927 resultados para Standard costing
Resumo:
A compact frequency standard based on an expanding cold (133)CS cloud is under development in our laboratory. In a first experiment, Cs cold atoms were prepared by a magneto-optical trap in a vapor cell, and a microwave antenna was used to transmit the radiation for the clock transition. The signal obtained from fluorescence of the expanding cold atoms cloud is used to lock a microwave chain. In this way the overall system stability is evaluated. A theoretical model based on a two-level system interacting with the two microwave pulses enables interpretation for the observed features, especially the poor Ramsey fringes contrast. (C) 2008 Optical Society of America.
Resumo:
In this work we investigate the duality linking standard and tachyon scalar field homogeneous and isotropic cosmologies in N + 1 dimensions. We determine the transformation between standard and tachyon scalar fields and between their associated potentials, corresponding to the same background evolution. We show that, in general, the duality is broken at a perturbative level, when deviations from a homogeneous and isotropic background are taken into account. However, we find that for slow-rolling fields the duality is still preserved at a linear level. We illustrate our results with specific examples of cosmological relevance, where the correspondence between scalar and tachyon scalar field models can be calculated explicitly.
Resumo:
We study the massless scalar, Dirac, and electromagnetic fields propagating on a 4D-brane, which is embedded in higher-dimensional Gauss-Bonnet space-time. We calculate, in the time domain, the fundamental quasinormal modes of a spherically symmetric black hole for such fields. Using WKB approximation we study quasinormal modes in the large multipole limit. We observe also a universal behavior, independent on a field and value of the Gauss-Bonnet parameter, at an asymptotically late time.
Resumo:
An analytical procedure for multiple standard additions of arsenic species using sequential injection analysis (SIA) is proposed for their quantification in seafood extracts. SIA presented flexibility for generating multiple specie standards at the ng mL(-1) concentration level by adding different volumes of As(III), As(V), monomethylarsonic (MMA) and dimethylarsinic (DMA) to the sample. The mixed sample plus standard solutions were delivered from SIA to fill the HPLC injection loop. Subsequently, As species were separated by HPLC and analyzed by atomic fluorescence spectrometry (AFS). The proposed system comprised two independently controlled modules, with the HPLC loop acting as the intermediary device. The analytical frequency was enhanced by combining the actions of both modules. While the added sample was flowing through the chromatographic column towards the detection system, the SIA program started performing the standard additions to another sample. The proposed method was applied to spoiled seafood extracts. Detection limits based on 3 sigma for As(III), As(V), MMA and DMA were 0.023, 0.39, 0.45 and 1.0 ng mL(-1), respectively. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Background: Although the Clock Drawing Test (CDT) is the second most used test in the world for the screening of dementia, there is still debate over its sensitivity specificity, application and interpretation in dementia diagnosis. This study has three main aims: to evaluate the sensitivity and specificity of the CDT in a sample composed of older adults with Alzheimer`s disease (AD) and normal controls; to compare CDT accuracy to the that of the Mini-mental State Examination (MMSE) and the Cambridge Cognitive Examination (CAMCOG), and to test whether the association of the MMSE with the CDT leads to higher or comparable accuracy as that reported for the CAMCOG. Methods: Cross-sectional assessment was carried out for 121 AD and 99 elderly controls with heterogeneous educational levels from a geriatric outpatient clinic who completed the Cambridge Examination for Mental Disorder of the Elderly (CAMDEX). The CDT was evaluated according to the Shulman, Mendez and Sunderland scales. Results: The CDT showed high sensitivity and specificity. There were significant correlations between the CDT and the MMSE (0.700-0.730; p < 0.001) and between the CDT and the CAMCOG (0.753-0.779; p < 0.001). The combination of the CDT with the MMSE improved sensitivity and specificity (SE = 89.2-90%; SP = 71.7-79.8%). Subgroup analysis indicated that for elderly people with lower education, sensitivity and specificity were both adequate and high. Conclusions: The CDT is a robust screening test when compared with the MMSE or the CAMCOG, independent of the scale used for its interpretation. The combination with the MMSE improves its performance significantly, becoming equivalent to the CAMCOG.
