103 resultados para extubation


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Optimal management of mechanical ventilation and weaning requires dynamic and collaborative decision making to minimize complications and avoid delays in the transition to extubation. In the absence of collaboration, ventilation decision making may be fragmented, inconsistent, and delayed. Our objective was to describe the professional group with responsibility for key ventilation and weaning decisions and to examine organizational characteristics associated with nurse involvement.

Methods: A multi-center, cross-sectional, self-administered survey was sent to nurse managers of adult intensive care units (ICUs) in Denmark, Germany, Greece, Italy, Norway, Switzerland, Netherlands and United Kingdom (UK). We summarized data as proportions (95% confidence intervals (CIs)) and calculated odds ratios (OR) to examine ICU organizational variables associated with collaborative decision making.

Results: Response rates ranged from 39% (UK) to 92% (Switzerland), providing surveys from 586 ICUs. Interprofessional collaboration (nurses and physicians) was the most common approach to initial selection of ventilator settings (63% (95% CI 59 to 66)), determination of extubation readiness (71% (67 to 75)), weaning method (73% (69 to 76)), recognition of weaning failure (84% (81 to 87)) and weaning readiness (85% (82 to 87)), and titration of ventilator settings (88% (86 to 91)). A nurse-to-patient ratio other than 1:1 was associated with decreased interprofessional collaboration during titration of ventilator settings (OR 0.2, 95% CI 0.1 to 0.6), weaning method (0.4 (0.2 to 0.9)), determination of extubation readiness (0.5 (0.2 to 0.9)) and weaning failure (0.4 (0.1 to 1.0)). Use of a weaning protocol was associated with increased collaborative decision making for determining weaning (1.8 (1.0 to 3.3)) and extubation readiness (1.9 (1.2 to 3.0)), and weaning method (1.8 (1.1 to 3.0)). Country of ICU location influenced the profile of responsibility for all decisions. Automated weaning modes were used in 55% of ICUs.

Conclusions: Collaborative decision making for ventilation and weaning was employed in most ICUs in all countries although this was influenced by nurse-to-patient ratio, presence of a protocol, and varied across countries. Potential clinical implications of a lack of collaboration include delayed adaptation of ventilation to changing physiological parameters, and delayed recognition of weaning and extubation readiness resulting in unnecessary prolongation of ventilation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To test whether simvastatin improves physiological and biological outcomes in patients undergoing esophagectomy.

BACKGROUND: One-lung ventilation during esophagectomy is associated with inflammation, alveolar epithelial and systemic endothelial injury, and the development of acute lung injury (ALI). Statins that modify many of the underlying processes are a potential therapy to prevent ALI.

METHODS: We conducted a randomized double-blind placebo-controlled trial in patients undergoing esophagectomy. Patients received simvastatin 80 mg or placebo enterally for 4 days preoperatively and 7 days postoperatively. The primary end point was pulmonary dead space (Vd/Vt) at 6 hours after esophagectomy or before extubation. Inflammation was assessed by plasma cytokines and intraoperative exhaled breath condensate pH; alveolar type 1 epithelial injury was assessed by plasma receptor for advanced glycation end products and systemic endothelial injury by the urine albumin-creatinine ratio.

RESULTS: Thirty-nine patients were randomized; 8 patients did not undergo surgery and were excluded. Fifteen patients received simvastatin and 16 received placebo. There was no difference in Vd/Vt or other physiological outcomes. Simvastatin resulted in a significant decrease in plasma MCP-1 on day 3 and reduced exhaled breath condensate acidification. Plasma receptor for advanced glycation end products was significantly lower in the simvastatin-treated group, as was the urine albumin-creatinine ratio on day 7 postsurgery. ALI developed in 4 patients in the placebo group and no patients in the simvastatin group although this difference was not statistically significant (P = 0.1).

