983 resultados para body measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Fat-free mass (FFM) reduction and the tendency for a reduction in surrounding fatty issue and increase in the middle are a natural consequence of growing old and should be studied in order to gain a better understanding of the aging process. This study set out to find the FFM differences between active elderly women in two age groups (60-69 and 70-80 years) and to determine which of the anthropometric measurements, body weight (BW), abdominal circumference (AC), or body mass index (BMI) are the best predictors of FFM variation within the group. Methods: Eighty-one (n = 81) active elderly women of the Third Age willingly signed up to participate in the research during the activities at the University of the Third Age (UTA) in Brazil. The research was approved by the Research Ethics Committee of the Faculty of Medical Sciences of the State University of Campinas (UNICAMP). Body weight (BW), height (H) and the BMI were measured according to the international standards. The AC was measured in centimetres at the H of the navel and body composition was ascertained using bioimpedance analysis. The SAS program was used to perform the statistical analysis of independent samples and parametric data. Results: The results showed FFM values with significant differences between the two groups, with the lowest values occurring among the women who were over 70 years of age. In the analysis, the Pearson`s Correlation Coefficient for each measured independent variable was ascertained, with the BW measurement showing the highest ratio (0.900). Conclusions: The BW measurement was regarded as reliable, low-cost and easy to use for monitoring FFM in elderly women who engage in physical activities. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bioelectrical impedance analysis (BIA) was used to assess body composition in rats fed on either standard laboratory diet or on a high-fat diet designed to induce obesity. Bioelectrical impedance analysis predictions of total body water and thus fat-free mass (FFM) for the group mean values were generally within 5% of the measured values by tritiated water ((H2O)-H-3) dilution. The limits of agreement for the procedure were, however, large, approximately +/-25%, limiting the applicability of the technique for measurement of body composition in individual animals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bioelectrical impedance analysis (BIA) offers the potential for a simple, portable and relatively inexpensive technique for the in vivo measurement of total body water (TBW). The potential of BIA as a technique of body composition analysis is even greater when one considers that body water can be used as a surrogate measure of lean body mass. However, BIA has not found universal acceptance even with the introduction of multi-frequency BIA (MFBIA) which, potentially, may improve the predictive accuracy of the measurement. There are a number of reasons for this lack of acceptance, although perhaps the major reason is that no single algorithm has been developed which can be applied to all subject groups. This may be due, in part, to the commonly used wrist-to-ankle protocol which is not indicated by the basic theory of bioimpedance, where the body is considered as five interconnecting cylinders. Several workers have suggested the use of segmental BIA measurements to provide a protocol more in keeping with basic theory. However, there are other difficulties associated with the application of BIA, such as effects of hydration and ion status, posture and fluid distribution. A further putative advantage of MFBIA is the independent assessment not only of TBW but also of the extracellular fluid volume (ECW), hence heralding the possibility of,being able to assess the fluid distribution between these compartments. Results of studies in this area have been, to date, mixed. Whereas strong relationships of impedance values at low frequencies with ECW, and at high frequencies with TBW, have been reported, changes in impedance are not always well correlated with changes in the size of the fluid compartments (assessed by alternative and more direct means) in pathological conditions. Furthermore, the theoretical advantages of Cole-Cole modelling over selected frequency prediction have not always been apparent. This review will consider the principles, methodology and applications of BIA. The principles and methodology will,be considered in relation to the basic theory of BIA and difficulties experienced in its application. The relative merits of single and multiple frequency BIA will be addressed, with particular attention to the latter's role in the assessment of compartmental fluid volumes. (C) 1998 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

