Influence of the final temperature of investment healting on the tensile strength and Vickers hardness of CP TI and TI-6AL-4V alloy


Autoria(s): Oliveira, Pedro César Garcia de; Adabo, Gelson Luis; Ribeiro, Ricardo Faria; Rocha, Sicknan Soares da; Ávila, Fabiano Araújo; Valle, Accácio Lins do
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

27/05/2014

27/05/2014

01/01/2007

Resumo

The aim of the work was to evaluate the influence of the temperature of investment healting on the tensile strength and Vickers hardness of CP Ti and Ti-6Al-4V alloy casting. Were obtained for the tensile strength test dumbbell rods that were invested in the Rematitan Plus investment and casting in the Discovery machine cast. Thirty specimens were obtained, fiftten to the CP Titanium and fifteen to the Ti-6Al-4V alloy, five samples to each an of the three temperatures of investment: 430°C (control group), 480°C and 530°C. The tensile test was measured by means of a universal testing machine, MTS model 810, at a strain of 1.0 mm/min. After the tensile strenght test the specimens were secctioned, embedded and polished to hardness measurements, using a Vickers tester, Micromet 2100. The means values to tensile tests to the temperatures 430°C, 480 and 530: CP Ti (486.1 - 501.16 - 498.14 -mean 495.30 MPa) and Ti-6Al-4V alloy (961.33 - 958.26 - 1005.80 - mean 975.13 MPa) while for the Vickers hardness the values were (198.06, 197.85, 202.58 - mean 199.50) and (352.95, 339.36, 344.76 - mean 345.69), respectively. The values were submitted to Analysis of Variance (ANOVA) and Tukey' s Test that indicate differences significant only between the materials, but not between the temperature, for both the materias. It was conclued that increase of the temperature of investment its not chance the tensile strength and the Vickers hardness of the CP Titanium and Ti-6Al-4V alloy.

Formato

44-48

Identificador

http://dx.doi.org/10.1590/S1678-77572007000100010

Journal of Applied Oral Science, v. 15, n. 1, p. 44-48, 2007.

1678-7757

1678-7765

http://hdl.handle.net/11449/69478

10.1590/S1678-77572007000100010

S1678-77572007000100010

2-s2.0-34248519424

2-s2.0-34248519424.pdf

Idioma(s)

eng

Relação

Journal of Applied Oral Science

Direitos

openAccess

Palavras-Chave #Tensile strength #Titanium casting #Vickers hardnes
Tipo

info:eu-repo/semantics/article