888 resultados para breast silicone implants


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Capsular fibrosis is a severe complication after breast implantation with an uncertain etiology. Microbial colonization of the prosthesis is hypothesized as a possible reason for the low-grade infection and subsequent capsular fibrosis. Current diagnostic tests consist of intraoperative swabs and tissue biopsies. Sonication of removed implants may improve the diagnosis of implant infection by detachment of biofilms from the implant surface. METHODS: Breast implants removed from patients with Baker grades 3 and 4 capsular contracture were analyzed by sonication, and the resulting sonication fluid was quantitatively cultured. RESULTS: This study investigated 22 breast implants (6 implants with Baker 3 and 16 implants with Baker 4 capsular fibrosis) from 13 patients. The mean age of the patients was 49 years (range, 31-76 years). The mean implant indwelling time was 10.4 years (range, 3 months to 30 years). Of the 22 implants, 12 were used for breast reconstruction and 10 for aesthetic procedures. The implants were located subglandularly (n = 12), submuscularly (n = 6), and subcutaneously (n = 4). Coagulase-negative staphylococci, Propionibacterium acnes, or both were detected in the sonication fluid cultures of nine implants (41%), eight of which grew significant numbers of microorganisms (>100 colonies/ml of sonication fluid). CONCLUSIONS: Sonication detected bacteria in 41% of removed breast implants. The identified bacteria belonged to normal skin flora. Further investigation is needed to determine any causal relation between biofilms and capsular fibrosis.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Breast Implants Information for women considering breast implants The information in this booklet is being provided for women considering the option of breast implant surgery. The aim of the booklet is to assist women in making an informed choice about breast implants before opting for surgery. The information has been compiled by a subcommittee of the Advisory Committee for Medical Devices at the Irish Medicines Board and has included consultation with health professionals and representatives of interested organisations.  Download the PDF

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This leaflet is used to support the Northern Ireland breast screening programme and explains the procedure for women with breast implants

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: It has been hypothesized that bacterial biofilms on breast implants may cause chronic inflammation leading to capsular contracture. The association between bacterial biofilms of removed implants and capsular contracture was investigated. METHODS: Breast implants explanted between 2006 and 2010 at five participating centres for plastic and reconstructive surgery were investigated by sonication. Bacterial cultures derived from sonication were correlated with patient, surgical and implant characteristics, and the degree of capsular contracture. RESULTS: The study included 121 breast implants from 84 patients, of which 119 originated from women and two from men undergoing gender reassignment. Some 50 breast prostheses were implanted for reconstruction, 48 for aesthetic reasons and 23 implants were used as temporary expander devices. The median indwelling time was 4·0 (range 0·1-32) years for permanent implants and 3 (range 1-6) months for temporary devices. Excluding nine implants with clinical signs of infection, sonication cultures were positive in 40 (45 per cent) of 89 permanent implants and in 12 (52 per cent) of 23 temporary devices. Analysis of permanent implants showed that a positive bacterial culture after sonication correlated with the degree of capsular contracture: Baker I, two of 11 implants; Baker II, two of ten; Baker III, nine of 23; and Baker IV, 27 of 45 (P < 0·001). The most frequent organisms were Propionibacterium acnes (25 implants) and coagulase-negative staphylococci (21). CONCLUSION: Sonication cultures correlated with the degree of capsular contracture, indicating the potential causative role of bacterial biofilms in the pathogenesis of capsular contracture. Registration number: NCT01138891 (http://www.clinicaltrials.gov).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Silicone breast implants are used to a wide extent in the field of plastic surgery. However, capsular contracture remains a considerable concern. This study aimed to analyze the effectiveness and applicability of an ultracision knife for capsulectomy breast surgery. METHODS: A prospective, single-center, randomized study was performed in 2009. The inclusion criteria specified female patients 20-80 years of age with capsular contracture (Baker 3-4). Ventral capsulectomy was performed using an ultracision knife on one side and the conventional Metzenbaum-type scissors and surgical knife on the collateral side of the breast. Measurements of the resected capsular ventral fragment, operative time, remaining breast tissue, drainage time, seroma and hematoma formation, visual analog scale pain score, and sensory function of the nipple-areola complex were assessed. In addition, histologic analysis of the resected capsule was performed. RESULTS: Five patients (median age, 59.2 years) were included in this study with a mean follow-up period of 6 months. Three patients had Baker grade 3 capsular contracture, and two patients had Baker grade 4 capsular contracture. The ultracision knife was associated with a significantly lower pain score, shorter operative time, smaller drainage volume, and shorter drainage time and resulted in a larger amount of remaining breast tissue. Histologic analysis of the resected capsule showed no apoptotic cells in the study group or control group. CONCLUSIONS: The results suggest that ventral capsulectomy with Baker grade 3 or 4 contracture using the ultracision knife is feasible, safe, and more efficient than blunt dissection and monopolar cutting diathermy and has a short learning curve. LEVEL OF EVIDENCE II: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/00266 .

Relevância:

40.00% 40.00%

Publicador:

Resumo:

New injectable fillers such as hyaluronic acid have recently been employed as a non-surgical alternative to implants such as silicone for aesthetic breast enhancement. Although their utilization is not yet widespread in Brazil, radiologists should be aware of the imaging findings in this context and of the implications of the presence of this filler for the radiological evaluation in the screening for breast cancer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: ALK-negative anaplastic large cell lymphoma associated with breast implant (i-ALCL) has been recently recognized as a distinct entity. Among 43 830 lymphomas registered in the French Lymphopath network since 2010, 300 breast lymphomas comprising 25 peripheral T-cell lymphomas (PTCL) were reviewed. Among PTCL, ALK-negative ALCL was the most frequent and all of them were associated with breast implants. PATIENTS AND METHODS: Since 2010, all i-ALCL cases were collected from different institutions through Lymphopath. Immuno-morphologic features, molecular data and clinical outcome of 19 i-ALCLs have been retrospectively analyzed. RESULTS: The median age of the patients was 61 years and the median length between breast implant and i-ALCL was 9 years. Most implants were silicone-filled and textured. Implant removal was performed in 17 out of 19 patients with additional treatment based on mostly CHOP or CHOP-like chemotherapy regimens (n = 10/19) or irradiation (n = 1/19). CHOP alone or ABVD following radiation without implant removal have been given in two patients. The two clinical presentations, i.e. effusion and less frequently tumor mass correlated with distinct histopathologic features: in situ i-ALCL (anaplastic cell proliferation confined to the fibrous capsule) and infiltrative i-ALCL (pleomorphic cells massively infiltrating adjacent tissue with eosinophils and sometimes Reed-Sternberg-like cells mimicking Hodgkin lymphoma). Malignant cells were CD30-positive, showed a variable staining for EMA and were ALK negative. Most cases had a cytotoxic T-cell immunophenotype with variable T-cell antigen loss and pSTAT3 nuclear expression. T-cell receptor genes were clonally rearranged in 13 out of 13 tested cases. After 18 months of median follow-up, the 2-year overall survival for in situ and infiltrative i-ALCL was 100% and 52.5%, respectively. CONCLUSIONS: In situ i-ALCLs have an indolent clinical course and generally remain free of disease after implant removal. However, infiltrative i-ALCLs could have a more aggressive clinical course that might require additional therapy to implant removal.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Os implantes mamários de silicone têm sido empregados, tanto nas cirurgias de aumento das mamas, quanto na reconstrução do tecido mamário após mastectomia. A segurança biológica dos implantes de silicone merece estudo relacionado aos processos de esterilização empregados, pois podem constituir-se em fator de comprometimento da estrutura química do polímero e, conseqüentemente, da biocompatibilidade. Este estudo consistiu na avaliação da biocompatibilidade de implantes mamários de silicone após terem sido submetidos aos processos de esterilização por calor seco, radiação gama e óxido de etileno. O parâmetro avaliado foi a viabilidade celular, empregando o método de difusão em agar e de captura do vermelho neutro. As amostras compreenderam implantes de silicone gel lisos, texturizados e revestidos com poliuretano e implantes texturizados pré-cheios com solução salina. Também foi realizado o teste de endotoxinas bacterianas pelo método do LAL e determinação da taxa de migração do gel de silicone (teste de bleed). Os três métodos de esterilização mostraram-se igualmente eficientes pela comprovação da condição de esterilidade dos implantes através de metodologia descrita na Farmacopéia Americana 27 edição. Os níveis de endotoxinas bacterianas dos implantes, também atenderam aos requisitos dos compêndios oficiais. Na avaliação da biocompatibilidade todos os implantes, independente dos processos de esterilização utilizados, apresentaram ausência de citotoxicidade. Os resultados do teste de bleed mostraram uma maior taxa de migração de gel para os implantes de superfície lisa em comparação com os implantes de superfície texturizada e revestida com poliuretano, quando esterilizados por calor seco. Ao comparar a taxa de migração do gel para os implantes de superfície lisa esterilizados por calor seco e óxido de etileno, obteve-se uma maior taxa de migração para aqueles implantes esterilizados por óxido de etileno. As diferentes avaliações realizadas neste estudo abrangeram aspectos biológicos, químicos e físicos relevantes para garantir um produto de boa qualidade e que, por assegurar a manutenção da característica de biocompatibilidade, resulta na segurança biológica deste tipo de implante.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. The radioguided localization of occult breast lesions (ROLL) technique often utilizes iodinated radiographic contrast to assure that the local injection of (99m)Tc-MAA corresponds to the location of the lesion under investigation. However, for this application, this contrast has several shortcomings. The objective of this study was to evaluate the safety, effectiveness and technical feasibility of the use of polydimethylsiloxane (PDMS) as radiological contrast and tissue marker in ROLL. Materials and methods. The safety assessment was performed by the acute toxicity study in Wistar rats (n = 50). The radiological analysis of breast tissue (n = 32) from patients undergoing reductive mammoplasty was used to verify the effectiveness of PDMS as contrast media. The technical feasibility was evaluated through the scintigraphic and histologic analysis. Results. We found no toxic effects of PDMS for this use during the observational period. It has been demonstrated in human breast tissue that the average diameter of the tissue marked by PDMS was lower than when marked by the contrast medium (p <0.001). PDMS did not interfere with the scintigraphic uptake (p = 0.528) and there was no injury in histological processing of samples. Conclusions. This study demonstrated not only the superiority of PDMS as radiological contrast in relation to the iodinated contrast, but also the technical feasibility for the same applicability in the ROLL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

