991 resultados para laboratory detection


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Major food adulteration and contamination events occur with alarming regularity and are known to be episodic, with the question being not if but when another large-scale food safety/integrity incident will occur. Indeed, the challenges of maintaining food security are now internationally recognised. The ever increasing scale and complexity of food supply networks can lead to them becoming significantly more vulnerable to fraud and contamination, and potentially dysfunctional. This can make the task of deciding which analytical methods are more suitable to collect and analyse (bio)chemical data within complex food supply chains, at targeted points of vulnerability, that much more challenging. It is evident that those working within and associated with the food industry are seeking rapid, user-friendly methods to detect food fraud and contamination, and rapid/high-throughput screening methods for the analysis of food in general. In addition to being robust and reproducible, these methods should be portable and ideally handheld and/or remote sensor devices, that can be taken to or be positioned on/at-line at points of vulnerability along complex food supply networks and require a minimum amount of background training to acquire information rich data rapidly (ergo point-and-shoot). Here we briefly discuss a range of spectrometry and spectroscopy based approaches, many of which are commercially available, as well as other methods currently under development. We discuss a future perspective of how this range of detection methods in the growing sensor portfolio, along with developments in computational and information sciences such as predictive computing and the Internet of Things, will together form systems- and technology-based approaches that significantly reduce the areas of vulnerability to food crime within food supply chains. As food fraud is a problem of systems and therefore requires systems level solutions and thinking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Substantial complexity has been introduced into treatment regimens for patients with human immunodeficiency virus (HIV) infection. Many drug-related problems (DRPs) are detected in these patients, such as low adherence, therapeutic inefficacy, and safety issues. We evaluated the impact of pharmacist interventions on CD4+ T-lymphocyte count, HIV viral load, and DRPs in patients with HIV infection. In this 18-month prospective controlled study, 90 outpatients were selected by convenience sampling from the Hospital Dia-University of Campinas Teaching Hospital (Brazil). Forty-five patients comprised the pharmacist intervention group and 45 the control group; all patients had HIV infection with or without acquired immunodeficiency syndrome. Pharmaceutical appointments were conducted based on the Pharmacotherapy Workup method, although DRPs and pharmacist intervention classifications were modified for applicability to institutional service limitations and research requirements. Pharmacist interventions were performed immediately after detection of DRPs. The main outcome measures were DRPs, CD4+ T-lymphocyte count, and HIV viral load. After pharmacist intervention, DRPs decreased from 5.2 (95% confidence interval [CI] =4.1-6.2) to 4.2 (95% CI =3.3-5.1) per patient (P=0.043). A total of 122 pharmacist interventions were proposed, with an average of 2.7 interventions per patient. All the pharmacist interventions were accepted by physicians, and among patients, the interventions were well accepted during the appointments, but compliance with the interventions was not measured. A statistically significant increase in CD4+ T-lymphocyte count in the intervention group was found (260.7 cells/mm(3) [95% CI =175.8-345.6] to 312.0 cells/mm(3) [95% CI =23.5-40.6], P=0.015), which was not observed in the control group. There was no statistical difference between the groups regarding HIV viral load. This study suggests that pharmacist interventions in patients with HIV infection can cause an increase in CD4+ T-lymphocyte counts and a decrease in DRPs, demonstrating the importance of an optimal pharmaceutical care plan.