘building shared understandings through open communication’’; ‘‘managing contextual stressors in a hierarchical environment’’ and ‘‘intermittent membership influences team performance’’. In creating a safety culture in a healthcare organisation, a team’s optimal performance relies on the open discussion of teamwork and team expectation, and significantly depends on how the organisational culture promotes such discussions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Extra corporeal membrane oxygenation (ECMO) is a complex rescue therapy used to provide cardiac and/or respiratory support for critically ill patients who have failed maximal conventional medical management. ECMO is based on a modified cardiopulmonary bypass (CPB) circuit, and can provide cardiopulmonary support for up-to several months. It can be used in a veno venous configuration for isolated respiratory failure, (VV-ECMO), or in a veno arterial configuration (VA-ECMO) where support is necessary for cardiac +/- respiratory failure. The ECMO circuit consists of five main components: large bore cannulae (access cannulae) for drainage of the venous system, and return cannulae to either the venous (in VV-ECMO) or arterial (in VA ECMO) system. An oxygenator, with a vast surface area of hollow filaments, allows addition of oxygen and removal of carbon dioxide; a centrifugal blood pump allows propulsion of blood through the circuit at upto 10 L/minute; a control module and a thermoregulatory unit, which allows for exact temperature control of the extra corporeal blood. Methods: The first successful use of ECMO for ARDS in adults occurred in 1972, and its use has become more commonplace over the last 30 years, supported by the improvement in design and biocompatibility of the equipment, which has reduced the morbidity associated with this modality. Whilst the use of ECMO in neonatal population has been supported by numerous studies, the evidence upon which ECMO was integrated into adult practice was substantially less robust. Results: Recent data, including the CESAR study (Conventional Ventilatory Support versus Extra corporeal membrane oxygenation for Severe Respiratory failure) has added a degree of evidence to the role of ECMO in such a patient population. The CESAR study analysed 180 patients, and confirmed that ECMO was associated with an improved rate of survival. More recently, ECMO has been utilized in numerous situations within the critical care area, including support in high-risk percutaneous interventions in cardiac catheter lab; the operating room, emergency department, as well in specialized inter-hospital retrieval services. The increased understanding of the risk:benefit profile of ECMO, along with a reduction in morbidity associated with its use will doubtless lead to a substantial rise in the utilisation of this modality. As with all extra-corporeal circuits, ECMO opposes the basic premises of the mammalian inflammation and coagulation cascade where blood comes into foreign circulation, both these cascades are activated. Anti-coagulation is readily dealt with through use of agents such as heparin, but the inflammatory excess, whilst less macroscopically obvious, continues un-abated. Platelet consumption and neutrophil activation occur rapidly, and the clinician is faced with balancing the need of anticoagulation for the circuit, against haemostasis in an acutely bleeding patient. Alterations in pharmacokinetics may result in inadequate levels of disease modifying therapeutics, such as antibiotics, hence paradoxically delaying recovery from conditions such as pneumonia. Key elements of nutrition and the innate immune system maysimilarly be affected. Summary: This presentation will discuss the basic features of ECMO to the nonspecialist, and review the clinical conundrum faced by the team treating these most complex cases.