981 resultados para newborn care
Resumo:
Abstract : Providing high-quality clinical experiences to prepare students for the complexities of the current health-care system has become a challenge for nurse educators. Additionally, there are concerns that the current model of clinical practice is suboptimal. Consequently, nursing programs have explored the partial replacement of traditional in-hospital clinical experiences with a simulated clinical experience. Despite research demonstrating numerous benefits to students following participation in simulation activities, insufficient research conducted within Québec exists to convince the governing bodies (Ordre des infirmières et des infirmiers du Québec, OIIQ; Ministère de L’Éducation supérieur, de la Recherche, de la Science et de la Technologie) to fully embrace simulation as part of nurse training. The purpose of this study was to examine the use of a simulated clinical experience (SCE) as a viable, partial pedagogical substitute for traditional clinical experience by examining the effects of a SCE on CEGEP nursing students’ perceptions of self-efficacy (confidence), and their ability to achieve course objectives. The findings will contribute new information to the current body of research in simulation. The specific case of obstetrical practice was examined. Based on two sections of the Nursing III-Health and Illness (180-30K-AB) course, the sample was comprised of 65 students (thirty-one students from section 0001 and thirty-four students from section 0002) whose mean age was 24.8 years. With two sections of the course available, the opportunity for comparison was possible. A triangulation mixed method design was used. An adapted version of Ravert’s (2004) Nursing Skills for Evaluation tool was utilized to collect data regarding students’ perceptions of confidence related to the nursing skills required for care of mothers and their newborns. Students’ performance and achievement of course objectives was measured through an Objective Structured Clinical Examination (OSCE) consisting of three marked stations designed to test the theoretical and clinical aspects of course content. The OSCE was administered at the end of the semester following completion of the traditional clinical experience. Students’ qualitative comments on the post -test survey, along with journal entries served to support the quantitative scale evaluation. Two of the twelve days (15 hours) allocated for obstetrical clinical experience were replaced by a SCE (17%) over the course of the semester. Students participated in various simulation activities developed to address a range of cognitive, psychomotor and critical thinking skills. Scenarios incorporating the use of human patient simulators, and designed using the Jeffries Framework (2005), exposed students to the care of families and infants during the perinatal period to both reflect and build upon class and course content in achievement of course objectives and program competencies. Active participation in all simulation activities exposed students to Bandura’s four main sources of experience (mastery experiences, vicarious experiences, social persuasion, and physiologic/emotional responses) to enhance the development of students’ self-efficacy. Results of the pre-test and post-test summative scores revealed a statistically significant increase in student confidence in performing skills related to maternal and newborn care (p < .0001) following participation in the SCE. Confidence pre-test and post-test scores were not affected by the students’ section. Skills related to the care of the post-partum mother following vaginal or Caesarean section delivery showed the greatest change in confidence ratings. OSCE results showed a mean total class score (both sections) of 57.4 (70.0 %) with normal distribution. Mean scores were 56.5 (68.9%) for section 0001 and 58.3 (71.1%) for section 0002. Total scores were similar between sections (p =0.342) based on pairwise comparison. Analysis of OSCE scores as compared to students’ final course grade revealed similar distributions. Finally, qualitative analysis identified how students’ perceived the SCE. Students cited gains in knowledge, development of psychomotor skills and improved clinical judgement following participation in simulation activities. These were attributed to the « hands on » practice obtained from working in small groups, a safe and authentic learning environment and one in which students could make mistakes and correct errors as having the greatest impact on learning through simulation.
Resumo:
Antecedentes. La ejecución de las Normas de Bioseguridad, es una responsabilidad de la institución donde se incluye a todos los funcionarios. En el servicio de partos existen elementos nocivos o potencialmente peligrosos, como los productos biológicos provenientes de los pacientes y los reactivos químicos de diferente naturaleza. Es necesario reconocer estos peligros para establecer y aplicar medidas de prevención y seguridad (1). Objetivo: Determinar los conocimientos, actitudes y prácticas del personal médico y de enfermería en la sala de partos del hospital José Carrasco Arteaga, en la aplicación de las normas de bioseguridad en la atención del recién nacido, Cuenca 2015. Material y métodos: Se realizó un estudio cuantitativo - descriptivo, la muestra estaba constituida por 50 profesionales de la sala de partos del Hospital José Carrasco Arteaga. Las técnicas de investigación fueron la encuesta, la observación y la revisión bibliográfica, los instrumentos utilizados fueron ficha de registro, y la encuesta. Los resultados fueron analizados en tablas simples y de contingencia mediante los programas de Word. Excel y SPSS versión 21. Resultados: el 98% del personal desecha correctamente el material corto punzantes, el 86% del personal siempre lava sus manos antes y después de atender a la madre. Conclusiones: Al finalizar podemos decir que el 98% de los profesionales conoce lo que es bioseguridad, pero el 80% de los profesionales no aplica estas normas en el servicio. Para mejorar esto se debe elaborar y mejorar estrategias de capacitación.
