998 resultados para Surface dose
Resumo:
Background Data: Photodynamic therapy (PDT) involves the photoinduction of cytotoxicity using a photosensitizer agent, a light source of the proper wavelength, and the presence of molecular oxygen. A model for tissue response to PDT based on the photodynamic threshold dose (Dth) has been widely used. In this model cells exposed to doses below Dth survive while at doses above the Dth necrosis takes place. Objective: This study evaluated the light Dth values by using two different methods of determination. One model concerns the depth of necrosis and the other the width of superficial necrosis. Materials and Methods: Using normal rat liver we investigated the depth and width of necrosis induced by PDT when a laser with a gaussian intensity profile is used. Different light doses, photosensitizers (Photogem, Photofrin, Photosan, Foscan, Photodithazine, and Radachlorin), and concentrations were employed. Each experiment was performed on five animals and the average and standard deviations were calculated. Results: A simple depth and width of necrosis model analysis allows us to determine the threshold dose by measuring both depth and surface data. Comparison shows that both measurements provide the same value within the degree of experimental error. Conclusion: This work demonstrates that by knowing the extent of the superficial necrotic area of a target tissue irradiated by a gaussian light beam, it is possible to estimate the threshold dose. This technique may find application where the determination of Dth must be done without cutting the tissue.
Resumo:
Shallow subsurface layers of gold nanoclusters were formed in polymethylmethacrylate (PMMA) polymer by very low energy (49 eV) gold ion implantation. The ion implantation process was modeled by computer simulation and accurately predicted the layer depth and width. Transmission electron microscopy (TEM) was used to image the buried layer and individual nanoclusters; the layer width was similar to 6-8 nm and the cluster diameter was similar to 5-6 nm. Surface plasmon resonance (SPR) absorption effects were observed by UV-visible spectroscopy. The TEM and SPR results were related to prior measurements of electrical conductivity of Au-doped PMMA, and excellent consistency was found with a model of electrical conductivity in which either at low implantation dose the individual nanoclusters are separated and do not physically touch each other, or at higher implantation dose the nanoclusters touch each other to form a random resistor network (percolation model). (C) 2009 American Vacuum Society. [DOI: 10.1116/1.3231449]
Resumo:
Objectives: The purpose of this study was to explore the clinical relevance of chronic exposure to ambient levels of traffic derived air pollution on the ocular surface. Methods: A panel study involving 55 volunteers was carried out in Sao Paulo, Brazil. We measured the mean individual levels of nitrogen dioxide (NO(2)) exposure for 7 days. All subjects answered the Ocular Symptom Disease Index (OSDI) and a symptoms inventory. Subsequently, subjects underwent Schirmer I test, biomicroscopy, vital staining and tear breakup time (TOUT) assessment. Subject`s mean daily exposure to NO(2) was categorized in quartiles. Statistical analysis was performed using one-way ANOVA, Tukey HSD and Chi-Square tests. Results: A dose-response pattern was detected between OSDI scores and NO(2) quartiles (p < 0.05). There was a significant association between NO(2) quartiles and reported ocular irritation (X(2) = 9.2, p < 0.05) and a significant negative association between TBUT and NO(2) exposure (p < 0.05, R = -0.316. Spearman`s correlation). There was a significant increase in the frequency of meibomitis in subjects exposed to higher levels of NO(2) (p < 0.05). Conclusions: Subjects exposed to higher levels of traffic derived air pollution reported more ocular discomfort symptoms and presented greater tear film instability, suggesting that the ocular discomfort symptoms and tear breakup time could be used as convenient bioindicators of the adverse health effects of traffic derived air pollution exposure. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Leptospira interrogans is the etiological agent of leptospirosis, a zoonotic disease that affects populations worldwide. We have identified in proteomic studies a protein that is encoded by the gene LIC10314 and expressed in virulent strain of L. interrogans serovar Pomona. This protein was predicted to be surface exposed by PSORT program and contains a p83/100 domain identified by BLAST analysis that is conserved in protein antigens of several strains of Borrelia and Treponema spp. The proteins containing this domain have been claimed antigen candidates for serodiagnosis of Lyme borreliosis. Thus, we have cloned the LIC10314 and expressed the protein in Escherichia coli BL21-SI strain by using the expression vector pAE. The recombinant protein tagged with N-terminal hexahistidine was purified by metal-charged chromatography and characterized by circular dichroism spectroscopy. This protein is conserved among several species of pathogenic Leptospira and absent in the saprophytic strain L. biflexa. We confirm by liquid-phase immunofluorescence assays with living organisms that this protein is most likely a new surface leptospiral protein. The ability of the protein to mediate attachment to ECM components was evaluated by binding assays. The leptospiral protein encoded by LIC10314, named Lsa63 (Leptospiral surface adhesin of 63 kDa), binds strongly to laminin and collagen IV in a dose-dependent and saturable fashion. In addition, Lsa63 is probably expressed during infection since it was recognized by antibodies of serum samples of confirmed-leptospirosis patients in convalescent phase of the disease. Altogether, the data suggests that this novel identified surface protein may be involved in leptospiral pathogenesis. (C) 2009 The British Infection Society. Published by Elsevier Ltd. All rights reserved.
