972 resultados para Testing conditions
Resumo:
There is an apparent lack of research investigating how different test conditions influence or bias consumer sensory evaluation of food. The aim of the present pilot study was to determine if testing conditions had any effect on responses of an untrained panel to a novel chicken product. Assessments of flavour, texture and overall liking of corn-fed chicken were made across three different testing conditions (laboratory-based under normal lighting; laboratory-based under controlled lighting; and, home testing). Least favourable evaluations occurred under laboratory-based conditions irrespective of what lighting was used. Consumers perceived the product more favourably in terms of flavour (p < 0.001), texture (p < 0.001) and overall preference (p < 0.001) when evaluated in the familiar setting of the home. Home testing produced more consistent assessments than under either of the two laboratory-based test conditions. The results imply that home evaluation should be undertaken routinely in new food product development.
Resumo:
This thesis presents a system to recognise and classify road and traffic signs for the purpose of developing an inventory of them which could assist the highway engineers’ tasks of updating and maintaining them. It uses images taken by a camera from a moving vehicle. The system is based on three major stages: colour segmentation, recognition, and classification. Four colour segmentation algorithms are developed and tested. They are a shadow and highlight invariant, a dynamic threshold, a modification of de la Escalera’s algorithm and a Fuzzy colour segmentation algorithm. All algorithms are tested using hundreds of images and the shadow-highlight invariant algorithm is eventually chosen as the best performer. This is because it is immune to shadows and highlights. It is also robust as it was tested in different lighting conditions, weather conditions, and times of the day. Approximately 97% successful segmentation rate was achieved using this algorithm.Recognition of traffic signs is carried out using a fuzzy shape recogniser. Based on four shape measures - the rectangularity, triangularity, ellipticity, and octagonality, fuzzy rules were developed to determine the shape of the sign. Among these shape measures octangonality has been introduced in this research. The final decision of the recogniser is based on the combination of both the colour and shape of the sign. The recogniser was tested in a variety of testing conditions giving an overall performance of approximately 88%.Classification was undertaken using a Support Vector Machine (SVM) classifier. The classification is carried out in two stages: rim’s shape classification followed by the classification of interior of the sign. The classifier was trained and tested using binary images in addition to five different types of moments which are Geometric moments, Zernike moments, Legendre moments, Orthogonal Fourier-Mellin Moments, and Binary Haar features. The performance of the SVM was tested using different features, kernels, SVM types, SVM parameters, and moment’s orders. The average classification rate achieved is about 97%. Binary images show the best testing results followed by Legendre moments. Linear kernel gives the best testing results followed by RBF. C-SVM shows very good performance, but ?-SVM gives better results in some case.
Resumo:
Objectives. This study compared the durability of repair bond strength of a resin composite to a reinforced ceramic after three repair systems.Methods. Alumina-reinforced feldspathic ceramic blocks (Vitadur-alpha(R)) (N=30) were randomly divided into three groups according to the repair method: PR-Porcelain Repair Kit (Bisco) [etching with 9.5% hydrofluoric acid + silanization + adhesive]; CJ-CoJet Repair Kit (3M ESPE) [(chairside silica coating with 30 mu m SiO2 + silanization (ESPE(R)-Sil) + adhesive (Visio(TM)-Bond)]; CL-Clearfil Repair Kit [diamond surface roughening, etching with 40% H3PO4 + Clearfil Porcelain Bond Activator + Clearfil SE Bond)]. Resin composite was photo-polymerized on each conditioned ceramic block. Non-trimmed beam specimens were produced for the microtensile bond strength (mu TBS) tests. In order to study the hydrolytic durability of the repair methods, the beam specimens obtained from each block were randomly assigned to two conditions. Half of the specimens were tested either immediately after beam production (Dry) or after long-term water storage (37 degrees C, 150 days) followed by thermocyling (12,000 