993 resultados para capillary blood
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Purpose: The relationship between six descriptors of lactate increase, peak (V) over dot O-2,W-peak, and 1-h cycling performance were compared in 24 trained, female cyclists (peak (V) over dot O-2 = 48.11 +/- 6.32 mL . kg(-1) . min(-1)). Methods: The six descriptors of lactate increase were: 1) lactate threshold (LT; the power output at which plasma lactate concentration begins to increase above the resting level during an incremental exercise test), 2) LT1 (the power output at which plasma lactate increases by 1 mM or more), 3) LTD (the lactate threshold calculated by the D-max method), 4) LTMOD (the lactate threshold calculated by a modified D-max method), 5) L4 (the power output at which plasma lactate reaches a concentration of 4 mmol-L-1), and 6) LTLOG (the power output at which plasma lactate concentration begins to increase when the log([La-]) is plotted against the log (power output)). Subjects first completed a peak (V) over dot O-2 test on a cycle ergometer. Finger-tip capillary blood was sampled within 30 s of the end of each 3-min stage for analysis of plasma lactate. Endurance performance was assessed 7 d later using a 1-h cycle test (OHT) in which subjects were directed to achieve the highest possible average power output. Results: The mean power output (W) for the OHT (+/- SD) was 183.01 +/- 18.88, and for each lactate variable was: LT (138.54 +/- 46.61), LT1 (179.17 +/- 27.25), LTLOG (143.97 +/- 45.74), L4 (198.09 +/- 33.84), LTD (178.79 +/- 24.07), LTMOD (212.28 +/- 31.75). Average power output during the OHT was more strongly correlated with all plasma lactate parameters (0.61 < r < 0.84) and W-peak (r = 0.81) than with peak (V) over dot O-2 (r = 0.55). The six lactate parameters were strongly correlated with each other (0.54 < r < 0.91) and of the six lactate parameters, LTD correlated best with endurance performance (r = 0.84). Conclusions: It was concluded that plasma lactate parameters and W-peak provide better indices of endurance performance than peak (V) over dot O-2 and that, of the six descriptors of lactate increase measured in this study, LTD is most strongly related to 1-h cycling performance in trained, female cyclists.
Resumo:
To determine the precision and agreement of the hemoglobin (Hb) measurements in capillary and venous blood samples by the HemoCue® and an automated counter. Hb was determined by both equipaments in blood samples of 29 pregnant women. The HemoCue® showed low repeatability of Hb measurements in duplicate in capillary (CR=0.53 g/dL, CV=13.6%) and venous blood (CR=0.53 g/dL, CV=13.6%). Hb measurements in capillary blood were higher than those in venous blood (12.4 and 11.7 g/dL, respectively; p<0.05). There was high agreement between Hb in capillary blood by the HemoCue® and in venous blood by the counter (r icc=0.86; p<0.01), and also between the diagnosis of anemia by both equipments (k=0.81; p<0.01). The HemoCue® seems to be more appropriate for capillary blood and require training of the measurers.
Resumo:
Resumo Uma estratégia de avaliação e prevenção de riscos na exposição a agentes químicos deve ter sempre em conta que a vigilância do ambiente de trabalho e a da saúde dos trabalhadores são aspectos complementares de uma mesma realidade – os riscos resultantes da interacção entre um agente químico e os trabalhadores a ele expostos. Se à Vigilância Ambiental compete apreciar o risco, pela caracterização do agente no ambiente de trabalho, a Vigilância Biológica pronuncia-se sobre a interacção entre o tóxico e o organismo, avaliando a resposta à agressão química e a evolução das reacções de adaptação ou de desajuste face à absorção do tóxico. Os Indicadores Biológicos, deste modo, assumem um estatuto de instrumento privilegiado na vigilância da saúde dos trabalhadores expostos, na medida em que medem a quantidade de tóxico que efectivamente penetrou e foi absorvido, ou o resultado (efeito) determinado por essa mesma dose. O presente estudo procura contribuir para a definição de um quadro metodológico de utilização dos Indicadores Biológicos na avaliação/gestão da exposição profissional ao chumbo, designadamente apreciando a variação da protoporfirina-zinco (PPZ), indicador até ao presente ainda não utilizado em Portugal. O chumbo é um metal de ocorrência natural, cujos níveis nos diversos ecossistemas resultam, principalmente, das actividades antropogénicas de natureza doméstica e industrial. A sua capacidade poluente é assinalável, representando uma fonte de exposição permanente para o homem, demonstrável pela sua constante presença no organismo apesar de não desempenhar qualquer tipo de função fisiológica. São actualmente inúmeras as suas aplicações, tornando a exposição profissional ao chumbo uma realidade vasta: indústrias de acumuladores eléctricos, de vidros, de