840 resultados para Standardization Sample
Resumo:
The Abbott Cell-Dyn 3000 automated hematological analyzer prepares a histogram of platelet volume, which is measured by a technique using electrical impedance, inferring from its platelet count (PLT), mean platelet volume (MPV) and platelet distribution width (PDW). This equipment also calculates the plateletcrit (PCT). These platelet parameters may be important to evaluate platelet function, but they require standardization, because platelets swell when in contact with ethylenediaminetetra-acetic acid salts, hence an increase in blood sample storage time produces artificially increased results. To assess the effect of storage time on MPV, PLT, PDW and PCT, blood samples from 23 sickle cell anemia patients during steady state (Group I) and 50 from healthy controls (Group II) were placed in Vacutainer® tubes with dipotassium ethylenediaminetetra-acetic acid and measured over a period of 1440 minutes (24 h) at the following times: immediately after the venipuncture (time 0), 15, 30, 60, 120, 240, 360, 480 and 1440 minutes. The mean values of MPV and PCT were significantly increased (p<0.00001) along the storage time in both groups. The mean values of PLT and PDW were practically stable (p>0.05) throughout the storage time in both groups.
Resumo:
This work shows the potentiality of As as internal standard to compensate errors from sampling of sparkling drinking water samples in the determination of selenium by graphite furnace atomic absorption spectrometry. The mixture Pd(NO 3) 2/Mg(NO 3) 2 was used as chemical modifier. All samples and reference solutions were automatically spiked with 500 μg l -1 As and 0.2% (v/v) HNO 3 by the autosampler, eliminating the need for manual dilutions. For 10 μl dispensed sample into the graphite tube, a good correlation (r=0.9996) was obtained between the ratio of analyte absorbance by the internal standard absorbance and the analyte concentrations. The relative standard deviations (R.S.D.) of measurements varied from 0.05 to 2% and from 1.9 to 5% (n=12) with and without internal standardization, respectively. The limit of detection (LD) based on integrated absorbance was 3.0 μg l -1 Se. Recoveries in the 94-109% range for Se spiked samples were obtained. Internal standardization (IS) improved the repeatability of measurements and increased the lifetime of the graphite tube in ca. 15%. © 2004 Elsevier B.V. All rights reserved.
Resumo:
Urine proteomics is emerging as a powerful tool for biomarker discovery. The purpose of this study is the development of a well-characterized "real life" sample that can be used as reference standard in urine clinical proteomics studies.
Resumo:
Current data indicate that the size of high-density lipoprotein (HDL) may be considered an important marker for cardiovascular disease risk. We established reference values of mean HDL size and volume in an asymptomatic representative Brazilian population sample (n=590) and their associations with metabolic parameters by gender. Size and volume were determined in HDL isolated from plasma by polyethyleneglycol precipitation of apoB-containing lipoproteins and measured using the dynamic light scattering (DLS) technique. Although the gender and age distributions agreed with other studies, the mean HDL size reference value was slightly lower than in some other populations. Both HDL size and volume were influenced by gender and varied according to age. HDL size was associated with age and HDL-C (total population); non- white ethnicity and CETP inversely (females); HDL-C and PLTP mass (males). On the other hand, HDL volume was determined only by HDL-C (total population and in both genders) and by PLTP mass (males). The reference values for mean HDL size and volume using the DLS technique were established in an asymptomatic and representative Brazilian population sample, as well as their related metabolic factors. HDL-C was a major determinant of HDL size and volume, which were differently modulated in females and in males.
Resumo:
Context. A sample of 27 sources, cataloged as pre-main sequence stars by the Pico dos Dias Survey (PDS), is analyzed to investigate a possible contamination by post-AGB stars. The far-infrared excess due to dust present in the circumstellar envelope is typical of both categories: young stars and objects that have already left the main sequence and are suffering severe mass loss. Aims. The two known post-AGB stars in our sample inspired us to seek for other very likely or possible post-AGB objects among PDS sources previously suggested to be Herbig Ae/Be stars, by revisiting the observational database of this sample. Methods. In a comparative study with well known post-AGBs, several characteristics were evaluated: (i) parameters related to the circumstellar emission; (ii) spatial distribution to verify the background contribution from dark clouds; (iii) spectral features; and (iv) optical and infrared colors. Results. These characteristics suggest that seven objects of the studied sample are very likely post-AGBs, five are possible post-AGBs, eight are unlikely post-AGBs, and the nature of seven objects remains unclear.