Resumo:
Pathogenic Leptospira species are the etiological agents of leptospirosis, a widespread disease of human and veterinary concern. In this study, we report that Leptospira species are capable of binding plasminogen (PLG) in vitro. The binding to the leptospiral surface was demonstrated by indirect immunofluorescence confocal microscopy with living bacteria. The PLG binding to the bacteria seems to occur via lysine residues because the ligation is inhibited by addition of the lysine analog 6-aminocaproic acid. Exogenously provided urokinase-type PLG activator (uPA) converts surface-bound PLG into enzymatically active plasmin, as evaluated by the reaction with the chromogenic plasmin substrate D-Val-Leu-Lys 4-nitroanilide dihydrochloridein. The PLG activation system on the surface of Leptospira is PLG dose dependent and does not cause injury to the organism, as cellular growth in culture was not impaired. The generation of active plasmin within Leptospira was observed with several nonvirulent high-passage strains and with the nonpathogenic saprophytic organism Leptospira biflexa. Statistically significant higher activation of plasmin was detected with a low-passage infectious strain of Leptospira. Plasmin-coated virulent Leptospira interrogans bacteria were capable of degrading purified extracellular matrix fibronectin. The breakdown of fibronectin was not observed with untreated bacteria. Our data provide for the first time in vitro evidence for the generation of active plasmin on the surface of Leptospira, a step that may contribute to leptospiral invasiveness.
Resumo:
Antibodies have the potential to be therapeutic reagents for malaria. Here we describe the production of a novel phage antibody display library against the C-terminal 19 kDa region of the Plasmodium yoelii YM merozoite surface protein-1 (MSP1(19)). In vivo studies against homologous lethal malaria challenge show an anti-parasite effect in a dose dependent manner, and analysis by plasmon resonance indicates binding to the antigen is comparable to the binding of a protective monoclonal antibody. The data support the lack of a need for any antibody Fc-related function and hold great significance for the development of a therapeutic reagent for malaria. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
Este estudo tem por objectivos determinar a Dose Glandular Média - Mean Glandular Dose (MGD) - em 3 sistemas de Mamografia e comparar os valores obtidos com os referenciais internacionais. O estudo foi realizado num sistema analógico de Écran-Película (EP) e em dois sistemas de imagem digital (CR e DR). Foi efectuado o cálculo da Entrance Surface Air Kerma (ESAK) e da MGD em três equipamentos a partir de uma amostra de dados referentes a 30 mulheres assintomáticas, com idades compreendidas entre os 40 e 64 anos. Em cada equipamento objecto de análise, foram recolhidos os dados referentes a 10 mulheres. Foram consideradas as projecções crânio-caudal (CC) e oblíqua médio-lateral (MLO). A análise de resultados revelou que o valor de MGD varia quando se compara os três sistemas. Nas incidências CC os valores de MGD obtidos foram de 1,54 mGy (EP), 1,78 mGy (CR) e 0,82 mGy (DR). Nas incidências MLO o valor de MGD foi de 1,53 mGy no sistema EP, de 1,78 mGy no CR e 0,87 mGy no sistema DR. Constata-se que o valor de MGD na incidência de CC é inferior ao valor de MGD na incidência MLO, excepto para o sistema EP. Verifica-se também que o sistema EP apresenta maior variabilidade nos dados de MGD comparativamente com os restantes sistemas. O sistema DR é o que apresenta a menor variabilidade de valores MGD e também valores de MGD mais baixos. Comparando os resultados deste estudo com as referências internacionais, verifica-se que a MGD se encontra abaixo do limite de 2 mGy recomendado. ABSTRACT - This study aims to estimate the Mean Glandular Dose (MGD) associated with three different mammographic systems and compare the results with recommended international reference values. The systems included in the study included a conventional Screen-Film (SF) system and two digital mammography systems (CR and DR). Entrance Surface Air Kerma (ESAK) and MGD associated with each equipment were calculated. A sample of 30 healthy women (age ranging from 40 to 64 years old) undertaking screening mammography was considered in this study. The mammographic exam includes two projections, cranio-caudal (CC) and medio-lateral oblique (MLO). The MGD results obtained for CC projection were 1,54 mGy (SF), 1,78 mGy (CR) and 0,82 mGy (DR). MGD values for the MLO projection were 1,53 mGy (SF), 1,78 mGy (CR) and 0,87 mGy (DR). Results show that MGD value is slightly lower in the CC projection than in MLO, except for the SF system (1,54 mGy; 1,53 mGy). In addition the MGD for the SF system varied more than that associated with the digital systems. The DR system allows a narrow variation of MGD values and also lower MGD values. Comparing this study results with the international references we concluded that MGD values are below the 2 mGy recommended value for the three systems evaluated.
Resumo:
Mestrado em Radiações Aplicadas às Tecnologias da Saúde. Área de especialização: Imagem Digital com Radiação X.
Resumo:
A microstructural analysis of silicon-on-insulator samples obtained by high dose oxygen ion implantation was performed by Raman scattering. The samples analyzed were obtained under different conditions thus leading to different concentrations of defects in the top Si layer. The samples were implanted with the surface covered with SiO2 capping layers of different thicknesses. The spectra measured from the as-implanted samples were fitted to a correlation length model taking into account the possible presence of stress effects in the spectra. This allowed quantification of both disorder effects, which are determined by structural defects, and residual stress in the top Si layer before annealing. These data were correlated to the density of dislocations remaining in the layer after annealing. The analysis performed corroborates the existence of two mechanisms that generate defects in the top Si layer that are related to surface conditions during implantation and the proximity of the top Si/buried oxide layer interface to the surface before annealing.
Resumo:
LRH and its agonists have been shown to exert both stimulatory and inhibitory effects on testicular function. In the present study, the dose and length of treatment were tested to determine the appearance of the stimulatory and inhibitory effects of LRH agonist on testicular axis including the three levels. Two doses of an agonist of LRH, 40 and 100 ng/100 g body weight (buserelin, 'agonist'), were administered daily for 1 to 15 days to adult male rats. Control rats received the vehicle only. On day 1, 2, 4, 8 and 15 of treatment, the pituitary, testicular and peripheral levels (weight of accessory sex organs and androgen receptors in ventral prostate) were tested 6 h after the last injection. For the 15 days of treatment with both doses, a stimulatory effect of the 'agonist' was observed on LH and FSH release. A short exposure (1-2 days) to the low dose of the 'agonist' had a stimulatory effect on the density of LH/hCG testicular receptors (326 +/- 49 vs control 185 +/- 21 fmol/mg protein, mean +/- SEM), on the weights of seminal vesicles and ventral prostate and exposure to both doses led to high plasma testosterone levels (13.8 +/- 0.5 and 13.7 +/- 0.7 ng/ml, respectively, vs control 2.6 +/- 0.3 ng/ml), and to an increased density of nuclear androgen receptors in the ventral prostate (142 +/- 9 and 144 +/- 15 fmol/mg protein respectively vs control 97 +/- 12 fmol/mg protein).(ABSTRACT TRUNCATED AT 250 WORDS)
Resumo:
The artificial dsRNA polyriboinosinic acid-polyribocytidylic acid, poly(I:C), is a potent adjuvant candidate for vaccination, as it strongly drives cell-mediated immunity. However, because of its effects on non-immune bystander cells, poly(I:C) administration may bear danger for the development of autoimmune diseases. Thus poly(I:C) should be applied in the lowest dose possible. We investigated microspheres carrying surface-assembled poly(I:C) as a two-in-one adjuvant formulation to stimulate maturation of monocyte-derived dendritic cells (MoDCs). Negatively charged polystyrene microspheres were equipped with a poly(ethylene glycol) corona through electrostatically driven surface assembly of a library of polycationic poly(l-lysine)-graft-poly(ethylene glycol) copolymers, PLL-g-PEG. Stable surface assembly of poly(I:C) was achieved by incubation of polymer-coated microspheres in an aqueous poly(I:C) solution. Surface-assembled poly(I:C) exhibited a strongly enhanced efficacy to stimulate maturation of MoDCs by up to two orders of magnitude, as compared to free poly(I:C). Multiple phagocytosis events were the key factor to enhance the efficacy. The cytokine secretion pattern of MoDCs after exposure to surface-assembled poly(I:C) differed from that of free poly(I:C), while their ability to stimulate T cell proliferation was similar. Overall, phagocytic signaling plays an important role in defining the resulting immune response to such two-in-one adjuvant formulations.
Resumo:
The optimization of most pesticide and fertilizer applications is based on overall grove conditions. In this work we measurements. Recently, Wei [9, 10] used a terrestrial propose a measurement system based on a ground laser scanner to LIDAR to measure tree height, width and volume developing estimate the volume of the trees and then extrapolate their foliage a set of experiments to evaluate the repeatability and surface in real-time. Tests with pear trees demonstrated that the accuracy of the measurements, obtaining a coefficient of relation between the volume and the foliage can be interpreted as variation of 5.4% and a relative error of 4.4% in the linear with a coefficient of correlation (R) of 0.81 and the foliar estimation of the volume but without real-time capabilities. surface can be estimated with an average error less than 5 %.
