Nowadays, computer simulators are becoming basic tools for education and training in many engineering fields. In the nuclear industry, the role of simulation for training of operators of nuclear power plants is also recognized of the utmost relevance. As an example, the International Atomic Energy Agency sponsors the development of nuclear reactor simulators for education, and arranges the supply of such simulation programs. Aware of this, in 2008 Gas Natural Fenosa, a Spanish gas and electric utility that owns and operate nuclear power plants and promotes university education in the nuclear technology field, provided the Department of Nuclear Engineering of Universidad Politécnica de Madrid with the Interactive Graphic Simulator (IGS) of “José Cabrera” (Zorita) nuclear power plant, an industrial facility whose commercial operation ceased definitively in April 2006. It is a state-of-the-art full-scope real-time simulator that was used for training and qualification of the operators of the plant control room, as well as to understand and analyses the plant dynamics, and to develop, qualify and validate its emergency operating procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Steam Generator Tube Rupture (SGTR) sequences in Pressurized Water Reactors are known to be one of the most demanding transients for the operating crew. SGTR are a special kind of transient as they could lead to radiological releases without core damage or containment failure, as they can constitute a direct path from the reactor coolant system to the environment. The first methodology used to perform the Deterministic Safety Analysis (DSA) of a SGTR did not credit the operator action for the first 30 min of the transient, assuming that the operating crew was able to stop the primary to secondary leakage within that period of time. However, the different real SGTR accident cases happened in the USA and over the world demonstrated that the operators usually take more than 30 min to stop the leakage in actual sequences. Some methodologies were raised to overcome that fact, considering operator actions from the beginning of the transient, as it is done in Probabilistic Safety Analysis. This paper presents the results of comparing different assumptions regarding the single failure criteria and the operator action taken from the most common methodologies included in the different Deterministic Safety Analysis. One single failure criteria that has not been analysed previously in the literature is proposed and analysed in this paper too. The comparison is done with a PWR Westinghouse three loop model in TRACE code (Almaraz NPP) with best estimate assumptions but including deterministic hypothesis such as single failure criteria or loss of offsite power. The behaviour of the reactor is quite diverse depending on the different assumptions made regarding the operator actions. On the other hand, although there are high conservatisms included in the hypothesis, as the single failure criteria, all the results are quite far from the regulatory limits. In addition, some improvements to the Emergency Operating Procedures to minimize the offsite release from the damaged SG in case of a SGTR are outlined taking into account the offsite dose sensitivity results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

ABSTRACT The climate change, the quest for sustainability and the strong environmental pressures for alternatives to traditional fossil fuels have increased the interest in the search and use of renewable energy sources. Among them stands out the biomass of charcoal coming from renewable forests, widely used as a thermal reductant in the steel industry in the detriment of the use of mineral coal coke. This study aimed to compare different operating procedures of immediate chemical analysis of charcoal. Seven essays to immediate chemical analysis were compared, spread between procedures performed by Brazilian companies and laboratories, the test described by NBR 8112 and one realized with a thermogravimetric analyzer (TGA) using the parameters of the NBR 8112. There were significant differences in the volatiles matter content and consequently in the fixed carbon contents found. The differences between the procedures and the NBR 8112 were caused by an excess burning time, a mass sample above or below the standard or inappropriate container used for burning. It observed that the TGA appraisal of the volatiles content must be carried out with a burning time equal to 2 minutes to obtain results similar to those of the NBR 8112 norm. Moreover, the ash content values were statistically identical and the particles size did not influence the differences between means.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

On October 14, 2004, about 2215:06 central daylight time, Pinnacle Airlines flight 3701 (doing business as Northwest Airlink), a Bombardier CL-600-2B19, N8396A, crashed into a residential area about 2.5 miles south of Jefferson City Memorial Airport, Jefferson City, Missouri. The airplane was on a repositioning flight from Little Rock National Airport, Little Rock, Arkansas, to Minneapolis-St. Paul International Airport, Minneapolis, Minnesota. During the flight, both engines flamed out after a pilot-induced aerodynamic stall and were unable to be restarted. The captain and the first officer were killed, and the airplane was destroyed. No one on the ground was injured. The flight was operating under the provisions of 14 Code of Federal Regulations Part 91 on an instrument flight rules flight plan. Visual meteorological conditions prevailed at the time of the accident. The National Transportation Safety Board determines that the probable causes of this accident were (1) the pilots' unprofessional behavior, deviation from standard operating procedures, and poor airmanship, which resulted in an in-flight emergency from which they were unable to recover, in part because of the pilots' inadequate training; (2) the pilots' failure to prepare for an emergency landing in a timely manner, including communicating with air traffic controllers immediately after the emergency about the loss of both engines and the availability of landing sites; and (3) the pilots' improper management of the double engine failure checklist, which allowed the engine cores to stop rotating and resulted in the core lock engine condition. Contributing to this accident were (1) the core lock engine condition, which prevented at least one engine from being restarted, and (2) the airplane flight manuals that did not communicate to pilots the importance of maintaining a minimum airspeed to keep the engine cores rotating.