862 resultados para THERMAL PERFORMANCE
Resumo:
This paper reports on research that uses building performance simulation and uncertainty analysis to assess the risks that projected climate change poses to the thermal performance of buildings, and to their critical functions. The work takes meteorological climate change predictions as a starting point, but also takes into account developments and uncertainties in technology, occupancy, intervention and renovation, and others. Four cases are studied in depth to explore the prospects of the quantification of said climate change risks. The research concludes that quantification of the risks posed by climate change is possible, but only with many restrictive assumptions on the input side.
Resumo:
In this paper, a mini-staged multi-stacked quantum cascade laser structure with a designed wavelength of 4.7 mu m is presented. By introducing five 0.5 mu m thick high thermal conductivity InP interbuffer layers, the 60-stages active region core of the quantum cascade laser is divided into six equal parts. Based on simulation, this kind of quantum cascade laser with a 10 mu m ridge width gives nearly circular two-dimensional far-field distribution (FWHM = 32.8 degrees x 29 degrees) and good beam quality parameters M-2 = 1.32 x 1.31 in the fast axis (growth direction) and the slow axis (lateral direction). Due to the enhancement of lateral heat extraction through the interbuffer layers, compared to the conventional structure, a decrease of about 5-6% for the maximum temperature in the active region core of the mini-staged multi-stacked quantum cascade laser with indium-surrounded and gold-electroplated packaging profiles is obtained at all possible dissipated electrical power levels.
Resumo:
Premixed combustion of hydrogen gas and air was performed in a stainless steel based micro-annular combustor for a micro-gas turbine system. Micro-scale combustion has proved to be stable in the micro-combustor with a gap of 2 mm. The operating range of the micro-combustor was measured, and the maximum excess air ratio is up to 4.5. The distribution of the outer wall temperature and the temperature of exhaust gas of the micro-conbustor with excess air ratio were obtained, and the wall temperature of the micro-combustor reaches its maximum value at the excess air ratio of 0.9 instead of 1 (stoichiometric ratio). The heat loss of the micro-combustor to the environment was calculated and even exceeds 70% of the total thermal power computed from the consumed hydrogen mass flow rate. Moreover, radiant hunt transfer covers a large fraction of the total heat loss. Measures used to reduce the heat loss were proposed to improve the thermal performance of the micro-combustor. The optimal operating status of the micro-combustor and micro-gas turbine is analyzed and proposed by analyzing the relationship of the temperature of the exhaust gas of the micro-combustor with thermal power and excess air ratio. The investigation of the thermal performance of the micro-combustor is helpful to design an improved microcombustor.
Resumo:
Window design plays an important role in achieving energy efficient buildings and in providing thermal comfort of building occupants. This paper investigates a newly developed aerogel window and the potential improvement on the comfort factors of an office in relation to daylighting. Improved comfort levels can impact on health and wellbeing of building occupants leading to knock on effects on absenteeism and productivity. A simulation tool was presently created that will easily enable comparison of different façade design and their impact on heat and light transmission and therefore enable optimisation. One of the most important aspects of the present work was comparing the performance of the newly developed aerogel window against the more traditional Argon-filled, coated double-glazing. Whereas the aerogel window provided an extremely low heat-loss index of 0.3 W/m2K, the latter usually offered a centre-glazing U-value of 1.4 W/m2K. On a like-with-like basis the daylight transmission of the aerogel window was significantly lower than double-glazing. However, in view of low thermal loss larger areas of the former can be deployed. This article presents the influence of three key parameters that may lead to an optimum design: daylight, thermal loss and solar gain.
Resumo:
For Variable Stiffness (VS) composites with steered curvilinear tow paths, the fiber orientation angle varies continuously throughout the laminate, and is not required to be straight, parallel and uniform within each ply as in conventional composite laminates. Hence, the thermal properties (conduction), as well as the structural stiffness and strength, vary as functions of location in the laminate, and the associated composite structure is often called a “variable stiffness” composite structure. The steered fibers lead not only to the alteration of mechanical load paths, but also to the alteration of thermal paths that may
result in favorable temperature distributions within the laminate and improve the laminate performance. Evaluation of VS laminate performance under thermal loading is the focus of this chapter. Thermal performance evaluations require experimental and numerical analysis of VS laminates under different processing and loading conditions. One of the advantages of using composite materials in many applications is the tailoring capability of the laminate,
not only during the design phase but also for manufacturing. Heat transfer through variable conduction and chemical reaction (degree of cure) occurring during manufacturing (curing) plays an important role in the final thermal and mechanical performance, and shape of composite structures.
Resumo:
The buried oxide (BOX) layer in silicon on insulator (SOI) was replaced by a compound buried layer (CBL) containing layers of SiO2, polycrystalline silicon (polysilicon), and SiO2. The undoped polysilicon in the CBL acted as a dielectric with a higher thermal conductivity than SiO2. CBL provides a reduced thermal resistance with the same equivalent oxide thickness as a standard SiO2 buried layer. Thermal resistance was further reduced by lateral heat flow through the polysilicon. Reduction in thermal resistance by up to 68% was observed, dependent on polysilicon thickness. CBL SOI substrates were designed and manufactured to achieve a 40% reduction in thermal resistance compared with an 1.0-μm SiO2 BOX. Power bipolar transistors with an active silicon layer thickness of 13.5 μm manufactured on CBL SOI substrates showed a 5%-17% reduction in thermal resistance compared with the standard SOI. This reduction was dependent on transistor layout geometry. Between 65% and 90% of the heat flow from these power transistors is laterally through the thick active silicon layer. Analysis confirmed that CBL SOI provided a 40% reduction in the vertical path thermal resistance. Devices employing thinner active silicon layers will achieve the greater benefit from reduction in vertical path thermal resistance offered by CBL SOI.