plásticos e de munições, construção civil, manutenção e reparação automóvel e de navios, fabrico de tintas, indústrias electrónicas, fundições e actividades de soldadura são, entre outras, situações onde é uma realidade a ter em conta. A penetração dos compostos inorgânicos de chumbo no organismo efectua-se principalmente por via respiratória, não sendo, no entanto, desprezável, a sua penetração por via digestiva. As partículas absorvidas são transportadas pelo sangue principalmente ligadas aos eritrocitos (95%), distribuem-se pelos tecidos moles e depositam-se essencialmente no tecido ósseo, onde representam mais de 90% da carga corporal do total absorvido e tendo aí um elevado tempo de semi-vida (mais de 20 anos). Não é metabolizado no organismo e a sua eliminação efectua-se essencialmente por via renal,sendo igualmente excretado, em menor escala, através das fezes, do suor, da saliva, das faneras e do leite materno. O conhecimento científico evidencia que concentrações sanguíneas de chumbo entre 20 e 50 mg/dL são susceptíveis de determinar efeitos adversos no homem, podendo ser afectados o sistema hematopoiético, o sistema nervoso, o sistema cardiovascular, o sistema reprodutor e o sistema imunitário. Contudo, ainda muito há a clarificar no âmbito da toxicidade do chumbo. Os níveis de exposição a que correspondem as alterações nos diversos órgãos e sistemas continuam a ser motivo de alguma controvérsia. As características carcinogénicas e mutagénicas do chumbo são, ainda, um campo de vasta exigência de investigação. A intoxicação por chumbo e seus sais (Saturnismo) de origem ocupacional é reconhecida em Portugal como doença profissional (grupo 1 - Doenças Provocadas por Agentes Químicos, da Lista das Doenças Profissionais). É uma intoxicação do tipo crónico, fruto da absorção contínua de doses relativamente pequenas durante longo período, evidenciando-se no seu início por sinais e sintomas vagos e difusos de grande inespecificidade, que podem incluir, nomeadamente, perda de apetite, sabor metálico na boca, palidez, mal-estar e fadiga, cefaleias, mialgias e artralgias, irritabilidade, tremores finos, obstipação, cólicas abdominais, insónias, déficit da memória de curto prazo e da capacidade de concentração. Um importante conjunto de indicadores biológicos pode ser utilizado na vigilância periódica da saúde de trabalhadores nestas condições de exposição. Tais indicadores (de dose ou de efeito), encerram diferentes significados e comportam distintas exigências, competindo ao Médico do Trabalho, no âmbito dos programas de prevenção dos efeitos adversos relacionados com a exposição profissional a chumbo, seleccionar a sua utilização e interpretar a sua informação, de modo a avaliar a interacção do tóxico com o organismo numa fase de reversibilidade. O presente estudo envolveu 180 trabalhadores dos quais 110 apresentavam plumbémias (Pb-S) iguais ou superiores a 40 mg/dL. Além da Pb-S, a todos foi doseada a protoporfirina-zinco (PPZ) e efectuado o Hemograma e a cerca de 25% foi determinada a concentração do ácido d-aminolevulínico urinário (ALA-U). Os doseamentos da PPZ efectuados em amostra de sangue capilar através de um hematofluorímetro portátil revelaram-se de total fiabilidade, dando significado a uma técnica de fácil execução e baixo custo. A avaliação do tipo de colheita urinária para doseamento do ALA-U concluiu pela necessidade de recurso a urinas de 24 horas.Os resultados do estudo evidenciaram uma elevada associação entre a PPZ e a Pb-S, com uma maior magnitude e de início mais precoce do que o que registado na associação da Pb-S com o ALA-U. Revelaram, ainda, fracos níveis de associação da hemoglobina (e outros parâmetros hematológicos) com a Pb-S. E demonstraram para um cut-off de 100 mg/ dL de PPZ, taxa de falsos negativos e falsos positivos, para plumbémias a partir de 70 mg/dL, inferiores a 20%. Assim, concluiu-se que, nos protocolos de vigilância de saúde de trabalhadores expostos a chumbo, o doseamento da PPZ por hematofluorímetro, em sangue de colheita capilar, é adequado, fiável e de realização preferencial em relação ao do ALA-U. Concluiu-se, também, que a realização do hemograma apenas se justifica em situações individuais que clinicamente o tornem aconselhável. E que estes protocolos devem incluir a realização da Pb-S e da PPZ, podendo, em situações de controlo rigoroso (ambiental, biológico e clínico), basear-se apenas na determinação da PPZ reservando os outros indicadores para aprofundar a investigação médica nos casos de taxas elevadas desta ou de situações limitantes. ■ Résumée Une stratégie d’évaluation et de prévention des risques d’exposition aux agents chimiques doit toujours tenir en considération que la vigilance du lieu de travail et de la santé des travailleurs sont des aspects complémentaires d’une même réalité – les risques résultant d’une interaction entre l’agent chimique