43 resultados para Resurfacing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The mosaic novel - with its independent 'story-tiles' linking together to form a complete narrative - has the potential to act as a reflection on the periodic resurfacing of unconscious memories in the conscious lives of fictional characters. This project is an exploration of the mosaic text as a fictional analogue of involuntary memory. These concepts are investigated as they appear in traditional fairy tales and engaged with in this thesis's creative component, Sourdough and Other Stories (approximately 80,000 words), a mosaic novel comprising sixteen interconnected 'story-tiles'. Traditional fairy tales are non-reflective and conducive to forgetting (i.e. anti-memory); fairy tale characters are frequently portrayed as psychologically two-dimensional, in that there is no examination of the mental and emotional distress caused when children are stolen/ abandoned/ lost and when adults are exiled. Sourdough and Other Stories is a creative examination of, and attempted to remedy, this lack of psychological depth. This creative work is at once something more than a short story collection, and something that is not a traditional novel, but instead a culmination of two modes of writing. It employs the fairy tale form to explore James' 'thorns in the spirit' (1898, p.199) in fiction; the anxiety caused by separation from familial and community groups. The exegesis, A Story Told in Parts - Sourdough and Other Stories is a critical essay (approximately 20,000 words in length), a companion piece to the mosaic novel, which analyses how my research question proceeded from my creative work, and considers the theoretical underpinnings of the creative work and how it enacts the research question: 'Can a writer use the structural possibilities of the mosaic text to create a fictional work that is an analogue of an involuntary memory?' The cumulative effect of the creative and exegetical works should be that of a dialogue between the two components - each text informing the other and providing alternate but complementary lenses with which to view the research question.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the rising popularity of anime amongst animation students, audiences and scholars around the world, it has become increasingly important to critically analyse anime as being more than a ‘limited’ form of animation, and thematically as encompassing more than super robots and pocket monsters. Frames of Anime: Culture and Image-Building charts the development of Japanese animation from its indigenous roots within a native culture, through Japan’s experience of modernity and the impact of the Second World War. This text is the result of a rigorous study that recognises the heterogeneous and polymorphous background of anime. As such, Tze-Yue has adopted an ‘interdisciplinary and transnational’ (p. 7) approach to her enquiry, drawing upon face-to-face interviews, on-site visits and biographical writings of animators. Tze-Yue delineates anime from other forms of animation by linking its visual style to pre-modern Japanese art forms and demonstrating the connection it shares with an indigenous folk system of beliefs. Via the identification of traditional Japanese art forms and their visual connectedness to Japanese animation, Tze-Yue shows that the Japanese were already heavily engaged in what was destined to become anime once technology had enabled its production. Tze-Yue’s efforts to connect traditional Japanese art forms, and their artistic elements, to contemporary anime reveals that the Japanese already had a rich culture of visual storytelling that pre-dates modern animation. She identifies the Japanese form of the magic lantern at the turn of the 19th century, utsushi-e, as the pre-modern ancestor of Japanese animation, describing it as ‘Edo anime’ (p. 43). Along with utsushi-e, the Edo period also saw the woodblock print, ukiyo-e, being produced for the rising middle class (p. 32). Highlighting the ‘resurfacing’ of ‘realist’ approaches to Japanese art in ukiyo-e, Tze-Yue demonstrates the visual connection of ukiyo-e and anime in the …

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study determined the rate and indication for revision between cemented, uncemented, hybrid and resurfacing groups from NJR (6 th edition) data. Data validity was determined by interrogating for episodes of misclassification. We identified 6,034 (2.7%) misclassified episodes, containing 97 (4.3%) revisions. Kaplan-Meier revision rates at 3 years were 0.9% cemented, 1.9% for uncemented, 1.2% for hybrids and 3.0% for resurfacings (significant difference across all groups, p<0.001, with identical pattern in patients <55 years). Regression analysis indicated both prosthesis group and age significantly influenced failure (p<0.001). Revision for pain, aseptic loosening, and malalignment were highest in uncemented and resurfacing arthroplasty. Revision for dislocation was highest in uncemented hips (significant difference between groups, p<0.001). Feedback to the NJR on data misclassification has been made for future analysis. © 2012 Wichtig Editore.