cycles, 5-55 degrees C) in a universal testing machine (1 mm/min). Failure types were analyzed under an optical microscope and SEM.Results. mu TBS results were significantly affected by the repair method (p=0.0001) and the aging conditions (p=0.0001) (two-way ANOVA, Tukey's test). In dry testing conditions, PR method showed significantly higher (p < 0.001) repair bond strength (19.8 +/- 3.8 MPa) than those of CJ and CL (12.4 +/- 4.7 and 9.9 +/- 2.9, respectively). After long-term water storage and thermocycling, CJ revealed significantly higher results (14.5 +/- 3.1 MPa) than those of PR (12.1 +/- 2.6 MPa) (p < 0.01) and CL (4.2 +/- 2.1 MPa) (p < 0.001). In all groups when tested in dry conditions, cohesive failure in the composite accompanied with adhesive failure at the interface (mixed failures), was frequently observed (76%, 80%, 65% for PR, CJ and CL, respectively). After aging conditions, while the specimens treated with PR and CJ presented primarily mixed failure types (52% and 87%, respectively), CL group presented mainly complete adhesive failures at the interface (70%).Significance. Hydrolytic stability of the repair method based on silica coating and silanization was superior to the other repair strategies for the ceramic tested. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Com a finalidade de quantificar o desempenho dos sistemas de debulhamento e limpeza da colhedora Penha CLM-350,, estudou-se as perdas percentuais era grão de milho, ocorridos na saída de palhas, bem como a porcentagem de impurezas, presente no milho ensacado. Tomando-se como 100% os grãos de milho colhidos pelo sistema espigador, determinou-se o valor percentual perdido pelos sistemas de debulhamento e limpeza, bem como a porcentagem de impurezas presente nos grãos de milho ensacado, nos diversos tratamentos estudados. O teor médio de umidade foi de 15,78% (b.u.). Os tratamentos correspondentes ao sistema de debulhamento e limpeza são as velocidades periféricas do debulhador ou as rotações do aspirador em faces da configuração geométrica da máquina. Os resultados obtidos foram estudados através da análise de variância, empregando-se os testes F, aos níveis de 1% e 5% de probabilidade e o teste Tukey, para a comparação estatística entre as médias. A análise estatística para verificar a influência da rotação do aspirador, era relação a porcentagem de grãos de milho perdidos na saída de palhas, mostrou diferenças altamente significativas, podendo-se admitir uma relação direta entre os dois parâmetros nas condições do ensaio. Com relação a rotação do aspirador e a porcentagem de impurezas, presentes nos grãos de milho ensacados, os testes das médias revelaram significância entre os tratamento D (1241,7 rpm) e E (820 rpm) sendo que este último apresentou a maior média. Uma análise mais acurada dos resultados sugere que a porcentagem de impurezas, estaria mais na dependência das relações de fluxo através da colhedora, do que propriamente do regime do aspirador.
Resumo:
TEMA: o controle do tamanho da abertura velofaríngea é uma variável importante na caracterização do perfil acústico da fala hipernasal. OBJETIVO: investigar os aspectos espectrais das frequências de F1, F2, F3, formante nasal(FN) e anti-formante, em Hertz, para as vogais [a] e [ã] na presença de aberturas feitas no bulbo de réplicas da prótese de palato de uma paciente com insuficiência velofaríngea. MÉTODO: gravações de produções de quatro palavras (pato/mato e panto/manto) inseridas em frase veículo foram obtidas em cinco condições de funcionamento velofaríngeo: prótese sem aberturas (condição controle: CC), prótese com abertura de 10mm² no bulbo (condição experimental - CE10), com abertura de 20mm² (condição experimental - CE20), com abertura de 30mm² (condição experimental - CE30), e sem prótese (condição experimental aberta - CEA). Cinco fonoaudiólogos julgaram a nasalidade de fala ao vivo, durante a leitura de um texto oral. As gravações foram usadas para análise espectral. RESULTADOS: valores de F1 foram significativamente mais altos para [a] que para [ã] em todas as condições. Valores de F2 para [a] em CE20 e CE30 foram significantemente mais baixos que nas outras condições, aproximando-se dos valores para [ã]. Valores de F3 não foram significativamente diferentes nas diferentes condições. Houve relação entre os achados de FN e anti-formantes e a percepção de nasalidade para as condições CE10 e CE20. CONCLUSÃO: foram observadas mudanças significativas nos valores espectrais estudados de acordo com alterações no tamanho da abertura velofaríngea.
Resumo:
The mechanisms of material removal and the interactions among scratches performed in ceramic materials were investigated using acoustic emission signals, and scanning electron microscopy, in scratching experiments. Several testing conditions were used to produce different types of removing mechanism on a glass as well as on a polycrystalline alumina sample composed by heterogeneous grain size. It is known that the material removing process on a polycrystalline ceramic involves intergranular microfracture and grain dislodgement, unlike the chipping produced by the extension of lateral cracks in non-granular materials, such as glass. Distinct settings for velocities, loads, and two types of diamond indenter were tested. The material removal was carried out by three different methods of scratching: single passes, repeated overlapping passes, and parallel scratches. As a general result, there was a clear relationship between the acoustic emission signals and the damage intensity occurred in the material removal. More specifically, there were differences in the acoustic emission signal levels in the scratches made on the alumina and on the glass owing to the material removal mechanisms associated with the structure of these materials. A gradual increase in the acoustic emission levels was observed when the number of repeated passes was increased as a result of the damage accumulation process followed by severe material removal. It was also noticed that the acoustic emission signals were capable of reflecting the interactions between two parallel scratches.
Resumo:
This study aimed to determine whether: i) tethered-swimming can be used to identify the asymmetry during front crawl swimming style; ii) swimmers that perform unilateral breathing present greater asymmetry in comparison to others that use bilateral breathing; iii) swimmers of best performance present smaller asymmetry than their counterparts; iv) repeated front crawl swimming movements influence body asymmetry. 18 swimmers were assessed for propulsive force parameters (peak force, mean force, impulse and rate of force development) during a maximal front crawl tethered-swimming test lasting 2 min. A factorial analysis showed that propulsive forces decreased at the beginning, intermediate and end of the test (p<0.05), but the asymmetries were not changed at different instants of the test. When breathing preference (uni- or bilateral) was analyzed, asymmetry remained unchanged in all force parameters (p>0.05). When performance was considered (below or above mean group time), a larger asymmetry was found in the sub-group of lower performance in comparison to those of best performance (p<0.05). Therefore, the asymmetries of the propulsive forces can be detected using tethered-swimming. The propulsive forces decreased during the test but asymmetries did not change under testing conditions. Although breathing preference did not influence asymmetry, swimmers with best performance were less asymmetric than their counterparts. © Georg Thieme Verlag KG Stuttgart New York.
Resumo:
The influence of Ta concentration on the stability of BaCe 0.9-xTaxY0.1O3-δ (where x=0.01, 0.03 and 0.05) powders and sintered samples in CO2, their microstructure and electrical properties were investigated. The ceramic powders were synthesized by the method of solid state reaction, uniaxially pressed and sintered at 1550 °C to form dense electrolyte pellets. A significant stability in CO2 indicated by the X-ray analysis performed was observed for the samples with x≥0.03. The electrical conductivities determined by impedance measurements in the temperature range of 550-750 °C and in various atmospheres (dry argon, wet argon and wet hydrogen) increased with temperature but decreased with Ta concentration. The highest conductivities were observed in the wet hydrogen atmosphere, followed by those in wet argon, while the lowest were obtained in the dry argon atmosphere for each dopant concentration. The composition with Ta content of 3 mol% showed satisfactory characteristics: good resistance to CO2 in extreme testing conditions, while a somewhat reduced electrical conductivity is still comparable with that of BaCe0.9Y0.1O3-δ. © 2012 Elsevier Ltd and Techna Group S.r.l.