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Applied Pharmaceutical Practice is an invaluable resource and will guide the student pharmacist and pharmacy technician through the main stages involved in pharmaceutical dispensing. As a core reference text, it is ideal as a companion to the compulsory dispensing courses found in all undergraduate MPharm programmes and the equivalent technical training courses. Contents include: •medicines classification and standard operating procedures •NHS supply in the community and within hospitals •non-NHS supply •controlled drugs •emergency supply •patient counselling and communication •poisons and spirits This practical textbook contains useful exercises with an answers section and numerous examples and is written by authors with extensive experience within the field. This is a comprehensive guide through the main stages of pharmaceutical dispensing.The textbook is designed to guide student pharmacists or pharmacy technicians through the main stages involved in pharmaceutical dispensing. It provides students with a core reference text to accompany the compulsory dispensing course found in all pharmacy undergraduate programmes, highlighting and explaining all key concepts behind the processes involved in pharmaceutical dispensing.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Applied Pharmaceutical Practice is an invaluable resource and will guide the student pharmacist and pharmacy technician through the main stages involved in pharmaceutical dispensing. As a core reference text, it is ideal as a companion to the compulsory dispensing courses found in all undergraduate MPharm programmes and the equivalent technical training courses. Contents include: •medicines classification and standard operating procedures •NHS supply in the community and within hospitals •non-NHS supply •controlled drugs •emergency supply •patient counselling and communication •poisons and spirits This practical textbook contains useful exercises with an answers section and numerous examples and is written by authors with extensive experience within the field. This is a comprehensive guide through the main stages of pharmaceutical dispensing.The textbook is designed to guide student pharmacists or pharmacy technicians through the main stages involved in pharmaceutical dispensing. It provides students with a core reference text to accompany the compulsory dispensing course found in all pharmacy undergraduate programmes, highlighting and explaining all key concepts behind the processes involved in pharmaceutical dispensing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this study, 20 Brazilian public schools have been assessed regarding good manufacturing practices and standard sanitation operating procedures implementation. We used a checklist comprised of 10 parts ( facilities and installations, water supply, equipments and tools, pest control, waste management, personal hygiene, sanitation, storage, documentation, and training), making a total of 69 questions. The implementing modification cost to the found nonconformities was also determined so that it could work with technical data as a based decision-making prioritization. The average nonconformity percentage at schools concerning to prerequisite program was 36%, from which 66% of them own inadequate installations, 65% waste management, 44% regarding documentation, and 35% water supply and sanitation. The initial estimated cost for changing has been U.S.$24,438 and monthly investments of 1.55% on the currently needed invested values. This would result in U.S.$0.015 increase on each served meal cost over the investment replacement within a year. Thus, we have concluded that such modifications are economically feasible and will be considered on technical requirements when prerequisite program implementation priorities are established.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Thin films consisting of 3 or 4 Sb and Ge alternating layers are irradiated with single nanosecond laser pulses (12 ns, 193 nm). Real time reflectivity (RTR) measurements are performed during irradiation, and Rutherford backscattering spectrometry (RBS) is used to obtain the concentration depth profiles before and after irradiation. Interdiffusion of the elements takes place at the layer interfaces within the liquid phase. The reflectivity transients allow to determine the laser energy thresholds both to induce and to saturate the process being both thresholds dependent on the multilayer configuration. It is found that the energy threshold to initiate the process is lower when Sb is at the surface while the saturation is reached at lower energy densities in those configurations with thinner layers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Assays that measure a patient's immune response play an increasingly important role in the development of immunotherapies. The inherent complexity of these assays and independent protocol development between laboratories result in high