904 resultados para liquid metal diffusion


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we present a new method for measuring diffusion coefficients in liquid metals under convection-less conditions with solid/liquid-liquid/solid trilayer. The advantage of this kind of trilayer is that effects from gravity-induced convection and Marangoni-convection can be omitted, so that the diffusion coefficient is determined more accurately. The Ta/Zn-Sn/Si trilayer were prepared with a multi-target ion-beam sputtering deposition technique and annealed in an electric furnace under an argon atmosphere. The interdiffusion of liquid zinc and tin at 500 degrees degree C was investigated. The diffusion concentration profiles were determined by energy dispersive spectroscopy. The interdiffusion coefficients range from 1.0x10(-6)cm(2)/s to 2.8x10(-6)cm(2)/s, which is less than previous values measured by capillary reservoir technique under 1g-environment where various convection exist. The precise interdiffusion coefficients of liquid zinc and tin result from the removing of disturbances of various kinds of convection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we present a new method for measuring diffusion coefficients in liquid metals under convection-less conditions with solid/liquid-liquid/solid trilayer. The advantage of this kind of trilayer is that effects from gravity-induced convection and Marangoni-convection can be omitted, so that the diffusion coefficient is determined more accurately. The Ta/Zn-Sn/Si trilayer were prepared with a multi-target ion-beam sputtering deposition technique and annealed in an electric furnace under an argon atmosphere. The interdiffusion of liquid zinc and tin at 500 degrees degree C was investigated. The diffusion concentration profiles were determined by energy dispersive spectroscopy. The interdiffusion coefficients range from 1.0x10(-6)cm(2)/s to 2.8x10(-6)cm(2)/s, which is less than previous values measured by capillary reservoir technique under 1g-environment where various convection exist. The precise interdiffusion coefficients of liquid zinc and tin result from the removing of disturbances of various kinds of convection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The liquid metal flow in induction crucible models is known to be unstable, turbulent and difficult to predict in the regime of medium frequencies when the electromagnetic skin-layer is of considerable extent. We present long term turbulent flow measurements by a permanent magnet incorporated potential difference velocity probe in a cylindrical container filled with eutectic melt In-Ga-Sn. The parallel numerical simulation of the long time scale development of the turbulent average flow is presented. The numerical flow model uses an implicit pseudo-spectral code and k-w turbulence model, which was recently developed for the transitional flow modelling. The results compare reasonably to the experiment and demonstrate the time development of the turbulent flow field and the turbulence energy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The liquid metal flow in inducation crucible models is known to be higly unstable and turbutlen in the regim e of medium frequecies when the elctronmagnetic skin-layer is of considerable extent. We present long term turbulent flow measurements by a permanent magnet incorporated potential difference veolocity probe in a cylindirical container filled with eutecti mlt In-Ga-SN. The parallel numerical simulation of the long time scale development of the turbulen average flow is presented. The numerical lfow model uses a pseud-spectral code and k-w turbulence model, which was recently developed for the transitional flow modelling. The result compare reasonably to the experiment and demonstrate the time development of the turbulent flow field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Electromagnetic levitation of electrically conductive droplets by alternating magnetic fields is a technique used to measure the physical properties of liquid metallic alloys such as surface tension or viscosity. Experiments can be conducted under terrestrial conditions or in microgravity, to reduce electromagnetic stirring and shaping of the droplet. Under such conditions, the time-dependent behaviour of a point of the free surface is recorded. Then the signal is analysed considering the droplet as a harmonic damped oscillator. We use a spectral code, for fluid flow and free surface descriptions, to check the validity of this assumption for two cases. First when the motion inside the droplet is generated by its initial distortion only and second, when the droplet is located in a uniform magnetic field originating far from the droplet. It is found that some deviations exist which can lead to an overestimate of the value of viscosity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The time dependent numerical model of cold crucible melting is based on the coupled electromagnetic, temperature and turbulent velocity field calculation accounting for the magnetically confined liquid metal shape continuous change. The model is applied to investigate the process energy efficiency dependence on the critical choice of AC power supply frequency and an optional addition of a DC magnetic field. Test cases of the metal load up to 50 kg are considered. The behaviour of the numerical model at high AC frequencies is instructively validated by the use of the electromagnetic analytical solution for a sphere and temperature measurements in a commercial size cold crucible furnace

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increase in the XUV mass absorption coefficient of liquid aluminium, produced by high-power-laser shock-compression, is measured using XUV laser radiography. At a photon energy of 63 eV a change in the mass absorption coefficient by up to a factor of similar to2.2 is determined at densities close to twice that of solid and electron temperatures of the order of 1 eV. Comparison with hydrodynamic simulations indicate that the absorption coefficient scales with density as rho (1.3 +/-0.2).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of liquid metal technology in fusion devices requires R&D related to many phenomena: interaction between liquid metals and structural material as corrosion, erosion and passivation techniques; magneto-hydrodynamics; free surface fluid-dynamics and any other physical aspect that will be needed for their safe reliable operation. In particular, there is a significant shortage of experimental facilities dedicated to the development of the lithium technology. In the framework of the TECHNOFUSION project, an experimental laboratory devoted to the lithium technology development is proposed, in order to shed some light in the path to IFMIF and the design of chamber's first wall and divertors. The conceptual design foresee a development in two stages, the first one consisting on a material testing loop. The second stage proposes the construction of a mock-up of the IFMIF target that will allow to assess the behaviour of a free-surface lithium target under vacuum conditions. In this paper, such conceptual design is addressed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"January 1960."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

August 1963.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"UC-41 Health and Safety ; TID-4500 (13th Ed., Suppl.)."