Resumo:
A Thermodynamic air-standard cycle was envisaged for Ranque-Hilsh (R-H) or Vortex Tubes to provide relevant Thermodynamic analysis and tools for setting operating limits according to the conservation laws of mass and energy, as well as the constraint of the Second Law of Thermodynamics. The study used an integral or control volume approach and resulted in establishing working equations for evaluating the performance of an R-H tube. The work proved that the coefficient of performance does not depend on the R-H tube operating mode, i.e., the same value is obtained independently if the R-H tube operates either as a heat pump or as a refrigeration device. It was also shown that the isentropic coefficient of performance displays optima values of cold and hot mass fractions for a given operating pressure ratio. Finally, the study was concluded by comparing the present analysis with some experimental data available in the literature for operating pressures ranging 2-11 atm. (C) 2010 Elsevier Ltd and IIR. All rights reserved.
Resumo:
This work shows a comparison between the analog performance of standard and strained Si n-type triple-gate FinFETs with high-K dielectrics and TiN gate material. Different channel lengths and fin widths are studied. It is demonstrated that both standard and strained FinFETs with short channel length and narrow fins have similar analog properties, whereas the increase of the channel length degrades the early voltage of the strained devices, consequently decreasing the device intrinsic voltage gain with respect to standard ones. Narrow strained FinFETs with long channel show a degradation of the Early voltage if compared to standard ones suggesting that strained devices are more subjected to the channel length modulation effect. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
In stored grains, smaller depositions and great variation with respect to theoretical insecticide doses are frequently found. The objective of this work was to study the effectiveness of the standard method (ISO 5682/1-1996) employed to evaluate hydraulic nozzles used in stored corn and wheat grain protection experiments. The transversal volumetric distribution and droplet spectrum of a model TJ-60 8002EVS nozzle were determined in order to calibrate a spraying system for an application rate of 5 L/t and to obtain theoretical concentrations of 10 and 0.5 mg/kg of fenitrothion and esfenvalerate, respectively. After treatment, the corn and wheat grains were processed and deposition was analyzed by gas chromatography. The type of grain did not have any influence on insecticide deposition and was dependent upon insecticide only. The insecticide deposits on the grains only reached 42.1 and 38.2% of the intended theoretical values for fenitrothion and esfenvalerate concentrations, respectively. These results demonstrate the ineffectiveness of the standard evaluation method for hydraulic nozzles employed in stored grain protection experiments.
Resumo:
As seen from street.
Resumo:
Hand-drawn plan and elevation.
Resumo:
Objective: To determine the effect of an early intervention program in an acute care setting on the length of stay in hospital of elderly patients with proximal femoral fractures. Setting: Acute orthopaedic ward of a large teaching hospital. Design and Participants: A randomised controlled trial comparing 38 intervention patients with 33 Standard Care patients. Intervention: Early surgery, minimal narcotic analgesia, intense daily therapy and close monitoring of patient needs via a multidisciplinary approach versus routine hospital management. Main outcome measures: Length of stay (LOS); deaths; level of independent functioning. Results: Mean LOS was shorter in the Intervention group than in the Standard Care group (21 days v. 32.5 days; P<0.01). After adjusting for other factors that could affect LOS (e.g. age, sex, pre-trauma functional levels, pre-trauma comorbidity and postsurgical complications), the Intervention program was significantly predictive of shorter LOS (P=0.01). The Intervention group did not experience greater numbers of deaths, deterioration in function or need for social support than the Standard Care group. Conclusion: This early intervention program in an acute care setting results in significantly shorter length of hospital stay for elderly patients with femoral fractures.
Resumo:
Background: Concerns exist regarding the effect of radiation dose from paediatric pelvic CT scans and the potential later risk of radiation-induced neoplasm and teratogenic outcomes in these patients. Objective: To assess the diagnostic quality of CT images of the paediatric pelvis using either reduced mAs or increased pitch compared with standard settings. Materials and methods: A prospective study of pelvic CT scans of 105 paediatric patients was performed using one of three protocols: (1) 31 at a standard protocol of 200 mA with rotation time of 0.75 s at 120 kVp and a pitch factor approximating 1.4; (2) 31 at increased pitch factor approaching 2 and 200 mA; and (3) 43 at a reduced setting of 100 mA and a pitch factor of 1.4. All other settings remained the same in all three groups. Image quality was assessed by radiologists blinded to the protocol used in each scan. Results: No significant difference was found between the quality of images acquired at standard settings and those acquired at half the standard mAs. The use of increased pitch factor resulted in a higher proportion of poor images. Conclusions: Images acquired at 120 kVp using 75 mAs are equivalent in diagnostic quality to those acquired at 150 mAs. Reduced settings can provide useful imaging of the paediatric pelvis and should be considered as a standard protocol in these situations.