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Because of the limited availability of donor cartilage for resurfacing defects in articular surfaces, there is tremendous interest in the in vitro bioengineering of cartilage replacements for clinical applications. However, attaining mechanical properties in engineered cartilaginous constructs that approach those of native cartilage has not been previously achieved when constructs are cultured under free-swelling conditions. One approach toward stimulating the development of constructs that are mechanically more robust is to expose them to physical environments that are similar, in certain ways, to those encountered by native cartilage. This is a strategy motivated by observations in numerous short-term experiments that certain mechanical signals are potent stimulators of cartilage metabolism. On the other hand, excess mechanical loading can have a deleterious effect on cartilage. Culture conditions that include a physical stimulation component are made possible by the use of specialized bioreactors. This chapter addresses some of the issues involved in using bioreactors as integral components of cartilage tissue engineering and in studying the physical regulation of cartilage. We first consider the generation of cartilaginous constructs in vitro. Next we describe the rationale and design of bioreactors that can impart either mechanical deformation or fluid-induced mechanical signals.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ce mémoire présente l’évaluation du remodelage osseux autour des composantes acétabulaires non cimentées press-fit d’une arthroplastie de resurfaçage (RH) et d’une prothèse totale de hanche (PTH) après un minimum de 21 mois d’implantation. Nous avons mesuré par l’absorptiométrie à rayons X en double énergie (DEXA) la densité minérale osseuse (DMO) supra acétabulaire chez 60 patients (44 RH, 16 PTH). Aucune différence significative de la moyenne des DMO au niveau de la zone globale et de la zone centrale de l’acétabulum n’a été trouvée entre la hanche opérée et la hanche controlatérale, dans les deux groupes de traitement. Cependant, la DMO des zones corticospongieuses médiale et latérale est plus élevée du côté opéré par rapport au côté non opéré avec la cupule en chrome cobalt de la RH; (p=0,014 et 0,031 respectivement). Alors que pour la PTH avec une cupule en titane, la différence de la DMO au niveau de ces zones n’est pas significative; (p=0,130 et 0,733). Ces données semblent démontrer qu’avec des cupules plus rigides, il y a transfert des contraintes de charges vers la périphérie corticale. C’est la première étude à évaluer le remodelage osseux péri acétabulaire avec un RH. Cela montre que la DMO est relativement préservée et que le transfert des contraintes vers la périphérie peut être favorable au maintien de la stabilité de l’implant primaire et aux éventuelles révisions de la cupule press-fit du RH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Depuis les dernières années, la prévalence de personnes souffrant de dégénérescence des cartilages articulaires, communément appelée ostéoarthrite (OA), ne cesse d’augmenter. Les douleurs articulaires et les raideurs musculaires associées à cette pathologie mènent à des limitations des capacités fonctionnelles, à une perte de mobilité et d’autonomie affectant grandement la qualité de vie de ces personnes. Afin de soulager les personnes souffrant de cette pathologie, l’arthroplastie de la hanche est une procédure chirurgicale fréquemment utilisée. À la suite de cette chirurgie, une amélioration de la qualité de vie et une reprise des capacités fonctionnelles sont souvent observées. Cependant, comparativement à des sujets sains, la vitesse de marche est diminuée, une faiblesse des muscles abducteurs de la hanche est constatée et des mouvements compensatoires au niveau du tronc sont persistants. L’objectif de cette thèse est d’évaluer le patron locomoteur chez des patients qui subiront une arthroplastie de la hanche. Plus spécifiquement, les adaptations locomotrices pré et post-opératoires seront quantifiées dans le but d’apporter des modifications aux programmes de réhabilitation pour ainsi favoriser un patron locomoteur sans déficit. Afin de répondre à cet objectif, trois études distinctes ont été effectuées. Dans le cadre de la première étude, l’impact de l’implantation d’une prothèse totale de la hanche avec une tête fémorale de large diamètre et une prothèse de resurfaçage a été évalué par rapport aux sujets sains lors de la locomotion. Au cours de cette étude, le contrôle du tronc a été analysé en utilisant la distance entre le centre de masse corporel et le centre articulaire de la hanche opérée. Suite aux résultats obtenus, aucune différence majeure n’existe entre les deux types de prothèses en ce qui a trait au contrôle du tronc et ce, à un an post-opératoire. Lors de la deuxième étude, la symétrie des paramètres biomécaniques des membres inférieurs lors de la locomotion chez des patients ayant bénéficié de l’implantation d’une prothèse de la hanche a été caractérisée suite à un programme d’exercices péri-opératoires (pré et post-opératoire). Lors de cette étude, le programme d’exercices péri-opératoires était complémentaire au protocole de réadaptation du centre hospitalier. D’après les résultats obtenus lors de cette étude exploratoire, ce programme d’exercices péri-opératoires semble permettre d’améliorer la symétrie de la puissance et du travail musculaire au niveau de la hanche, du genou et de la cheville favorisant ainsi un patron de marche avec de minimes compensations. Finalement, dans le cadre de la troisième étude, l’approche prédictive et l’approche fonctionnelle, utilisées pour localiser le centre articulaire de la hanche, ont