et les travailleurs exposés. Si c’est à la Vigilance Ambiantale de juger le risque, par la caractérisation de l’agent dans le lieu de travail, la Vigilance Biologique, elle, se prononce sur l’interaction entre le toxique et l’organisme, évaluant la réponse à l’agression chimique et l’évolution des réactions d’adaptation ou de rupture face à l’absorption du toxique. Les Indicateurs Biologiques assument ainsi un statut d’instrument privilégié de vigilance de la santé des travailleurs exposés, dans la mesure où ils déterminent la quantité de toxique qui a effectivement été pénétré et absorbé, ou le résultat (effet) déterminé par cette dose. Cette étude-ci cherche à contribuer à la définition d’un cadre méthodologique d’utilisation des Indicateurs Biologiques dans l’évaluation/ gestion de l’exposition professionnelle au plomb inorganique, évaluant spécialement le comportement de la protoporphirine-zinc (PPZ), indicateur pas encore utilisé au Portugal.Le plomb est un métal d’occurrence naturelle dont les niveaux dans les différents écosystèmes en résultent, principalement, des activités anthropogéniques de nature domestique et industrielle. Sa capacité polluante peut être signalée, représentant une source d’exposition permanente pour l’homme, celle-ci démontrable par sa présence continue dans l’organisme, même si elle n’y accomplit aucune fonction physiologique. Actuellement ses applications sont innombrables, faisant de l’exposition professionnelle au plomb une réalité de grande ampleur : industries d’accumulateurs électriques, de verre, de plastique et de munitions, bâtiments, manutention et réparation automobile et navale, fabrication d’encres, industries électroniques, fontes et activités de soudure sont, entre autres, des situations réelles a en tenir compte. La pénétration du plomb inorganique dans l’organisme se fait principalement par voie respiratoire, pouvant se faire également par voie digestive. Les particules absorbées sont transportées par le sang, surtout liées aux érythrocytes (95%), se repartent à travers les tissus mous et se déposent essentiellement dans le tissu osseux, où elles représentent plus de 90% de la charge corporelle de ce qui a été absorbé et ont un temps de demi-vie élevé (plus de 20 ans). Le plomb n’est pas métabolisé dans l’organisme et son élimination se fait essentiellement par voie rénale, pouvant tout de même, à une moindre échelle, être excrété dans les fèces, de la sueur, de la salive, des ongles, des cheveux et du lait maternel. La connaissance scientifique met en évidence que des concentrations sanguines de plomb entre 20 et 50 mg/dL sont susceptibles de déterminer des effets adverses dans l’homme, pouvant les systèmes hématopoïétique, nerveux, cardiovasculaire, reproducteur et immunitaire en être affectés. Cependant, il en reste beaucoup à éclaircir dans le domaine de la toxicité du plomb. Les niveaux d’exposition auxquels correspondent les modifications des divers organes et systèmes, demeurent toujours sujet de quelque controverse. Les caractéristiques carcinogèniques et mutagèniques du plomb restent toujours un champ d’investigation d’une grande exigence. L’intoxication par le plomb et ses sels (Saturnisme) d’origine occupationnelle est reconnue, au Portugal, comme une maladie professionnelle (groupe 1- Maladies Provoquées par des Agents Chimiques, de la Liste des Maladies Professionnelles). C’est une intoxication du tipe chronique, due à l’absorption continue de doses relativement petites pendant une longue période, mise en évidence à travers des signes et des symptômes vagues et diffus sans grande spécificité, lesquels peuvent inclure, particulièrement, le manque d’appétit, goût métallique dans la bouche, pâleur, malaise et fatigue, céphalées, myalgies et arthralgies, irritabilité, tremblements fins, constipation, coliques abdominales, insomnies, déficit de la mémoire à court terme et de la capacité de concentration.Un ensemble important d’indicateurs biologiques peut être employé dans la vigilance périodique de la santé des travailleurs dans ces conditions d’exposition. Ces indicateurs (de dose ou d’effet) renferment différentes significations et comportent diverses exigences, devant le Médecin de Travail, dans le domaine des programmes de prévention des effets adverses qui sont en relation avec l’exposition professionnelle au plomb, sélectionner son utilisation et interpréter son information de façon à évaluer l’interaction de l’élément toxique avec l’organisme à un stade de réversibilité. L’étude ci-présent engloba 180 travailleurs desquels 110 présentaient des plombémies (Pb-S) égales ou supérieures à 40 mg/dL. À part la Pb-S, la protoporphyrine-zinc (PPZ) leur a été prise en dosage et un Hémogramme fut effectué et fut déterminé l’acide d- aminolévulinique urinaire (ALA-U) sur environ 25% des travailleurs. Le dosage de la PPZ efectué en échantillon de sang