782 resultados para Walking tests


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To shed light on the potential efficacy of cycling as a resting modality in the treatment of intermittent claudication (IC), this study compared physiological and symptomatic responses to graded walking and cycling tests in claudicants. Sixteen subjects with peripheral arterial disease (resting ankle:brachial index (ABI) < 0.9) and IC completed a maximal graded treadmill walking (T) and cycle (C) Lest after three familiarization tests on each mode. During cacti test, symptoms, oxygen uptake (VO2), minute ventilation (V-E), (respiratory exchange ratio) (RER) and heart rate (HR) were measured, and for 10 min after each Lest the brachial and ankle systolic pressures were recorded, All but One subject experienced calf pain as the primary limiting symptom during T whereas the symptoms were more varied during C and included thigh pain, calf pain and dyspnoea, Although maximal exercise time was significantly longer on C than T (690 +/- 67 vs, 495 +/- 57 s), peak VO2, peak, V-E and peak heart rate during C and T were not different; whereas peak RER was higher during C. These responses during C and T were also positively 1, (P < 0.05) with each other, with the exception of RER. The postexercise systolic pressures were also not different between C and T. However, the peak decline ill ankle pressures from resting values after C and T were not correlated with each other. Thew data demonstrate that cycling and walking induce a similar level of metabolic and cardiovascular strain, but that the primary limiting symptoms and haemodynamic response in an individual's extremity, measured after exercise, can differ substantially between these two modes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background: The Walking Estimated-Limitation Calculated by History (WELCH) questionnaire has been proposed to evaluate walking impairment in patients with intermittent claudication (IC), presenting satisfactory psychometric properties. However, a Brazilian Portuguese version of the questionnaire is unavailable, limiting its application in Brazilian patients. Objective: To analyze the psychometric properties of a translated Brazilian Portuguese version of the WELCH in Brazilian patients with IC. Methods: Eighty-four patients with IC participated in the study. After translation and back-translation, carried out by two independent translators, the concurrent validity of the WELCH was analyzed by correlating the questionnaire scores with the walking capacity assessed with the Gardner treadmill test. To determine the reliability of the WELCH, internal consistency and test–retest reliability with a seven-day interval between the two questionnaire applications were calculated. Results: There were significant correlations between the WELCH score and the claudication onset distance (r = 0.64, p = 0.01) and total walking distance (r = 0.61, p = 0.01). The internal consistency was 0.84 and the intraclass correlation coefficient between questionnaire evaluations was 0.84. There were no differences in WELCH scores between the two questionnaire applications. Conclusion: The Brazilian Portuguese version of the WELCH presents adequate validity and reliability indicators, which support its application to Brazilian patients with IC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate whether an activity monitor based on body acceleration measurement can accurately assess the energy cost of the human locomotion, 12 subjects walked a combination of three different speeds (preferred speed +/- 1 km/h) and seven slopes (-15 to +15% by steps of 5%) on a treadmill. Body accelerations were recorded using a triaxial accelerometer attached to the low back. The mean of the integral of the vector magnitude (norm) of the accelerations (mIAN) was calculated. VO2 was measured using continuous indirect calorimetry. When the results were separately analysed for each incline, mIAN was correlated to VO2 (average r = 0.87, p<0.001, n = 36). VO2 was not significantly correlated to mIAN when data were globally analysed (n = 252). Large relative errors occurred when predicted VO2 (estimated from data of level walking) was compared with measured VO2 for different inclines (-53% at +15% incline, to +55% at -15% incline). It is concluded that without an external measurement of the slope, the standard method of analysis of body accelerations cannot accurately predict the energy cost of uphill or downhill walking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Interventions designed to increase workplace physical activity may not automatically reduce high volumes of sitting, a behaviour independently linked to chronic diseases such as obesity and type II diabetes. This study compared