Resumo:
No contexto de procedimentos de pareamento ao modelo com sujeitos humanos, após o ensino de algumas relações condicionais, desempenhos emergentes, que são reflexivos, simétricos e transitivos às relações diretamente ensinadas são geralmente verificados, fato que não é facilmente observado com não humanos. Esses resultados negativos podem ser atribuídos a testes em extinção e conseqüente deterioração de desempenho. O objetivo deste estudo foi criar condições de teste em extinção a fim de superar esses problemas. O sujeito foi um macaco-prego, o qual, como resultado de sua história experimental, era capaz de realizar com sucesso testes de pareamento ao modelo por identidade (IDMTS)com reforçamento. Foi usado um procedimento IDMTS com atraso zero. Testes repetidos de IDMTS e IDMTS generalizado foram arranjados de forma que as tentativas de teste foram inseridas entre tentativas de linha de base. Testes com reforçamento foram alternados com testes em extinção. Estas condições foram suficientes para manter o desempenho bem acima do acaso na grande maioria dos testes (20 de um total de 21). O macaco-prego mostrou capacidade de desempenhar IDMTS com sucesso, com novos estímulos, com ou sem reforçamento.
Resumo:
Objective: To compare the efficacy of the mouthwashes 0.12% chlorhexidine, Listerine, and 0.5% and 2% Melaleuca Alternifolia oil against the salivary levels of Streptococcus mutans and total microorganisms. Methods: This study was double-blind controlled and paired clinical assay. Twenty-six volunteers aged 21 to 35 years old were enrolled. At baseline, 1 mL of unstimulated saliva was collected from each subject, 1 and 15 min after mouthrinsing with the following solutions: sterile distilled water, 0.12% chlorhexidine digluconate, Listerine (©Johnson & Johnson do Brasil), 0.5% and 2% concentrations of Melaleuca Alternifolia (Sigma-Aldrich). The volunteers used all the evaluated mouthrinses with a 15-day interval between the solutions. Immediately after rinsing, saliva was collected and serial dilutions were performed, followed by plating in blood agar culture medium for growth of total microorganisms and SB-20 (Sucrose-Bacitracin agar) for growth of S. mutans, and incubation at 37 °C for 48 h in microaerophilia. After incubation, the number of colonies was counted and expressed as colony forming units (UFC/mL). Results: Chlorhexidine showed antimicrobial action by reducing total microorganisms and S. mutans, while the action of 0.5% Melaleuca Alternifolia was similar to that of distilled water. Listerine and 2% Melaleuca Alternifolia oil reduced total microbial counts by 11% and 9% respectively, and S. mutans by 20% and 11%. Conclusion: A single rinse with 0.12% chlorhexidine is effective in reducing the levels of total microorganisms and S. mutans present in saliva. Under the same testing conditions, Listerine and 0.5% and 2% Melaleuca Alternifolia oil presented lower efficacy than chlorhexidine.
Resumo:
Several strains of Enterococcus spp. are capable of producing bacteriocins with antimicrobial activity against important bacterial pathogens in dairy products. In this study, the bacteriocins produced by two Enterococcus strains (Enterococcus mundtii CRL35 and Enterococcus faecium ST88Ch), isolated from cheeses, were characterized and tested for their capability to control growth of Listeria monocytogenes 426 in experimentally contaminated fresh Minas cheese during refrigerated storage. Both strains were active against a variety of pathogenic and non-pathogenic microorganisms and bacteriocin absorption to various L. monocytogenes, Enterococcus faecalis ATCC 19443 and Lactobacillus sakei ATCC 15521 varied according to the strain and the testing conditions (pH, temperature, presence of salts and surfactants). Growth of L. monocytogenes 426 was inhibited in cheeses containing E. mundtii CRL35 up to 12 days at 8 degrees C, evidencing a bacteriostatic effect. E. faecium ST88Ch was less effective, as the bacteriostatic affect occurred only after 6 days at 8 degrees C. In cheeses containing nisin (12.5 mg/kg), less than one log reduction was observed. This research underlines the potential application of E. mundtii CRL35 in the control of L. monocytogenes in Minas cheese. (c) 2012 Elsevier Ltd. All rights reserved.
