905 resultados para Skype screen shots
Resumo:
This study investigated the sensitivity of information processing, recall and orientation tasks to the presence of mild Traumatic Brain Injury (mTBI). Fifty-six (40 male, 16 female) mTBI patients and 85 (57 male and 28 female) controls with orthopaedic injuries were tested within 24 hr of injury in the Department of Emergency Medicine. mTBI patients answered fewer orientation questions and recalled fewer words in delayed recall than orthopaedic patients. mTBI patients judged fewer sentences in 2 min than orthopaedic controls, and female mTBI patients judged fewer sentences than male mTBI patients. Male mTBI patients correctly recalled fewer words during immediate memory and learning than female mTBI patients and orthopaedic controls. Those mTBI patients with a history of previous head injuries did not perform more poorly than those mTBI patients without previous head injuries. These results indicate that tests of speed of information processing, word learning and orientation questions are sensitive to the acute effects of mTBI.
Resumo:
Background: The Western Ontario and McMaster Universities (WOMAC) Osteoarthritis Index is a previously described self-administered questionnaire covering three domains: pain, stiffness and function. It has been validated in patients with osteoarthritis (OA) of the hip or knee in a paper-based format. Aim: To validate the WOMAC 3.0 using a numerical rating scale in a computerized touch screen format allowing immediate evaluation of the questionnaire. In the computed version cartoons, written and audio instruments were included in order facilitate application. Methods: Fifty patients, demographically balanced, with radiographically proven primary hip or knee OA completed the classical paper and the new computerized WOMAC version. Subjects were randomized either to paper format or computerized format first to balance possible order effects, Results: The intra-class correlation coefficients for pain, stiffness and function values were 0.915, 0.745 and 0.940, respectively. The Spearman correlation coefficients for pain, stiffness and function were 0.88, 0.77 and 0.87, respectively. Conclusion: These data indicate that the computerized WOMAC OA index 3.0 is comparable to the paper WOMAC in all three dimensions. The computerized version would allow physicians to get an immediate result and if present a direct comparison with a previous exam. (C) 2002 OsteoArthritis Research Society International. Published by Elsevier Science Ltd. All rights reserved.
Resumo:
Using a subtractive hybridisation approach, we enriched for genes likely to play a role in embryonic development of the mammalian face and other structures. This was achieved by subtracting cDNA derived from adult mouse liver from that derived from 10.5 dpc mouse embryonic branchial arches 1 and 2. Random sequencing of clones from the resultant library revealed that a high percentage correspond to genes with a previously established role in embryonic development and disease, while 15% represent novel or uncharacterised genes. Whole mount in situ hybridisation analysis of novel genes revealed that approximately 50% have restricted expression during embryonic development. In addition to expression in branchial arches, these genes showed a range of expression domains commonly including neural tube and somites. Notably, all genes analysed were found to be expressed not only in the branchial arches but also in the developing limb buds, providing support for the hypothesis that development of the limbs and face is likely to involve analogous molecular processes. (C) 2003 Wiley-Liss, Inc.
Resumo:
This article reports on a-Si:H-based low-leakage blue-enhanced photodiodes for dual-screen x-ray imaging detectors. Doped nanocrystalline silicon was incorporated in both the n- and p-type regions to reduce absorption losses for light incoming from the top and bottom screens. The photodiode exhibits a dark current density of 900 pA/cm(2) and an external quantum efficiency up to 90% at a reverse bias of 5 V. In the case of illumination through the tailored p-layer, the quantum efficiency of 60% at a 400 nm wavelength is almost double that for the conventional a-Si:H n-i-p photodiode.
Resumo:
INTRODUÇÃO: Programas de investigação epidemiológica e de ação no âmbito da violência familiar estão em franca ascensão, requerendo instrumentos de aferição adaptados e vertidos para o português. O objetivo do estudo é avaliar a equivalência semântica entre o original em inglês e duas versões para o português do instrumento Abuse Assessment Screen (AAS) usado no rastreamento de casos de violência contra a mulher grávida e recomendar uma versão-síntese para uso corrente. MÉTODOS: O processo de avaliação de equivalência semântica envolveu quatro etapas: tradução, retradução, apreciação formal de equivalência e crítica final através de consultas com especialista na área temática. RESULTADOS: Para cada item do instrumento apresentam-se os resultados relativos às quatro etapas. O texto cobre cada passo do processo que levou à versão final. As duas versões mostraram-se bastante semelhantes, com 14 das 15 assertivas similares, embora a segunda versão tenha se mostrado mais adequada, ainda que para alguns itens tenha sido decidido juntar as duas versões ou mesmo utilizar um item oriundo da versão um. CONCLUSÃO: É importante usar mais de uma versão no processo, em várias etapas de avaliação e de crítica, e discutir a pertinência de se acrescentar uma etapa adicional de interlocução do instrumento com membros da população-alvo.