New techniques in air-displacement plethysmography seem to have overcome many of the previous problems of poor reproducibility and validity. These have made body-density measurements available to a larger range of individuals, including children, elderly and sick patients who often have difficulties in being submerged underwater in hydrodensitometry systems. The BOD POD air-displacement system (BOD POD body composition system; Life Measurement Instruments, Concord, CA, USA) is more precise than hydrodensitometry, is simple and rapid to operate (approximately 1 min measurements) and the results agree closely with those of hydrodensitometry (e.g. +/-3.4% for estimation of body fat). Body line scanners employing the principles of three-dimensional photography are potentially able to measure the surface area and volume of the body and its segments even more rapidly (approximately 10 s), but the validity of the measurements needs to be established. Advances in i.r. spectroscopy and mathematical modelling for calculating the area under the curve have improved precision for measuring enrichment of (H2O)-H-2 in studies of water dilution (CV 0.1-0.9% within the range of 400-1000 mu l/l) in saliva, plasma and urine. The technique is rapid and compares closely with mass spectrometry (bias 1 (SD 2) %). Advances in bedside bioelectrical-impedance techniques are making possible potential measurements of skinfold thicknesses and limb muscle mass electronically. Preliminary results suggest that the electronic method is more reproducible (intra-and inter-individual reproducibility for measuring skinfold thicknesses) and associated with less bias (+ 12%), than anthropometry (+ 40%). In addition to these selected examples, the 'mobility' or transfer of reference methods between centres has made the distinction between reference and bedside or field techniques less distinct than in the past.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present study was to evaluate the performance of a new bioelectrical impedance instrument, the Soft Tissue Analyzer (STA), which predicts a subject's body composition. A cross-sectional population study in which the impedance of 205 healthy adult subjects was measured using the STA. Extracellular water (ECW) volume (as a percentage of total body water, TBW) and fat-free mass (FFM) were predicted by both the STA and a compartmental model, and compared according to correlation and limits of agreement analysis, with the equivalent data obtained by independent reference methods of measurement (TBW measured by D2O dilution, and FFM measured by dual-energy X-ray absorptiometry). There was a small (2.0 kg) but significant (P < 0.02) difference in mean FFM predicted by the STA, compared with the reference technique in the males, but not in the females (-0.4 kg) or in the combined group (0.8 kg). Both methods were highly correlated. Similarly, small but significant differences for predicted mean ECW volume were observed. The limits of agreement for FFM and ECW were -7.5-9.9 and -4.1-3.0 kg, respectively. Both FFM and ECW (as a percentage of TBW) are well predicted by the STA on a population basis, but the magnitude of the limits of agreement with reference methods may preclude its usefulness for predicting body composition in an individual. In addition, the theoretical basis of an impedance method that does not include a measure of conductor length requires further validation. (C) Elsevier Science Inc. 2000.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background & aims: Severe obesity imposes physical limitations to body composition assessment. Our aim was to compare body fat (BF) estimations of severely obese patients obtained by bioelectrical impedance (BIA) and air displacement plethysmography (ADP) for development of new equations for BF prediction. Methods: Severely obese subjects (83 female/36 mate, mean age = 41.6 +/- 11.6 years) had BF estimated by BIA and ADP. The agreement of the data was evaluated using Bland-Altman`s graphic and concordance correlation coefficient (CCC). A multivariate regression analysis was performed to develop and validate new predictive equations. Results: BF estimations from BIA (64.8 +/- 15 kg) and ADP (65.6 +/- 16.4 kg) did not differ (p > 0.05, with good accuracy, precision, and CCC), but the Bland- Altman graphic showed a wide Limit of agreement (- 10.4; 8.8). The standard BIA equation overestimated BF in women (-1.3 kg) and underestimated BF in men (5.6 kg; p < 0.05). Two BF new predictive equations were generated after BIA measurement, which predicted BF with higher accuracy, precision, CCC, and limits of agreement than the standard BIA equation. Conclusions: Standard BIA equations were inadequate for estimating BF in severely obese patients. Equations developed especially for this population provide more accurate BF assessment. (C) 2008 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Several studies have shown that liquid and food intake interfere with the evaluation of body composition in adults. However, since there are no reports about this interference in the elderly population, the need to fast for this evaluation may be dispensable. Objectives: The objective of the present study was to assess the influence of liquid and solid food on the measurement of body composition by bioelectrical impedance analysis (BIA) and by dual energy X-ray absorptiometry (DXA). Design: Forty-one male volunteers aged 62 to 87 years participated in the study. The subjects were submitted to evaluation of body composition by DXA and BIA under fasting conditions and 1 hour after the ingestion of breakfast (500 ml of orange juice and one 50 g bread roll with butter). Results: There was no significant difference in the variables fat-free mass (FFM) or fat mass (FM) between the fasting condition and the evaluation performed 1 hour after the meal as measured by BIA or DXA. There was also no significant difference when the same variables were compared between methods. Conclusion: In the present study, the ingestion of 500 ml orange juice and of one bread roll with butter by elderly subjects did not affect the results of the parameters of body composition determined by BIA or DXA. Thus, these exams could be performed without the rigor of fasting, often poorly tolerated by the elderly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prevention and treatment of diseases related to changes in body composition require accurate methods for the measurement of body composition. However, few