804 resultados para dead space
Resumo:
OBJECTIVE: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. DESIGN: Prospective randomized crossover study. SETTING: ICUs in one adult and one children's hospital in Switzerland. PATIENTS: Thirty intubated stable, critically ill patients (20 adults and 10 children). INTERVENTIONS: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilatior (AutoInit). MEASUREMENTS AND RESULTS: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V(DS)), expiratory time constant (RC), tidal volume (VT, total respiratory frequency (f(tot), minute ventilation (MV), and maximal and mean airway pressure (Paw, max and Paw, mean) were calculated. Arterial blood gases were analyzed at the end of each period. Paw, max was significantly less with the AutoInit ventilator settings while f(tot) was significantly greater (P < 0.05). The other values were not statistically significant. CONCLUSIONS: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.
Resumo:
OBJECTIVE: Before a patient can be connected to a mechanical ventilator, the controls of the apparatus need to be set up appropriately. Today, this is done by the intensive care professional. With the advent of closed loop controlled mechanical ventilation, methods will be needed to select appropriate start up settings automatically. The objective of our study was to test such a computerized method which could eventually be used as a start-up procedure (first 5-10 minutes of ventilation) for closed-loop controlled ventilation. DESIGN: Prospective Study. SETTINGS: ICU's in two adult and one children's hospital. PATIENTS: 25 critically ill adult patients (age > or = 15 y) and 17 critically ill children selected at random were studied. INTERVENTIONS: To stimulate 'initial connection', the patients were disconnected from their ventilator and transiently connected to a modified Hamilton AMADEUS ventilator for maximally one minute. During that time they were ventilated with a fixed and standardized breath pattern (Test Breaths) based on pressure controlled synchronized intermittent mandatory ventilation (PCSIMV). MEASUREMENTS AND MAIN RESULTS: Measurements of airway flow, airway pressure and instantaneous CO2 concentration using a mainstream CO2 analyzer were made at the mouth during application of the Test-Breaths. Test-Breaths were analyzed in terms of tidal volume, expiratory time constant and series dead space. Using this data an initial ventilation pattern consisting of respiratory frequency and tidal volume was calculated. This ventilation pattern was compared to the one measured prior to the onset of the study using a two-tailed paired t-test. Additionally, it was compared to a conventional method for setting up ventilators. The computer-proposed ventilation pattern did not differ significantly from the actual pattern (p > 0.05), while the conventional method did. However the scatter was large and in 6 cases deviations in the minute ventilation of more than 50% were observed. CONCLUSIONS: The analysis of standardized Test Breaths allows automatic determination of an initial ventilation pattern for intubated ICU patients. While this pattern does not seem to be superior to the one chosen by the conventional method, it is derived fully automatically and without need for manual patient data entry such as weight or height. This makes the method potentially useful as a start up procedure for closed-loop controlled ventilation.
Resumo:
BACKGROUND: Abdominoperineal resection (APR) following radiotherapy is associated with a high rate of perineal wound complications. The anterolateral thigh (ALT) flap, combined with the vastus lateralis (VL) muscle, can cover complex perineal and pelvic anteroposterior defects. This is used for the first time transabdominally through the pelvis and the perineum (TAPP) in the infero-posterior directions; this technique has been described and illustrated in this study. METHODS: Among over 90 patients who underwent perineal reconstruction between May 2004 and June 2011, six patients presented high-grade tumours invading perineum, pelvis and sacrum, thereby resulting in a continuous anteroposterior defect. ALT + VL TAPP reconstructions were performed after extended APR and, subsequently, sacrectomy. Patients were examined retrospectively to determine demographics, operative time, complications (general and flap-related), time to complete healing and length of hospital stay. Long-term flap coverage, flap volume stability and functional and aesthetic outcomes were assessed. RESULTS: Mean operating time of the reconstruction was 290 min. No deaths occurred. One patient presented partial flap necrosis. Another patient presented a novel wound dehiscence after flap healing, due to secondary skin dissemination of the primary tumour. Following volumetric flap analysis on serial post-operative CT scans, no significant flap atrophy was observed. All flaps fully covered the defects. No late complications such as fistulas or perineal hernias occurred. Donor-site recovery was uneventful with no functional deficits. CONCLUSIONS: The use of the ALT + VL flap transabdominally is an innovative method to reconstruct exceptionally complex perineal and pelvic defects extending up to the lower back. This flap guarantees superior bulk, obliterating all pelvic dead space, with the fascia lata (FL) supporting the pelvic floor.