été comparées aux mesures radiographiques, chez des patients à la suite d’un remplacement articulaire de la hanche. À la suite de cette étude, les résultats démontrent que l’utilisation de l’approche fonctionnelle est plus appropriée chez des patients ayant bénéficié d’une arthroplastie de la hanche. En effet, cette approche individualisée est plus précise ce qui, par conséquent, permettra d’obtenir des résultats de plus grande qualité lors d’analyses biomécaniques de la locomotion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La dégénérescence articulaire sévère de la hanche est une pathologie fréquente et son traitement ultime est le remplacement prothétique. L’arthroplastie la plus répandue au monde est la prothèse totale de hanche (PTH) avec un couple de frottement métal-sur-polyéthylène (MPE). Cependant ce type d’intervention présente une longévité limitée à cause de l’usure de PE et ne convient pas aux patients actifs souffrant de coxarthrose sévère tôt dans leur vie. Afin de palier à ce problème, une nouvelle génération de surfaces de frottement métal-sur-métal (MM) est actuellement employée. Ces surfaces de frottement sont utilisées en PTH avec tête de 28 mm, en resurfaçage (RH) et avec la PTH à tête de grand diamètre. Alors qu’il y a beaucoup d’évidence à l’égard du bon fonctionnement des implants PTH 28 mm et du RH, les données quant aux performances in vivo des PTH MM à grand diamètre manquent. Malgré cela, ces implants sont utilisés à grande échelle. Dans un premier temps, l’objectif de ce travail de recherche était d’évaluer l’effet et de comparer les taux d’ions chrome (Cr) et cobalt (Co) chez des sujets porteurs de PTH MM à grand diamètre à ceux de 64 porteurs de RH, tous deux possédant des surfaces de frottement aux propriétés tribologiques identiques. Dans un deuxième temps, nous avons comparé les taux ioniques (Cr, Co et titane (Ti)) entre quatre PTH MM à grand diamètre provenant de fabricants différents (Zimmer, DePuy, Smith & Nephew et Biomet). Les mesures d’ions étaient effectuées dans le sang entier dans un laboratoire indépendant par la technique de spectrophotométrie de masse à haute résolution HR-ICP-MS, pour l’ensemble de ce travail de recherche. Les deux comparaisons ont démontré le rôle crucial joué par la modularité au niveau de la jonction tête-col des PTH MM à grand diamètre. En effet, des écarts considérables dans les concentrations ioniques de Co ont été retrouvés entre les RH et PTH Durom ayant un couple de frottement identique, ainsi qu’entre les 4 différents designs de PTH MM à grand diamètre comparés entre eux. La PTH MM à grand diamètre Durom était la moins favorable alors que celle de Biomet était la plus performante. Nos observations démontrent que des sources inattendues comme la jonction tête-col de certains implants PTH MM à grand diamètre peuvent contribuer au relargage ionique systémique. Une meilleure compréhension de ce phénomène est indispensable avant l’utilisation clinque de nouveaux implants de ce type.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introducción: En la actualidad se están implementando nuevas técnicas, para el tratamiento de líneas de expresión facial. El Plasma Rico en Plaquetas (PRP) utiliza factores de crecimiento humano autólogos con fines médicos estéticos. El objetivo de este trabajo fue evaluar el tratamiento con plasma rico en plaquetas en el manejo del rejuvenecimiento periocular. Materiales y métodos: Estudio descriptivo retrospectivo en una cohorte de 27 pacientes entre 30 a 70 años de ambos sexos,tratados con PRP sin tratamientos médicos estéticos previos . Se compararon fotografías del sistema VISIA®, previo y posterior el PRP, para determinar los cambios del área periocular. Con análisis comparativo de medias utilizando pruebas t de student. Resultados: De 27 historias clínicas revisadas 96,3% eran mujeres, la edad promedio fue de 52.67 años. Se observaron cambios clínicos satisfactorios en el manejo del foto envejecimiento periocular con mejoría estadísticamente significativa entre el promedio inicial y el post tratamiento en arrugas, textura y porfirinas (p: 0.000). No se observaron diferencias estadísticamente significativas entre los grupos de edad (p = 0,62). Los pacientes analizados posterior al tratamiento se encuentran en mejor estado que el 63,78% de la población de su mismo sexo, edad y fototipo de piel. Los eventos adversos fueron disminuyendo en su frecuencia en cada una de las sesiones siguientes. Discusión: El PRP proporciona una mejoría global en los parámetros de envejecimiento periocular lo cual se correlaciono con los estudios previos in vitro. Conclusiones: El PRP es seguro y eficaz en contorno de ojos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Primary stability of stems in cementless total hip replacements is recognized to play a critical role for long-term survival and thus for the success of the overall surgical procedure. In Literature, several studies addressed this important issue. Different approaches have been explored aiming to evaluate the extent of stability achieved during surgery. Some of these are in-vitro protocols while other tools are coinceived for the post-operative assessment of prosthesis migration relative to the host bone. In vitro protocols reported in the literature are not exportable to the operating room. Anyway most of them show a good overall accuracy. The RSA, EBRA and the radiographic analysis are currently used to check the healing process of