studies have dealt specifically with the assessment of body composition of undernourished older subjects by different methodologies. To assess the body composition of undernourished older subjects by two different methods, dual energy x-ray absorptiometry (DXA) and bioelectric impedance (BIA), and to compare results with those of an eutrophic group. The study model was cross-sectional; the study was performed at the University Hospital of the School of Medicine of Ribeiro Preto, University of So Paulo, Brazil. Forty-one male volunteers aged 62 to 91 years. The groups were selected on the basis of anamnesis, physical examination and nutritional assessment according to the Mini Nutritional Assessment (MNA) score. Body composition was assessed by DXA and BIA. Body weight, arm and calf circumference, body mass index (BMI), fat free mass (FFM) and fat mass (FM) were significantly lower in the undernourished group as compared to the eutrophic group. There were no significant differences between FFM and FM mean values determined by DXA and BIA in both groups, but the agreement between methods in the undernourished group was less strong. Our results suggest caution when BIA is to be applied in studies including undernourished older subjects. This study does not support BIA as an accurate method for the individual assessment of body composition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The major stress response to critical illness leads to a catabolic state and loss of lean body mass. Aims: To test whether an increased rate of creatinine excretion might provide unique and timely information to monitor cell catabolism; to relate this information to balances of cell constituents (nitrogen, potassium, phosphate and magnesium); to evaluate the effectiveness of nutritional therapy to reverse this catabolic process. Design: Prospective observational study. Methods: Children with severe traumatic brain injury admitted to the paediatric critical care units of The Hospital for Sick Children, Toronto, Canada and Hospital das Clnicas, Faculty of Medicine of Ribeiro Preto, University of So Paulo, Brazil were studied. Complete 24 h urine collections were obtained for measurement of creatinine excretion rate and daily balances of nitrogen, potassium, phosphate and magnesium. Results: Seventeen patients were studied for 310 days. On Day 1, all had negative balances for protein and phosphate. Balances for these intracellular constituents became positive when protein intake was >= 1 g/kg/day and energy intake was >= 50% of estimated energy expenditure (P < 0.0001). Creatinine excretion rate was positively correlated with the urea appearance rate (r = 0.60; P < 0.0001), and negatively with protein balance (r = -0.45; P < 0.0001). Sepsis developed in four patients; before its clinical detection, there were negative balances for all intracellular markers and an abrupt rise in the excretion of creatinine. Conclusions: Negative balances of intracellular components and an increase in rate of creatinine excretion heralded the onset of catabolism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to determine the relationship among body weight (BW), body condition score (BCS) and rump fat thickness (RFAT) measured by ultrasonography, and validate the relationship between BCS and RFAT over the time. Two hundred sixty and six Nelore cows had their BW, BCS and RFAT evaluated at five different moments during the production cycle: M1) weaning: M2) parturition, M3) 42 days post-partum; M4) 82 days postpartum and M5) 112 days post-partum. A BCS value was attributed for each cow following a I to 5 points scale. Ultrasonographic images for RFAT measurement were obtained using a 3.5 MHz linear transducer. Images were immediately analyzed as soon as they were formed and frozen. Body condition scores and ultrasound measurements were collected on the same day by a single trained technician. The relationship between BCS and RFAT values was investigated by regression models. The analysis of similarity among the five obtained models was performed using the proc MIXED from SAS and the correlations among variables were analyzed with proc CORR from SAS. The BCS was able to predict RFAT in Nelore cows in all different moments evaluated. Also, it was shown that BCS presented high correlation (r=0.82 to 0.93) and relationship (R(2) = 0.73 to 0.92) with RFAT. However, both BCS and RFAT showed low correlation (r=0.37 to 0.50) and relationship (R(2) = 0.13 to 0.25) with BW. The BCS classification by visual method using a 1 to 5 point scale, was able to predict the RFAT in Nelore cows over the time. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poor nutritional status in patients with cystic fibrosis (CF) is associated with severe lung disease, and possible causative factors include inadequate intake, malabsorption, and increased energy requirements. Body cell mass (which can be quantified by measurement of total body potassium) provides an ideal standard for measurements of energy expenditure. The aim of this study was to compare resting energy expenditure (REE) in patients with CF with both predicted values and age-matched healthy children and to determine whether REE was related to either nutritional status or pulmonary function. REE was measured by indirect calorimetry and body cell mass by scanning with total body potassium in 30 patients with CF(12 male, mean age = 13.07 +/- 0.55 y) and 18 healthy children (six male, mean age = 12.56 +/- 1.25 y). Nutritional status was expressed as a percentage of predicted total body potassium; Lung function was measured in the CF group by spirometry and expressed as the percentage of predicted forced expiratory volume in 1 s. Mean REE was significantly increased in the patients with CF compared with healthy children (119.3 +/- 3.1% predicted versus 103.6 +/- 5% predicted, P < 0.001) and, using multiple regression techniques, REE for total body potassium was significantly increased in patients with CF (P = 0.0001). There was no relation between REE and nutritional status or pulmonary disease status in the CF group. In conclusion, REE is increased in children and adolescents with CF but is not directly related to nutritional status or pulmonary disease. Nutrition 2001;17:22-25. (C)Elsevier Science Inc. 2001.