the impact two different walking strategies had on step counts and reported sitting times. Methods: Participants were white-collar university employees (n = 179; age 41.3 ± 10.1 years; 141 women), who volunteered and undertook a standardised ten-week intervention at three sites. Preintervention step counts (Yamax SW-200) and self-reported sitting times were measured over five consecutive workdays. Using pre-intervention step counts, employees at each site were randomly allocated to a control group (n = 60; maintain normal behaviour), a route-based walking group (n = 60; at least 10 minutes sustained walking each workday) or an incidental walking group (n = 59; walking in workday tasks). Workday step counts and reported sitting times were re-assessed at the beginning, mid- and endpoint of intervention and group mean± SD steps/day and reported sitting times for pre-intervention and intervention measurement points compared using a mixed factorial ANOVA; paired sample-t-tests were used for follow-up, simple effect analyses. Results: A significant interactive effect (F = 3.5; p < 0.003) was found between group and step counts. Daily steps for controls decreased over the intervention period (-391 steps/day) and increased for route (968 steps/day; t = 3.9, p < 0.000) and incidental (699 steps/day; t = 2.5, p < 0.014) groups. There were no significant changes for reported sitting times, but average values did decrease relative to the control (routes group = 7 minutes/day; incidental group = 15 minutes/day). Reductions were most evident for the incidental group in the first week of intervention, where reported sitting decreased by an average of 21 minutes/day (t = 1.9; p < 0.057). Conclusion: Compared to controls, both route and incidental walking increased physical activity in white-collar employees. Our data suggests that workplace walking, particularly through incidental movement, also has the potential to decrease employee sitting times, but there is a need for on-going research using concurrent and objective measures of sitting, standing and walking.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To investigate if a home environment test battery can be used to measure effects of Parkinson’s disease (PD) treatment intervention and disease progression. Background Seventy-seven patients diagnosed with advanced PD were recruited in an open longitudinal 36-month study at 10 clinics in Sweden and Norway; 40 of them were treated with levodopa-carbidopa intestinal gel (LCIG) and 37 patients were candidates for switching from oral PD treatment to LCIG. They utilized a mobile device test battery, consisting of self-assessments of symptoms and objective measures of motor function through a set of fine motor tests (tapping and spiral drawings), in their homes. Both the LCIG-naïve and LCIG-non-naïve patients used the test battery four times per day during week-long test periods. Methods Assessments The LCIG-naïve patients used the test battery at baseline (before LCIG), month 0 (first visit; at least 3 months after intraduodenal LCIG), and thereafter quarterly for the first year and biannually for the second and third years. The LCIG-non-naïve patients used the test battery from the first visit, i.e. month 0. Out of the 77 patients, only 65 utilized the test battery; 35 were LCIG-non-naïve and 30 LCIG-naïve. In 20 of the LCIG-naïve patients, assessments with the test battery were available during oral treatment and at least one test period after having started infusion treatment. Three LCIG-naïve patients did not use the test battery at baseline but had at least one test period of assessments thereafter. Hence, n=23 in the LCIG-naïve group. In total, symptom assessments in the full sample (including both patient groups) were collected during 379 test periods and 10079 test occasions. For 369 of these test periods, clinical assessments including UPDRS and PDQ-39 were performed in afternoons at the start of the test periods. The repeated measurements of the test battery were processed and summarized into scores representing patients’ symptom severities over a test period, using statistical methods. Six conceptual dimensions were defined; four subjectively-reported: ‘walking’, ‘satisfied’, ‘dyskinesia’, and ‘off’ and two objectively-measured: ‘tapping’ and ‘spiral’. In addition, an ‘overall test score’ (OTS) was defined to represent the global health condition of the patient during a test period. Statistical methods Change in the test battery scores over time, that is at baseline and follow-up test periods, was assessed with linear mixed-effects models with patient ID as a random effect and test period as a fixed effect of interest. The within-patient variability of OTS was assessed using intra-class correlation coefficient (ICC), for the two patient groups. Correlations between clinical rating scores and test battery scores were assessed using Spearman’s rank correlations (rho). Results In LCIG-naïve patients, mean OTS compared to baseline was significantly improved from the first test period on LCIG treatment until month 24. However, there were no significant changes in mean OTS scores of LCIG-non-naïve patients, except for worse mean OTS at month 36 (p<0.01, n=16). The mean scores of all subjectively-reported dimensions improved significantly throughout the course of the study, except ‘walking’ at month 36 (p=0.41, n=4). However, there were no significant differences in mean scores of objectively-measured dimensions between baseline and other test periods, except improved ‘tapping’ at month 6 and month 36, and ‘spiral’ at month 3 (p<0.05). The LCIG-naïve patients had a higher within-subject variability in their OTS scores (ICC=0.67) compared to LCIG-non-naïve patients (ICC=0.71). The OTS correlated adequately with total UPDRS (rho=0.59) and total PDQ-39 (rho=0.59). Conclusions In this 3-year follow-up study of advanced PD patients treated with LCIG we found that it is possible to monitor PD progression over time using a home environment test battery. The significant improvements in the mean OTS scores indicate that the test battery is able to measure functional improvement with LCIG sustained over at least 24 months.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The reproducibility of the 6-min walking test (6MWT) needs to be more solidly studied. This study aimed to investigate the reproducibility of two 6MWTs performed on subsequent days in a large and representative sample of patients with chronic obstructive pulmonary disease (COPD), and to quantify the learning effect between the two tests, as well as its determinants.In a retrospective observational study, 1,514 patients with COPD performed two 6MWTs on subsequent days. Other measurements included body composition (dual X-ray absorptiometry), dyspnoea (Medical Research Council scale) and comorbidity (Charlson index).Although the 6MWT was reproducible (intraclass correlation coefficient=0.93), patients walked farther in the second test (391 m, 95% CI 155-585 m versus 418 m, 95% CI 185-605 m; p < 0.0001). on average, the second 6MWT increased by 27 m (or 7%), and 82% of patients improved in the second test. Determinants of improvement >= 42 m in the second test (upper limit of the clinically important change) were as follows: first 6MWT < 350 m, Charlson index < 2 and body mass index < 30 kg.m(-2) (OR 2.49, 0.76 and 0.60, respectively).The 6MWT was statistically reproducible in a representative sample of patients with COPD. However, the vast majority of patients improved significantly in the second test by an average learning effect of 27 m.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to investigate the effects of an imposed external auditory constraint upon the temporal organization of walking. Ten subjects were videotaped walking normally (N) and with instructions to couple naturally, at mid-swing, or at toe-off to a metronome beat. Based upon an analysis of variance and post hoc Scheffe tests most temporal variables were not significantly different among conditions. The duration of swing phase was significantly different between natural coupling and toe-off. The deviation from the metronome beat was significantly different between the natural coupling and both mid-swing and toe-off. Subjects generally were not successful in achieving coupling during the latter conditions. Thigh and shank phase portraits were used to describe the system's organization to the external constraint.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. Fatigue has been pointed as a fall risk in the elderly; however, the effects of prolonged gait on neuromuscular recruitment and on its pattern remain unknown. The aim of this study was to evaluate the effects of prolonged gait on neuromuscular recruitment levels and spatial-temporal gait variables. Methods. Eight healthy older women (age: 72.63 ± 6.55 years) walked at their preferred walking speed for twenty minutes on a treadmill. The Root Mean Square (RMS) from the vastus-lateralis, femoral biceps, tibialis anterior and lateral gastrocnemius muscles were determined at the first and last minute of the test during the moments of Heel Strike (HS), Terminal Stance and Terminal Swing (TS). In addition, coactivation in the knee and ankle as well as the stride cadence and length were measured in the test. The two RMS data (taken at the first and last minute) were compared by means of a Student's t-test. Results. Twenty minutes of walking induced fatigue in the subjects, as observed through an increase in RMS, notably during the HS and TS. Coactivation was also influenced by the prolonged gait test. The only gait phase where a risk of falling was enhanced was the HS. Nonetheless, subjects developed strategies to maintain a safe motor pattern, which was evidenced by an increase in stride length and a decrease in stride cadence. Conclusion. Tests lasting just twenty minutes on a treadmill were enough to induce fatigue in older adults. However, the level of fatigue was not enough to present a danger or fall risk to elderly individuals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and objective: Field exercise tests have been increasingly used for pulmonary risk assessment. The 6-min walking distance (6MWD) is a field test commonly employed in clinical practice; however, there is limited evidence supporting its use as a risk assessment method in abdominal surgery. The aim was to assess if the 6MWD can predict the development of post-operative pulmonary complications (PPCs) in patients having upper abdominal surgery (UAS). Methods: This prospective cohort study included 137 consecutive subjects undergoing elective UAS. Subjects performed the 6MWD on the day prior to surgery, and their performance were compared with predicted values of 6MWD (p6MWD) using a previously validated formula. PPCs (including pneumonia, tracheobronchitis, atelectasis with clinical repercussions, bronchospasm and acute respiratory failure) were assessed daily by a pulmonologist blinded to the 6MWD results. 6MWD and p6MWD were compared between subjects who developed PPC (PPC group) and those who did not (no PPC group) using Student's t-test. Results: Ten subjects experienced PPC (7.2%) and no significant difference was observed between the 6MWD obtained in the PPC group and no PPC group (466.0 +/- 97.0 m vs 485.3 +/- 107.1 m; P = 0.57, respectively). There was also no significant difference observed between groups for the p6MWD (100.7 +/- 29.1% vs 90.6 -/+ 20.9%; P > 0.05). Conclusions: The results of the present study suggest that the 6-min walking test is not a useful tool to identify subjects with increased risk of developing PPC following UAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to use mechanical and photoelastic tests to compare the performance of cannulated screws with other fixation methods in mandibular symphysis fractures. Ten polyurethane mandibles were allocated to each group and fixed as follows: group PRP, 2 perpendicular miniplates; group PLL, 1 miniplate and 1 plate, parallel; and group CS, 2 cannulated screws. Vertical linear loading tests were performed. The differences between mean values were analyzed with the Tukey test. The photoelastic test was carried out using a polariscope. The results revealed differences between the CS and PRP groups at 1, 3, 5, and 10 millimeters of displacement. The photoelastic test confirmed higher stress concentration in all groups close to the mandibular base, whereas the CS group showed it throughout the region assessed. Conical cannulated screws performed well in mechanical and photoelastic tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the value of vaginal screening cytology after hysterectomy for benign disease. This cross-sectional study used cytology audit data from 2,512,039 screening tests in the metropolitan region of Campinas from 2000 to 2012; the object was to compare the prevalence of abnormal tests in women who had undergone a hysterectomy for benign diseases (n=53,891) to that of women who had had no hysterectomy. Prevalence ratios (95% confidence intervals, 95% CI) were determined, and chi-square analysis, modified by the Cochrane-Armitage test for trend, was used to investigate the effects of age. The prevalence of atypical squamous cells (ASC), low-grade squamous intraepithelial lesion (LSIL), and high-grade squamous intraepithelial lesion or squamous-cell carcinoma (HSIL/SCC) was 0.13%, 0.04% and 0.03%, respectively, in women who had undergone hysterectomy, and 0.93%, 0.51% and 0.26% in women who had not undergone hysterectomy. The prevalence ratios for ASC, LSIL and HSIL/SCC were 0.14 (0.11-0.17), 0.08 (0.06-0.13) and 0.13 (0.08-0.20), respectively, in women with a hysterectomy versus those without. For HSIL/SCC, the prevalence ratios were 0.09 and 0.29, respectively, for women <50 or ≥50years. The prevalence rates in women with a previous hysterectomy showed no significant variation with age. The prevalence rates of ASC, LSIL and HSIL/SCC were significantly lower in women with a previous hysterectomy for benign disease compared with those observed in women with an intact uterine cervix. This study reinforces the view that there is no evidence that cytological screening is beneficial for women who have had a hysterectomy for benign disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física