897 resultados para fault recovery


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper. © 2010 IOP Publishing Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A superconducting fault current limiter (SCFL) consisted of a transformer with low reactance connected to the power line and with the secondary winding short-circuited by a modular superconducting limiter device with 16 elements connected in series was constructed and tested. The designed coupling transformer has low dispersion reactance in order to limit the voltage drop in the power line within the range of 5 % to 10 %. The experimental results showed that an insertion of a 0.125 Omega resistance limited the peak current to a factor of 2.5 times of the unlimited current. The power dissipation reached 39 kW during 100 ms, with an energy density of 380 J/cm(3). Based on these results, the SCFL will be further tested in a 3 MVA (15 kV/380 V) generator for currents up to 10 kA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The resistive-type superconducting fault current limiters (RSFCL) prototypes using YBCO-coated conductors have shown current limitation for medium voltage class applications for acting time up to 80 ms. By connecting an air-core reactor in parallel with the RSFCL, thus making an hybrid current limiter, one can extend the acting time for up to 1 s. In this work, we report the performance of a hybrid current limiter subjected to an AC peak fault current of 2 kA during 1 s for which within the first 80 ms the SFCL limits the current concurrently with the air-core reactor, and for the remaining 920 ms, only the air-core reactor limits the current. In order to evaluate the actual conditions for subsequent reconnection of RSFCL to the power grid, the hybrid fault current limiter was tested varying the time interval for recovery from 900 ms and 1.2 s, followed again by the concurrent operation of the hybrid limiter during 1 s (SFCL during 80 ms). From this evaluation test, the recovery time can be measured and compared using the voltage peak generated in superconducting module from the first and second fault test. The recovery time was also determined through the pulsed current method (PCM) on short-length sample test. The results showed that the fault current was limited from 1.9 kA down to 514 A after 1 cycle of 60 Hz frequency, with recovery time lower than 1.2 s for two subsequent fault current tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Requirements for systems to continue to operate satisfactorily in the presence of faults has led to the development of techniques for the construction of fault tolerant software. This thesis addresses the problem of error detection and recovery in distributed systems which consist of a set of communicating sequential processes. A method is presented for the `a priori' design of conversations for this class of distributed system. Petri nets are used to represent the state and to solve state reachability problems for concurrent systems. The dynamic behaviour of the system can be characterised by a state-change table derived from the state reachability tree. Systematic conversation generation is possible by defining a closed boundary on any branch of the state-change table. By relating the state-change table to process attributes it ensures all necessary processes are included in the conversation. The method also ensures properly nested conversations. An implementation of the conversation scheme using the concurrent language occam is proposed. The structure of the conversation is defined using the special features of occam. The proposed implementation gives a structure which is independent of the application and is independent of the number of processes involved. Finally, the integrity of inter-process communications is investigated. The basic communication primitives used in message passing systems are seen to have deficiencies when applied to systems with safety implications. Using a Petri net model a boundary for a time-out mechanism is proposed which will increase the integrity of a system which involves inter-process communications.

Relevância:

20.00% 20.00%

Publicador: