956 resultados para Uniaxial tensile test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this article research into the uniaxial tensile strength of Al2O3 monolithic ceramic is presented. The experimental procedure of the spalling of long bars is investigated from different approaches. This method is used to obtain the tensile strength at high strain rates under uniaxial conditions. Different methodologies proposed by several authors are used to obtain the tensile strength. The hypotheses needed for the experimental set-up are also checked, and the requirements of the set-up and the variables are also studied by means of numerical simulations. The research shows that the shape of the projectile is crucial to achieve successfully tests results. An experimental campaign has been carried out including high speed video and a digital image correlation system to obtain the tensile strength of alumina. Finally, a comparison of the test results provided by three different methods proposed by different authors is presented. The tensile strength obtained from the three such methods on the same specimens provides contrasting results. Mean values vary from one method to another but the trends are similar for two of the methods. The third method gives less scatter, though the mean values obtained are lower and do not follow the same trend as the other methods for the different specimens.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Distortion is one type of defect in the weld, which is troublesome for some reasons, especially in thin plate welding. Distortion was found in fibre laser welding processing for 0.7mm thickness Ti6Al4V plate. The purpose of this paper is to understand and evaluate the effect of distortion on stress level by FEA and tensile test. A group of 0.7mm Ti6Al4V plates welded using continuous wave fibre laser. FEA models were established for fibre laser welded Ti6Al4V in abaqus 6.7. © (2011) Trans Tech Publications.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

As estruturas coladas são geralmente projetadas para que o adesivo seja essencialmente sujeito a esforços de corte, pois neste tipo de solicitação o adesivo apresenta melhores caraterísticas mecânicas. A avaliação do comportamento ao corte pode ser realizada com o adesivo no estado maciço ou como camada fina em juntas adesivas. Os métodos que permitem avaliar o comportamento ao corte, quer para o adesivo, quer para as juntas, são: o ensaio Iosipescu ou V-Notched beam shear method, o ensaio de borboleta ou Notched plate shear method (Arcan), o ensaio de torsão, o ensaio de tração numa junta de sobreposição simples e o ensaio Thick Adherend Shear Test (TAST). Os ensaios Arcan e Iosipescu, tal como o ensaio de torção, podem ser realizados em provetes de adesivo maciço ou em juntas. O ensaio de torção é pouco utilizado, porque a aplicação do esforço de corte exige dispositivos e equipamentos de ensaios complexos. Os ensaios Arcan e Iosipescu utilizam provetes com entalhes e podem introduzir alguma dificuldade na medição precisa das deformações. O ensaio de tração numa junta de sobreposição simples é um dos métodos mais usados para caraterizar uma junta adesiva, porque é um método simples, as juntas são de fácil fabrico e pode ser realizado em máquinas universais de ensaios mecânicos. Neste ensaio os aderentes estão sujeitos a uma solicitação de tração, enquanto a camada de adesivo está sujeita a esforços de corte combinados com esforços de arrancamento. Os esforços de arrancamento resultam da própria geometria da junta na qual existe um desalinhamento das forças de tração, mesmo quando são colocados calços (reguladores de espessura) nos locais de amarração. O ensaio TAST é dos mais populares para obtenção das propriedades ao corte, uma vez que tanto as ferramentas de ensaio como o fabrico dos provetes são relativamente simples. Este ensaio é realizado em junta sendo os substratos espessos e de aço que, devido à sua elevada rigidez, contribuem para um esforço de corte praticamente puro no adesivo. Neste trabalho realizou-se o projeto e a fabricação das ferramentas, gabarit e substratos necessários para a execução de provetes TAST e ensaios utilizando diferentes adesivos.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The study was performed at OCAS, the Steel Research Centre of ArcelorMittal for the Industry market. The major aim of this research was to obtain an optimized tensile testing methodology with in-situ H-charging to reveal the hydrogen embrittlement in various high strength steels. The second aim of this study has been the mechanical characterization of the hydrogen effect on hight strength carbon steels with varying microstructure, i.e. ferrite-martensite and ferrite-bainite grades. The optimal parameters for H-charging - which influence the tensile test results (sample geometry type of electrolyte, charging methods effect of steel type, etc.) - were defined and applied to Slow Strain Rate testing, Incremental Step Loading and Constant Load Testing. To better understand the initiation and propagation of cracks during tensile testing with in-situ H-charging, and to make the correlation with crystallographic orientation, some materials have been analyzed in the SEM in combination with the EBSD technique. The introduction of a notch on the tensile samples permits to reach a significantly improved reproducibility of the results. Comparing the various steel grades reveals that Dual Phase (ferrite-martensite) steels are more sensitive to hydrogen induced cracking than the FB (ferritic-bainitic) ones. This higher sensitivity to hydrogen was found back in the reduced failure times, increased creep rates and enhanced crack initiation (SEM) for the Dual Phase steels in comparison with the FB steels.