1000 resultados para hydride generation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several agricultural fields show high contents of arsenic because of irrigation with arsenic- contaminated groundwater. Vegetables accumulate arse- nic in their edible parts when grown in contaminated soils. Polluted vegetables are one of the main sources of arsenic in the food chain, especially for people living in rural arsenic endemic villages of India and Bangladesh. The aim of this study was to assess the feasibility of floriculture in the crop rotation system of arsenic en- demic areas of the Bengal Delta. The effects of different arsenic concentrations (0, 0.5, 1.0, and 2.0 mg As L−1) and types of flowering plant (Gomphrena globosa and Zinnia elegans) on plant growth and arsenic accumula- tion were studied under hydroponic conditions. Total arsenic was quantified using atomic absorption spec- trometer with hydride generation (HG-AAS). Arsenic was mainly accumulated in the roots (72 %), followed by leaves (12 %), stems (10 %), and flowers (<1 %). The flowering plants studied did not show as high phytoremediation capacities as other wild species, suchas ferns. However, they behaved as arsenic tolerant plants and grew and bloomed well, without showing any phytotoxic signs. This study proves that floriculture could be included within the crop rotation system in arsenic-contaminated agricultural soils, in order to im- prove food safety and also food security by increasing farmer’s revenue.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Improvements have been made on the currently available hydride generator system manufactured by SpectraMetrics Incorporated, because the system was found to be unsatisfactory with respect to the following: 1. the drying agent, anhydrous calcium chloride, 2. the special sample tube, 3. the direction of argon flow through the Buchner funnel when it came to dealing with real sample, that is, with reference only to aqueous extracts of soil samples. Changes that were made on the system included the replacement of anhydrous calcium chloride with anhydrous calcium sulphate and the replacement of the special sample tube with a modified one made from silica. Re-directing the flow of argon through the top of the Buchner funnel appeared to make the system compatible with aqueous extracts of soil samples. The interferences from 1000 ~g/mL of nickel(II) , cobalt(II), iron(III), copper(II) have been eliminated with the aid of 1.4 M hydrochloric acid and 1% (weight/volume) L-cystine. Greater than 90% recovery of 0.3 ~g/mL arsenic signal was achieved in each case. Furthermore, 103% of arsenic signal was accomplished in the presence of 1000 ~g/mL cadmium with 5 M Hel. tVhen each of the interferents was present in solution at 1000 ppm, a recovery of 85% was achieved by using 5 M hydrochloric acid and 3% (weight/volume) L-cystine. Without L-cystine and when 1.4 M hydrochloric acid was used, the recoveries were 0% (Ni), 0% (Co), 88% (Fe), 15% (Cu), 18% (Cd). Similarly, a solution containing 1000 ppm of each interferent gave a zero percent recovery of arsenic. The reduction of trivalent and pentavalent arsenic at a pH less than one has also been investigated and shown to be quantitative if peak areas are measured. The reproducibility determination of a 0.3 Vg/mL standard arsenic solution by hydride generation shows a relative standard deviation of 3.4%. The detection limits with and without Porapak Q have been found to be 0.6 ng/mL and 1.0 ng/mL, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work describes the evaluation of several parameters for the preparation of a tuna fish candidate as a reference material (RM) in order to measure the total As mass fraction by slurry sampling graphite furnace atomic absorption spectrometry (SLS-GF AAS) and slurry sampling hydride generation atomic absorption spectrometry (SLS-HG AAS). The main parameters investigated were the homogeneity, analyte segregation and composition during material production. For candidate RM preparation, tuna fish was collected at a local market, cleaned, freeze-dried and treated using different procedures as follows: (1) ground in a cutting mill and separated in different particle sizes (2) ground in cryogenic mill. The mass fraction of As in the cryogenically ground sample was (4.77 +/- A 0.19) mu g g(-1) for SLS-GF AAS and (4.61 +/- A 0.34) mu g g(-1) for SLS-HG AAS. The accuracy of the procedures was checked with tuna fish certified reference material (BCR 627) with recoveries of 102 and 94% for SLS-GF AAS and SLS-HG AAS, respectively. The homogeneity factor was calculated for different pretreatment procedures and for particle sizes in the range of 500-150 mu g, indicating good homogeneity, except for raw fish. There was no observed analyte segregation and no losses, no contamination and no changes in the microdistribution of material during preparation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We have developed an eletroanalytical method that employs Cu2+ solutions to determine arsenic in sugarcane brandy using an electrode consisting of carbon paste modified with carbon nanotubes (CNTPE) and polymeric resins. We used linear sweep (LSV) and differential-pulse (DPV) voltammetry with cathodic stripping for CNTPE containing mineral oil or silicone as binder. The analytical curves were linear from 30 to 110 μg L−1 and from 10 to 110 μg L−1 for LSV and DPV, respectively. The limits of detection (L.O.D.) and quantification (L.O.Q.) of CNTPE were 10.3 and 34.5 μg L−1 for mineral oil and 3.4 and 11.2 μg L−1 for silicone. We applied this method to determine arsenic in five commercial sugarcane brandy samples. The results agreed well with those obtained by hydride generation combined with atomic absorption spectrometry (HG AAS).