Resumo:
Aims. Our goal is to study the physical properties of the circumstellar environment of young stellar objetcs (YSOs). In particular, the determination of the scattering mechanism can help us to constrain the optical depth of the disk and/or envelope in the near infrared. Methods. We used the IAGPOL imaging polarimeter along with the CamIV infrared camera at the LNA observatory to obtain near infrared polarimetry measurements in the H band of a sample of optically visible YSOs, namely, eleven T Tauri stars and eight Herbig Ae/Be stars. An independent determination of the disk (or jet) orientation was obtained for twelve objects from the literature. The circumstellar optical depth could then be estimated by comparing the integrated polarization position angle (PA) with the direction of the major axis of the disk projected onto the plane of the sky. Optically thin disks have, in general, a polarization PA that is perpendicular to the disk plane. In contrast, optically thick disks have polarization PAs parallel to the disks. Results. Among the T Tauri stars, three are consistent with having optically thin disks (AS 353A, RY Tau and UY Aur) and five with optically thick disks (V536 Aql, DG Tau, DO Tau, HL Tau and LkH alpha 358). Among the Herbig Ae/Be stars, two stars exhibit evidence of optically thin disks (Hen 3-1191 and VV Ser) and two of optically thick disks (PDS 453 and MWC 297). Our results seem consistent with optically thick disks at near infrared bands, which are more likely to be associated with younger YSOs. Marginal evidence of polarization reversal is found in RY Tau, RY Ori, WW Vul, and UY Aur. In the first three cases, this feature can be associated with the UXOR phenomenon. Correlations with the IRAS colors and the spectral index yielded evidence of an evolutionary segregation in which the disks tend to be optically thin when they are older.
Resumo:
Context. We study galaxy evolution and spatial patterns in the surroundings of a sample of 2dF groups. Aims. Our aim is to find evidence of galaxy evolution and clustering out to 10 times the virial radius of the groups and so redefine their properties according to the spatial patterns in the fields and relate them to galaxy evolution. Methods. Group members and interlopers were redefined after the identification of gaps in the redshift distribution. We then used exploratory spatial statistics based on the the second moment of the Ripley function to probe the anisotropy in the galaxy distribution around the groups. Results. We found an important anticorrelation between anisotropy around groups and the fraction of early-type galaxies in these fields. Our results illustrate how the dynamical state of galaxy groups can be ascertained by the systematic study of their neighborhoods. This is an important achievement, since the correct estimate of the extent to which galaxies are affected by the group environment and follow large-scale filamentary structure is relevant to understanding the process of galaxy clustering and evolution in the Universe.
Resumo:
For environmental quality assessment, INAA has been applied for determining chemical elements in small (200 mg) and large (200 g) samples of leaves from 200 trees. By applying the Ingamells` constant, the expected percent standard deviation was estimated in 0.9-2.2% for 200 mg samples. Otherwise, for composite samples (200 g), expected standard deviation varied from 0.5 to 10% in spite of analytical uncertainties ranging from 2 to 30%. Results thereby suggested the expression of the degree of representativeness as a source of uncertainty, contributing for increasing of the reliability of environmental studies mainly in the case of composite samples.
Resumo:
Soils are an important component in the biogeochemical cycle of carbon, storing about four times more carbon than biomass plants and nearly three times more than the atmosphere. Moreover, the carbon content is directly related on the capacity of water retention, fertility. among other properties. Thus, soil carbon quantification in field conditions is an important challenge related to carbon cycle and global climatic changes. Nowadays. Laser Induced Breakdown Spectroscopy (LIBS) can be used for qualitative elemental analyses without previous treatment of samples and the results are obtained quickly. New optical technologies made possible the portable LIBS systems and now, the great expectation is the development of methods that make possible quantitative measurements with LIBS. The goal of this work is to calibrate a portable LIBS system to carry out quantitative measures of carbon in whole tropical soil sample. For this, six samples from the Brazilian Cerrado region (Argisoil) were used. Tropical soils have large amounts of iron in their compositions, so the carbon line at 247.86 nm presents strong interference of this element (iron lines at 247.86 and 247.95). For this reason, in this work the carbon line at 193.03 nm was used. Using methods of statistical analysis as a simple linear regression, multivariate linear regression and cross-validation were possible to obtain correlation coefficients higher than 0.91. These results show the great potential of using portable LIBS systems for quantitative carbon measurements in tropical soils. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
The quality of environmental studies depends on the utilization of adequate sampling protocol and analytical method for obtaining reliable results and minimizing analytical uncertainties. In order to demonstrate the applicability of INAA for determining chemical element composition of invertebrates, this work evaluated sample representativeness in terms of subsampling and sample size. Br, Co, Fe, K, Na, Sc and Zn could be determined in very small samples despite increasing of analytical uncertainties. Special attention should be directed to invertebrate species with small structures because of the high chemical variation observed among different sample sizes tested.
Resumo:
PURPOSE: The aim of this study was to analyze the prevalence of urinary incontinence (UI) in a community sample from the city of Sao Paulo. METHODS: This epidemiological survey was conducted at a family health program in Sao Paulo, Brazil, using randomized sampling. Data were collected by interviewing residents and were analyzed by Pearson`s correlation coefficients, chi-square tests, and logistic regression analysis. RESULTS: Seventy (10.7%) of the 657 subjects currently presented UI, including 50.7% with sporadic UI and 74.3% with UI upon moderate efforts. Ninety-three percent woke up during the night, 43.7% maintained continence until the bathroom, 63.4% had a sensation of wetness, and 77.5% reported no use of any continence aids. Female gender, advanced age, gynecologic or urologic surgery, dysuria, and urinary tract infection were correlated with UI (P < .001; r(2) = 0.572). CONCLUSION: The overall prevalence of UI was found to be high and was comparable to results from multiple countries.