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On-line leak detection is a main concern for the safe operation of pipelines. Acoustic and mass balance are the most important and extensively applied technologies in field problems. The objective of this work is to compare these leak detection methods with respect to a given reference situation, i.e., the same pipeline and monitoring signals acquired at the inlet and outlet ends. Experimental tests were conducted in a 749 m long laboratory pipeline transporting water as the working fluid. The instrumentation included pressure transducers and electromagnetic flowmeters. Leaks were simulated by opening solenoid valves placed at known positions and previously calibrated to produce known average leak flow rates. Results have clearly shown the limitations and advantages of each method. It is also quite clear that acoustics and mass balance technologies are, in fact, complementary. In general, an acoustic leak detection system sends out an alarm more rapidly and locates the leak more precisely, provided that the rupture of the pipeline occurs abruptly enough. On the other hand, a mass balance leak detection method is capable of quantifying the leak flow rate very accurately and of detecting progressive leaks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A procedure is proposed for the determination of the residence time distribution (RTD) of curved tubes taking into account the non-ideal detection of the tracer. The procedure was applied to two holding tubes used for milk pasteurization in laboratory scale. Experimental data was obtained using an ionic tracer. The signal distortion caused by the detection system was considerable because of the short residence time. Four RTD models, namely axial dispersion, extended tanks in series, generalized convection and PER + CSTR association, were adjusted after convolution with the E-curve of the detection system. The generalized convection model provided the best fit because it could better represent the tail on the tracer concentration curve that is Caused by the laminar velocity profile and the recirculation regions. Adjusted model parameters were well cot-related with the now rate. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective was to study the flow pattern in a plate heat exchanger (PHE) through residence time distribution (RTD) experiments. The tested PHE had flat plates and it was part of a laboratory scale pasteurization unit. Series flow and parallel flow configurations were tested with a variable number of passes and channels per pass. Owing to the small scale of the equipment and the short residence times, it was necessary to take into account the influence of the tracer detection unit on the RID data. Four theoretical RID models were adjusted: combined, series combined, generalized convection and axial dispersion. The combined model provided the best fit and it was useful to quantify the active and dead space volumes of the PHE and their dependence on its configuration. Results suggest that the axial dispersion model would present good results for a larger number of passes because of the turbulence associated with the changes of pass. This type of study can be useful to compare the hydraulic performance of different plates or to provide data for the evaluation of heat-induced changes that occur in the processing of heat-sensitive products. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pool of five synthetic peptides was used as an antigenic base in an ELISA (ELISA-Pp) for laboratory diagnosis of Schistosoma mansoni. Serum samples were obtained from individuals with acute (n = 23) and chronic (n = 30) schistosomiasis, with other parasitoses (n = 39) or without parasitic infections (n = 100). ELISA-Pp was compared with other immunoenzymatic methods for detection of IgM (IgM-ELISA) or IgG (IgG-ELISA) as well as an immunofluorescence test for detection of IgM antibodies (IgM-IFT). The sensitivity and specificity of ELISA-Pp was 86.8% and 94.2% when tested on the schistosomiasis group and the non-schistosomiasis group, respectively. Comparison of ELISA-Pp with other serological methods resulted in K concordance indices varying from 0.59 to 0.75. Evaluation of anti-peptide IgG antibodies showed higher Levels in patients with acute compared with chronic schistosomiasis (P = 0.001). ELISA-Pp showed satisfactory sensitivity and high specificity and may constitute a potentially useful method for laboratory diagnosis of schistosomiasis mansoni. (c) 2007 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Restriction fragment length polymorphism (RFLP) is a common molecular assay used for genotyping, and it requires validated quality control procedures to prevent mistyping caused by impaired endonuclease activity. We have evaluated the usefulness of a plasmid-based internal control in RFLP assays. Results: Blood samples were collected from 102 individuals with acute myocardial infarction (AMI) and 108 non-AMI individuals (controls) for DNA extraction and laboratory analyses. The 1196C> T polymorphism in the toll-like receptor 4 (TLR4) gene was amplified by mismatched-polymerase chain reaction (PCR). Amplicons and pBluescript II SK-plasmid were simultaneously digested with endonuclease HincII. Fragments were separated on 2% agarose gels. Plasmid was completely digested using up to 55.2 nmL/L DNA solutions and 1 mu L PCR product. Nevertheless, plasmid DNA with 41.4 nM or higher concentrations was incompletely digested in the presence of 7 mL PCR product. In standardized conditions, TLR4 1196C> T variant was accurately genotyped. TLR4 1196T allele frequency was similar between AMI (3.1%) and controls (2.0%, p = 0.948). TLR4 SNP was not associated with AMI in this sample population. In conclusion, the plasmid-based control is a useful approach to prevent mistyping in RFLP assays, and it is validate for genetic association studies such as TLR4 1196C> T.