Resumo:
Large Hadron Collider (LHC) is the main particle accelerator at CERN. LHC is created with main goal to search elementary particles and help science investigate our universe. Radiation in LHC is caused by charged particles circular acceleration, therefore detectors tracing particles in existed severe conditions during the experiments must be radiation tolerant. Moreover, further upgrade of luminosity (up to 1035 cm-2s-1) requires development of particle detector’s structure. This work is dedicated to show the new type 3D stripixel detector with serious structural improvement. The new type of radiation-hard detector has a three-dimensional (3D) array of the p+ and n+ electrodes that penetrate into the detector bulk. The electrons and holes are then collected at oppositely biased electrodes. Proposed 3D stripixel detector demonstrates that full depletion voltage is lower that that for planar detectors. Low depletion voltage is one of the main advantages because only depleted part of the device is active are. Because of small spacing between electrodes, charge collection distances are smaller which results in high speed of the detector’s response. In this work is also briefly discussed dual-column type detectors, meaning consisting both n+ and p+ type columnar electrodes in its structure, and was declared that dual-column detectors show better electric filed distribution then single sided radiation detectors. The dead space or in other words low electric field region in significantly suppressed. Simulations were carried out by using Atlas device simulation software. As a simulation results in this work are represented the electric field distribution under different bias voltages.
Resumo:
Evaluar si el Heliox reduce la resistencia en la vía aérea en niños y adolescentes con patología bronquial obstructiva que requieren ventilación mecánica. Materiales y Métodos: Estudio prospectivo observacional descriptivo en niños y adolescentes con patología bronquial obstructiva y ventilación mecánica con Fi02 ≤ 0,5. Medición de variables: resistencia, presión pico, presión media de la vía aérea, presión meseta, volumen corriente, autoPEEP, distensibilidad, PetCO2, ventilación de espacio muerto antes de inicio de heliox y a los 30 minutos, 2, 4, 6, 12, 18 y 24 horas y diariamente hasta suspenderlo por extubación o FiO2 > 0,5. Resultados: Resultados parciales, incluyó 9 pacientes encontrando descenso significativo de resistencia espiratoria a los 30 minutos (51,2 vs 32,3; p=0,0008 ), 2 horas ( 51,2 vs 33,4; p=0,0019) y 4 horas (51,2 vs 30,7; p=0,0012) así como de la resistencia inspiratoria a la hora 2 (48,6 vs 36,2; p = 0,013) y hora 4 (48,6 vs 30 ; p=0,004). Se observó tendencia al descenso de la PetCO2 que no fue significativa (52,3 vs 34,3: p=0,06). No se evidenció cambios en las variables; autoPEEP, presión pico, presión media de la vía aérea, distensibilidad, ventilación de espacio muerto, presión meseta y volumen corriente antes y después del inicio del Heliox. Conclusión: La ventilación mecánica con Heliox en niños con patología bronquial obstructiva parece ser que reduce de manera significativa la resistencia de la vía aérea, con tendencia al descenso de la PetC02. Se necesitan estudios prospectivos al menos observacionales analíticos que corroboren estos hallazgos.
Resumo:
O objetivo do presente estudo foi desenvolver um snorquel (SNQ) de baixo custo para mensuração de parâmetros cardiorrespiratórios em natação. Para isso, a máscara do analisador de gases VO2000 (MASC) foi adaptada a um SNQ desenvolvido artesanalmente com espaço morto de 250ml. Oito participantes foram submetidos a dois testes incrementais (TI) em cicloergômetro utilizando a MASC e o SNQ. Os TI foram realizados até a exaustão voluntária e foram compostos por estágios de 3min com carga inicial e incrementos de 35W. em ambas as situações, amostras gasosas foram coletadas em intervalos de 10s para determinação dos volumes de oxigênio (VO2), gás carbônico (VCO2), ventilatório (VE) e mensuração da freqüência cardíaca (FC). A comparação dos parâmetros cardiorrespiratórios (VO2, VE, VCO2 e FC) mensurados com o SNQ e a MASC foi realizada com o teste t de Student para amostras dependentes, enquanto que o teste de correlação de Pearson e a análise gráfica