788 resultados para endoscopic examination


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to develop a standardized procedure for examination of the canine abdomen using endoscopic ultrasound and to describe the organs and structures that could be identified transgastrically. The abdomen of four healthy dogs and two cadavers were examined with endoscopic ultrasound. Five anatomic landmarks were used for standardized imaging of the cranial abdomen. These were the portal vein, splenic head and body, duodenum, left kidney, and aorta. High-resolution images of the following organs and structures could be made: distal esophagus, gastric wall from the cardia to the pylorus, liver, caudal vena cava, hepatic lymph nodes, liver hilus, and associated vessels, trifurcation of the celiac artery as well as the path of its branches and the left pancreatic limb and body. Structures that were more difficult to image were the distal duodenum and right pancreatic limb, the entire jejunum, ileum, and cecum as well as the tail of the spleen. Endoscopic ultrasound allowed excellent visualization of the gastric wall and regional structures without interference with gas artefacts. Centrally located organs such as the pancreas could be well examined transgastrically with endoscopic ultrasound without interference by overlying intestinal segments as is common with transabdominal ultrasound.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Initial presentation of a white female newborn delivered after normal pregnancy demonstrated a white mass obstructing the left nare. Primary biopsy revealed a focus of fibrotic nasal mucosa that included squamous and respiratory epithelium. After endoscopic resection of the mass, histopathologic examination resulted in the diagnosis of a teratoma. According to our literature review, this is the first case of a teratoma arising from the nasal septum in a white. Worldwide, 3 additional cases have been reported, but none included endoscopic management. This case illustrates our protocol for an endoscopic approach to an obstructive nasal mass in a neonate and our experience in the management of this rare disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Endoscopic ultrasound was developed initially in humans to overcome limitations of conventional ultrasound in examining certain internal organs due to intervening bone or air-filled structures. Endoscopic ultrasound has been used most widely in investigation of the gastrointestinal tract in humans, but many intrathoracic applications as well as endoscopic ultrasound-guided techniques have recently been described. Mediastinal and pulmonary structures can be examined with endoscopic ultrasound since a high frequency ultrasound probe can be brought into close contact with the areas of interest via a transesophageal approach. The purpose of this report is to describe the application of endoscopic ultrasound as an aid in the diagnosis of intrathoracic disease in the dog. Two dogs, one with a history of prior esophageal foreign body extraction, the other with apathy, weakness and dyspnea were referred for further investigation. Both dogs had caudal intrathoracic soft tissue opacities diagnosed radiographically, but their origin and nature were difficult to determine. Conventional ultrasound was limiting in both dogs due to their location and superimposition of gas-filled structures. With endosonography lesions were characterized more completely. We have found endoscopic ultrasound to be an elegant diagnostic tool for the investigation of radiographically detected intrathoracic lesions in the dog whose origins are difficult to determine or do not lend themselves to investigation by conventional ultrasound. Endoscopic ultrasound provides valuable diagnostic information complementary to that provided radiographically which aids in therapeutic planning. Endoscopic ultrasound was also more sensitive for detecting mediastinal lymphadenomegaly than radiography in one of the dogs. An additional advantage of endoscopic ultrasound is the fact that US-guided tissue sampling can be performed during the examination.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis presents an investigation on endoscopic optical coherence tomography (OCT). As a noninvasive imaging modality, OCT emerges as an increasingly important diagnostic tool for many clinical applications. Despite of many of its merits, such as high resolution and depth resolvability, a major limitation is the relatively shallow penetration depth in tissue (about 2∼3 mm). This is mainly due to tissue scattering and absorption. To overcome this limitation, people have been developing many different endoscopic OCT systems. By utilizing a minimally invasive endoscope, the OCT probing beam can be brought to the close vicinity of the tissue of interest and bypass the scattering of intervening tissues so that it can collect the reflected light signal from desired depth and provide a clear image representing the physiological structure of the region, which can not be disclosed by traditional OCT. In this thesis, three endoscope designs have been studied. While they rely on vastly different principles, they all converge to solve this long-standing problem.