CONCLUSIONS: In this proof of concept study, pretreatment with simvastatin in esophagectomy decreased biomarkers of inflammation as well as pulmonary epithelial and systemic endothelial injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IntroductionAutomated weaning systems may improve adaptation of mechanical support for a patient’s ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. Our objective was to compare mechanical ventilator weaning duration for critically ill adults and children when managed with automated systems versus non-automated strategies. Secondary objectives were to determine differences in duration of ventilation, intensive care unit (ICU) and hospital length of stay (LOS), mortality, and adverse events.MethodsElectronic databases were searched to 30 September 2013 without language restrictions. We also searched conference proceedings; trial registration websites; and article reference lists. Two authors independently extracted data and assessed risk of bias. We combined data using random-effects modelling.ResultsWe identified 21 eligible trials totalling 1,676 participants. Pooled data from 16 trials indicated that automated systems reduced the geometric mean weaning duration by 30% (95% confidence interval (CI) 13% to 45%), with substantial heterogeneity (I2 = 87%, P <0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not with surgical populations or using other systems. Automated systems reduced ventilation duration with no heterogeneity (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of effect on mortality, hospital LOS, reintubation, self-extubation and non-invasive ventilation following extubation. Automated systems reduced prolonged mechanical ventilation and tracheostomy. Overall quality of evidence was high.ConclusionsAutomated systems may reduce weaning and ventilation duration and ICU stay. Due to substantial trial heterogeneity an adequately powered, high quality, multi-centre randomized controlled trial is needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Automated closed loop systems may improve adaptation of mechanical support for a patient's ventilatory needs and facilitate systematic and early recognition of their ability to breathe spontaneously and the potential for discontinuation of ventilation. This review was originally published in 2013 with an update published in 2014. Objectives The primary objective for this review was to compare the total duration of weaning from mechanical ventilation, defined as the time from study randomization to successful extubation (as defined by study authors), for critically ill ventilated patients managed with an automated weaning system versus no automated weaning system (usual care). Secondary objectives for this review were to determine differences in the duration of ventilation, intensive care unit (ICU) and hospital lengths of stay (LOS), mortality, and adverse events related to early or delayed extubation with the use of automated weaning systems compared to weaning in the absence of an automated weaning system. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 8); MEDLINE (OvidSP) (1948 to September 2013); EMBASE (OvidSP) (1980 to September 2013); CINAHL (EBSCOhost) (1982 to September 2013); and the Latin American and Caribbean Health Sciences Literature (LILACS). Relevant published reviews were sought using the Database of Abstracts of Reviews of Effects (DARE) and the Health Technology Assessment Database (HTA Database). We also searched the Web of Science Proceedings; conference proceedings; trial registration websites; and reference lists of relevant articles. The original search was run in August 2011, with database auto-alerts up to August 2012. Selection criteria We included randomized controlled trials comparing automated closed loop ventilator applications to non-automated weaning strategies including non-protocolized usual care and protocolized weaning in patients over four weeks of age receiving invasive mechanical ventilation in an ICU. Data collection and analysis Two authors independently extracted study data and assessed risk of bias. We combined data in forest plots using random-effects modelling. Subgroup and sensitivity analyses were conducted according to a priori criteria. Main results We included 21 trials (19 adult, two paediatric) totaling 1676 participants (1628 adults, 48 children) in this updated review. Pooled data from 16 eligible trials reporting weaning duration indicated that automated closed loop systems reduced the geometric mean duration of weaning by 30% (95% confidence interval (CI) 13% to 45%), however heterogeneity was substantial (I2 = 87%, P < 0.00001). Reduced weaning duration was found with mixed or medical ICU populations (42%, 95% CI 10% to 63%) and Smartcare/PS™ (28%, 95% CI 7% to 49%) but not in surgical populations or using other systems. Automated closed loop systems reduced the duration of ventilation (10%, 95% CI 3% to 16%) and ICU LOS (8%, 95% CI 0% to 15%). There was no strong evidence of an effect on mortality rates, hospital LOS, reintubation rates, self-extubation and use of non-invasive ventilation following extubation. Prolonged mechanical ventilation > 21 days and tracheostomy were reduced in favour of automated systems (relative risk (RR) 0.51, 95% CI 0.27 to 0.95 and RR 0.67, 95% CI 0.50 to 0.90 respectively). Overall the quality of the evidence was high with the majority of trials rated as low risk. Authors' conclusions Automated closed loop systems may result in reduced duration of weaning, ventilation and ICU stay. Reductions are more likely to occur in mixed or medical ICU populations. Due to the lack of, or limited, evidence on automated systems other than Smartcare/PS™ and Adaptive Support Ventilation no conclusions can be drawn regarding their influence on these outcomes. Due to substantial heterogeneity in trials there is a need for an adequately powered, high quality, multi-centre randomized controlled trial in adults that excludes 'simple to wean' patients. There is a pressing need for further technological development and research in the paediatric population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Small adenomas may be missed during colonoscopy, but chromoscopy has been reported to enhance detection. The aim of this randomized-controlled trial was to determine the effect of total colonic dye spray on adenoma detection during routine colonoscopy.