Resumo:
The objective of this study is to compare the performance of the equipment currently employed in the domestic heating with firewood, the conventional fireplace and the inset appliance with close firedoors. For such, it was followed the European Standard EN13229:2001/A2:2004. Efficiency and heat output is determined and the major heat losses that penalize the appliance performance are identified and calculated. Tests in laboratory were developed in two inset appliances, and tests in situ in one conventional fireplace. One of the appliances uses only staging as primary air, and the other only grate air In inset appliances, with a heat output near 10 kW, the average efficiency varies between 67% and 73%, while in a conventional fireplace that value lies at 30%. In all these devices the major losses take place as sensible heat in the flue gases, 23% to 30 % in inset appliances and above 50% in a conventional fireplace. The second most important heat loss happens by chemical losses in the flue gases. It takes values near 17% in a conventional fireplace and may be disregarded in an inset appliance.
Resumo:
The thermal performance of a horizontal-coupled ground-source heat pump system has been assessed both experimentally and numerically in a UK climate. A numerical simulation of thermal behaviour of the horizontal-coupled heat exchanger for combinations of different ambient air temperatures, wind speeds, refrigerant temperature and soil thermal properties was studied using a validated 2D transient model. The specific heat extraction by the heat exchanger increased with ambient temperature and soil thermal conductivity, however it decreased with increasing refrigerant temperature. The effect of wind speed was negligible.
Comparing the thermal performance of horizontal slinky-loop and vertical slinky-loop heat exchangers
Resumo:
The heat pump market in the UK has grown rapidly over the last few years. Performance analyses of vertical ground-loop heat exchanger configurations have been widely carried out using both numerical modelling and experiments. However, research findings and design recommendations on horizontal slinky-loop and vertical slinky-loop heat exchangers are far fewer compared with those for vertical ground-loop heat exchanger configurations, especially where the long-term operation of the systems is concerned. The paper presents the results obtained from a numerical simulation for the horizontal slinky-loop and vertical slinky-loop heat exchangers of a ground-source heat pump system. A three-dimensional numerical heat transfer model was developed to study the thermal performance of various heat exchanger configurations. The influence of the loop pitch (loop spacing) and the depth of a vertical slinky-loop installation were investigated and the thermal performance and excavation work required for the horizontal and vertical slinky-loop heat exchangers were compared. The influence of the installation depth for vertical slinky-loop configurations was also investigated. The results of this study show that the influence of the installation depth of the vertical slinky-loop heat exchanger on the thermal performance of the system is small. The maximum difference in the thermal performance between the vertical and horizontal slinky-loop heat exchangers with the same loop diameter and loop pitch is less than 5%.
Resumo:
This paper presents results obtained from a numerical simulation for the horizontal slinky-loop heat exchanger of a ground-source heat pump system. A three-dimensional numerical model was developed and the results of the thermal performance of various heat exchanger configurations are presented. The investigation was carried out on five types of loop pitch (loop spacing), three types of loop diameter, three values of soil thermal properties, and allowing continuous and intermittent operation. Comparison was made for the heat transfer rate, the amount of pipe material needed, as well as excavation work required for the horizontal slinky-loop heat exchanger. The results indicate that system parameters have a significant effect on the thermal performance of the system
Resumo:
Cool materials are characterized by having a high solar reflectance r – which is able to reduce heat gains during daytime - and a high thermal emissivity ε that enables them to dissipate the heat absorbed throughout the day during night. Despite the concept of cool roofs - i.e. the application of cool materials to roof surfaces - is well known in US since 1990s, many studies focused on their performance in both residential and commercial sectors under various climatic conditions for US countries, while only a few case studies are analyzed in EU countries. The present work aims at analyzing the thermal benefits due to their application to existing office buildings located in EU countries. Indeed, due to their weight in the existing buildings stock, as well as the very low rate of new buildings construction, the retrofit of office buildings is a topic of great concern worldwide. After an in-depth characterization of the existing buildings stock in the EU, the book gives an insight into roof energy balance due to different technological solutions, showing in which cases and to what extent cool roofs are preferable. A detailed description of the physical properties of cool materials and their availability on the market provides a solid background for the parametric analysis carried out by means of detailed numerical models that aims at evaluating cool roofs performance for various climates and office buildings configurations. With the help of dynamic simulations, the thermal behavior of representative office buildings of the existing EU buildings stock is assessed in terms of thermal comfort and energy needs for air conditioning. The results, which consider several variations of building features that may affect the resulting energy balance, show how cool roofs are an effective strategy for reducing overheating occurrences and thus improving thermal comfort in any climate. On the other hand, potential heating penalties due to a reduction in the incoming heat fluxes through the roof are taken into account, as well as the aging process of cool materials. Finally, an economic analysis of the best performing models shows the boundaries for their economic convenience.
Resumo:
The objective of this work was to analyze mechanical, physical and thermal performance of roofing tiles produced with several formulations of cement-based matrices reinforced with sisal and eucalyptus fibers. The physical properties of the tiles were more influenced by the fiber content of the composite than by the type of reinforcement. The type of the fiber was the main variable for the achievement of the best results of mechanical properties. Exposure to tropical climate has caused a severe reduction in the mechanical properties of the composites. After approximately four months of age under external weathering the toughness of the vegetable fiber-cement fell to 53-68% of the initial toughness at 28 days of age. The thermal performance showed that roofing tiles reinforced with vegetable fiber are acceptable as substitutes of asbestos-cement sheets. (c) 2006 Elsevier Ltd. All rights reserved.