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This communication describes an improved one-step solid-phase extraction method for the recovery of morphine (M), morphine-3-glucuronide (M3G), and morphine-6-glucuronide (M6G) from human plasma with reduced coextraction of endogenous plasma constituents, compared to that of the authors' previously reported method. The magnitude of the peak caused by endogenous plasma components in the chromatogram that eluted immediately before the retention time of M3G has been reduced (similar to 80%) significantly (p < 0.01) while achieving high extraction efficiencies for the compounds of interest, viz morphine, M6G, and M3G (93.8 +/- 2.5, 91.7 +/- 1.7, and 93.1 +/- 2.2%, respectively). Furthermore, when the improved solid-phase extraction method was used, the extraction cartridge-derived late-eluting peak (retention time 90 to 100 minutes) reported in our previous method, was no longer present in the plasma extracts. Therefore the combined effect of reducing the recovery of the endogenous components of plasma that chromatographed just before the retention time of M3G and the removal of the late-eluting, extraction cartridge-derived peak has resulted in a decrease in the chromatographic run-time to 20 minutes, thereby increasing the sample throughput by up to 100%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Immunolabeling is commonly used to localize antigens within frozen or paraffin tissue sections. We modified existing immunolabeling techniques to allow the detection of three antigens simultaneously within the one tissue section. The approach relies on the use of three monoclonal antibodies in sequential immunoperoxidase staining steps, each with colored substrates, resulting in the deposition of black, brown, and rose stains. The method is rapid and does not require novel techniques or materials. In this report, we demonstrate the colocalization of mast cell tryptase, neurofilament protein, and CD31 (platelet-endothelial cell adhesion molecule) or laminin in normal human skin and normal buccal mucosa, as an illustration of the power and simplicity of the multiple antigen localization technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Pneumothorax is a frequent complication during mechanical ventilation. Electrical impedance tomography (EIT) is a noninvasive tool that allows real-time imaging of regional ventilation. The purpose of this study was to 1) identify characteristic changes in the EIT signals associated with pneumothoraces; 2) develop and fine-tune an algorithm for their automatic detection; and 3) prospectively evaluate this algorithm for its sensitivity and specificity in detecting pneumothoraces in real time. Design: Prospective controlled laboratory animal investigation. Setting: Experimental Pulmonology Laboratory of the University of Sao Paulo. Subjects: Thirty-nine anesthetized mechanically ventilated supine pigs (31.0 +/- 3.2 kg, mean +/- SD). Interventions. In a first group of 18 animals monitored by EIT, we either injected progressive amounts of air (from 20 to 500 mL) through chest tubes or applied large positive end-expiratory pressure (PEEP) increments to simulate extreme lung overdistension. This first data set was used to calibrate an EIT-based pneumothorax detection algorithm. Subsequently, we evaluated the real-time performance of the detection algorithm in 21 additional animals (with normal or preinjured lungs), submitted to multiple ventilatory interventions or traumatic punctures of the lung. Measurements and Main Results: Primary EIT relative images were acquired online (50 images/sec) and processed according to a few imaging-analysis routines running automatically and in parallel. Pneumothoraces as small as 20 mL could be detected with a sensitivity of 100% and specificity 95% and could be easily distinguished from parenchymal overdistension induced by PEEP or recruiting maneuvers, Their location was correctly identified in all cases, with a total delay of only three respiratory cycles. Conclusions. We created an EIT-based algorithm capable of detecting early signs of pneumothoraces in high-risk situations, which also identifies its location. It requires that the pneumothorax occurs or enlarges at least minimally during the monitoring period. Such detection was operator-free and in quasi real-time, opening opportunities for improving patient safety during mechanical