Methods: Consecutive outpatients undergoing routine colonoscopy were randomized to a dye-spray group (0.1% indigo carmine used to coat the entire colon during withdrawal from the cecum) or control group (no dye).

Results: Two hundred fifty-nine patients were randomized, 124 to the dye-spray and 135 to the control group; demographics, indication for colonoscopy, and quality of the preparation were similar between the groups. Extubation from the cecum took a median of 9:05 minutes (range: 2:4824:44 min) in the dye-spray group versus 4:52 minutes (range: 1:42-15:21 min] in the control group (p <0.0001). The proportion of patients with at least 1 adenoma and the total number of adenomas were not different between groups. However, in the dye-spray group significantly more diminutive adenomas (

Conclusions: Dye-spray increases the detection of small adenomas in the proximal colon and patients with multiple adenomas, but long-term outcomes should be studied to determine the clinical value of these findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Care of critically ill patients in intensive care units (ICUs) often requires potentially invasive or uncomfortable procedures, such as mechanical ventilation (MV). Sedation can alleviate pain and discomfort, provide protection from stressful or harmful events, prevent anxiety and promote sleep. Various sedative agents are available for use in ICUs. In the UK, the most commonly used sedatives are propofol (Diprivan(®), AstraZeneca), benzodiazepines [e.g. midazolam (Hypnovel(®), Roche) and lorazepam (Ativan(®), Pfizer)] and alpha-2 adrenergic receptor agonists [e.g. dexmedetomidine (Dexdor(®), Orion Corporation) and clonidine (Catapres(®), Boehringer Ingelheim)]. Sedative agents vary in onset/duration of effects and in their side effects. The pattern of sedation of alpha-2 agonists is quite different from that of other sedatives in that patients can be aroused readily and their cognitive performance on psychometric tests is usually preserved. Moreover, respiratory depression is less frequent after alpha-2 agonists than after other sedative agents.

OBJECTIVES: To conduct a systematic review to evaluate the comparative effects of alpha-2 agonists (dexmedetomidine and clonidine) and propofol or benzodiazepines (midazolam and lorazepam) in mechanically ventilated adults admitted to ICUs.

DATA SOURCES: We searched major electronic databases (e.g. MEDLINE without revisions, MEDLINE In-Process & Other Non-Indexed Citations, EMBASE and Cochrane Central Register of Controlled Trials) from 1999 to 2014.

METHODS: Evidence was considered from randomised controlled trials (RCTs) comparing dexmedetomidine with clonidine or dexmedetomidine or clonidine with propofol or benzodiazepines such as midazolam, lorazepam and diazepam (Diazemuls(®), Actavis UK Limited). Primary outcomes included mortality, duration of MV, length of ICU stay and adverse events. One reviewer extracted data and assessed the risk of bias of included trials. A second reviewer cross-checked all the data extracted. Random-effects meta-analyses were used for data synthesis.

RESULTS: Eighteen RCTs (2489 adult patients) were included. One trial at unclear risk of bias compared dexmedetomidine with clonidine and found that target sedation was achieved in a higher number of patients treated with dexmedetomidine with lesser need for additional sedation. The remaining 17 trials compared dexmedetomidine with propofol or benzodiazepines (midazolam or lorazepam). Trials varied considerably with regard to clinical population, type of comparators, dose of sedative agents, outcome measures and length of follow-up. Overall, risk of bias was generally high or unclear. In particular, few trials blinded outcome assessors. Compared with propofol or benzodiazepines (midazolam or lorazepam), dexmedetomidine had no significant effects on mortality [risk ratio (RR) 1.03, 95% confidence interval (CI) 0.85 to 1.24, I (2) = 0%; p = 0.78]. Length of ICU stay (mean difference -1.26 days, 95% CI -1.96 to -0.55 days, I (2) = 31%; p = 0.0004) and time to extubation (mean difference -1.85 days, 95% CI -2.61 to -1.09 days, I (2) = 0%; p < 0.00001) were significantly shorter among patients who received dexmedetomidine. No difference in time to target sedation range was observed between sedative interventions (I (2) = 0%; p = 0.14). Dexmedetomidine was associated with a higher risk of bradycardia (RR 1.88, 95% CI 1.28 to 2.77, I (2) = 46%; p = 0.001).