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A presença de elementos não essenciais nas águas superficiais do rio Amazonas é uma preocupação global, o objetivo da pesquisa foi estudar a distribuição dos elementos As, Al, Mn, e Pb na água do estuário do rio Amazonas. As amostras foram coletadas em três regiões distintas: Canal Norte (AP), Canal Sul (PA) e rio Pará (PA) em três profundidades, com um total de 84 amostras. A espectrometria de emissão atômica com plasma indutivamente acoplado (ICPAES) foi utilizada para avaliar os teores de Al, Mn e Pb e a espectrofotometria de absorção atômica com geração de hidretos (HGAAS) foi usada para a análise do As. O As variou de <0,35 a 50,60 µg/L, o Al de <1,88 a 3347,70 µg/L, o Mn de 0,13 a 403,39 µg/L e Pb de <0,18 a 57,78 µg/L. Em média As (canal Sul), Al (todas as regiões), Mn (canal Norte e Sul) e Pb (canal Norte e Sul) se encontraram em valores acima do permitido pela legislação brasileira. Os elementos podem ter origem antrópica originária de atividade de mineração e industrial e origem natural proveniente de decomposição de rochas ígneas da bacia de drenagem do rio Amazonas que disponibilizam o elemento na forma ligada ao material particulado em suspensão.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

No presente trabalho descreve-se o método para determinação de arsênio, antimônio e bismuto em materiais geológicos, utilizando a geração de hidretos acoplado ao ICP-OES, que proporciona a determinação, com exatidão, dos elementos de interesse em concentrações abaixo de 1 ppm. O método é sensível e, por isso, está sujeito a interferências, como as causadas por elementos presentes na matriz. Desenvolveu-se uma técnica de dissolução eficiente e foram realizados diversos tratamentos com dopagens de soluções-padrão e testes com o uso de tiouréia e iodeto de potássio com ácido ascórbico em diferentes concentrações, com o objetivo de minimizar possíveis interferências presentes na matriz. Os resultados finais, mediante a dissolução de material geológico de referência internacional na determinação de arsênio, bismuto e antimônio, mostraram recuperações superiores à 97% em amostras com concentrações abaixo de 1 ppm.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the bioaccumulation of tributyltin (TBT) by the blue crab (Callinectes sapidus). Animals were fed with contaminated food containing 30 µg g-1 of TBT expressed as Sn. The analytes were determined in the gills, hepatopancreas and muscle. Acid digestion was used in the total Sn determination, and a solid-phase extraction technique was used for the selective determination of TBT. Limits of detection of 44.6 and 4.46 ng g-1 were found for HG-ICP OES (hydride generation-inductively coupled plasma optical emission spectroscopy) and ICP-MS (ICP-mass spectrometry), respectively. The results for non-contaminated animals were below 50 ng g-1, while the animals subjected to the contaminated food showed higher tissue concentrations of Sn (until 6229 ng g-1) and TBT (until 3357 ng g-1) related to the number of exposure days. According to the results, Sn is bioaccumulated by the blue crab in higher concentrations in the hepatopancreas. For most of these animals, the results suggest that Sn is bioaccumulated as TBT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Large amounts of reactive oxygen species are produced in hemodialysis (HD) patients, and, at higher concentrations, reactive oxygen species are thought to be involved in the pathogenesis of cardiovascular disease. It has been proposed that selenium (Se) may exert an antiatherogenic influence by reducing oxidative stress. The richest known food source of Se is the Brazil nut (Bertholletia excelsa, family Lecythidaceae), found in the Amazon region. Objective: The objective of this work was to determine if Se plasma levels in HD patients submitted to a program of supplementation during 3 months with 1 Brazil nut by day could be sustained after 12 months. Methods: A total of 21 HD patients (54.2 +/- 15.2 years old; average time on dialysis, 82.3 +/- 51.6 months; body mass index, 24.4 +/- 3.8 kg/m(2)) from the RenalCor Clinic in Rio de Janeiro, Brazil, were followed up 12 months after the supplementation study ended. The Se plasma levels were determined by atomic absorption spectrophotometry with hydride generation. Results: The Se Plasma levels (17.3 +/- 19.9 mg/L) were below the normal range (60 to 120 mu g/L) before nut supplementation, and after 3 months of supplementation, the levels increased to 106.8 +/- 50.3 mu g/L (P < .0001). Twelve months after supplementation, the plasma Se levels decreased to 31.9 +/- 14.8 mu g/L (P < .0001). Conclusions: The data showed that these patients were Se deficient and that the consumption of Brazil nut was effective to increase the Se parameters of nutritional status. Se levels 12 months after the supplementation period were not as low as presupplementation levels but yet significantly lower, and we needed to motivate patients to adopt different dietary