the implanted femur at different follow-ups, evaluating implant migration, occurance of bone resorption or osteolysis at the interface. These methods are important for follow up and clinical study but do not assist the surgeon during implantation. At the time I started my Ph.D Study in Bioengineering, only one study had been undertaken to measure stability intra-operatively. No follow-up was presented to describe further results obtained with that device. In this scenario, it was believed that an instrument that could measure intra-operatively the stability achieved by an implanted stem would consistently improve the rate of success. This instrument should be accurate and should give to the surgeon during implantation a quick answer concerning the stability of the implanted stem. With this aim, an intra-operative device was designed, developed and validated. The device is meant to help the surgeon to decide how much to press-fit the implant. It is essentially made of a torsional load cell, able to measure the extent of torque applied by the surgeon to test primary stability, an angular sensor that measure the relative angular displacement between stem and femur, a rigid connector that enable connecting the device to the stem, and all the electronics for signals conditioning. The device was successfully validated in-vitro, showing a good overall accuracy in discriminating stable from unstable implants. Repeatability tests showed that the device was reliable. A calibration procedure was then performed in order to convert the angular readout into a linear displacement measurement, which is an information clinically relevant and simple to read in real-time by the surgeon. The second study reported in my thesis, concerns the evaluation of the possibility to have predictive information regarding the primary stability of a cementless stem, by measuring the micromotion of the last rasp used by the surgeon to prepare the femoral canal. This information would be really useful to the surgeon, who could check prior to the implantation process if the planned stem size can achieve a sufficient degree of primary stability, under optimal press fitting conditions. An intra-operative tool was developed to this aim. It was derived from a previously validated device, which was adapted for the specific purpose. The device is able to measure the relative micromotion between the femur and the rasp, when a torsional load is applied. An in-vitro protocol was developed and validated on both composite and cadaveric specimens. High correlation was observed between one of the parameters extracted form the acquisitions made on the rasp and the stability of the corresponding stem, when optimally press-fitted by the surgeon. After tuning in-vitro the protocol as in a closed loop, verification was made on two hip patients, confirming the results obtained in-vitro and highlighting the independence of the rasp indicator from the bone quality, anatomy and preserving conditions of the tested specimens, and from the sharpening of the rasp blades. The third study is related to an approach that have been recently explored in the orthopaedic community, but that was already in use in other scientific fields. It is based on the vibration analysis technique. This method has been successfully used to investigate the mechanical properties of the bone and its application to evaluate the extent of fixation of dental implants has been explored, even if its validity in this field is still under discussion. Several studies have been published recently on the stability assessment of hip implants by vibration analysis. The aim of the reported study was to develop and validate a prototype device based on the vibration analysis technique to measure intra-operatively the extent of implant stability. The expected advantages of a vibration-based device are easier clinical use, smaller dimensions and minor overall cost with respect to other devices based on direct micromotion measurement. The prototype developed consists of a piezoelectric exciter connected to the stem and an accelerometer attached to the femur. Preliminary tests were performed on four composite femurs implanted with a conventional stem. The results showed that the input signal was repeatable and the output could be recorded accurately. The fourth study concerns the application of the device based on the vibration analysis technique to several cases, considering both composite and cadaveric specimens. Different degrees of bone quality were tested, as well as different femur anatomies and several levels of press-fitting were considered. The aim of the study was to verify if it is possible to discriminate between stable and quasi-stable implants, because this is the most challenging detection for the surgeon in the operation room. Moreover, it was possible to validate the measurement protocol by comparing the results of the acquisitions made with the vibration-based tool to two reference measurements made by means of a validated technique, and a validated device. The results highlighted that the most sensitive parameter to stability is the shift in resonance frequency of the stem-bone system, showing high correlation with residual micromotion on all the tested specimens. Thus, it seems possible to discriminate between many levels of stability, from the grossly loosened implant, through the quasi-stable implants, to the definitely stable one. Finally, an additional study was performed on a