LIMITATIONS: Trials varied considerably with regard to participants, type of comparators, dose of sedative agents, outcome measures and length of follow-up. Overall, risk of bias was generally high or unclear. In particular, few trials blinded assessors.

CONCLUSIONS: Evidence on the use of clonidine in ICUs is very limited. Dexmedetomidine may be effective in reducing ICU length of stay and time to extubation in critically ill ICU patients. Risk of bradycardia but not of overall mortality is higher among patients treated with dexmedetomidine. Well-designed RCTs are needed to assess the use of clonidine in ICUs and identify subgroups of patients that are more likely to benefit from the use of dexmedetomidine.

STUDY REGISTRATION: This study is registered as PROSPERO CRD42014014101.

FUNDING: The National Institute for Health Research Health Technology Assessment programme. The Health Services Research Unit is core funded by the Chief Scientist Office of the Scottish Government Health and Social Care Directorates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

1.Pre-assessment data of the patient A 2-year-old boy, weighing 15 kg was admitted with a history of limited mouth opening(inter-incisor distance of 6 mm), hypoplastic and retrognathic mandible (bird face deformity) and facial asymmetry from left temporomandibular joint ankylosis (TMJA). He was born at term, after an uneventful pregnancy, and there was no report of trauma during caesarean section. No other possible aetiologies were identified. He was scheduled for mandibular osteotomy. Preoperative ENT examination revealed adenotonsillar hypertrophy. 2. Anaesthetic Plan A fiberoptic nasal intubation was performed under deep inhalation anaesthesia with sevoflurane, with the patient breathing spontaneously. Midazolam (0.05 mg.kg-1) and alfentanil (0.03 mg.kg-1) were given and anaesthesia was maintained with O2/air and sevoflurane. No neuromuscular blocking agent was administered since the surgical team needed facial nerve monitoring. 3. Description of incident During surgery an accidental extubation occurred and an attempt was made to reintubate the trachea by direct laryngoscopy. Although the osteotomy was nearly completed, the vocal cords could not be visualized (Cormack-Lehane grade IV laryngoscopic view). 4. Solving the problem Re-intubation was finally accomplished with the flexible fiberscope and the procedure was concluded without any more incidents. Extubation was performed 24 hours postoperatively with the patient fully awake. After surgery mouth opening improved to inter-incisor gap of 15 mm. 5. Lessons learned and take home message Two airways issues present in this case can lead to difficultventilation and intubation: TMJA and adenotonsillar hypertrophy. These difficulties were anticipated and managed accordingly. The accidental extubation brought to our attention the fact that, even after surgical correction, this airway remains challenging. Even with intensive jaw stretchingexercises there is a high incidence of re-ankylosis, especially in younger patients. One should bear that in mind when anaesthetizing patients with TMJA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Postoperative delirium after cardiac surgery is associated with increased morbidity and mortality as well as prolonged stay in both the intensive care unit and the hospital. The authors sought to identify modifiable risk factors associated with the development of postoperative delirium in elderly patients after elective cardiac surgery in order to be able to design follow-up studies aimed at the prevention of delirium by optimizing perioperative management. A post hoc analysis of data from patients enrolled in a randomized controlled trial was performed. A single university hospital. One hundred thirteen patients aged 65 or older undergoing elective cardiac surgery with cardiopulmonary bypass. None. MEASUREMENTS AND MAINS RESULTS: Screening for delirium was performed using the Confusion Assessment Method (CAM) on the first 6 postoperative days. A multivariable logistic regression model was developed to identify significant risk factors and to control for confounders. Delirium