989 resultados para delta-sigma modulation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A series of experiments have been conducted on cruciform specimens to investigate fatigue crack growth from circular notches under high levels of biaxial stress. Two stress levels (Δσ1= 380 and 560 MPa) and five stress biaxialities (λ=+1.0, +0.5, 0, −0.5 and −1.0; where λ=σ21 were adopted in the fatigue tests in type 316 stainless steel having a monotonic yield strength of 243 MPa. The results reveal that fatigue crack growth rates are markedly influenced by both the stress amplitude and the stress biaxiality. A modified model has been developed to describe fatigue crack growth under high levels of biaxial stress.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The reactions pi(-)p -> eta n and gamma p -> eta p are investigated within a dynamical coupled-channels model of meson production reactions in the nucleon resonance region The meson-baryon channels included are pi N, pi Delta, sigma N, and rho N The direct eta-photoproduction process is studied within a formalism based on a chiral constituent quark model approach, complemented with a one-gluon-exchange mechanism, to take into account the breakdown of the SU(6)circle times O(3) symmetry In the models search, the following known nucleon resonances are embodied S-11(1535), S-11(1650), P-11(1440), P-11(1710), P-13(1720), D-13(1520), D-13(1700), D-15(1675), and F-15(1680). Data for the pi(-)p -> eta n reaction from threshold up to a total center-of-mass energy of W approximate to 2 GeV are satisfactorily reproduced For the photoproduction channel: two additional higher mass known resonances, P-13(1900) and F-15(2000), are also considered However, reproducing the data for gamma p -> eta p requires, within our approach, two new nucleon resonances, for which we extract, mass and width