de Bland e Altman foram utilizados para verificar as associações e concordância entre parâmetros. em todos os casos, o nível de significância foi de P < 0,05. A adequação das equações de correção para os valores provenientes do SNQ foi verificada pelos erros sistemáticos (bias), aleatórios (precisão) e acurácia (ac). Não foram observadas diferenças significativas entre os valores de VO2, VCO2 e FC obtidos com a MASC e SNQ. Os valores de VE mensurados com o SNQ foram significativamente superiores aos obtidos com a MASC. No entanto, todos os parâmetros apresentaram elevada concordância e coeficiente de correlação (0,88 a 0,97). Além disso, foram verificados reduzidos valores de bias (VO2 = 0,11L/min; VE = 4,11L/min; VCO2 = 0,54L/min; 8,87bpm), precisão (VO2 = 0,24L/min; VE = 11,02L/ min; VCO2 = 0,18L/min; 7,42bpm) e ac (VO2 = 0,27L/min; VE = 11,76L/min; VCO2 = 0,56L/min; 11,56bpm). Desse modo, pode-se concluir que o SNQ desenvolvido neste estudo possibilita a mensuração válida de parâmetros cardiorrespiratórios em natação.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
BACKGROUND: The time course of impairment of respiratory mechanics and gas exchange in the acute respiratory distress syndrome (ARDS) remains poorly defined. We assessed the changes in respiratory mechanics and gas exchange during ARDS. We hypothesized that due to the changes in respiratory mechanics over time, ventilatory strategies based on rigid volume or pressure limits might fail to prevent overdistension throughout the disease process. METHODS: Seventeen severe ARDS patients {PaO2/FiO2 10.1 (9.2-14.3) kPa; 76 (69-107) mmHg [median (25th-75th percentiles)] and bilateral infiltrates} were studied during the acute, intermediate, and late stages of ARDS (at 1-3, 4-6 and 7 days after diagnosis). Severity of lung injury, gas exchange, and hemodynamics were assessed. Pressure-volume (PV) curves of the respiratory system were obtained, and upper and lower inflection points (UIP, LIP) and recruitment were estimated. RESULTS: (1) UIP decreased from early to established (intermediate and late) ARDS [30 (28-30) cmH2O, 27 (25-30) cmH2O and 25 (23-28) cmH2O (P=0.014)]; (2) oxygenation improved in survivors and in patients with non-pulmonary etiology in late ARDS, whereas all patients developed hypercapnia from early to established ARDS; and (3) dead-space ventilation and pulmonary shunt were larger in patients with pulmonary etiology during late ARDS. CONCLUSION: We found a decrease in UIP from acute to established ARDS. If applied to our data, the inspiratory pressure limit advocated by the ARDSnet (30 cmH2O) would produce ventilation over the UIP, with a consequent increased risk of overdistension in 12%, 43% and 65% of our patients during the acute, intermediate and late phases of ARDS, respectively. Lung protective strategies based on fixed tidal volume or pressure limits may thus not fully avoid the risk of lung overdistension throughout ARDS.
Resumo:
Velopharyngeal insufficiency in cleft patients with muscular insufficiency detected by nasendoscopy is commonly treated by secondary radical intravelar veloplasty, in which the palatal muscles are reoriented and positioned backwards. The dead space between the retro-displaced musculature and the posterior borders of the palatal bone remains problematic. Postoperatively, the surgically achieved lengthening of the soft palate often diminishes due to scar tissue formation in the dead space, leading to reattachment of the reoriented muscles to the palatal bone and to decreased mobility of the soft palate. To avoid this, the dead space should be restored by a structure imitating the function of the missing palatal aponeurosis. The entire dead space was covered using a double layer of autogenous fascia lata harvested from the lateral thigh, which should allow sufficient and permanent sliding of the retro-positioned musculature. A clinical case of a 9-year-old boy who underwent the operation is reported. Postoperatively, marked functional improvements were observable in speech assessment, nasendoscopy and nasometry. The case reported here suggests that the restoration of the dead space may be beneficial for effective secondary palatal repair. Fascia lata seems to be a suitable graft for this purpose.