developed in 35 of 113 patients (30%). The multivariable model showed the maximum value of C-reactive protein measured postoperatively, the dose of fentanyl per kilogram of body weight administered intraoperatively, and the duration of mechanical ventilation to be independently associated with delirium. In this post hoc analysis, larger doses of fentanyl administered intraoperatively and longer duration of mechanical ventilation were associated with postoperative delirium in the elderly after cardiac surgery. Prospective randomized trials should be performed to test the hypotheses that a reduced dose of fentanyl administered intraoperatively, the use of a different opioid, or weaning protocols aimed at early extubation prevent delirium in these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En salle d’opération, les tâches de l’anesthésiste sont nombreuses. Alors que l’utilisation de nouveaux outils technologiques l’informe plus fidèlement sur ce qui se passe pour son patient, ces outils font que ses tâches deviennent plus exigeantes. En vue de diminuer cette charge de travail, nous avons considérer l’administration automatique d’agents anesthésiques en se servant de contrôle en boucle fermée. À cette fin, nous avons développé un système d’administration d’un agent anesthésique (le propofol) visant à maintenir à un niveau optimal la perte de conscience du patient pendant toute la durée d’une chirurgie. Le système comprend un ordinateur, un moniteur d’anesthésie et une pompe de perfusion. L’ordinateur est doté d’un algorithme de contrôle qui, à partir d’un indice (Bispectral IndexTM ou BIS) fournit par le moniteur d’anesthésie détermine le taux d’infusion de l’agent anesthésiant. Au départ, l’anesthésiste choisit une valeur cible pour la variable de contrôle BIS et l’algorithme, basé sur système expert, calcule les doses de perfusion de propofol de sorte que la valeur mesurée de BIS se rapproche le plus possible de la valeur cible établie. Comme interface-utilisateur pour un nouveau moniteur d’anesthésie, quatre sortes d’affichage ont été considérés: purement numérique, purement graphique, un mélange entre graphique et numérique et un affichage graphique intégré (soit bidimensionnel). À partir de 20 scenarios différents où des paramètres normaux et anormaux en anesthésie étaient présentés à des anesthésistes et des résidents, l’étude des temps de réaction, de l’exactitude des réponses et de la convivialité (évaluée par le NASA-TLX) a montré qu’un affichage qui combine des éléments graphiques et numériques était le meilleur choix comme interface du système. Une étude clinique a été réalisée pour comparer le comportement du système d’administration de propofol en boucle fermée comparativement à une anesthésie contrôlée de façon manuelle et conventionnelle où le BIS était aussi utilisé. Suite à l’approbation du comité d’éthique et le consentement de personnes ayant à subir des chirurgies générales et orthopédiques, 40 patients ont été distribués également et aléatoirement soit dans le Groupe contrôle, soit dans le Groupe boucle fermée. Après l’induction manuelle de propofol (1.5 mg/kg), le contrôle en boucle fermée a été déclenché pour maintenir l’anesthésie à une cible de BIS fixée à 45. Dans l’autre groupe, le propofol a été administré à l’aide d’une pompe de perfusion et l’anesthésiste avait aussi à garder manuellement l’indice BIS le plus proche possible de 45. En fonction du BIS mesuré, la performance du contrôle exercé a été définie comme excellente pendant les moments où la valeur du BIS mesurée se situait à ±10% de la valeur cible, bonne si comprise de ±10% à ±20%, faible si comprise de ±20% à ±30% ou inadéquate lorsque >±30%. Dans le Groupe boucle fermée, le système a montré un contrôle excellent durant 55% du temps total de l’intervention, un bon contrôle durant 29% du temps et faible que pendant 9% du temps. Le temps depuis l’arrêt de la perfusion jusqu’à l’extubation est de 9 ± 3.7 min. Dans le Groupe contrôle, un contrôle excellent, bon, et faible a été enregistré durant 33%, 33% et 15% du temps respectivement et les doses ont été changées manuellement par l’anesthésiste en moyenne 