Resumo:
Neonatology has optimized medical outcomes for high-risk newborns yet neurodevelopmental outcomes continue to be a concern. Basic science, clinical research, and environmental design perspectives have shown the impact of the caregiving environment on the developing brain and the role of professional caregivers in providing supportive intervention to both infants and their families. This recognition has prompted a focus on early developmentally supportive care (DSC) for high-risk newborns both in the hospital and in community follow up. DSC has emerged as a recognized standard of care in most neonatal intensive care units. Still, many questions remain and much integrative research is needed.
Resumo:
The Newborn Individualized Developmental Care and Assessment Program (NIDCAP) is widely used in neonatal intensive care units and comprises 85 discrete infant behaviors, some of which may communicate infant distress. The objective of this study was to identify developmentally relevant movements indicative of pain in preterm infants.
Resumo:
A number of medical and social developments have had an impact on the neonatal mortality over the past ten to 15 years in the United States. The purpose of this study was to examine one of these developments, Newborn Intensive Care Units (NICUs), and evaluate their impact on neonatal mortality in Houston, Texas.^ This study was unique in that it used as its data base matched birth and infant death records from two periods of time: 1958-1960 (before NICUs) and 1974-1976 (after NICUs). The neonatal mortality of single, live infants born to Houston resident mothers was compared for two groups: infants born in hospitals which developed NICUs and infants born in all other Houston hospitals. Neonatal mortality comparisons were made using the following birth-characteristic variables: birthweight, gestation, race, sex, maternal age, legitimacy, birth order and prenatal care.^ The results of the study showed that hospitals which developed NICUs had a higher percentage of their population with high risk characteristics. In spite of this, they had lower neonatal mortality rates in two categories: (1) white 3.5-5.5 pounds birthweight infants, (2) low birthweight infants whose mothers received no prenatal care. Black 3.5-5.5 pounds birthweight infants did equally well in either hospital group. While the differences between the two hospital groups for these categories were not statistically significant at the p < 0.05 level, data from the 1958-1960 period substantiate that a marked change occurred in the 3.5-5.5 pounds birthweight category for those infants born in hospitals which developed NICUs. Early data were not available for prenatal care. These findings support the conclusion that, in Houston, NICUs had some impact on neonatal mortality among moderately underweight infants. ^
Resumo:
This paper discusses the issues of parents and nurses when mulitples are admitted to busy NICU's
Resumo:
Ultrasound screening is now a routine procedure which forms part of antenatal care provision. Within this routine context ultrasound technology has been found to be generally acceptable and indeed is positively demanded by many women. This paper raises the question whether the routine presentation of ultrasound implicitly conveys the message that is use in antenatal care is both valuable and safe. It examines women's views of ultrasound technology beyond a routine context. In a study designed to examine women's reactions to cerebral ultrasound on their normal term infants mothers were asked their views and knowledge of ultrasound and a comparison with their antenatal experience of ultrasound was elicited. A generalized concern about ultrasound techniques was found to underlie many of the women's comments. This raised questions concerning the current practice in the presentation of ultrasound to women attending for antenatal care.