Resumo:
Soft tissue coverage of the medial ankle and foot remains a difficult, challenging, and often frustrating problem to patients as well as surgeons. To our knowledge, the abductor hallucis muscle flap is not frequently used and only a few well documented cases were found in literature. The purpose of this paper is to report and to present the long-term results of a series of four patients who underwent reconstruction of foot and ankle defects with the abductor hallucis muscle flap.In two cases, the abductor hallucis muscle flap was transposed in combination with a medialis pedis flap to cover a medial ankle defect, whereas in another case it was combined with a medial plantar flap. In this latter case, the muscle flap served to fill up a calcaneal dead space after osteomyelitis debridement, whereas the cutaneous flap was used to replace debrided skin at the heel. The abductor hallucis flap was used as a distally-based turnover flap to cover a large forefoot defect in a fourth case. Follow-up period ranged between 18 and 64 months (mean 43.3). In the early postoperative period, two flaps healed completely In two patients marginal flap necrosis occurred which was subsequently skin grafted. No donor-site complication occurred in any of the patients. In all cases, protective sensation of the skin was satisfactory as early as 6 months. In two cases mild hyperkeratosis at the skin graft border to the sole skin (non-weight bearing area of medial plantar and medialis pedis flap donor site) was present, but probably related to poor foot care. All patients were fully mobile as early as 3 months after treatment. In the long-term follow-up (43.3 months), all flaps provided with durable coverage. Functional gait deficit due to consumtion of the abductor hallucis muscle was not apparent.Our long-term results demonstrated that the abductor hallucis muscle flap is a versatile, and reliable flap suitable for the reconstruction of foot and ankle defects. Utilizing the abductor hallucis muscle as a pedicled flap (distally or proximally-based) with or without conjoined regional fasciocutaneous flaps offers a successful and durable alternative to microsurgical tree flaps for small to moderate defects over the calcaneus region, medial ankle, medial foot, and forefoot with exposed bone, tendon, or joint.
Resumo:
The aim of this study was to test the effect of cardiac output (CO) and pulmonary artery hypertension (PHT) on volumetric capnography (VCap) derived-variables. Nine pigs were mechanically ventilated using fixed ventilatory settings. Two steps of PHT were induced by IV infusion of a thromboxane analogue: PHT25 [mean pulmonary arterial pressure (MPAP) of 25 mmHg] and PHT40 (MPAP of 40 mmHg). CO was increased by 50 % from baseline (COup) with an infusion of dobutamine ≥5 μg kg(-1) min(-1) and decreased by 40 % from baseline (COdown) infusing sodium nitroglycerine ≥30 μg kg(-1) min(-1) plus esmolol 500 μg kg(-1) min(-1). Another state of PHT and COdown was induced by severe hypoxemia (FiO2 0.07). Invasive hemodynamic data and VCap were recorded and compared before and after each step using a mixed random effects model. Compared to baseline, the normalized slope of phase III (SnIII) increased by 32 % in PHT25 and by 22 % in PHT40. SnIII decreased non-significantly by 4 % with COdown. A combination of PHT and COdown associated with severe hypoxemia increased SnIII by 28 % compared to baseline. The elimination of CO2 per breath decreased by 7 % in PHT40 and by 12 % in COdown but increased only slightly with COup. Dead space variables did not change significantly along the protocol. At constant ventilation and body metabolism, pulmonary artery hypertension and decreases in CO had the biggest effects on the SnIII of the volumetric capnogram and on the elimination of CO2.
Resumo:
BACKGROUND AND OBJECTIVES Multiple-breath washout (MBW) is an attractive test to assess ventilation inhomogeneity, a marker of peripheral lung disease. Standardization of MBW is hampered as little data exists on possible measurement bias. We aimed to identify potential sources of measurement bias based on MBW software settings. METHODS We used unprocessed data from nitrogen (N2) MBW (Exhalyzer D, Eco Medics AG) applied in 30 children aged 5-18 years: 10 with CF, 10 formerly preterm, and 10 healthy controls. This setup calculates the tracer gas N2 mainly from measured O2 and CO2concentrations. The following software settings for MBW signal processing were changed by at least 5 units or >10% in both directions or completely switched off: (i) environmental conditions, (ii) apparatus dead space, (iii) O2 and CO2 signal correction, and (iv) signal alignment (delay time). Primary outcome was the change in lung clearance index (LCI) compared to LCI calculated with the settings as recommended. A change in LCI exceeding 10% was considered relevant. RESULTS Changes in both environmental and dead space settings resulted in uniform but modest LCI changes and exceeded >10% in only two measurements. Changes in signal alignment and O2 signal correction had the most relevant impact on LCI. Decrease of O2 delay time by 40 ms (7%) lead to a mean LCI increase of 12%, with >10% LCI change in 60% of the children. Increase of O2 delay time by 40 ms resulted in mean LCI decrease of 9% with LCI changing >10% in 43% of the children. CONCLUSIONS Accurate LCI results depend crucially on signal processing settings in MBW software. Especially correct signal delay times are possible sources of incorrect LCI measurements. Algorithms of signal processing and signal alignment should thus be optimized to avoid susceptibility of MBW measurements to this significant measurement bias.