9.5±4 fois par h. L’extubation a été accomplie après 11.9 ± 3.3 min de l’arrêt de la perfusion. Dans le Groupe boucle fermée, un contrôle excellent a été obtenu plus longtemps au cours des interventions (P<0.0001) et un contrôle inadéquat moins longtemps (P=0.001) que dans le Groupe contrôle. Le système en boucle fermée d’administration de propofol permet donc de maintenir plus facilement l’anesthésie au voisinage d’une cible choisie que l’administration manuelle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La ventilation unipulmonaire (SLV; Single Lung Ventilation) pendant les chirurgies thoraciques entraîne des altérations cardio-pulmonaires et hémodynamiques importantes. L’objectif de ce projet de recherche consiste à étudier l’impact de la SLV sur l’oxymétrie cérébrale et sa relation avec les complications post opératoires. La première étude inclut vingt patients ayant subi une chirurgie thoracique nécessitant une SLV. L’oxymétrie a été mesurée à l’aide de l’oxymètre cérébral absolu FORESIGHTTM (CASMED, USA) afin d’étudier les changements de la saturation cérébrale absolue (SctO2) tout le long de la chirurgie. La SctO2 ainsi que les paramètres de monitorage standard (BIS, SpO2, pression sanguine, fréquence cardiaque) ont été notés à toutes les cinq minutes à partir de l’induction jusqu’au réveil. Une analyse sanguine (paO2, paCO2, Hb) a été effectuée à toutes les quinze minutes. La deuxième étude effectuée consistait d’étudier la relation entre la désaturation cérébrale en oxygène et les complications post opératoires. Pour cette fin, les scores Clavien et SOFA mesurant l’amplitude des complications, ont été établis pour chaque patient. Les données sont présentées sous forme de moyenne et de la médiane [1er quartile, 3ème quartile; min – max]. Les vingt patients de la première étude ont montré une valeur moyenne absolue de saturation cérébrale absolue (SctO2) de 80% avant l’induction. Durant la SLV, cette valeur a chuté jusqu’à 63% et est remontée à 71% directement après extubation. Tous ces patients ont subi une désaturation durant SLV de plus que 15% comparativement à la valeur de base et 70% ont eu une désaturation de plus de 20%. La désaturation n’a pas été corrélée avec aucun des paramètres de monitorage clinique standard comme la pression artérielle, les analyses des gaz artériels, la saturation périphérique ou la PaO2. La deuxième étude incluant trente autres patients aux vingt premiers, est venue confirmer les résultats de la première étude. De plus, une analyse de corrélation entre les valeurs minimales de SctO2 obtenues durant SLV et les complications post opératoires a été effectuée. Les patients avaient une SctO2 de base de 80%, qui a chuté jusqu’à 64% pendant la SLV pour récupérer à 71% avant la fin de la chirurgie. 82% des patients ont subi des désaturations de plus de 15% des valeurs initiales et 10% ont atteint des valeurs de SctO2 entre 45 et 55%. Les valeurs minimales de SctO2 observées durant la SLV corrélaient avec le score SOFA non respiratoire (R2=0,090, p=0,0287) ainsi qu’avec le score Clavien (R2=0,098, p=0,0201), mais ne corrélait avec aucun des paramètres cliniques standards (ex : SpO¬2, PaO2, PaCO2, Hb). En définissant une valeur seuil de SctO2=65%, le «Odds ratio» d’avoir une défaillance d’organe non respiratoire est de 2.37 (IC 95%=1,18 – 4,39, p=0,043) et d’avoir une complication classifiée supérieure à un score Clavien de 0 est de 3,19 (IC 95%=1,6 – 6,34, p=0,0272). Les chirurgies thoraciques avec une SLV sont associées à des chutes significatives de SctO2, et les valeurs minimales de SctO2 semblent avoir une corrélation positive avec les complications post opératoires.