Resumo:
The aim of the present thesis was to study the role of the epithelial sodium channel (ENaC) in clearance of fetal lung fluid in the newborn infant by measurement of airway epithelial expression of ENaC, of nasal transepithelial potential difference (N-PD), and of lung compliance (LC). In addition, the effect of postnatal dexamethasone on airway epithelial ENaC expression was measured in preterm infants with bronchopulmonary dysplasia (BPD). The patient population was formed of selected term newborn infants born in the Department of Obstetrics (Studies II-IV) and selected preterm newborn infants treated in the neonatal intensive care unit of the Hospital for Children and Adolescents (Studies I and IV) of the Helsinki University Central Hospital in Finland. A small population of preterm infants suffering from BPD was included in Study I. Studies I, III, and IV included airway epithelial measurement of ENaC and in Studies II and III, measurement of N-PD and LC. In Study I, ENaC expression analyses were performed in the Research Institute of the Hospital for Sick Children in Toronto, Ontario, Canada. In the following studies, analyses were performed in the Scientific Laboratory of the Hospital for Children and Adolescents. N-PD and LC measurements were performed at bedside in these hospitals. In term newborn infants, the percentage of amiloride-sensitive N-PD, a surrogate for ENaC activity, measured during the first 4 postnatal hours correlates positively with LC measured 1 to 2 days postnatally. Preterm infants with BPD had, after a therapeutic dose of dexamethasone, higher airway epithelial ENaC expression than before treatment. These patients were subsequently weaned from mechanical ventilation, probably as a result of the clearance of extra fluid from the alveolar spaces. In addition, we found that in preterm infants ENaC expression increases with gestational age (GA). In preterm infants, ENaC expression in the airway epithelium was lower than in term newborn infants. During the early postnatal period in those born both preterm and term airway epithelial βENaC expression decreased significantly. Term newborn infants delivered vaginally had a significantly smaller airway epithelial expression of αENaC after the first postnatal day than did those delivered by cesarean section. The functional studies showed no difference in N-PD between infants delivered vaginally and by cesarean section. We therefore conclude that the low airway epithelial expression of ENaC in the preterm infant and the correlation of N-PD with LC in the term infant indicate a role for ENaC in the pathogenesis of perinatal pulmonary adaptation and neonatal respiratory distress. Because dexamethasone raised ENaC expression in preterm infants with BPD, and infants were subsequently weaned from ventilator therapy, we suggest that studies on the treatment of respiratory distress in the preterm infant should include the induction of ENaC activity.
Resumo:
The coagulation system of newborn infants differs markedly from that of older children and adults. The activities of most coagulation factors and anticoagulants are low, leading to altered regulation in the formation of the key enzyme, thrombin. Timely and adequate generation of thrombin is essential, as thrombin activates platelets and many coagulation factors, cleaves fibrinogen into fibrin and activates the antithrombotic and anti-inflammatory protein C pathway. On the other hand, excess thrombin may promote thrombotic complications and exacerbate harmful inflammatory reactions. Despite the characteristic features, the newborn coagulation system can be considered physiological, since healthy newborns rarely show haemorrhagic or thrombotic complications. Sick newborns, however, often encounter clinical situations that challenge their coagulation system. The aim of this study was to clarify the behaviour of the neonatal coagulation system in selected clinical situations, with a special emphasis on the generation of thrombin. Thrombin was measured by in vivo thrombin generation markers and by thrombin generation potential in vitro. The patient groups included sick newborns undergoing intensive care and receiving fresh-frozen plasma (FFP), requiring exchange transfusions (ET) or presenting with a congenital heart defect requiring open heart surgery. Additionally, healthy newborns with inherited heterozygous factor V Leiden (FVL) mutation were studied. Thrombin generation potential was also analysed in cord plasma of healthy infants and in adults. Healthy as well as sick newborn infants showed lower total thrombin generation potential in vitro but faster initiation of thrombin generation than adults. These findings were qualitatively similar when plasma was supplemented with platelets. Platelets, however, significantly altered the effect of the major anticoagulant, activated protein C (APC), on thrombin generation potential. In accordance with previous studies, thrombin generation in healthy newborn platelet-poor plasma was resistant to the anticoagulant effects of APC, but when the plasma was supplemented with platelets APC attenuated thrombin generation significantly more in newborns than in adults. In vivo generation of thrombin was elevated in nearly all of the sick newborn infants. The low-volume FFP transfusion as opposed to the change from neonatal to adult blood in ET exerted markedly different effects on neonatal thrombin generation. FFP reduced the in vivo generation of thrombin in those newborns with the highest pretransfusional thrombin generation, thus acting as an anticoagulant agent. In those infants with lower pretransfusional thrombin generation, the effect of FFP on thrombin generation was fairly neutral. On the other hand, the combination of red blood cells and FFP, used to perform ET, significantly increased the in vivo thrombin formation and shifted the balance in the newborn coagulation system to the procoagulant direction. Cardiopulmonary bypass (CPB) also significantly increased the in vivo thrombin generation, but the thrombin generation profile during CPB differed from that previously observed in adults. Escalation of thrombin at early reperfusion was not observed in newborns; in adults, its occurrence is associated with postoperative myocardial damage. Finally, in healthy newborns with FVL heterozygosity, faster initiation of thrombin generation was observed compared with controls. Interestingly, FV level was lower in FVL-heterozygous infants, possibly to counteract the procoagulant effects induced by FVL. In conclusion, unique features regarding thrombin regulation in newborn infants were observed. These features included a novel platelet effect on the regulation of the protein C pathway. The clinical challenges mainly seemed to shift the balance in the coagulation system of newborns to the procoagulant direction. Blood component transfusions markedly affected coagulation in a manner specific to the product but that could also be altered by the clinical situation. Overall, the results highlight the need for understanding developmental haemostasis for both diagnostic and therapeutic purposes.