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The failure mechanism of a voided CFRP 0-90° cross-ply laminate under tensile loads applied in one direction was studied in this Final Degree Project. For this purpose, voided coupons were manufactured for being tested and a FEA was done. In both investigations, voids were placed in 90º and 0º direction, in order to understand the void location influence. On the one hand, the behaviour of the voided laminates was investigated through a FEM in order to preview the stress distribution within the material. On the other hand, voided specimens where manufactured by applying blowing agent in between the inner layers. These specimens were tested by a quasi-static step wise tensile test where data showing its real behaviour was collected. Specimens were X-rayed after each step of the test in order to investigate the failure mechanism of the composite. Data from the test was studied so that relations such as strength of the laminates, crack density per stress, void length per first crack at the void and void area per first crack at the specimen could be characterized

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this thesis was to identify the effects of different factors on the tension and tension relaxation of wet paper web after high-speed straining. The study was motivated by the plausible connection between wet web mechanical properties and wet web runnability on paper machines shown by previous studies. The mechanical properties of wet paper were examined using a fast tensile test rig with a strain rate of 1000%/s. Most of the tests were carried out with laboratory handsheets, but samples from a pilot paper machine were also used. The tension relaxation of paper was evaluated as the tension remaining after 0.475 s of relaxation (residual tension). The tensile and relaxation properties of wet webs were found to be strongly dependent on the quality and amount of fines. With low fines content, the tensile strength and residual tension of wet paper was mainly determined by the mechanical interactions between fibres at their contact points. As the fines strengthen the mechanical interaction in the network, the fibre properties also become important. Fibre deformations caused by the mechanical treatment of pulp were shown to reduce the mechanical properties of both dry and wet paper. However, the effect was significantly higher for wet paper. An increase of filler content from 10% to 25% greatly reduced the tensile strength of dry paper, but did not significantly impair wet web tensile strength or residual tension. Increased filler content in wet web was shown to increase the dryness of the wet web after the press section, which partly compensates for the reduction of fibrous material in the web. It is also presumable that fillers increase entanglement friction between fibres, which is beneficial for wet web strength. Different contaminants present in white water during sheet formation resulted in lowered surface tension and increased dryness after wet pressing. The addition of different contaminants reduced the tensile strength of the dry paper. The reduction of dry paper tensile strength could not be explained by the reduced surface tension, but rather on the tendency of different contaminants to interfere with the inter-fibre bonding. Additionally, wet web strength was not affected by the changes in the surface tension of white water or possible changes in the hydrophilicity of fibres caused by the addition of different contaminants. The spraying of different polymers on wet paper before wet pressing had a significant effect on both dry and wet web tensile strength, whereas wet web elastic modulus and residual tension were basically not affected. We suggest that the increase of dry and wet paper strength could be affected by the molecular level interactions between these chemicals and fibres. The most significant increases in dry and wet paper strength were achieved with a dual application of anionic and cationic polymers. Furthermore, selectively adding papermaking chemicals to different fibre fractions (as opposed to adding chemicals to the whole pulp) improved the wet web mechanical properties and the drainage of the pulp suspension.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The study evaluated the in vitro influence of pulse-repetition rate of Er:YAG laser and dentin depth on tensile bond strength of dentin-resin interface. Dentin surfaces of buccal or lingual surfaces from human third molars were submitted to tensile test in different depths (superficial, 1.0 and 1.5 mm) of the same dental area, using the same sample. Surface treatments were acid conditioning solely (control) and Er:YAG laser irradiation (80 mJ) followed by acid conditioning, with different pulse-repetition rates (1, 2, 3, or 4 Hz). Single bond/Z-250 system was used. The samples were stored in distilled water at 37 degrees C for 24 h, and then the first test (superficial dentine) was performed. The bond failures were analyzed. Following, the specimens were identified, grounded until 1.0- and 1.5-mm depths, submitted again to the treatments and to the second and, after that, to third-bond tests on a similar procedure and failure analysis. ANOVA and Tukey test demonstrated a significant difference (p < 0.001) for treatment and treatment X depth interaction (p < 0.05). The tested depths did not show influence (p > 0.05) on the bond strength of dentin-resin interface. It may be concluded that Er:YAG laser with 1, 2, 3, or 4 Hz combined with acid conditioning did not increase the resin tensile bond strength to dentin, regardless of dentin depth. (C) 2007 Wiley Periodicals, Inc.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work studied the immiscible blend of elastomeric poly(methyl methacrylate) (PMMA) with poly(ethylene terephthalate) (PET) bottle grade with and without the use of compatibilizer agent, poly(methyl methacrylate-co-glycidyl methacrylate - co-ethyl acrylate) (MGE). The characterizations of torque rheometry, melt flow index measurement (MFI), measuring the density and the degree of cristallinity by pycnometry, tensile testing, method of work essential fracture (EWF), scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were performed in pure polymer and blends PMMA/PET. The rheological results showed evidence of signs of chemical reaction between the epoxy group MGE with the end groups of the PET chains and also to the elastomeric phase of PMMA. The increase in the concentration of PET reduced torque and adding MGE increased the torque of the blend of PMMA/PET. The results of the MFI also show that elastomeric PMMA showed lower flow and thus higher viscosity than PET. In the results of picnometry observed that increasing the percentage of PET resulted in an increase in density and degree crystallinity of the blends PMMA/PET. The tensile test showed that increasing the percentage of PET resulted in an increase in ultimate strength and elastic modulus and decrease in elongation at break. However, in the phase inversion, where the blend showed evidence of a co-continuous morphology and also, with 30% PET dispersed phase and compatibilized with 5% MGE, there were significant results elongation at break compared to elastomeric PMMA. The applicability of the method of essential work of fracture was shown to be possible for most formulations. And it was observed that with increasing elastomeric PMMA in the formulations of the blends there was an improvement in specific amounts of essential work of fracture (We) and a decrease in the values of specific non-essential work of fracture (βWp)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

There are a number of damaging mechanisms that various materials can suffer in service. However, when working with polymer composite materials, this is something that requires analysis, especially when exposed to adverse environmental conditions. Thus, the objective of the present thesis is the study of the direct influence of environmental aging and the form of hybridization of the reinforcement woven on the structural stability, surfacedegradation and fracture process of polymer composites laminates. For this, the development of two polymer composite laminates was necessary, where one of them was reinforced with a bi-directional woven with hybrid strandsofkevlar-49/glass-Efibers, and the other also with a bi-directionalwoven, however with weft and warpformed of alternating strandsof Kevlar-49 fibers and glass-E fiber The reinforcementwoven are industrially manufactured. Both laminates use a polyester resin as a matrixand are made up of four layers each. All laminates were industrially prepared by the hand lay-up method of manufacturing. To do this, test specimens were manufactured of the respective laminates and submitted to environmental aging accelerated through the aging chamber. They were exposed to alternating cycles of UV radiation and moisture (heated steam) for a standard defined period. At the end of the exposure period the specimens were subjected to mechanical tests of uniaxial tensile and bending in three points and to the characterizationsof the fracture and surface deterioration. In addition, they were submitted to a structural degradation assessment by the measurement of mass variation technique (MMVT) and the measurement of thickness variation technique (MTVT), this last technique being developed in this thesis. At the end of the analysis it was observed that the form of hybridization of the reinforcement woven and the aging process directly influence with losses or gain in mechanical properties, with losses in the structural degradation and in the formation and propagation of damage mechanism of the developedcomposite laminates

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Due to gradual resorption of the edentulous ridge bone, removable prostheses often require denture base relines to improve fit and stability. This research evaluated the bond strength between one heat-cured acrylic resin (Lucitone 550®) and two hard chairside reline resins, after two different periods of storage in water (50 h and 30 days). The bond strength was evaluated using a tensile test. The mode of failure, adhesive or cohesive, was also recorded. The results submitted to the Kruskal-Wallis test indicated that the highest tensile strengths were achieved with intact Lucitone 550® denture base resin in both periods of storage in water. After 50 h of storage in water, Duraliner II® reline material exhibited the highest bond strength to the denture base resin. After 30 days of storage in water, Duraliner II® reline resin demonstrated a significant reduction in adhesion, showing lower tensile bond strength than Kooliner® material. Both hard chairside reline materials failed adhesively across Lucitone 550® denture base resin, in both periods of time. © 1999 Blackwell Science Ltd.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the work was to evaluate the influence of the temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy casting. Were obtained for the tensile strength test dumbbell rods that were invested in the Rematitan Plus investment and casting in the Discovery machine cast. Thirty specimens were obtained, fiftten to the CP Titanium and fifteen to the Ti-6Al-4V alloy, five samples to each an of the three temperatures of investment: 430°C (control group), 480°C and 530°C. The tensile test was measured by means of a universal testing machine, MTS model 810, at a strain of 1.0 mm/min. After the tensile strenght test the specimens were secctioned, embedded and polished to hardness measurements, using a Vickers tester, Micromet 2100. The means values to tensile tests to the temperatures 430°C, 480 and 530: CP Ti (486.1 - 501.16 - 498.14 -mean 495.30 MPa) and Ti-6Al-4V alloy (961.33 - 958.26 - 1005.80 - mean 975.13 MPa) while for the Vickers hardness the values were (198.06, 197.85, 202.58 - mean 199.50) and (352.95, 339.36, 344.76 - mean 345.69), respectively. The values were submitted to Analysis of Variance (ANOVA) and Tukey' s Test that indicate differences significant only between the materials, but not between the temperature, for both the materias. It was conclued that increase of the temperature of investment its not chance the tensile strength and the Vickers hardness of the CP Titanium and Ti-6Al-4V alloy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A major aspect in geosynthetics creep analysis is the load level applied to the specimen, usually referred as a percentage of the geosynthetic ultimate tensile strength (UTS). Since both tensile and creep standard tests are performed with in-isolation specimens, they may not reproduce the possibly significant effect of soil-geosynthetic interaction. A new creep testing machine was recently developed and successfully addressed this concern. However, further developments allowed tensile tests to be performed in the same conditions used in nonconventional creep ones. This paper presents the results of nonconventional tensile tests performed with a woven biaxial polyester geogrid. They were used to define its UTS in the same conditions employed in creep tests performed with the new equipment. Despite changes in tensile curves shapes were found, the UTS from confined, accelerated and confined-accelerated tensile tests were quite similar to those obtained with standard tensile test procedure.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study evaluated the effect of the core substrate type (dentin and composite resin) on the retention of crowns made of yttrium oxide stabilized tetragonal zirconia polycrystal (Y-TZP), submitted to three inner surface conditionings. For this purpose, 72 freshly extracted molars were embedded in acrylic resin, perpendicular to the long axis, and prepared for full crowns: 36 specimens had crown preparations in dentin; the remaining 36 teeth had the crowns removed, and crown preparations were reconstructed with composite resin plus fiber posts with dimensions identical to the prepared dentin. The preparations were impressed using addition silicone, and 72 Y-TZP copings for the tensile test were produced. Cementation was performed with a dual-cured cement containing phosphate monomers. For cementation, the crown preparation (dentin or resin) was conditioned with the adhesive system, and the ceramic was subjected to one of three surface treatments: isopropyl alcohol, tribochemical silica coating, or thin low-fusing glassy porcelain layer application plus silanization. After 24 hours, all specimens were submitted to thermocycling (6000 cycles) and placed in a special tensile testing device in a universal testing machine to determine failure loads. The failure modes of all samples were analyzed under a stereomicroscope. Two-way analysis of variance showed that the surface treatment and substrate type (alpha=0.05) affected the tensile retention results. The dentin substrate presented the highest tensile retention values, regardless of the surface treatment. When the substrate was resin, the tribochemical silica coating and low-fusing glaze application plus silanization groups showed the higher retention values.