capillaire par un fluorimètre portable, s’est accomplit d’une fiabilité total, donnant du sgnificat à une téchnique de facile execution et bas prix. L’évaluation de la prise urinaire par dosage du ALA-U conclut au besoin d’un recours aux urines de 24 heures Les résultats de l’étude ont mis en évidence une association élevée entre la PPZ et la Pb- S, avec une intensité majeure et de début plus précoce par rapport à celui qui fut registré lors de l’association de la Pb-S avec la ALA-U. Ces résultats ont également montré de faibles niveaux d’association entre l’hémoglobine (et autres paramètres hématologiques) et la Pb-S. Ils ont démontré aussi, une valeur de cut-off de 100 mg/dL de PPZ, des taux de faux négatifs et faux positifs, pour des plombémies de 70 mg/dL, inférieurs à 20%. On peut donc conclure que dans les protocoles de vigilance de la santé des travailleurs exposés au plomb, le dosage de la PPZ par fluorimetrie dans le sang capillaire est adéquat, fiable et de réalisation préférentielle par rapport à celui du ALA-U. On peut également conclure que la réalisation de l’hémogramme ne se justifie que dans les cas individuels où, cliniquement, celui-ci est conseillé. De plus, ces protocoles doivent inclure la réalisation de la Pb-S et de la PPZ, pouvant, en cas de contrôle rigoureux (ambiantal, biologique et clinique), s’appuyer que dans la détermination de la PPZ réservant les autres indicateurs pour approfondir l’investigation médicale dans les cas où les taux de celle-ci sont élevés ou dans les cas de situations limitantes. ■ Summary Any strategy to evaluate and prevent the risks of chemical agents exposure must always regard the work environment and workers health as complementary aspects of one reality - the resulting risks from the interaction between the chemical agent and the exposed workers. It is the responsibility of Environmental Monitoring to evaluate the risks of exposure by the characterization of the chemical agent in the work environment. Biological Monitoring, on the other hand, pronounces itself over the toxin and body interaction, evaluating human response to the chemical aggression and the body adaptations to the toxic absorption. Biological Exposure Indices (BEI) assume, therefore, a privileged status among exposed workers' health monitoring instruments, as they measure the actual penetrated and absorbed toxic quantity and the effect it produces. This research study aims to contribute to the definition of a methodological strategy on the utilization of BEI’s in evaluating inorganic lead's occupational exposure, more specifically appreciating the zinc protoporphyrin (ZPP) variation, an index that has never been taken under consideration in Portugal until now. Lead is a natural metal whose ecosystem’s levels are mainly due to domestic and industrial anthropogenic activities. Its pollutant capacity is notable, representing a permanent exposure risk shown by its constant presence in the human body, although it has no physiologic function. Nowadays, lead's applications are countless, turning its professional exposure a huge reality: storage batteries industries, glass industries, plasterers and munitions industries, building construction, ships and motor car maintenance and repairing, ink manufacture, electronics industries, foundries and other soldering activities are, among so many other, realities to attend to. Respiration is the main cause of human body's inorganic lead absorption, although digestive pathway must not to be ignored. The absorbed particles are transported by blood, essentially bounded to erythrocytes (95%). It is distributed by soft tissues and settled mainly on bone tissues, where it represents approximately 90% of the total body charge and has a high half-life time (more than 20 years). It is not metabolized by the organism, its elimination being effectuated by renal activity and, in smaller scale, through lees, sweat, saliva, nails, hair and maternal milk.Scientific knowledge shows that concentrations of lead in blood between 20 e 50 mg/dL are susceptible to determine adverse effects in man and able to affect the hematopoietic system, the nervous system, the cardiovascular system, the reproductive system and the immunological system. Nevertheless, there's still much to be learned and clarified about lead's toxicity. The correlation between exposure levels and human's systems and organs alteration levels continues to be a centre of controversies. Still, lead's carcinogenic and mutagenic characteristics continue to be a high demanding research field. Intoxication by lead and its compounds (saturnism), from occupational origin, is recognized in Portugal as an occupational disease, included in Group 1 - Chemical Agents Caused Diseases, on the Occupational Diseases List. It is a chronic intoxication caused by a continuous absorption of small doses, throughout a long period