Resumo:
Evidence-based thermal care recommendations designed to minimize heat loss immediately at birth are readily available however, hypothermia still persists as a global challenge especially when caring for the most immature and smallest preterm infants. In this narrative overview we aim to provide the reader with a succinct summary of the causes and consequences of hypothermia, the extent of the problem (rates of hypothermia), principles of good thermal care, delivery room preventative measures, the research evidence underpinning existing interventions, current issues in practice, and the way forward. Due to the plethora of research literature available in this subject area, our article will focus primarily on evidence derived from systematic reviews and randomized or quasi-randomized controlled trials assessing the effectiveness of interventions to prevent hypothermia in the most vulnerable (preterm/low birth weight) infants where the intervention or combination of interventions is applied immediately at birth. © 2014.
Resumo:
Background
Mechanical ventilation is a life-saving intervention for critically ill newborn infants with respiratory failure admitted to a neonatal intensive care unit (NICU). Ventilating newborn infants can be challenging due to small tidal volumes, high breathing frequencies, and the use of uncuffed endotracheal tubes. Mechanical ventilation has several short-term, as well as long-term complications. To prevent complications, weaning from the ventilator is started as soon as possible. Weaning aims to support the transfer from full mechanical ventilation support to spontaneous breathing activity.
Objectives
To assess the efficacy of protocolized versus non-protocolized ventilator weaning for newborn infants in reducing the duration of invasive mechanical ventilation, the duration of weaning, and shortening the NICU and hospital length of stay. To determine efficacy in predefined subgroups including: gestational age and birth weight; type of protocol; and type of protocol delivery. To establish whether protocolized weaning is safe and clinically effective in reducing the duration of mechanical ventilation without increasing the risk of adverse events.
Search methods
We searched the Cochrane Central Register of Controlled trials (CENTRAL; the Cochrane Library; 2015, Issue 7); MEDLINE In-Process and other Non-Indexed Citations and OVID MEDLINE (1950 to 31 July 2015); CINAHL (1982 to 31 July 2015); EMBASE (1988 to 31 July 2015); and Web of Science (1990 to 15 July 2015). We did not restrict language of publication. We contacted authors of studies with a subgroup of newborn infants in their study, and experts in the field regarding this subject. In addition, we searched abstracts from conference proceedings, theses, dissertations, and reference lists of all identified studies for further relevant studies.
Selection criteria
Randomized, quasi-randomized or cluster-randomized controlled trials that compared protocolized with non-protocolized ventilator weaning practices in newborn infants with a gestational age of 24 weeks or more, who were enrolled in the study before the postnatal age of 28 completed days after the expected date of birth.
Data collection and analysis
Four authors, in pairs, independently reviewed titles and abstracts identified by electronic searches. We retrieved full-text versions of potentially relevant studies.
Main results
Our search yielded 1752 records. We removed duplicates (1062) and irrelevant studies (843). We did not find any randomized, quasi-randomized or cluster-randomized controlled trials conducted on weaning from mechanical ventilation in newborn infants. Two randomized controlled trials met the inclusion criteria on type of study and type of intervention, but only included a proportion of newborns. The study authors could not provide data needed for subgroup analysis; we excluded both studies.
Authors' conclusions
Based on the results of this review, there is no evidence to support or refute the superiority or inferiority of weaning by protocol over non-protocol weaning on duration of invasive mechanical ventilation in newborn infants.
Resumo:
OBJECTIVE:: Report of a 16q24.1 deletion in a premature newborn, demonstrating the usefulness of array-based comparative genomic hybridization in persistent pulmonary hypertension of the newborn and multiple congenital malformations. DESIGN:: Descriptive case report. SETTING:: Genetic department and neonatal intensive care unit of a tertiary care children's hospital. INTERVENTIONS:: None. PATIENT:: We report the case of a preterm male infant, born at 26 wks of gestation. A cardiac malformation and bilateral hydronephrosis were diagnosed at 19 wks of gestation. Karyotype analysis was normal, and a 22q11.2 microdeletion was excluded by fluorescence in situ hybridization analysis. A cesarean section was performed due to fetal distress. The patient developed persistent pulmonary hypertension unresponsive to mechanical ventilation and nitric oxide treatment and expired at 16 hrs of life. MEASUREMENTS AND MAIN RESULTS:: An autopsy revealed partial atrioventricular canal malformation and showed bilateral dilation of the renal pelvocaliceal system with bilateral ureteral stenosis and annular pancreas. Array-based comparative genomic hybridization analysis (Agilent oligoNT 44K, Agilent Technologies, Santa Clara, CA) showed an interstitial microdeletion encompassing the forkhead box gene cluster in 16q24.1. Review of the pulmonary microscopic examination showed the characteristic features of alveolar capillary dysplasia with misalignment of pulmonary veins. Some features were less prominent due to the gestational age. CONCLUSIONS:: Our review of the literature shows that alveolar capillary dysplasia with misalignment of pulmonary veins is rare but probably underreported. Prematurity is not a usual presentation, and histologic features are difficult to interpret. In our case, array-based comparative genomic hybridization revealed a 16q24.1 deletion, leading to the final diagnosis of alveolar capillary dysplasia with misalignment of pulmonary veins. It emphasizes the usefulness of array-based comparative genomic hybridization analysis as a diagnostic tool with implications for both prognosis and management decisions in newborns with refractory persistent pulmonary hypertension and multiple congenital malformations.