CYR61 (Cysteine-rich angiogenic inducer 61) is a matricellular protein that regulates cell proliferation, adhesion, migration and cell survival through interaction with various types of integrin cell adhesion receptors. At tissue level it is implicated in the regulation of embryonic development, wound healing and angiogenesis. CYR61 has also been involved in cancer progression, however its role appears to be diverse and complex depending on the cancer type and stage. Its contribution to metastasis formation is still unclear. Previous findings reported by our laboratory demonstrated that CYR61 cooperates with avßs integrin to promote invasion and metastasis of cancers growing in a pre-irradiated microenvironment. In this work, we used an orthotopic model of breast cancer to show for the first time that silencing of CYR61 in breast cancer cells suppresses lung metastasis formation. Silencing of MDA-MB-231 reduced both local growth and lung metastasis formation of tumor cells implanted in a pre-irradiated mammary fat pad. CYR61 silencing in tumors growing in non-irradiated mammary fat pads did not impact primary tumor growth but decreased lung metastasis formation. The effect of CYR61 on spontaneous lung metastasis formation during natural cancer progression was further examined by using an experimental model of metastasis. Results from these experiments indicate that CYR61 is critically involved in promoting cancer cells entry into lung parenchyma rather than later steps of colonization. In vitro experiments showed that CYR61 promotes tumor cell spreading, migration and transendothelial migration. CYR61 also supported colony formation under anchorage-independent condition and promotes resistance to anoikis through the involvement of ß1 and ß3 integrin. These results indicate that CYR61 promotes lung metastasis of breast cancer by facilitating extravasation into lung parenchyma through enhanced motility, transendothelial migration and resistance to anoikis. - CYR61 (Cysteine-rich angiogenic inducer 61) est une protéine matricellulaire qui régule la prolifération, l'adhérence, la migration et la survie des cellules par son interaction avec différents types de récepteurs d'adhésion cellulaire de la famille des intégrine. Au niveau des tissus, CYR61 est impliquée dans la régulation du développement embryonnaire, de la cicatrisation et de l'angiogenèse. CYR61 a également été impliquée dans le cancer, mais son rôle semble être divers et complexe en fonction du type du cancer et de son stade. Son rôle dans la formation des métastases n'est pas encore clair. Des résultats antérieurs rapportés par notre laboratoire ont montré que CYR61 coopère avec l'intégrine avß5 pour favoriser l'invasion et la métastase de tumeurs se développant dans un micro-environnement pré-irradié. Dans ce travail, nous avons utilisé un modèle orthotopique de cancer du sein pour démontrer pour la première fois que l'extinction (silencing) du gène CYR61 dans le cancer du sein réduit la formation de métastases pulmonaires. L'extinction de CYR61 dans la lignée cellulaire de cancer du sein humain MDA-MB- 231 réduit à la fois la croissance local ainsi que la formation de métastases pulmonaires à partir de cellules implantés dans les coussinets adipeux mammaires pré-irradié. L'extinction de CYR61 dans des tumeurs grandissant dans les coussinets adipeux mammaires non irradiées n'a pas d'incidence sur la croissance tumorale primaire mais réduit la formation des métastases pulmonaires. Par la suite nous avons examiné l'effet de CYR61 sur la formation de métastases pulmonaires en utilisant un modèle expérimental de métastase. Les résultats de ces expériences indiquent que CYR61 est impliquée de manière cruciale dans les étapes précoces de la formation de métastases, plutôt que dans les étapes tardives de colonisation du poumon. Des expériences in vitro ont montré que CYR61 favorise l'étalement, la migration et la transmigration endothéliale des cellules tumorales. CYR61 favorise également la formation de colonies dans des conditions indépendante de l'ancrage et la résistance à l'anoïkis par l'engagement des intégrines ß1 et ß3. Ces résultats indiquent que CYR61 favorise les métastases pulmonaires du cancer du sein en facilitant l'extravasation dans le parenchyme pulmonaire grâce à la stimulation de la motilità, de la migration transmigration endothéliale et de la résistance à l'anoïkis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.