Resumo:
Celiac disease is a gluten-induced autoimmune enteropathy characterized by the presence of tissue tranglutaminase (tTG) autoantibodies. A disposable electrochemical immunosensor (EI) for the detection of IgA and IgG type anti-tTG autoantibodies in real patient’s samples is presented. Screen-printed carbon electrodes (SPCE) nanostructurized with carbon nanotubes and gold nanoparticles were used as the transducer surface. This transducer exhibits the excellent characteristics of carbon–metal nanoparticle hybrid conjugation and led to the amplification of the immunological interaction. The immunosensing strategy consisted of the immobilization of tTG on the nanostructured electrode surface followed by the electrochemical detection of the autoantibodies present in the samples using an alkaline phosphatase (AP) labelled anti-human IgA or IgG antibody. The analytical signal was based on the anodic redissolution of enzymatically generated silver by cyclic voltammetry. The results obtained were corroborated with a commercial ELISA kit indicating that the electrochemical immunosensor is a trustful analytical screening tool.
Resumo:
Bacterial food poisoning is an ever-present threat that can be prevented with proper care and handling of food products. A disposable electrochemical immunosensor for the simultaneous measurements of common food pathogenic bacteria namely Escherichia coli O157:H7 (E. coli), campylobacter and salmonella were developed. The immunosensor was fabricated by immobilizing the mixture of anti-E. coli, anticampylobacter and anti-salmonella antibodies with a ratio of 1:1:1 on the surface of the multiwall carbon nanotube-polyallylamine modified screen printed electrode (MWCNT-PAH/SPE). Bacteria suspension became attached to the immobilized antibodies when the immunosensor was incubated in liquid samples. The sandwich immunoassay was performed with three antibodies conjugated with specific nanocrystal ( -E. coli-CdS, -campylobacter-PbS and -salmonella-CuS) which has releasable metal ions for electrochemical measurements. The square wave anodic stripping voltammetry (SWASV) was employed to measure released metal ions from bound antibody nanocrystal conjugates. The calibration curves for three selected bacteria were found in the range of 1 × 103 – 5 × 105 cells mL−1 with the limit of detection (LOD) 400 cells mL−1 for salmonella, 400 cells mL−1 for campylobacter and 800 cells mL−1 for E. coli. The precision and sensitivity of this method show the feasibility of multiplexed determination of bacteria in milk samples.
Resumo:
The electrooxidative behavior of pravastatin (PRV) in aqueous media was studied by square-wave voltammetry at a glassycarbon electrode (GCE) and at a screen-printed carbon electrode (SPCE). Maximum peak current intensities in a pH 5.0 buffer were obtained at +1.3 V vs. AgCl/Ag and +1.0 V vs. Ag for the GCE and SPCE surface respectively. Validation of the developed methodologies revealed good performance characteristics and confirmed their applicability to the quantification of PRV in pharmaceutical products, without significant sample pretreatment. A comparative analysis between the two electrode types showed that SPCEs are preferred as an electrode surface because of their higher sensitivity and the elimination of the need to clean the electrode’s surface for its renewal, which frequently is, if not always, the rate-limiting step in voltammetric analysis.