Resumo:
Passive tilting increases ventilation in healthy subjects; however, controversy surrounds the proposed mechanism. This study is aimed to evaluate the possible mechanism for changes to ventilation following passive head-up tilt (HUT) and active standing by comparison of a range of ventilatory, metabolic and mechanical parameters. Ventilatory parameters (V (T), V (E), V (E)/VO2, V (E)/VCO2, f and PetCO(2)), functional residual capacity (FRC), respiratory mechanics with impulse oscillometry; oxygen consumption (VO2) and carbon dioxide production (VCO2) were measured in 20 healthy male subjects whilst supine, following HUT to 70 degrees and unsupported standing. Data were analysed using a linear mixed model. HUT to 70 degrees from supine increased minute ventilation (V (E)) (P < 0.001), tidal volume (V (T)) (P=0.001), ventilatory equivalent for O-2 (V (E)/VO2) (P=0.020) and the ventilatory equivalent for CO2 (V (E)/VCO2) (P < 0.001) with no change in f (P=0.488). HUT also increased FRC (P < 0.001) and respiratory system reactance (X5Hz) (P < 0.001) with reduced respiratory system resistance (R5Hz) (P=0.004) and end-tidal carbon dioxide (PetCO(2)) (P < 0.001) compared to supine. Standing increased V (E) (P < 0.001), V (T) (P < 0.001) and V (E)/VCO2 (P=0.020) with no change in respiratory rate (f) (P=0.065), V (E)/VO2 (P=0.543). Similar changes in FRC (P < 0.001), R5Hz (P=0.013), X5Hz (P < 0.001) and PetCO(2) (P < 0.001) compared to HUT were found. In contrast to HUT, standing increased VO2 (P=0.002) and VCO2 (P=0.048). The greater increase in V (E) in standing compared to HUT appears to be related to increased VO2 and VCO2 associated with increased muscle activity in the unsupported standing position. This has implications for exercise prescription and rehabilitation of critically ill patients who have reduced cardiovascular and respiratory reserve.
Resumo:
Background. Hydroxyethylstarch (HES) is a synthetic polymer of glucose that has been suggested for therapeutic use in long-term plasma expansion. The aim of this study was to test the hypothesis that the infusion of a small volume of HES may provide benefits in systemic and regional hemodynamics and metabolism in a brain-dead canine model compared with large volume crystalloid resuscitation. Methods. Fourteen mongrel dogs were subjected to a brain-death protocol by consecutive insufflations of a balloon catheter in the epidural space. One hour after induction of brain-death, the animals were randomly assigned to two groups: NS (0.9% NaCl, 33mL/kg), and HES (6% HES 450/0.7, 17mL/Kg). Systemic and regional hemodynamics were evaluated using Swan-Ganz, ultrasonic flowprobes, and arterial catheters. Serial blood samples were collected for blood gas, electrolyte, and serum chemistry analysis. Systemic, hepatic, and splanchnic O(2)-derived variables were also calculated. Results. Epidural balloon insufflations induced a significant increase in mean arterial pressure, cardiac output (MAP and CO, respectively), regional blood flow, and systemic vascular resistance. Following the hyperdynamic phase, severe hypotension with normalization of systemic and regional blood flow was observed. Fluid resuscitation induced a prompt increase in MAP, CO, and portal vein blood flow, and a significant reduction in systemic and pulmonary vascular resistance. There were no differences between groups in metabolic indices, liver function tests (LFTs), or renal function tests. HES was more effective than NS in restoring cardiac performance in the first 2h after fluid resuscitation (P < 0.05). Both tested solutions partially and temporarily restored systemic and regional oxygen delivery. Conclusion. Small volumes of 6% HES 450/0.7 improved cardiovascular performance and provided the same regional hemodynamic and metabolic benefits of large volumes of isotonic crystalloid solutions. (C) 2011 Elsevier Inc. All rights reserved.
Resumo:
In the context of the administration of spaces assigned by municipalities for the burial of the dead, this article provides a critical analysis of the techniques for the governance of political collectives of citizens implemented by public authorities. More broadly, this article shows how funerary practices (i.e. the social practices surrounding death-the rituals, the legislation, etc.) can be used to develop a critical reading of the social relations that structure the social production of space. To this end, the authors use the conceptual tools provided by critical legal geography to explore the controversy surrounding the development of a 'carré confessionnel' (denominational area) within the Bois-de-Vaux Cemetery in Lausanne, Switzerland. Here, a focus on the techniques that allow 'nomosphere' technicians to convene a subset of the citizens within the public space reveals the administration of cemeteries as a means of governance, a method for mobilising bodies and a paradoxical means of managing flux.