Resumo:
The variability of toxicity data contained within databases was investigated using the widely used US EPA ECOTOX database as an example. Fish acute lethality (LC50) values for 44 compounds (for which at least 10 data entries existed) were extracted from the ECOTOX database yielding a total of 4654 test records. Significant variability of LC50 test results was observed, exceeding several orders of magnitude. In an attempt to systematically explore potential causes of the data variability, the influence of biological factors (such as test species or life stages) and physical factors (such as water temperature, pH or water hardness) were examined. Even after eliminating the influence of these inherent factors, considerable data variability remained, suggesting an important role of factors relating to technical and measurement procedures. The analysis, however, was limited by pronounced gaps in the test documentation. Of the 4654 extracted test reports, 66.5% provided no information on the fish life stage used for testing. Likewise, water temperature, hardness or pH were not recorded in 19.6%, 48.2% and 41.2% of the data entries, respectively. From these findings, we recommend the rigorous control of data entries ensuring complete recording of testing conditions. A more consistent database will help to better discriminate between technical and natural variability of the test data, which is of importance in ecological risk assessment for extrapolation from laboratory tests to the field, and also might help to develop correction factors that account for systematic differences in test results caused by species, life stage or test conditions.
Resumo:
BACKGROUND Recent technical development allows the digital manufacturing of monolithic reconstructions with high-performance materials. For implant-supported crowns, the fixation requires an abutment design onto which the reconstruction can be bonded. PURPOSE The aim of this laboratory investigation was to analyze stiffness, strength, and failure modes of implant-supported, computer-assisted design and computer-aided manufacturing (CAD/CAM)-generated resin nano ceramic (RNC) crowns bonded to three different titanium abutments. MATERIALS AND METHODS Eighteen monolithic RNC crowns were produced and loaded in a universal testing machine under quasi-static condition according to DIN ISO 14801. With regard to the type of titanium abutment, three groups were defined: (1) prefabricated cementable standard; (2) CAD/CAM-constructed individualized; and (3) novel prefabricated bonding base. Stiffness and strength were measured and analyzed statistically with Wilcoxon rank sum test. Sections of the specimens were examined microscopically. RESULTS Stiffness demonstrated high stability for all specimens loaded in the physiological loading range with means and standard deviations of 1,579 ± 120 N/mm (group A), 1,733 ± 89 N/mm (group B), and 1,704 ± 162 N/mm (group C). Mean strength of the novel prefabricated bonding base (group C) was 17% lower than of the two other groups. Plastic deformations were detectable for all implant-abutment crown connections. CONCLUSIONS Monolithic implant crowns made of RNC seem to represent a feasible and stable prosthetic construction under laboratory testing conditions with strength higher than the average occlusal force, independent of the different abutment designs used in this investigation.
Resumo:
The microstructural evolution of an AZ31 rolled sheet during dynamic deformation at strain rates of ∼103 s−1 has been investigated by electron backscatter diffraction, X-ray and neutron diffraction. The influence of orientation on the predominant deformation mechanisms and on the recovery processes taking place during deformation has been systematically examined. The results have been compared with those corresponding to the same alloy tested quasi-statically under equivalent conditions. It has been found that strain rate enhances the activation of extension twinning dramatically, while contraction and secondary twinning are not significantly influenced. The polarity of extension twinning is even reversed in some grains under selected testing conditions. Significant grain subdivision by the formation of geometrically necessary boundaries (GNBs) takes place during both quasi-static and dynamic deformation of this AZ31 alloy. It is remarkable that GNBs of high misorientations form even at the highest strain rates. The phenomenon of recovery has been found to be orientation dependent
Resumo:
There is evidence for both advantages and disadvantages in normal recognition of living over nonliving things. This paradox has been attributed to high levels of perceptual similarity within living categories having a different effect on performance in different contexts. However, since living things are intrinsically more similar to each other, previous studies could not determine whether the various category effects were due to perceptual similarity, or to other characteristics of living things. We used novel animal and vehicle stimuli that were matched for similarity to measure the influence of perceptual similarity in different contexts. We found that displaying highly similar objects in blocked sets reduced their perceived similarity, eliminating the detrimental effect on naming performance. Experiment 1 demonstrated a disadvantage for highly similar objects in name learning and name verification using mixed groups of similar and dissimilar animals and vehicles. Experiment 2 demonstrated no disadvantage for the same highly similar objects when they were blocked, e.g., similar animals presented alone. Thus, perceptual similarity, rather than other characteristics particular to living things, is affected by context, and could create apparent category effects under certain testing conditions.