Resumo:
High-dose carbon-ion-implanted Si samples have been analyzed by infrared spectroscopy, Raman scattering, and x-ray photoelectron spectroscopy (XPS) correlated with transmission electron microscopy. Samples were implanted at room temperature and 500°C with doses between 1017 and 1018 C+/cm2. Some of the samples were implanted at room temperature with the surface covered by a capping oxide layer. Implanting at room temperature leads to the formation of a surface carbon-rich amorphous layer, in addition to the buried implanted layer. The dependence of this layer on the capping oxide suggests this layer to be determined by carbon migration toward the surface, rather than surface contamination. Implanting at 500°C, no carbon-rich surface layer is observed and the SiC buried layer is formed by crystalline ßSiC precipitates aligned with the Si matrix. The concentration of SiC in this region as measured by XPS is higher than for the room-temperature implantation.
Resumo:
Since the most characteristic feature of paraquat poisoning is lung damage, a prospective controlled study was performed on excised rat lungs in order to estimate the intensity of lesion after different doses. Twenty-five male, 2-3-month-old non-SPF Wistar rats, divided into 5 groups, received paraquat dichloride in a single intraperitoneal injection (0, 1, 5, 25, or 50 mg/kg body weight) 24 h before the experiment. Static pressure-volume (PV) curves were performed in air- and saline-filled lungs; an estimator of surface tension and tissue works was computed by integrating the area of both curves and reported as work/ml of volume displacement. Paraquat induced a dose-dependent increase of inspiratory surface tension work that reached a significant two-fold order of magnitude for 25 and 50 mg/kg body weight (P<0.05, ANOVA), sparing lung tissue. This kind of lesion was probably due to functional abnormalities of the surfactant system, as was shown by the increase in the hysteresis of the paraquat groups at the highest doses. Hence, paraquat poisoning provides a suitable model of acute lung injury with alveolar instability that can be easily used in experimental protocols of mechanical ventilation
Resumo:
Des efforts de recherche considérables ont été déployés afin d'améliorer les résultats de traitement de cancers pulmonaires. L'étude de la déformation de l'anatomie du patient causée par la ventilation pulmonaire est au coeur du processus de planification de traitement radio-oncologique. À l'aide d'images de tomodensitométrie quadridimensionnelles (4DCT), une simulation dosimétrique peut être calculée sur les 10 ensembles d'images du 4DCT. Une méthode doit être employée afin de recombiner la dose de radiation calculée sur les 10 anatomies représentant une phase du cycle respiratoire. L'utilisation de recalage déformable d'images (DIR), une méthode de traitement d'images numériques, génère neuf champs vectoriels de déformation permettant de rapporter neuf ensembles d'images sur un ensemble de référence correspondant habituellement à la phase d'expiration profonde du cycle respiratoire. L'objectif de ce projet est d'établir une méthode de génération de champs de déformation à l'aide de la DIR conjointement à une méthode de validation de leur précision. Pour y parvenir, une méthode de segmentation automatique basée sur la déformation surfacique de surface à été créée. Cet algorithme permet d'obtenir un champ de déformation surfacique qui décrit le mouvement de l'enveloppe pulmonaire. Une interpolation volumétrique est ensuite appliquée dans le volume pulmonaire afin d'approximer la déformation interne des poumons. Finalement, une représentation en graphe de la vascularisation interne du poumon a été développée afin de permettre la validation du champ de déformation. Chez 15 patients, une erreur de recouvrement volumique de 7.6 ± 2.5[%] / 6.8 ± 2.1[%] et une différence relative des volumes de 6.8 ± 2.4 [%] / 5.9 ± 1.9 [%] ont été calculées pour le poumon gauche et droit respectivement. Une distance symétrique moyenne 0.8 ± 0.2 [mm] / 0.8 ± 0.2 [mm], une distance symétrique moyenne quadratique de 1.2 ± 0.2 [mm] / 1.3 ± 0.3 [mm] et une distance symétrique maximale 7.7 ± 2.4 [mm] / 10.2 ± 5.2 [mm] ont aussi été calculées pour le poumon gauche et droit respectivement. Finalement, 320 ± 51 bifurcations ont été détectées dans le poumons droit d'un patient, soit 92 ± 10 et 228 ± 45 bifurcations dans la portion supérieure et inférieure respectivement. Nous avons été en mesure d'obtenir des champs de déformation nécessaires pour la recombinaison de dose lors de la planification de traitement radio-oncologique à l'aide de la méthode de déformation hiérarchique des surfaces. Nous avons été en mesure de détecter les bifurcations de la vascularisation pour la validation de ces champs de déformation.