different type of hip prosthesis, which has recently gained great interest thus becoming fairly popular in some countries in the last few years: the hip resurfacing prosthesis. The study was motivated by the following rationale: although bone-prosthesis micromotion is known to influence the stability of total hip replacement, its effect on the outcome of resurfacing implants has not been investigated in-vitro yet, but only clinically. Thus the work was aimed at verifying if it was possible to apply to the resurfacing prosthesis one of the intraoperative devices just validated for the measurement of the micromotion in the resurfacing implants. To do that, a preliminary study was performed in order to evaluate the extent of migration and the typical elastic movement for an epiphyseal prosthesis. An in-vitro procedure was developed to measure micromotions of resurfacing implants. This included a set of in-vitro loading scenarios that covers the range of directions covered by hip resultant forces in the most typical motor-tasks. The applicability of the protocol was assessed on two different commercial designs and on different head sizes. The repeatability and reproducibility were excellent (comparable to the best previously published protocols for standard cemented hip stems). Results showed that the procedure is accurate enough to detect micromotions of the order of few microns. The protocol proposed was thus completely validated. The results of the study demonstrated that the application of an intra-operative device to the resurfacing implants is not necessary, as the typical micromovement associated to this type of prosthesis could be considered negligible and thus not critical for the stabilization process. Concluding, four intra-operative tools have been developed and fully validated during these three years of research activity. The use in the clinical setting was tested for one of the devices, which could be used right now by the surgeon to evaluate the degree of stability achieved through the press-fitting procedure. The tool adapted to be used on the rasp was a good predictor of the stability of the stem. Thus it could be useful for the surgeon while checking if the pre-operative planning was correct. The device based on the vibration technique showed great accuracy, small dimensions, and thus has a great potential to become an instrument appreciated by the surgeon. It still need a clinical evaluation, and must be industrialized as well. The in-vitro tool worked very well, and can be applied for assessing resurfacing implants pre-clinically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lo scopo di questo studio è stato quello di determinare se a lungo termine le concentrazioni sieriche di ioni nei pazienti con protesi di rivestimento d’anca metallo-metallo (MOM-HR, metal-on-metal hip resurfacing) fossero differenti da quelle valutate nei pazienti con protesi totale d’anca metallo-metallo e testa del diametro di 28 mm (MOM-THA, metal-on-metal total hip arthroplasty); inoltre è stato valutato se le concentrazioni ioniche fossero al di sopra dei valori di riferimento e se fosse possibile stabilire l’esistenza di una relazione tra sesso e concentrazioni di ioni con riferimento al tipo di impianto. Il gruppo MOM-HR era costituito da 25 pazienti mentre il gruppo MOM-THA era di 16 pazienti. Per poter ricavare i valori di riferimento sono stati reclutati 48 donatori sani. La misurazione delle concentrazioni degli ioni cobalto (Co), cromo (Cr), nickel (Ni) e molibdeno (Mo) è stata effettuata utilizzando la spettrofotometria ad assorbimento atomico su fornace di grafite. A parte il Ni, le concentrazioni di ioni nei pazienti con MOM-HR erano più elevate rispetto ai controlli. Il rilascio di ioni Cr e Co nei pazienti con MOM-HR è risultato superiore rispetto ai soggetti con MOM-THA. Da un’analisi basata sul sesso, è emerso che nelle femmine con MOM-HR i livelli di ioni Cr e Co sono risultati significativamente aumentati rispetto alle femmine con MOM-THA. Indipendentemente dal tipo di impianto, gli accoppiamenti metallo-metallo (MOM) producono concentrazioni di ioni metallici significativamente più alte a follow-up a lungo termine rispetto a quelle osservate nei soggetti sani. Un fattore che deve essere attentamente considerato nella scelta dell’impianto, e in particolar modo nei soggetti giovani, è il cospicuo rilascio di ioni Cr e Co nella popolazione femminile con MOM-HR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A patient-specific surface model of the proximal femur plays an important role in planning and supporting various computer-assisted surgical procedures including total hip replacement, hip resurfacing, and osteotomy of the proximal femur. The common approach to derive 3D models of the proximal femur is to use imaging techniques such as computed tomography (CT) or magnetic resonance imaging (MRI). However, the high logistic effort, the extra radiation (CT-imaging), and the large quantity of data to be acquired and processed make them less functional. In this paper, we present an integrated approach using a multi-level point distribution model (ML-PDM) to reconstruct a patient-specific model of the proximal femur from intra-operatively available sparse data. Results of experiments performed on dry cadaveric bones using dozens of 3D points are presented, as well as experiments using a limited number of 2D X-ray images, which demonstrate promising accuracy of the present approach.