ventilation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study evaluated the efficiency of diagnostic laboratory methods to detect anti-Toxoplasma gondii antibodies in paired serum and aqueous humour samples from experimentally infected pigs. 18-mixed breed pigs were used during the experiment; these were divided into two groups, G I (infected group, n = 10) and G2 (uninfected group, n = 8). Infection was performed with 4 x 10(4) VEG strain oocysts at day 0 by the oral route in G1 animals. All pigs were euthanized at day 60, when retina, aqueous humour, and blood samples were collected. Anti-T gondii antibody levels were assessed in serum (s) and aqueous humour (ah) by indirect immunofluorescence assay (IFA), modified agglutination test (MAT), m-ELISA (using crude membranes from T gondii tachyzoites as antigen) and r-ELISA (using rhoptries from T gondii tachyzoites as antigen). Polymerase chain reactions (PCR) of samples from the retina were performed by using Tox4 and Tox5 primers. Antibody titers of G1 animals ranged from 128 to 1024 and from 16 to 256 in serum and aqueous humour, respectively. There were differences in the correlation coefficients between IFA(s) x IFA (ah) (r = 0.62, P = 0.05), MAT(s) x MAT (ah) (r = 0.97, P < 0.0001); however, there was no significant difference between r-ELISA(s) x r-ELISA (ah) (r = 0. 14, P = 0.7). Antibodies present in serum and aqueous humour recognized similar antigens. Samples of retina were positive by PCR in 30% (3/10) of infected pigs. G2 animals remained without antibody levels and were PCR negative throughout the experiment. These results suggest that the use of a combination of tests and immunoblotting for paired aqueous humour and serum samples could improve the sensitivity and specificity for the diagnosis of ocular toxoplasmosis. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Human polyomaviruses JC and BK may cause several clinical manifestations in immunocompromised hosts, including progressive multifocal leukoencephalopathy and hemorrhagic cystitis. Molecular detection by PCR is recognized as a sensitive and specific method for detecting human polyomaviruses in clinical samples. In this study, a real-time PCR assay using the LightCycler platform was evaluated and compared to an in-house PCR assay using a conventional detection method. A total of 122 urine specimens were tested, and human polyomavirus was detected in 49 specimens (40%) by both conventional PCR and LightCycler PCR. The remaining 73 specimens (60%) were found negative by both assays. For 46 of the 49 positive specimens, LightCycler PCR and conventional PCR identified the same polyomavirus type. These samples included 30 samples with JC virus (JCV), 14 samples with BK virus (BKV), and 2 samples in which both viruses were detected. In the remaining three samples, both JCV and BKV were detected by the conventional assay, but only JCV was detected by the LightCycler assay. The results of this study show that the LightCycler PCR assay displays sensitivity and specificity similar to those of a conventional PCR assay. These data, combined with its rapid turnaround time for results and decreased hands-on time, make the LightCycler PCR assay highly suitable for the rapid detection and differentiation of JCV and BKV in the clinical laboratory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Active surveillance for dengue (DEN) virus infected mosquitoes can be an effective way to predict the risk of dengue infection in a given area. However, doing so may pose logistical problems if mosquitoes must be kept alive or frozen fresh to detect DEN virus. In an attempt to simplify mosquito processing, we evaluated the usefulness of a sticky lure and a seminested reverse-transcriptase polymerase chain reaction assay (RT-PCR) for detecting DEN virus RNA under laboratory conditions using experimentally infected Aedes aegypti (L.) mosquitoes. In the first experiment, 40 male mosquitoes were inoculated with 0.13 mul of a 10(4) pfu/ml DEN-2 stock solution. After a 7-d incubation period, the mosquitoes were applied to the sticky lure and kept at room temperatures of 23-30 degreesC. Following 7,10,14, and 28 d application, 10 mosquitoes each were removed from the lure pooled and assayed for virus. DEN virus nucleic acid was clearly detectable in all pools up to 28 d after death. A second study evaluated sensitivity and specificity using one, two, and five DEN-infected mosquitoes removed after 7, 10, 14, 21 and 30 d application and tested by RT-PCR. All four DEN serotypes were individually inoculated in mosquitoes and evaluated using the same procedures as experiment 1. The four serotypes were detectable in as few as one mosquito 30 d after application to the lure with no evidence of cross-reactivity. The combination of sticky lures and RT-PCR show promise for mosquito and dengue virus surveillance and warrant further evaluation.