of time. Its signs and symptoms are diffuse and imprecise, of great unspecificity, such as loss of appetite, metallic flavor in the mouth, paleness, ailment and fatigue, headaches, myalgia and arthralgia, irritability, thin tremors, constipation, abdominal pain, insomnias, short memory loses and inability to concentrate. A considered number of BEI’s can be used in Periodic Health Monitoring of workers in such exposure conditions. Such BEI (dose indices or effect indices) provide different meanings and imply different procedures, being Occupational Doctors responsibility, in the context of lead related adverse effects preventive programmes, to select and interpret its information, in order to evaluate the interaction between toxic and organism in a reversible phase of the toxic action. The present research study involved 180 workers, 110 of which presented blood lead levels (PbB) above or equal to 40 mg/dL. Besides PbB, all workers has been evaluated for zinc protoporphyrin levels (PPZ) and submitted to a haemogram. About 25% of the workers were selected for d-aminolevulinic urinary acid (ALA-U) determination. The evaluation of PPZ, by a portable hematofluorometer using capillary blood samples, turned out to be an easy procedure with low costs and total warrantability. As in regard for ALA- U procedure, it was concluded the necessity of 24 hours urine samples. This research results underlined a strong connection between ZPP and PbB, which was found to to be stringer and to begin earlier than it was registered for PbB and ALA-U association. The same study also revealed a low association level between PbB and hemoglobin or other hematological indices. It was also verified less than 20% of false negatives and false positives cases when admitted a ZPP 100 mg/dL cut off value for PbB³ 70 mg/dL. As in result it was concluded that in Health Monit
Resumo:
The colony of urban stray cats living in the Rio de Janeiro zoological garden was studied in order to develop a population and health control program. As many cats as possible were captured during two months (47 animals) and were classified according to gender, age, weight and coat markings. They were submitted to a general health evaluation, examined for the presence of ectoparasites and sent to a surgical neutering program. All animals had a blood sample drawn for CBC, platelet count, heartworm and retroviruses detection. Capillary blood smears were made for hemoparasites detection. Coat marking and colors were tabby (59.7%), followed by solid black (17%); torbie (10.6%); bicolor (10.6%) and harlequin (2.1%). The only ectoparasites found were fleas, which infested 28% of the animals. The hemoparasites found were Haemobartonella felis (38%) and piroplasmas that could not be differentiated between Cytauxzoon spp. and Babesia spp. (47%). No cat was found infected by Dirofilaria immitis or FeLV (Feline Leukemia Virus), although FIV (Feline Immunodeficiency Virus) antibodies could be detected (21%). There was no correlation between hemoparasites and FIV infections. The estimated total cat population (mark-recapture method) was 59; 68% female and 32% male, suggesting that a neutering program is in fact needed.
Resumo:
Introduction Since the launch of the Global Programme to Eliminate Lymphatic Filariasis, more than 70% of the endemic countries have implemented mass drug administration (MDA) to interrupt disease transmission. The monitoring of filarial infection in sentinel populations, particularly schoolchildren, is recommended to assess the impact of MDA. A key issue is choosing the appropriate tools for these initial assessments (to define the best intervention) and for monitoring transmission. Methods This study compared the pre-MDA performance of five diagnostic methods, namely, thick film test, Knott's technique, filtration, Og4C3-ELISA, and the AD12-ICT card test, in schoolchildren from Brazil. Venous and capillary blood samples were collected between 11 pm and 1 am. The microfilarial loads were analyzed with a negative binomial regression, and the prevalence and associated 95% confidence intervals were estimated for all methods. The accuracies of the AD12-ICT card and Og4C3-ELISA tests were assessed against the combination of parasitological test results. Results A total of 805 schoolchildren were examined. The overall and stratified prevalence by age group and gender detected by Og4C3-ELISA and AD12-ICT were markedly higher than the prevalence estimated by the parasitological methods. The sensitivity of the AD12-ICT card and Og4C3-ELISA tests was approximately 100%, and the positive likelihood ratios were above 6. The specificity of the Og4C3-ELISA was higher than that of the AD12-ICT at different prevalence levels. Conclusions The ICT card test should be the recommended tool for monitoring school-age populations living in areas with ongoing or completed MDA.