Resumo:
This essay aims to confront the literary text Wuthering Heights by Emily Brontë with five of its screen adaptations and Portuguese subtitles. Owing to the scope of the study, it will necessarily afford merely a bird‘s eye view of the issues and serve as a starting point for further research. Accordingly, the following questions are used as guidelines: What transformations occur in the process of adapting the original text to the screen? Do subtitles update the film dialogues to the target audience‘s cultural and linguistic context? Are subtitles influenced more by oral speech than by written literary discourse? Shouldn‘t subtitles in fact reflect the poetic function prevalent in screen adaptations of literary texts? Rather than attempt to answer these questions, we focus on the objects as phenomena. Our interdisciplinary undertaking clearly involves a semio-pragmatic stance, at this stage trying to avoid theoretical backdrops that may affect our apprehension of the objects as to their qualities, singularities, and conventional traits, based on Lucia Santaella‘s interpretation of Charles S. Peirce‘s phaneroscopy. From an empirical standpoint, we gather features and describe peculiarities, under the presumption that there are substrata in subtitling that point or should point to the literary source text, albeit through the mediation of a film script and a particular cinematic style. Therefore, we consider how the subtitling process may be influenced by the literary intertext, the idiosyncrasies of a particular film adaptation, as well as the socio-cultural context of the subtitler and target audience. First, we isolate one of the novel‘s most poignant scenes – ‗I am Heathcliff‘ – taking into account its symbolic play and significance in relation to character and plot construction. Secondly, we study American, English, French, and Mexican adaptations of the excerpt into film in terms of intersemiotic transformations. Then we analyze differences between the film dialogues and their Portuguese subtitles.
Resumo:
Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Tradução e Interpretação Especializadas, sob orientação da doutora Clara Sarmento Esta versão não contém as críticas e sugestões dos elementos do júri
Resumo:
As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.
Resumo:
XIX Meeting of the Portuguese Electrochemical Society - XVI Iberic Meeting of Electrochemistry
Resumo:
Human chorionic gonadotropin (hCG) is a key diagnostic marker of pregnancy and an important biomarker for cancers in the prostate, ovaries and bladder and therefore of great importance in diagnosis. For this purpose, a new immunosensor of screen-printed electrodes (SPEs) is presented here. The device was fabricated by introducing a polyaniline (PANI) conductive layer, via in situ electropolymerization of aniline, onto a screen-printed graphene support. The PANI-coated graphene acts as the working electrode of a three terminal electrochemical sensor. The working electrode is functionalised with anti-hCG, by means of a simple process that enabled oriented antibody binding to the PANI layer. The antibody was attached to PANI following activation of the –COOH group at the Fc terminal. Functionalisation of the electrode was analysed and optimized using Electrochemical Impedance Spectroscopy (EIS). Chemical modification of the surface was characterised using Fourier transform infrared, and Raman spectroscopy with confocal microscopy. The graphene–SPE–PANI devices displayed linear responses to hCG in EIS assays from 0.001 to 50 ng mL−1 in real urine, with a detection limit of 0.286 pg mL−1. High selectivity was observed with respect to the presence of the constituent components of urine (urea, creatinine, magnesium chloride, calcium chloride, sodium dihydrogen phosphate, ammonium chloride, potassium sulphate and sodium chloride) at their normal levels, with a negligible sensor response to these chemicals. Successful detection of hCG was also achieved in spiked samples of real urine from a pregnant woman. The immunosensor developed is a promising tool for point-of-care detection of hCG, due to its excellent detection capability, simplicity of fabrication, low-cost, high sensitivity and selectivity.
Resumo:
A gold screen printed electrode (Au-SPE) was modified by merging Molecular Imprinting and Self-Assembly Monolayer techniques for fast screening cardiac biomarkers in point-of-care (POC). For this purpose, Myoglobin (Myo) was selected as target analyte and its plastic antibody imprinted over a glutaraldehyde (Glu)/cysteamine (Cys) layer on the gold-surface. The imprinting effect was produced by growing a reticulated polymer of acrylamide (AAM) and N,N′-methylenebisacrylamide (NNMBA) around the Myo template, covalently attached to the biosensing surface. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were carried out in all chemical modification steps to confirm the surface changes in the Au-SPE. The analytical features of the resulting biosensor were studied by different electrochemical techniques, including EIS, square wave voltammetry (SWV) and potentiometry. The limits of detection ranged from 0.13 to 8 μg/mL. Only potentiometry assays showed limits of detection including the cut-off Myo levels. Quantitative information was also produced for Myo concentrations ≥0.2 μg/mL. The linear response of the biosensing device showed an anionic slope of ~70 mV per decade molar concentration up to 0.3 μg/mL. The interference of coexisting species was tested and good selectivity was observed. The biosensor was successfully applied to biological fluids.