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paper details on-chip inductor optimization for a reconfigurable continuous-time delta-sigma (Δ-Σ) modulator based radio-frequency analog-to-digital converter. Inductor optimisation enables the Δ-Σ modulator with Q enhanced LC tank circuits employing a single high Q-factor on-chip inductor and lesser quantizer levels thereby reducing the circuit complexity for excess loop delay, power dissipation and dynamic element matching. System level simulations indicate at a Q-factor of 75 Δ- Σ modulator with a 3-level quantizer achieves dynamic ranges of 106, 82 dB and 84 dB for RFID, TETRA, and Galileo over bandwidths of 200 kHz, 10 MHz and 40 MHz respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The NMR spin coupling parameters, (1)J(N,H) and (2)J(H,H), and the chemical shielding, sigma((15)N), of liquid ammonia are studied from a combined and sequential QM/MM methodology. Monte Carlo simulations are performed to generate statistically uncorrelated configurations that are submitted to density functional theory calculations. Two different Lennard-Jones potentials are used in the liquid simulations. Electronic polarization is included in these two potentials via an iterative procedure with and without geometry relaxation, and the influence on the calculated properties are analyzed. B3LYP/aug-cc-pVTZ-J calculations were used to compute the V(N,H) constants in the interval of -67.8 to -63.9 Hz, depending on the theoretical model used. These can be compared with the experimental results of -61.6 Hz. For the (2)J(H,H) coupling the theoretical results vary between -10.6 to -13.01 Hz. The indirect experimental result derived from partially deuterated liquid is -11.1 Hz. Inclusion of explicit hydrogen bonded molecules gives a small but important contribution. The vapor-to-liquid shifts are also considered. This shift is calculated to be negligible for (1)J(N,H) in agreement with experiment. This is rationalized as a cancellation of the geometry relaxation and pure solvent effects. For the chemical shielding, U(15 N) Calculations at the B3LYP/aug-pcS-3 show that the vapor-to-liquid chemical shift requires the explicit use of solvent molecules. Considering only one ammonia molecule in an electrostatic embedding gives a wrong sign for the chemical shift that is corrected only with the use of explicit additional molecules. The best result calculated for the vapor to liquid chemical shift Delta sigma((15)N) is -25.2 ppm, in good agreement with the experimental value of -22.6 ppm.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The improvement of devices provided by Nanotechnology has put forward new classes of sensors, called bio-nanosensors, which are very promising for the detection of biochemical molecules in a large variety of applications. Their use in lab-on-a-chip could gives rise to new opportunities in many fields, from health-care and bio-warfare to environmental and high-throughput screening for pharmaceutical industry. Bio-nanosensors have great advantages in terms of cost, performance, and parallelization. Indeed, they require very low quantities of reagents and improve the overall signal-to-noise-ratio due to increase of binding signal variations vs. area and reduction of stray capacitances. Additionally, they give rise to new challenges, such as the need to design high-performance low-noise integrated electronic interfaces. This thesis is related to the design of high-performance advanced CMOS interfaces for electrochemical bio-nanosensors. The main focus of the thesis is: 1) critical analysis of noise in sensing interfaces, 2) devising new techniques for noise reduction in discrete-time approaches, 3) developing new architectures for low-noise, low-power sensing interfaces. The manuscript reports a multi-project activity focusing on low-noise design and presents two developed integrated circuits (ICs) as examples of advanced CMOS interfaces for bio-nanosensors. The first project concerns low-noise current-sensing interface for DC and transient measurements of electrophysiological signals. The focus of this research activity is on the noise optimization of the electronic interface. A new noise reduction technique has been developed so as to realize an integrated CMOS interfaces with performance comparable with state-of-the-art instrumentations. The second project intends to realize a stand-alone, high-accuracy electrochemical impedance spectroscopy interface. The system is tailored for conductivity-temperature-depth sensors in environmental applications, as well as for bio-nanosensors. It is based on a band-pass delta-sigma technique and combines low-noise performance with low-power requirements.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis presents a CMOS Amplifier with High Common Mode rejection designed in UMC 130nm technology. The goal is to achieve a high amplification factor for a wide range of biological signals (with frequencies in the range of 10Hz-1KHz) and to reject the common-mode noise signal. It is here presented a Data Acquisition System, composed of a Delta-Sigma-like Modulator and an antenna, that is the core of a portable low-complexity radio system; the amplifier is designed in order to interface the data acquisition system with a sensor that acquires the electrical signal. The Modulator asynchronously acquires and samples human muscle activity, by sending a Quasi-Digital pattern that encodes the acquired signal. There is only a minor loss of information translating the muscle activity using this pattern, compared to an encoding technique which uses astandard digital signal via Impulse-Radio Ultra-Wide Band (IR-UWB). The biological signals, needed for Electromyographic analysis, have an amplitude of 10-100μV and need to be highly amplified and separated from the overwhelming 50mV common mode noise signal. Various tests of the firmness of the concept are presented, as well the proof that the design works even with different sensors, such as Radiation measurement for Dosimetry studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gli oceani coprono quasi il 75% della superficie della terra ed esercitano una grande influenza sulla vita di tutte le specie viventi e sull’evoluzione del clima a livello planetario. I repentini cambiamenti climatici hanno reso sempre piú importante studiarne i comportamenti. L’analisi della salinitá degli oceani é estremamente importante per gli studi sull’ambiente marino; puó essere usata per tracciare le masse d’acqua, descrivendone i flussi e svelandone la correlazione con i processi climatici, puó essere di aiuto ai biologi per studiare gli organismi marini e costituisce un parametro fondamentale per una vasta gamma di sensori. Un sistema autonomo che misuri conducibilitá e temperatura é il primo strumento per determinare la salinitá dell’acqua, sul mercato sono presenti sí numerosi sensori a elevata accuratezza ma necessitano di ingombranti strumenti di laboratorio per funzionare. Sistemi di ridotte dimensioni non sono invece altrettanto accurati ed affidabili. Questa tesi mira a sviluppare un'interfaccia che permetta di analizzare conducibilitá e temperatura con un elevato livello di accuratezza. Particolare attenzione sará posta all’elaborazione delle misure effettuate e alla caratterizzazione degli errori e dell’accuratezza del sistema. Partendo da queste basi in futuro si potrá creare un sistema autonomo a bassissima potenza, alimentato da batterie, che, basandosi sull’iterazione fra il chip impedenziometrico e il PIC, permetta di fare misure per un ciclo di vita di qualche anno.

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Relevância:

80.00% 80.00%

Publicador:

Resumo:

2 scans - 1of2 = whole card, 2of2 = image alone

Relevância:

80.00% 80.00%

Publicador:

Resumo:

2 scans - 1of2 =as photo appears today, 2of2 = auto color corrected