Resumo:
In previous years, several publications have reported cases of infants presenting neurological and gastrointestinal symptoms after ingestion of star anise tea. Such teas are sometimes given in various cultures for the treatment of infant colic pains. In most cases, the cause of intoxication was contamination of Chinese star anise (Illicium verum) by Japanese star anise (Illicium anisatum). Indeed, the toxicity of Illicium anisatum, also known as Shikimi, is caused by its content in potent neurotoxins (anisatin, neoanisatin, and pseudoanisatin), due to their activity as non-competitive antagonists of GABA receptors. The main reasons explaining the frequent contaminations are the strong macroscopic resemblance of the 2 substances, as well as the fact that the fruits are often sold partially broken or in ground form. Therefore, in most cases, chemical analysis is required to determine the possible adulterations. CASE REPORT: A 2-month-old infant, in good general health, was brought to the emergency unit after 3 consecutive episodes of central cyanosis and tetany of the limbs with spontaneous recovery the same afternoon. The child was also very irritable, regurgitated a lot, and positioned himself in opisthotonos. Between these episodes, the neurological exam showed some perturbations (horizontal nystagmus and Bell's phenomenon, hypertony of the extensor muscles, and mild hypotony of the axial flexor muscles) with slow improvement over the following hours. The remaining clinical exam, the laboratory work (complete blood count, renal, hepatic, and muscular tests, capillary blood gas, plasmatic amino acids, and urinary organic acids), and the electroencephalogram findings were all normal. In the course of a detailed interview, the parents reported having given 3 bottles to their child, each one containing 200 mL of an infusion with 4 to 5 fruits of star anise, in the hours preceding the symptoms to relieve colic pains. The last seizure-like event took place approximately 8h after the last ingestion. We could prove the ingestion of anisatin, the toxic substance found in Japanese star anise, and the contamination of Chinese star anise by the Japanese species. Indeed, the anisatin analysis by liquid chromatography and mass spectroscopy (LC-MS) in a urine sample taken 22 h after the last infusion ingestion showed trace amounts of the substance. In another urine sample taken 33 h after ingestion, no anisatin could be detected. Furthermore, the analysis of the fruit sample gave an anisatin concentration of 7800 μg/kg while the maximum tolerance value in Switzerland is 1000 μg/kg. CONCLUSION: The evaluation of ALTE in infants should always include the possibility of intoxication. Star anise is generally considered a harmless medicine. Nevertheless, it can sometimes cause a severe intoxication resulting in various neurological and gastrointestinal symptoms. To prevent such events, not only the parents, but also the care personnel and pharmacists must be informed about the possible adverse effects caused either by the overdose of Chinese star anise or by the eventual contamination of herbal teas with Japanese star anise. A better control of the substances by the health authorities is also necessary.
Resumo:
We present a cross-sectional study that aims to describe the sociodemographic and clinical conditions of individuals with diabetes mellitus and to analyze their knowledge of treatment five years after the end of an educational program in which they took part. In 2010, 40 individuals who had participated in a diabetes educational program for 12 months in 2005 at a primary care service were interviewed. A form was used for data collection that included their knowledge of the notion, physiopathology, and treatment of the disease; exercise; nutrition; foot care; self-monitoring of capillary blood glucose at home; hypoglycemia; chronic complications; special situations; and family support. The results showed that the volunteers incorporated the information about the notion, physiopathology, and treatment of the disease; exercise; foot care; self-monitoring; care associated with hypoglycemia; chronic complications; and special situations. In contrast, nutrition and family support require further reinforcement. It is concluded that five years after the end of the educational program, the participants kept most of the information provided.
Resumo:
OBJECTIVE: Our aim was to evaluate a fluorescence-based enhanced-reality system to assess intestinal viability in a laparoscopic mesenteric ischemia model. MATERIALS AND METHODS: A small bowel loop was exposed, and 3 to 4 mesenteric vessels were clipped in 6 pigs. Indocyanine green (ICG) was administered intravenously 15 minutes later. The bowel was illuminated with an incoherent light source laparoscope (D-light-P, KarlStorz). The ICG fluorescence signal was analyzed with Ad Hoc imaging software (VR-RENDER), which provides a digital perfusion cartography that was superimposed to the intraoperative laparoscopic image [augmented reality (AR) synthesis]. Five regions of interest (ROIs) were marked under AR guidance (1, 2a-2b, 3a-3b corresponding to the ischemic, marginal, and vascularized zones, respectively). One hour later, capillary blood samples were obtained by puncturing the bowel serosa at the identified ROIs and lactates were measured using the EDGE analyzer. A surgical biopsy of each intestinal ROI was sent for mitochondrial respiratory rate assessment and for metabolites quantification. RESULTS: Mean capillary lactate levels were 3.98 (SD = 1.91) versus 1.05 (SD = 0.46) versus 0.74 (SD = 0.34) mmol/L at ROI 1 versus 2a-2b (P = 0.0001) versus 3a-3b (P = 0.0001), respectively. Mean maximal mitochondrial respiratory rate was 104.4 (±21.58) pmolO2/second/mg at the ROI 1 versus 191.1 ± 14.48 (2b, P = 0.03) versus 180.4 ± 16.71 (3a, P = 0.02) versus 199.2 ± 25.21 (3b, P = 0.02). Alanine, choline, ethanolamine, glucose, lactate, myoinositol, phosphocholine, sylloinositol, and valine showed statistically significant different concentrations between ischemic and nonischemic segments. CONCLUSIONS: Fluorescence-based AR may effectively detect the boundary between the ischemic and the vascularized zones in this experimental model.
