986 resultados para mitral valve regurgitation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An unusual case of localized amyloid light-chain (AL) amyloidosis and extramedullary plasmacytoma of the mitral valve is described. The worsening of a mitral regurgitation led to investigations and surgery. The valve presented marked distortion and thickening by type AL amyloid associated with a monotypic CD138+ immunoglobulin lambda plasma cell proliferation. Systemic staging showed a normal bone marrow and no evidence of amyloid deposition in other localizations. The patient's outcome after mitral valve replacement was excellent. To our knowledge, this is the first description of a localized AL amyloidosis as well as of a primary extramedullary plasmacytoma of the mitral valve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The study aimed to evaluate the feasibility of off-pump transapical mitral valve-in-ring implantation and to test the performance of a custom-made self-expandable stent valve, in comparison with the standard SAPIEN valve. METHODS: Acute experiments were performed in five pigs. Animals (mean weight 58.4 ± 7.3 kg) underwent mitral valve annuloplasties under cardiopulmonary bypass using 26-mm rings (SJM?). Then, a 30-mm custom-made self-expandable stent valve or a 23-mm balloon-expandable transcatheter heart valve (Edwards SAPIEN XT?) was deployed within the annuloplasty rings through a transatrial access and under direct vision. Subsequently, the stent valves were inserted transapically under fluoroscopic guidance and off pump. RESULTS: The procedural success of transatrial and transapical mitral valve-in-ring procedures was 100% (10 of 10). Mean transatrial and transapical procedure time was 2.0 ± 1.1 and 22.0 ± 5.7 min, respectively. Haemodynamic status during transapical implantation remained stable, and differences in data collected before and after the stent-valve deployment were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area in the group of self-expandable stent valves were 2.60 ± 0.02 cm and 4.16 ± 0.48 cm(2), respectively, whereas in the SAPIEN group they were 1.95 ± 0.18 cm and 2.26 ± 0.20 cm(2), respectively. Trace or mild regurgitation was detected only in the self-expandable stent-valve group. Mean gradients were 4.1 ± 4.5 mmHg across the self-expandable stent valves and 1.0 ± 0 mmHg across the SAPIEN valves. Postmortem examination confirmed adequate positioning of the self-expandable valves and the SAPIEN valves within the annuloplasty ring. CONCLUSIONS: Off-pump transapical mitral valve-in-ring implantation is safe and feasible. Transapical access may represent the ideal option for valve-in-ring procedures in cases of recurrent mitral regurgitation after mitral valve repair, in high-risk patients. Owing to the supra-annular profile of the valve components, our custom-made nitinol stent valve provides nearer to normal functional area than the SAPIEN valve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An unusual case of localized amyloid light-chain (AL) amyloidosis and extramedullary plasmacytoma of the mitral valve is described. The worsening of a mitral regurgitation led to investigations and surgery. The valve presented marked distortion and thickening by type AL amyloid associated with a monotypic CD138+ immunoglobulin lambda plasma cell proliferation. Systemic staging showed a normal bone marrow and no evidence of amyloid deposition in other localizations. The patient's outcome after mitral valve replacement was excellent. To our knowledge, this is the first description of a localized AL amyloidosis as well as of a primary extramedullary plasmacytoma of the mitral valve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Transcatheter aortic valve implantation (TAVI) has demonstrated the feasibility of treating valvular heart disease with transcatheter therapy. On the back of this success, various transcatheter concepts are being evaluated to treat other valvular disease, especially mitral regurgitation (MR). The concepts currently approved to treat MR replicate surgical mitral valve repair. However, most of them cannot eliminate MR completely. Similar to TAVI, a transcatheter mitral valve implantation may provide a valuable alternative. The FORTIS transcatheter mitral valve (Edwards Lifesciences, Irvine, CA, USA) is a self-expanding device implanted via a transapical approach. We describe our experience and early results in the first five patients treated on compassionate grounds. We also describe the details of the device, selection criteria and technical details of implantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The use of transcatheter mitral valve repair (TMVR) has gained widespread acceptance in Europe, but data on immediate success, safety, and long-term echocardiographic follow-up in real-world patients are still limited. OBJECTIVES The aim of this multinational registry is to present a real-world overview of TMVR use in Europe. METHODS The Transcatheter Valve Treatment Sentinel Pilot Registry is a prospective, independent, consecutive collection of individual patient data. RESULTS A total of 628 patients (mean age 74.2 ± 9.7 years, 63.1% men) underwent TMVR between January 2011 and December 2012 in 25 centers in 8 European countries. The prevalent pathogenesis was functional mitral regurgitation (FMR) (n = 452 [72.0%]). The majority of patients (85.5%) were highly symptomatic (New York Heart Association functional class III or higher), with a high logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) (20.4 ± 16.7%). Acute procedural success was high (95.4%) and similar in FMR and degenerative mitral regurgitation (p = 0.662). One clip was implanted in 61.4% of patients. In-hospital mortality was low (2.9%), without significant differences between groups. The estimated 1-year mortality was 15.3%, which was similar for FMR and degenerative mitral regurgitation. The estimated 1-year rate of rehospitalization because of heart failure was 22.8%, significantly higher in the FMR group (25.8% vs. 12.0%, p[log-rank] = 0.009). Paired echocardiographic data from the 1-year follow-up, available for 368 consecutive patients in 15 centers, showed a persistent reduction in the degree of mitral regurgitation at 1 year (6.0% of patients with severe mitral regurgitation). CONCLUSIONS This independent, contemporary registry shows that TMVR is associated with high immediate success, low complication rates, and sustained 1-year reduction of the severity of mitral regurgitation and improvement of clinical symptoms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To validate a self-expanding transcatheter valve for off-pump transatrial mitral valve-in-ring (VIR) implantation via a left thoracotomy. METHODS Mitral valve annuloplasty was performed via sternotomy during cardiopulmonary bypass on 9 pigs. After successful weaning from extracorporal circulation, the custom-made, self-expanding transcatheter VIR device was deployed under fluoroscopic guidance within the annuloplasty ring via a left thoracotomy. Hemodynamic data before and after the implantation were recorded. Mitral annulus diameter and valve area were measured by echocardiography. Transvalvular and left-ventricular outflow-tract pressure gradient were measured invasively. RESULTS Eight successful implantations were performed. Implantation failed in 1 pig because of difficulty with technical delivery of the sheath. Mean transatrial procedure time was 12.6 ± 1.7 min. Hemodynamic status during transatrial implantation was stable, and differences were not statistically significant. Mean mitral annulus diameter and mean mitral orifice area were 2.32 ± 0.2 and 3.84 ± 0.55 cm2, respectively. Mild regurgitation was detected in 7 animals and moderate regurgitation in 1. Mean gradients were 6.1 ± 5.0 mm Hg across the device. Postmortem examination confirmed adequate positioning of devices within the annuloplasty ring. CONCLUSIONS This custom-made transcatheter device allows for safe and reproducible off-pump transatrial mitral VIR implantations. Transatrial access is a promising route to facilitate VIR implantations. Our custom-made stent-valve may be suitable for VIR procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS Transcatheter mitral valve replacement (TMVR) is an emerging technology with the potential to treat patients with severe mitral regurgitation at excessive risk for surgical mitral valve surgery. Multimodal imaging of the mitral valvular complex and surrounding structures will be an important component for patient selection for TMVR. Our aim was to describe and evaluate a systematic multi-slice computed tomography (MSCT) image analysis methodology that provides measurements relevant for transcatheter mitral valve replacement. METHODS AND RESULTS A systematic step-by-step measurement methodology is described for structures of the mitral valvular complex including: the mitral valve annulus, left ventricle, left atrium, papillary muscles and left ventricular outflow tract. To evaluate reproducibility, two observers applied this methodology to a retrospective series of 49 cardiac MSCT scans in patients with heart failure and