Resumo:
We analyzed Brazil`s efforts in reducing child mortality, improving maternal and child health, and reducing socioeconomic and regional inequalities from 1990 through 2007. We compiled and reanalyzed data from several sources, including vital statistics and population-based surveys. We also explored the roles of broad socioeconomic and demographic changes and the introduction of health sector and other reform measures in explaining the improvements observed. Our findings provide compelling evidence that pro-active measures to reduce health disparities accompanied by socioeconomic progress can result in measurable improvements in the health of children and mothers in a relatively short interval. Our analysis of Brazil`s successes and remaining challenges to reach and surpass Millennium Development Goals 4 and 5 can provide important lessons for other low- and middle-income countries. (Am J Public Health. 2010;100:1877-1889. doi:10.2105/AJPH.2010.196816)
Resumo:
We describe a cross-sectional, survey to identify risk factors for colonisation of neonates by extended-spectrum P-Lactamase (ESBL)-producing Klebsiella pneumoniae. This occurred following exposure to a colonised healthcare worker during an outbreak in an intermediate-risk neonatal. unit. In total, 120 neonates admitted consecutively during a three-month period were screened for ESBL-producing K. pneumoniae by rectal swabbing and 27 were identified as colonised. Multivariate analysis showed colonisation to be independently associated with use of antibiotics and absence of breastfeeding. Previous use of antibiotics presented an odds ratio (OR) of 12.3 [95% confidence interval. (Cl): 3.66-41.2, P < 0.001]. The most commonly used antibiotics were penicillin and amikacin. Breastfeeding was associated with reduced risk for colonisation (OR: 0.22; 95% Cl: 0.05-0.99; P = 0.049). Nine isotates recovered during the first stage of the outbreak and 27 isolates from surveillance cultures were typed thereafter by pulsed-field gel electrophoresis, revealing six different profiles (A-F). Clones A, C, and E were implicated in the first stage of the outbreak, whereas among the 27 strains recovered from surveillance cultures, all six clones were identified. Clone A was also found on the hand of a nursing auxiliary with onychomycosis. We concluded that prior antimicrobial use predisposed to colonisation. The possible role of breastfeeding as a protective factor needs to be further elucidated. Detection of different genotypes of ESBL-producing K. pneumonioe suggests that dissemination of mobile genetic elements bearing the ESBL gene may have been superimposed on the simple dissemination of a clone during the outbreak. (c) 2008 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Resumo:
Every mother and child has the right to survive childbirth which requires skilled birth attendants together with referral and available emergency obstetric care (EmOC). The objective of the study was to describe delivery care routines at different levels in the health care system in Quang Ninh province, Northern Vietnam. The design was cross sectional using a structured questionnaire. Two districts in Quang Ninh province with 40 Community Health Centres (CHC), three district hospitals and one region hospital was included in the study, in total 138 (CHC n=105 and hospitals n=33) health care providers participated. In our study 20% (CHC) of the health care providers assisting deliveries at CHC were midwives and health care provider’s in our study further report to have assisted at less then 10 deliveries/year (81% of respondents at CHC). Findings show that the health care provider’s routines and care for women during labour and delivery vary and that there is a need for re-training and that women in labour should be cared for by health care providers with adequate training like midwifery. In our study CHC had poor resources to provide basic or comprehensive EmOC. Our findings indicate that there is a need for re-training in delivery care among health care providers and since the number of deliveries at CHC is few they should be handled by someone who is a skilled birth attendant. Our findings also show a variation in care routines during labour and delivery among health care providers at CHC and hospital levels and this also show the need for re-training and support from proper authorities in order to improve maternal and newborn health.