data variability and poor reproducibility. Quality control through harmonization--based on integration of laboratory-specific protocols with standard operating procedures and assay performance benchmarks--is one way to overcome these limitations. Harmonization guidelines can be widely implemented to address assay performance variables. This process enables objective interpretation and comparison of data across clinical trial sites and also facilitates the identification of relevant immune biomarkers, guiding the development of new therapies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper uses data on the world's copper mining industry to measure the impact on efficiency of the adoption of the ISO 14001 environmental standard. Anecdotal and case study literature suggests that firms are motivated to adopt this standard so as to achieve greater efficiency through changes in operating procedures and processes. Using plant level panel data from 1992-2007 on most of the world's industrial copper mines, the study uses stochastic frontier methods to investigate the effects of ISO adoption. The variety of models used in this study find that adoption either tends to improve efficiency or has no impact on efficiency, but no evidence is found that ISO adoption decreases efficiency.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A total of 190 research documents were identified in line with the criteria agreed between the researchers and the CAAB, and are included in the audit. The key findings from the analysis of the audit are as follows:    - Research identified in the audit has tended to focus on child protection and the child protection system generally, as well as sexual abuse. This research has primarily been undertaken by clinicians and academics, and spans across sectors.   - Over half, (110 or 58%) of the research falls under the heading of policy/practice reviews/analysis. This is further reflected in the fact that the research most commonly focused on operating procedures, followed by practice issues and the policy framework, both in studies with a single focus and those with multiple foci.   - The most common type of publication was peer reviewed article (74 or 39%), with commissioned research accounting for just 7% (13). This is in line with the findings that 68% (128) of commissioning/publishing bodies and 74% (139) of research bodies were in the academic sector.   - The research published and/or commissioned by the statutory sector follows the pattern found in the audit generally, with the most common type of study being policy/practice review/analysis (27 or 48%) and the most common focus being operating procedures (22 or 39%).   - Information sources rarely incorporated primary research with children, with only 14 studies (8%) citing direct contact with children and young people. Information on children was more commonly gathered from case files, professionals and family members.   - The topics covered in the identified research were very wide-ranging but closely related to the primary subject area (type of abuse) and the sector in which the research was located.   One conclusion stated that: There is a shortage of child protection-focused research on the factors that cause and perpetuate child abuse, such as homelessness, addiction, parental mental illness and domestic violence. The need for material on these areas is demonstrated by the nature and scale of reports to the child protection system and the removal of some children from their families into out of home care as a result of the above mentioned adversities.This resource was contributed by The National Documentation Centre on Drug Use.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Assays that measure a patient's immune response play an increasingly important role in the development of immunotherapies. The inherent complexity of these assays and independent protocol development between laboratories result in high data variability and poor reproducibility. Quality control through harmonization--based on integration of laboratory-specific protocols with standard operating procedures and assay performance benchmarks--is one way to overcome these limitations. Harmonization guidelines can be widely implemented to address assay performance variables. This process enables objective interpretation and comparison of data across clinical trial sites and also facilitates the identification of relevant immune biomarkers, guiding the development of new therapies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introduction. The purpose of this work was studied the magnitude, possible causes and contributing environmental factors in the waterbourne outbreaks appearance, in the performance area of the locality of Benaoján (Town of Málaga. Spain). Material/Methods. Analysis of the potability of the water and disinfection controls. Evaluation of the fulfillment of the quality of the drinking water and sanitary technical requirements of water supplies, pursuant to the Spanish regulation on public consumption waters. Results. We have been accomplished 110 potability analysis, proving that 13,4% of the samples do not comply with the potability criteria of the water. It were practiced 647 controls of disinfection, of those which 53% resulted not accordant. The design of the supply net is of the branching type and at least presents 30 blind branches, points where the water remains stagnant. The municipal waters service doesn´t make analytics controls of the quality of the water neither has implanted Standard Operating Procedures (SOPs) of the facilities of the supply. Discussion. Environmental research suggests that the public water supply net is a source of infection, problem related to the epidemic outbreaks appearance. Because of this the water consumption not treaty must be avoided.