Resumo:
Objective. To assess the impact that the Brazilian Standard for Marketing of Baby Food (Norma Brasileira de Comercializacao de Alimentos para Lactentes) have had on breastfeeding rates and regulating the marketing of breast-milk substitutes. Methods. Data were retrieved from a national survey conducted in 2000 that administered structured questionnaires to nine different groups. A total of 2 848 surveys were completed. Cluster sampling was employed to randomly select a sample from 159 towns located in the 26 Brazilian states and the Federal District. Results. The survey showed that participants possess satisfactory knowledge regarding the importance of breastfeeding and its ideal duration period. During the past two decades, the median duration of breastfeeding has increased, but it is still below desired levels. The mother`s return to work, maternal health issues, perception of insufficient breast milk, and information provided by health professionals were among reasons given for early termination of breastfeeding. Knowledge of the Brazilian standard was very limited, even among health professionals. Conclusions. Breastfeeding promotion in Brazil should focus on overcoming the cultural, educational, and economic barriers identified from among the various groups assessed. Interagency cooperation should include public, private, and third-parties, and focus on disseminating breastfeeding information and promoting the desirability of breastfeeding. Barriers to cooperation should be tackled in order to ensure that the main goal of the Brazilian standard-protection of infant health-can be achieved.
Resumo:
Background: There is a paucity of information describing the real-time 3-dimensional echocardiography (RT3DE) and dyssynchrony indexes (DIs) of a normal population. We evaluate the RT3DE DIs in a population with normal electrocardiograms and 2- and 3-dimensional echocardiographic analyses. This information is relevant for cardiac resynchronization therapy. Methods: We evaluated 131 healthy volunteers (73 were male, aged 46 +/- 14 years) who were referred for routine echocardiography; who presented normal cardiac structure on electrocardiography, 2-dimensional echocardiography, and RT3DE; and who had no history of cardiac diseases. We analyzed 3-dimensional left ventricular ejection fraction, left ventricle end-diastolic volume, left ventricle end-systolic volume, and left ventricular systolic DI% (6-, 12-, and 16-segment models). RT3DE data were analyzed by quantifying the statistical distribution (mean, median, standard deviation [SD], relative SD, coefficient of skewness, coefficient of kurtosis, Kolmogorov-Smirnov test, D`Agostino-Pearson test, percentiles, and 95% confidence interval). Results: Left ventricular ejection fraction ranged from 50% to 80% (66.1% +/- 7.1%); left ventricle end-diastolic volume ranged from 39.8 to 145 mL (79.1 +/- 24.9 mL); left ventricle end-systolic volume ranged from 12.9 to 66 mL (27 +/- 12.1 mL); 6-segment DI% ranged from 0.20% to 3.80% (1.21% +/- 0.66%), median: 1.06, relative SD: 0.5482, coefficient of skewness: 1.2620 (P < .0001), coefficient of Kurtosis: 1.9956 (P = .0039); percentile 2.5%: 0.2900, percentile 97.5%: 2.8300; 12-segment DI% ranged from 0.22% to 4.01% (1.29% +/- 0.71%), median: 1.14, relative SD: 0.95, coefficient of skewness: 1.1089 (P < .0001), coefficient of Kurtosis: 1.6372 (P = .0100), percentile 2.5%: 0.2850, percentile 97.5%: 3.0700; and 16-segment DI% ranged from 0.29% to 4.88% (1.59 +/- 0.99), median: 1.39, relative SD: 0.56, coefficient of skewness: 1.0792 (P < .0001), coefficient of Kurtosis: 0.9248 (P = .07), percentile 2.5%: 0.3750, percentile 97.5%: 3.750. Conclusion: This study allows for the quantification of RT3DE DIs in normal subjects, providing a comparison for patients with heart failure who may be candidates for cardiac resynchronization therapy. (J Am Soc Echocardiogr 2008; 21: 1229-1235)