intake patterns. (C) 2012 by the National Kidney Foundation, Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background/Aims: Oxidative stress plays a central role in Alzheimer's disease (AD). Pro198Leu cytosolic glutathione peroxidase (GPx1) polymorphism seems to be associated with a lower activity of this enzyme, but there are no studies with AD patients. Thus, the aim was to determine the frequency of the GPx1 Pro198Leu polymorphism in AD patients and to verify its relation to glutathione peroxidase (GPx) activity and selenium (Se) status. Methods:The study was carried out in a group of AD elderly (n = 28) compared to a control group (n = 29). Blood Se concentrations were measured through hydride generation atomic absorption spectroscopy. GPx activity was determined using a commercial kit, and the polymorphism using amplified DNA sequencing. Results:The distribution of genotypes was not different between groups. The variant allele frequency was 0.179 (AD group) and 0.207 (control group). Although no differences regarding GPx activity were found between individuals with different genotypes, lower blood Se levels were found in Pro/Pro AD patients compared to Pro/Pro control subjects, which was not found in the Pro/Leu groups. Moreover, the association between the erythrocyte Se concentration and GPx activity was affected by the Pro198Leu genotype. Conclusions: Results indicate that this polymorphism had apparently affected Se status in AD patients and that more studies in this field are necessary. Copyright (c) 2012 S. Karger AG, Basel

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new technique for the precise and accurate determination of Ge stable isotope compositions has been developed and applied to silicate rocks and biogenic opal. The analyses were performed using a continuous flow hydride generation system coupled to a MC-ICP-MS. Samples have been purified through anion- and cation-exchange resins to separate Ge from matrix elements and eliminate potential isobaric interferences. Variations of 74Ge/70Ge ratios are expressed as d74Ge values relative to our internal standard and the long-term external reproducibility of the data is better than 0.2? for sample size as low as 15 ng of Ge. Data are presented for igneous and sedimentary rocks, and the overall variation is 2.4? in d74Ge, representing 12 times the uncertainty of the measurements and demonstrating that the terrestrial isotopic composition of Ge is not unique. Co-variations of 74Ge/70Ge, 73Ge/70Ge and 72Ge/70Ge ratios follow a mass-dependent behaviour and imply natural isotopic fractionation of Ge by physicochemical processes. The range of d74Ge in igneous rocks is only 0.25? without systematic differences among continental crust, oceanic crust or mantle material. On this basis, a Bulk Silicate Earth reservoir with a d74Ge of 1.3+/-0.2? can be defined. In contrast, modern biogenic opal such as marine sponges and authigenic glauconite displayed higher d74Ge values between 2.0? and 3.0?. This suggests that biogenic opal may be significantly enriched in light isotopes with respect to seawater and places a lower bound on the d74Ge of the seawater to +3.0?.This suggests that seawater is isotopically heavy relative to Bulk Silicate Earth and that biogenic opal may be significantly fractionated with respect to seawater. Deep-sea sediments are within the range of the Bulk Silicate Earth while Mesozoic deep-sea cherts (opal and quartz) have d74Ge values ranging from 0.7? to 2.0?. The variable values of the cherts cannot be explained by binary mixing between a biogenic component and a detrital component and are suggestive of enrichment in the light isotope of diagenetic quartz. Further work is now required to determine Ge isotope fractionation by siliceous organisms and to investigate the effect of diagenetic processes during chert lithification.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Multiple-collector inductively coupled plasma mass spectrometry has been used for the precise measurement of the isotopic composition of Se in geological samples. Se is chemically purified before analysis by using cotton impregnated with thioglycollic acid. This preconcentration step is required for the removal of matrix-interfering elements for hydride generation, such as transitional metals, and also for the quantitative separation of other hydride-forming elements, such as Ge, Sb, and As. The analyte is introduced in the plasma torch with a continuous-flow hydride generation system. Instrumental mass fractionation is corrected with a "standard-sample bracketing" approach. By use of this new technique, the minimum Se required per analysis is lowered to 10 ng, which is one order of magnitude less than the amount needed for the N-TIMS technique. The estimated external precision calculated for the 82Se/76Se isotope ratio is 0.25? (2 sigma), and the data are reported as delta notation (?) relative to our internal standard (MERCK elemental standard solution). Measurements of Se isotopes are presented for samples of standard solutions and geological reference materials, such as silicate rocks, soils, and sediments. The Se isotopic composition of selected terrestrial and extraterrestrial materials are also presented. An overall Se isotope variation of 8? has been observed, suggesting that Se isotopes fractionate readily and are extremely useful tracers of natural processes.