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The association of sustained cerebral edema with poor neurological outcome following hypoxia-ischaemia in the neonate suggests that measurement of cerebral edema may allow early prediction of outcome in these infants. Direct measurements of cerebral impedance have been widely used in animal studies to monitor cerebral edema, but such invasive measurements are not possible in the human neonate. This study investigated the ability of noninvasive cerebral impedance measurements to detect cerebral edema following hypoxia-ischaemia. One-day-old piglets were anaesthetized, intubated and ventilated. Hypoxia was induced by reducing the inspired oxygen concentration to 4-6% O-2. Noninvasive cerebral bioimpedance was measured using gel electrodes attached to the scalp. Cerebral bioimpedance was also measured directly by insertion of two silver-silver chloride electrodes subdurally. Noninvasive and invasive measurements were made before, during and after hypoxia. Whole body impedance was measured to assess overall fluid movements. Intracranial pressure was measured continuously via a catheter inserted subdurally, as an index of cerebral edema. There was good agreement between noninvasive and invasive measurements of cerebral impedance although externally obtained responses were attenuated. Noninvasive measurements were also well correlated with intracranial pressure. Whole body impedance changes did not account for increases in noninvasively measured cerebral impedance. Results suggest that noninvasive cerebral impedance measurements do reflect intracranial events, and are able to detect cerebral edema following hypoxia-ischaemia in the neonate. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An improved HPLC method has been established for the measurement of harderoporphyrin (HP) in the harderian gland of rats and mice. Groups of female Wistar rats were given a single oral dose of sodium arsenite at 0, 0.5 or 5.0 mg As(III)/kg body weight, or a slurry of arsenic-contaminated soil at equivalent dose rates and the animals were sacrificed 96 h after dosing. A group of C57BL/6J female mice were chronically exposed to drinking water containing 500 mug As(V)/I of sodium arsenate ad libitum for over 2 years. Porphyrins were measured in the harderian glands of rats and mice. Our results suggest that HP and the alteration of the porphyrin profile in the harderian glands of rodents is a highly sensitive biomarker for both single sub-lethal and chronic arsenic exposure. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on the motor and functional outcomes of 20 children with developmental coordination disorder (DCD) aged 4-8 years consecutively referred to a pediatric physiotherapy service. Children with a Movement ABC (M-ABC) score less than the 15th percentile, and with no concurrent medical, sensory, physical, intellectual or neurological impairments, were recruited. The Motor Assessment Outcomes Model (MAOM) [Coster and Haley, Infants and Young Children 4 (1992) 11] provided the theoretical base for measurement selection, and preliminary findings at the activities and participation levels of the model are reported in this article. Children with DCD performed at the lower end of the normal range on the Pea-body Developmental Motor Scales (fine motor total score) (M = 85.65, SD = 12.23). Performance on the Visual Motor Integration Test (VMI) standard scores was within the average range (M = 96.15, SD = 10.69). Videotaped observations of the children's writing and cutting indicated that 29% were left-handed and that a large proportion of all children (31%) utilized unusual pencil grasp patterns and immature prehension of scissors. Measurement at the participation level involved use of the Pictorial Scale of Perceived Competence and Social Acceptance (PCSA) and Pediatric Evaluation of Disability Inventory (PEDI). Overall, these young children rated themselves towards the more competent and accepted end of the PCSA over the dimensions of physical and cognitive competence and peer and maternal acceptance. The PEDI revealed generally average performance on social (M = 49.98, SD = 16.62) and mobility function (M = 54.71, SD = 3.99), however, self-care function was below the average range for age (M = 38.01, SD = 12.19). The utility of the MAOM as a framework for comprehensive measurement of functional and motor outcomes of DCD in young children is discussed. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare the measurement of total body water (TBW) by deuterium ((H2O)-H-2) dilution and bioelectrical impedance analysis (BIA) in patients with cystic fibrosis (CF) and healthy controls. Thirty-six clinically stable patients with CF (age 25.4 +/- 5.6 yrs) and 42 healthy controls (age 25.4 +/- 4.8) were recruited into this study. TBW was measured by (H2O)-H-2 dilution and predicted by BIA in patients and controls. The TBW predicted from BIA was significantly different from TBW as measured using (H2O)-H-2 in patients (P