significant mitral regurgitation. For each of 25 geometrical metrics, we evaluated inter-observer difference and intra-class correlation. The inter-observer difference was below 10% and the intra-class correlation was above 0.81 for measurements of critical importance in the sizing of TMVR devices: the mitral valve annulus diameters, area, perimeter, the inter-trigone distance, and the aorto-mitral angle. CONCLUSIONS MSCT can provide measurements that are important for patient selection and sizing of TMVR devices. These measurements have excellent inter-observer reproducibility in patients with functional mitral regurgitation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulmonary hypertension represents an important cause of morbidity and mortality in patients with mitral stenosis who undergo cardiac surgery, especially in the postoperative period. The aim of this study was to test the hypothesis that inhaled nitric oxide (iNO) would improve the hemodynamic effects and short-term clinical outcomes of patients with mitral stenosis and severe pulmonary hypertension who undergo cardiac surgery in a randomized, controlled study. Twenty-nine patients (4 men, 25 women; mean age 46 2 years) were randomly allocated to receive iNO (n = 14) or oxygen (n = 15) for 48 hours immediately after surgery. Hemodynamic data, the use of vasoactive drugs, duration of stay, and short-term complications were assessed. No differences in baseline characteristics were observed between the groups. After 24 and 48 hours, patients receiving iNO had a significantly greater increase in cardiac index compared to patients receiving oxygen (p < 0.0001). Pulmonary vascular resistance was also more significantly reduced in patients receiving iNO versus oxygen (-117 dyne/s/cm(5), 95% confidence interval 34 to 200, vs 40 dyne/s/cm5, 95% confidence interval 34 to 100, p = 0.005) at 48 hours. Patients in the iNO group used fewer systemic vasoactive drugs.(mean 2.1 +/- 0.14 vs 2.6 +/- 0.16, p = 0.046) and had a shorter intensive care unit stay (median 2 days, interquartile range 0.25, vs median 3 days, interquartile range 7, p = 0.02). In conclusion, iNO immediately after surgery in patients with mitral stenosis and severe pulmonary hypertension improves hemodynamics and may have short-term clinical benefits. (C) 2011 Elsevier Inc. All rights reserved. (Am J Cardiol 2011;107:1040-1045)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigated whether there is an association between anxiety disorders and mitral valve prolapse. We compared mitral valve prolapse prevalence in individuals with panic disorder (n=41), social anxiety disorder (n=89) and in healthy controls (n=102) in an attempt to overcome the biases of previous studies. Our results show no associations between panic disorder or social anxiety disorder and mitral valve prolapse, regardless of the diagnostic criteria employed, and that the relationship between these conditions seems not to be clinically relevant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Primary tumours of the heart are uncommon entities, cardiac myxomas being the most frequent. However, mitral valve myxomas are exceptionally rare. In the last 12 years, there have been 25 myxomas diagnosed at our institution, with only two of them originating from the mitral valve. Both patients were female, the first, 25, and the second, 72 years old. The younger patient was very symptomatic with a large mass, 4 cm long, which involved both leaflets causing significant obstruction to the left ventricular inflow. The second one had a smaller mass located at the atrial side of the posterior leaflet that only produced some flow divergence. Neither of them had constitutional nor embolic symptoms. Both patients were submitted to emergent surgical resection that in the first case involved the mitral valve and replacement with mechanical prosthesis. The macroscopic appearance of these tumours suggested a malignant aetiology which may represent somewhat different features of the myxomas when originating from the cardiac valves. Both patients are well reflecting the good prognosis of this illness after resection, although the younger patient was re-operated because of prosthetic valve obstruction and suspicion of recurrence that was not confirmed. Because of the illustrative images and different presentations, we found it interesting to report and discuss them together.