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Actualmente las técnicas de anestesia de tránsito rápido en cirugía cardiaca se basan en la utilización de remifentanil, sin embargo este al tener una vida media tan corta hace que sea necesaria la utilización de opioides durante el posoperatorio inmediato presentandose el riesgo de depresión ventilatoria, y complicaciones respiratorias, es por esto que la dexmedetomidina podría ser una opción bastante atractiva debida a que no produce depresión de los centros respiratorios, y disminuye el consumo de opioides en el postoperatorio hasta un 66%. Previa aprobación del comité de ética se realizó un estudio clínico controlado y aleatorizado en dos grupos de 20 pacientes, El primer grupo recibió inducción con propofol 2mg/Kg, pancuronio 0.8mg/kg, y fentanil 2mcg/kg seguido de un bolo de dexmedetomidina de 0.5mcg/kg y una infusión de 0.3 - 0.7 mcg/kg/h la cual fue suspendida al finalizar la colocación de los alambres esternales, el grupo de remifentanil recibió una inducción con propofol y pancuronio a las mismas dosis, seguido de una infusión de remifentanil de 0.1 - 0.5 mcg/kg/min suspendida al finalizar el cierre de la piel, ambos grupos recibieron analgesia con dipirona 50mg/kg, morfina 0.1mg/kg seguida de dosis de rescate de 3mg según necesidad, e infiltración de la herida quirurgica con 40cc de Bupivacaina al 0.25%. Se midio el tiempo y lugar de extubación, el consumo de medicamentos vasopresores y vasodilatadores durante la cirugiaasi como el consumo de morfina el VAS y la incidencia de nausea y vomito durante las primeras 24h posoperatorias. El 85% de los pacientes fueron extubados en salas de cirugia, sin encontrarse diferencias estadiscamente significativas entre los tiempos de extubación de ambos grupos (11.7min) para remifentanil, y (9.6min) para dexmedetomidina, en cuanto al consumo de morfina este fue significativamente menor en el grupo de dexmedetomidina 4mg vs 15mg en el grupo de remifentanil así como también lo fue la incidencia de nausea y vomito 42.9% remifentanil vs 5.2% dexmedetomidina p:0.00009. A nuestro saber este es el primer estudio clínico en la literatura en el cual se ha propuesto a la dexmedetomidina como una alternativa para técnicas anestésicas de transito rápido en cirugia cardiaca. Los resultados sugieren que es tan eficaz como el remifentanil para permitir la extubación temprana de este grupo de pacientes con una menor consumo de morfina y una menor incidencia de nauseas y vomito durante el posoperatorio. Se recomiendan la realización de estudios adicionales que permitan ratificar los resultados previamente encontrados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Evaluar si el Heliox reduce la resistencia en la vía aérea en niños y adolescentes con patología bronquial obstructiva que requieren ventilación mecánica. Materiales y Métodos: Estudio prospectivo observacional descriptivo en niños y adolescentes con patología bronquial obstructiva y ventilación mecánica con Fi02 ≤ 0,5. Medición de variables: resistencia, presión pico, presión media de la vía aérea, presión meseta, volumen corriente, autoPEEP, distensibilidad, PetCO2, ventilación de espacio muerto antes de inicio de heliox y a los 30 minutos, 2, 4, 6, 12, 18 y 24 horas y diariamente hasta suspenderlo por extubación o FiO2 > 0,5. Resultados: Resultados parciales, incluyó 9 pacientes encontrando descenso significativo de resistencia espiratoria a los 30 minutos (51,2 vs 32,3; p=0,0008 ), 2 horas ( 51,2 vs 33,4; p=0,0019) y 4 horas (51,2 vs 30,7; p=0,0012) así como de la resistencia inspiratoria a la hora 2 (48,6 vs 36,2; p = 0,013) y hora 4 (48,6 vs 30 ; p=0,004). Se observó tendencia al descenso de la PetCO2 que no fue significativa (52,3 vs 34,3: p=0,06). No se evidenció cambios en las variables; autoPEEP, presión pico, presión media de la vía aérea, distensibilidad, ventilación de espacio muerto, presión meseta y volumen corriente antes y después del inicio del Heliox. Conclusión: La ventilación mecánica con Heliox en niños con patología bronquial obstructiva parece ser que reduce de manera significativa la resistencia de la vía aérea, con tendencia al descenso de la PetC02. Se necesitan estudios prospectivos al menos observacionales analíticos que corroboren estos hallazgos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Caracterizar a los pacientes que recibieron ventilación mecánica en las unidades de cuidado intensivo (UCI) de la Fundación Santa Fe de Bogotá entre los años 2009 y 2013. Metodología: Se analizó una cohorte retrospectiva de los pacientes en UCI que requirieron soporte ventilatorio mecánico al ingreso a la unidad independientemente de la causa. Resultados: La media de edad de los pacientes fue 63,83 años; el diagnóstico más frecuente de ingreso fue revascularización miocárdica, seguido por neumonía y recambio valvular aórtico; en el 43% de los casos la causa de la falla fue el estado postoperatorio. Los modos ventilatorios más frecuentemente utilizados fueron SIMV (27,5%) y ventilación asistida controlada (26,12%). El 50% de los pacientes fueron ventilados con PEEP < 6 cmH2O. La mortalidad bruta fue del 15%. 