Resumo:
Objectives: Our aim in this study was to determine the concentration of salivary glucose in healthy individuals and to compare it with the capillary glycemia. Study design: Samples of unstimulated whole saliva were collected from 63 non-diabetic patients. The concentration of salivary glucose and capillary blood was measured in all of the patients. The salivary glucose was determined by enzymatic method and spectrophotometry. The data was then analyzed using the Spearman correlation test, considering values of p<0.05 to be significant. Results: The whole sample consisted of 47.6% males and 52.4% women, with an average age of 37.5±15.7 years old. The average rates of unstimulated salivary flow were 0.41±0.21 ml/min among males and 0.31±0.15 ml/min among females. No significant difference was found based on these results (p=0.078). The average blood glucose among the males studied was 100.05±13.51 mg/dL, and among females, it was 99.5±13.9 mg/dL. The average salivary glucose for the whole sample was 5.97±1.87 mg/dL, with 5.91±2.19 mg/dL among males and 5.97±1.56 mg/dL among females, respectively, without presenting any significant differences (p=0.908). The concentration of salivary glucose did not present any statistically significant correlation with the capillary glycemia (p=0.732). Conclusions: The results suggest that the concentration of salivary glucose is not dependent on capillary glycemia and that the concentration of salivary glucose does not present significant differences between the measurements for males and females.
Resumo:
The aortic-pulmonary regions (APR) of seven adult marmosets (Callithrix jacchus) and the region of the right subclavian artery of a further three marmosets were diffusion-fixed with 10% buffered formol-saline solution. In both regions serial 5-µm sections were cut and stained by the Martius yellow, brilliant crystal scarlet and soluble blue method. Presumptive thoracic paraganglionic (PTP) tissue was only observed in the APR. PTP tissue was composed of small groups of cells that varied in size and number. The distribution of the groups of cells was extremely variable, so much so that it would be misleading to attempt to classify their position; they were not circumscribed by a connective tissue capsule, but were always related to the thoracic branches of the left vagus nerve. The cells lay in loose areolar tissue characteristic of this part of the mediastinum and received their blood supply from small adjacent connective tissue arterioles. Unlike the paraganglionic tissue found in the carotid body the cells in the thorax did not appear to have a profuse capillary blood supply. There was, however, a close cellular-neural relationship. The cells, 10-15 µm in diameter, were oval or rounded in appearance and possessed a central nucleus and clear cytoplasm. No evidence was found that these cells possessed a 'companion' cell reminiscent of the arrangement of type 1 and type 2 cells in the carotid body. In conclusion, we found evidence of presumed paraganglionic tissue in the APR of the marmoset which, however, did not show the characteristic histological features of the aortic body chemoreceptors that have been described in some non-primate mammals. A survey of the mediastina of other non-human primates is required to establish whether this finding is atypical for these animals.
Resumo:
Introducción: Después del ingreso de la monitoría fetal electrónica como estudio de bienestar fetal, se ha considerado por décadas que un aporte de carbohidratos a la gestante antes de la realización de la monitoría fetal influye en el reporte pero existen estudios que consideran que los niveles de glicemia materna no afecta la variabilidad de la monitoría fetal. Metodología: Se realizó un estudio de corte transversal, para evaluar el efecto de la glicemia materna en la monitoría fetal electrónica comparando los valores de glicemia materna con su resultado, según la categorización del ACOG. Las principales variables fueron las horas de ayuno, valores de glicemia, variabilidad de la monitoría fetal y presencia de aceleraciones. Resultados: Se incluyeron un total de 60 pacientes, que ingresaron al servicio de obstetricia y ginecología del Hospital Universitario Mayor Méderi en el periodo de estudio. No se encontraron diferencias estadísticamente significativas entre los resultados de monitoría fetal y los valores de glicemia materna. Ninguna paciente presentó monitoría categoría III (según categorización de la ACOG). Discusión Se requieren estudios analíticos más amplios para evaluar el papel de la glicemia en el resultado de la monitoría, pero el presente estudio sugiere que no existe relación entre la glicemia materna y el resultado de la monitoría fetal electrónica en la categorización del Colegio Americano De Ginecología Y Obstetricia (ACOG).
Resumo:
La butirilcolinesterasa humana (BChE; EC 3.1.1.8) es una enzima polimórfica sintetizada en el hígado y en el tejido adiposo, ampliamente distribuida en el organismo y encargada de hidrolizar algunos ésteres de colina como la procaína, ésteres alifáticos como el ácido acetilsalicílico, fármacos como la metilprednisolona, el mivacurium y la succinilcolina y drogas de uso y/o abuso como la heroína y la cocaína. Es codificada por el gen BCHE (OMIM 177400), habiéndose identificado más de 100 variantes, algunas no estudiadas plenamente, además de la forma más frecuente, llamada usual o silvestre. Diferentes polimorfismos del gen BCHE se han relacionado con la síntesis de enzimas con niveles variados de actividad catalítica. Las bases moleculares de algunas de esas variantes genéticas han sido reportadas, entre las que se encuentra las variantes Atípica (A), fluoruro-resistente del tipo 1 y 2 (F-1 y F-2), silente (S), Kalow (K), James (J) y Hammersmith (H). En este estudio, en un grupo de pacientes se aplicó el instrumento validado Lifetime Severity Index for Cocaine Use Disorder (LSI-C) para evaluar la gravedad del consumo de “cocaína” a lo largo de la vida. Además, se determinaron Polimorfismos de Nucleótido Simple (SNPs) en el gen BCHE conocidos como responsables de reacciones adversas en pacientes consumidores de “cocaína” mediante secuenciación del gen y se predijo el efecto delos SNPs sobre la función y la estructura de la proteína, mediante el uso de herramientas bio-informáticas. El instrumento LSI-C ofreció resultados en cuatro dimensiones: consumo a lo largo de la vida, consumo reciente, dependencia psicológica e intento de abandono del consumo. Los estudios de análisis molecular permitieron observar dos SNPs codificantes (cSNPs) no sinónimos en el 27.3% de la muestra, c.293A>G (p.Asp98Gly) y c.1699G>A (p.Ala567Thr), localizados en los exones 2 y 4, que corresponden, desde el punto de vista funcional, a la variante Atípica (A) [dbSNP: rs1799807] y a la variante Kalow (K) [dbSNP: rs1803274] de la enzima BChE, respectivamente. Los estudios de predicción In silico establecieron para el SNP p.Asp98Gly un carácter patogénico, mientras que para el SNP p.Ala567Thr, mostraron un comportamiento neutro. El análisis de los resultados permite proponer la existencia de una relación entre polimorfismos o variantes genéticas responsables de una baja actividad catalítica y/o baja concentración plasmática de la enzima BChE y algunas de las reacciones adversas ocurridas en pacientes consumidores de cocaína.
Resumo:
A dermatite atópica (DA) é um tema importante na dermatologia clínica. Na verdade, a patogénese dessa doença inflamatória crónica da pele, caracterizada principalmente por pele seca e prurido, ainda está longe de ser totalmente compreendida. A fim de saber mais acerca desta complexa doença, ratos Wistar machos e adultos (n = 10) foram utilizados como modelo animal, nos quais o tratamento com acetona (AA) foi comparado com o tratamento com água por 3 dias (AW). No dia 3, uma hora após o último tratamento, a AA mostrou maior perda transepidérmica de água (TEWL), fluxo sanguíneo capilar e reduzida hidratação quando comparada com AW. A análise comportamental mostrou que a acção de coçar foi marcadamente mais frequente no grupo AA (n = 5) quando comparado ao grupo AW (n = 5). Estes resultados justificam a implementação deste modelo animal como uma ferramenta experimental para investigação da AD.
Resumo:
The aim of the study was to test whether or not menstruating women’s levels of haemoglobin changed after three weeks consumption of Blutsaft. Previous studies on nutrition supplements including iron have shown increased haemoglobin levels. On Blutsaft, however, there are no studies carried out and published. The participants in this pilot study were menstruating women, with haemoglobin levels between 105 and 125 g/l at the initial part of the study. Haemoglobin concentrations were measured by capillary blood samples before and after three weeks recommended daily consumption of Blutsaft. Four participants completed the study and the result showed an increase in haemoglobin concentration of between 7 and 17 g/l., with a median value at 16,75 g/l. Despite the few participants who completed the study a significant increase in haemoglobin concentration, after the consumption of Blutsaft, can be determined.