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Pregnant women with mechanical prosthetic heart valves are at increased risk for valve thrombosis. Management decisions for this life-threatening complication are complex. Open-heart surgery has a very high risk of maternal mortality and fetal loss. Bleeding and embolic risks associated with thrombolytic agents, the limited efficacy of thrombolysis in certain subgroups, and a lack of experience in the setting of pregnancy raise important concerns. CASE REPORT: We report a case of mitral prosthetic valve thrombosis in early pregnancy, which was successfully treated with streptokinase. Ten years later, the same patient had an uneventful pregnancy, throughout which acenocoumarol was maintained. CONCLUSION: With this case we review the prevention (with oral anticoagulant therapy) and treatment of prosthetic valve thrombosis during pregnancy, which is important for both obstetrician and cardiologist.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Descrever os achados ao ecocardiograma transesofágico e evolução clínica de portadores de flail mitral valve. MÉTODOS: No período de janeiro/93 a março/97, 1675 pacientes foram submetidos, em nossa instituição, a ecocardiograma transesofágico, sendo que em 35 casos foi feito o diagnóstico de flail mitral valve e, posteriormente, obtida sua evolução clínica. RESULTADOS: A idade dos pacientes variou 12 a 87 anos (média 65±15) e 27 (77%) eram do sexo masculino. O folheto posterior foi o mais acometido (25 pacientes, 71%). O mecanismo do flail foi ruptura de cordoalha tendínea em todos os casos, exceto um, que apresentava importante alongamento e redundância de cordoalha. A etiologia foi prolapso e/ou degeneração mixomatosa em 15 pacientes, degenerativa em 9, isquêmica em 5, reumática em 4 e endocardite em 3. Regurgitação mitral de grau importante ocorreu em 25 (71%) pacientes e moderada em 10 (29%). O tempo médio de acompanhamento foi de 375±395 dias (1 a 1380). Foram submetidos a tratamento clínico 19 pacientes e a tratamento cirúrgico 16, sendo que em todos foi confirmado o diagnóstico transesofágico. O número total de óbitos (hospitalar e pós-hospitalar) foi alto (34%), tanto em pacientes submetidos a tratamento clínico quanto cirúrgico. Entre os sobreviventes, 17 estão em classe funcional (CF) I e 6 em CF II da NYHA. CONCLUSÃO: O diagnóstico de flail mitral valve ao ecocardiograma transesofágico é acurado, permitindo a definição de sua etiologia e mecanismo. A alta mortalidade à época do diagnóstico, provavelmente, se relaciona à gravidade da doença subjacente. Embora os pacientes não operados estejam evoluindo bem, a baixa CF observada nestes pacientes pode ser atribuída ao curto período de seguimento.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Only rarely do myxomas originate from the mitral valve. This is the report of a 49-year-old woman presenting with congestive heart failure. The diagnosis of an intracardiac tumor involving the anterior cuspid of the mitral valve was made by transesophageal echocardiography. The patient underwent surgery for tumor resection and plasty of the valve was made with reconstruction and preservation of the valve. The diagnosis of myxoma was confirmed by histology. This is the 23rd case of myxoma of the mitral valve reported in the literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE - To analyze the immediate and late results of mitral valve repair with quadrangular resection of the posterior leaflet without the use of a prosthetic ring annuloplasty. METHODS - Using this technique, 118 patients with mitral valve prolapse who underwent mitral repair from January '84 through December '96 were studied. Age ranged from 30 to 86 (mean = 59.1±11.8) years and 62.7% were males. An associated surgery was performed in 22% of the patients, and coronary artery bypass graft was the most frequently performed surgery (15 patients - 12.7%). In 20 (16.9%) patients other associated techniques of mitral valve repair were used and shortening of elongated chordae tendineae was the most frequent one (6 patients). RESULTS - Immediate mortality was 0.9% (one patient). Long-term rates for thromboembolism, endocarditis, re-operation and death in the late postoperative period were 0.4%, 0.4%, 1.7% and 2.2% patients/year, respectively. The actuarial curve of survival was 83.8±8.6% over 12 years; survival free from re-operation was 91.8±4.3%, free from endocarditis was 99.2±0.8% and free from thromboembolism was 99.2±0.8%. In the late postoperative period, 93.8% of the patients were in functional class 1 (NYHA), with a complete follow-up in 89.7% of the patients. CONCLUSION - Patients with mitral valve prolapse who undergo mitral valve repair using this technique have a satisfactory prognosis over 12 years.