22% de los pacientes tuvieron estancia prolongada en UCI. Se aplicó protocolo de retiro de ventilación mecánica en el 77% de los pacientes. La duración de la ventilación mecánica es mayor a medida que aumenta la edad del paciente entre los 60 y los 80 años. La mortalidad es cercana al 50% alrededor de los 50 años y mayor a 80% después de los 80 años. El soporte ventilatorio por cinco o más días aumentó la mortalidad a 80% o más. Discusión y Conclusiones: Estos resultados son comparables a los encontrados en estudios previos. Este estudio puede ser considerado como el primer paso para generar un registro adecuado de la ventilación de la mecánica de las unidades de cuidado intensivo del país.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Existen grupos quirúrgicos específicos donde es mandatorio el uso de relajantes neuromusculares no despolarizantes, como es el caso de los pacientes llevados a procedimiento de neurocirugía; debido a sus características particulares el rocuronio es una buena alternativa para este tipo de procedimientos, ya sea en bolos o en infusión. Sin embargo la relajación residual y los efectos adversos de los medicamentos para revertir la relajación neuromuscular deben tenerse en cuenta en este grupo de pacientes en particular. El presente trabajo busca comparar la reversión de la relajación de infusiones de rocuronio, con Neostigmina mas Atropina vs la reversión con Sugammadex en pacientes llevados a manejo quirúrgico de lesiones supratentoriales por parte del servicio de neurocirugía de la Fundación Cardioinfantil, evaluando complicaciones durante la administración de los medicamentos y 24 horas posoperatorias, así como los tiempos para extubación y salida de salas de cirugía. Estudio con características de experimento prospectivo, aleatorizado, ciego, controlado. En este documento se realiza un reporte preliminar descriptivo de 14 pacientes reclutados hasta la actualidad.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Determinar las lesiones laríngeas post-intubación endotraqueal en la unidad de cuidado intensivo (UCI) y cirugía ambulatoria y evaluar su asociación con respecto al tiempo de intubación y otras variables clínico-demográficas en un hospital universitario. Materiales y métodos: Estudio de cohorte analítico incluyendo 60 pacientes (30 de UCI y 30 de cirugía ambulatoria) a quienes se les realizó nasofibrolaringoscopia a las 24 horas post-extubación y a las 3 semanas de control y se registran las lesiones laríngeas encontradas. Resultados: En la primera endoscopia el 70% de los pacientes de cirugía ambulatoria presentaban al menos una lesión laríngea con un promedio de duración de intubación de 0.12 días DS±0.05 desapareciendo todas las lesiones en la segunda endoscopia. En el análisis del grupo de UCI se encontraron lesiones en el 76.6% de los pacientes con un promedio de duración de intubación de 6.0 días DS±3.3. La presencia de edema en pacientes con intubación prolongada por más de 6 días mostró diferencias estadísticamente significativa con respecto al grupo con menos días de intubación (RR 3.048, 95% IC 0.9-9.3, P=0.03) al igual que con antecedente de EPOC (P=0.032) y APACHE II mayor de 17 (RR 1.8, 95% IC 1.114-3.0, P=0.013). EPOC tiene una diferencia estadísticamente significativa con hiperemia (P=0.02) y granuloma (P=0.019). En la segunda endoscopia se encontró mayor frecuencia de hiperemia en los pacientes con intubación prolongada (>6 días) con una diferencia estadísticamente significativa (P=0.01). Conclusión: La intubación prolongada se encuentra asociada a la aparición edema e hiperemia en la laringe. EPOC y puntaje superior de APACHE II se relacionan con hiperemia y granulomas glóticos.