A hand-held endoscope with manual scanning is first explored. When a user is holding a hand- held endoscope to examine samples, the movement of the device provides a natural scanning. We proposed and implemented an optical tracking system to estimate and record the trajectory of the device. By registering the OCT axial scan with the spatial information obtained from the tracking system, one can use this system to simply ‘paint’ a desired volume and get any arbitrary scanning pattern by manually waving the endoscope over the region of interest. The accuracy of the tracking system was measured to be about 10 microns, which is comparable to the lateral resolution of most OCT system. Targeted phantom sample and biological samples were manually scanned and the reconstructed images verified the method.

Next, we investigated a mechanical way to steer the beam in an OCT endoscope, which is termed as Paired-angle-rotation scanning (PARS). This concept was proposed by my colleague and we further developed this technology by enhancing the longevity of the device, reducing the diameter of the probe, and shrinking down the form factor of the hand-piece. Several families of probes have been designed and fabricated with various optical performances. They have been applied to different applications, including the collector channel examination for glaucoma stent implantation, and vitreous remnant detection during live animal vitrectomy.

Lastly a novel non-moving scanning method has been devised. This approach is based on the EO effect of a KTN crystal. With Ohmic contact of the electrodes, the KTN crystal can exhibit a special mode of EO effect, termed as space-charge-controlled electro-optic effect, where the carrier electron will be injected into the material via the Ohmic contact. By applying a high voltage across the material, a linear phase profile can be built under this mode, which in turn deflects the light beam passing through. We constructed a relay telescope to adapt the KTN deflector into a bench top OCT scanning system. One of major technical challenges for this system is the strong chromatic dispersion of KTN crystal within the wavelength band of OCT system. We investigated its impact on the acquired OCT images and proposed a new approach to estimate and compensate the actual dispersion. Comparing with traditional methods, the new method is more computational efficient and accurate. Some biological samples were scanned by this KTN based system. The acquired images justified the feasibility of the usage of this system into a endoscopy setting. My research above all aims to provide solutions to implement an OCT endoscope. As technology evolves from manual, to mechanical, and to electrical approaches, different solutions are presented. Since all have their own advantages and disadvantages, one has to determine the actual requirements and select the best fit for a specific application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Whipple's disease is a chronic systemic infection produced by the actinomycete Tropheryma whipplei. Endoscopic tests are key in the diagnosis as they allow biopsy and histopathological examination for definitive diagnosis of this entity. We present a case of Whipple's disease where capsule endoscopy, uncommon for the diagnosis of this condition, was essential for it and its performance before and after antibiotic treatment allows to describe the macroscopic evolution of the findings in the small bowel. This case illustrates the usefulness of capsule endoscopy to allow complete examination of the small bowel disease in which up to 30% of patients may present with normal endoscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prospective, consecutive series of 106 patients receiving endoscopic anterior scoliosis correction. The aim was to analyse changes in radiographic parameters and rib hump in the two years following surgery. Endoscopic anterior scoliosis correction is a level sparing approach, therefore it is important to assess the amount of decompensation which occurs after surgery. All patients received a single anterior rod and vertebral body screws using a standard compression technique. Cleared disc spaces were packed with either mulched femoral head allograft or rib head/iliac crest autograft. Radiographic parameters (major, instrumented, minor Cobb, T5-T12 kyphosis) and rib hump were measured at 2,6,12 and 24 months after surgery. Paired t-tests and Wilcoxon signed ranks tests were used to assess the statistical significant of changes between adjacent time intervals.----- Results: Mean loss of major curve correction from 2 to 24 months after surgery was 4 degrees. Mean loss of rib hump correction was 1.4 degrees. Mean sagittal kyphosis increased from 27 degrees at 2 months to 30.6 degrees at 24 months. Rod fractures and screw-related complications resulted in several degrees less correction than patients without complications, but overall there was no clinically significant decompensation following complications. The study concluded that there are small changes in deformity measures after endoscopic anterior scoliosis surgery, which are statistically significant but not clinically significant.