980 resultados para RADIOGRAPHY, DENTAL
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Pós-graduação em Biopatologia Bucal - ICT
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate the influence of digitization parameters on periapical radiographic image quality, with regard to anatomic landmarks. Digitized images (n = 160) were obtained using a flatbed scanner with resolutions of 300, 600 and 2400 dpi. The radiographs of 2400 dpi were decreased to 300 and 600 dpi before storage. Digitizations were performed with and without black masking using 8-bit and 16-bit grayscale and saved in TIFF format. Four anatomic landmarks were classified by two observers (very good, good, moderate, regular, poor), in two random sessions. Intraobserver and interobserver agreements were evaluated by Kappa statistics. Inter and intraobserver agreements ranged according to the anatomic landmarks and resolution used. The results obtained demonstrated that the cement enamel junction was the anatomic landmark that presented the poorest concordance. The use of black masking provided better results in the digitized image. The use of a mask to cover radiographs during digitization is necessary. Therefore, the concordance ranged from regular to moderate for the intraobserver evaluation and concordance ranged from regular to poor for interobserver evaluation.
Resumo:
The clinical records correspond to a set of documents where all information of the patient is stored. When properly confectioned and filed by the dentist, it may serve as a tool for success in dental expertise. The aim of this paper is to present the importance of proper confection of dental records in human identification by means the presentation of a case of identification, occurred in a São Paulo state city. The notes present in the dental records of the alleged victim were very poor, even with a contradiction. However, having endodontic treatment been performed, the comparative analysis between the radiographs of the skull of the victim (postmortem) and the endodontic treatment of tooth 22 (antemortem) permitted to observe total coincidence between the details of such treatment, and anatomical features present in other dental elements. These important parameters of comparison indicated that the body was of the suspect and, due to the number of coincidences, it could not belong to another individual. Nevertheless, the clinical documentation provided was deficient, and presented contradictory data. Because of its fundamental importance for human identification, it is essential that dental professionals take the necessary care to ensure its proper confection and custody, seeking to make the clinical records also an efficient instrument of consultation in identification cases.
Resumo:
The tooth eruption have been studied for many years about the knowledge of its variations. From these variations the difference between the eruption of the superior and inferior archs, and also the right and left sides have been poorly analysed. The author compared the alveolar eruption of the permanents canines, first and second premolars between the right and left sides of the superior and inferior archs, from 7 and 11 years of age, in males and females, by radiographic method. By the Discipline of Radiology of the Diagnosis and surgery Departament of the School of Dentistry of São José dos Campos - UNESP, observed that: there is early eruption in female; the alveolar eruption sequence in maxillar and mandibular was: first premolar, second premolar e canino. There wasn't statiscally significant difference of the alveolar eruption between the right and left sides of maxillar and mandibular archs
Resumo:
The author has verified the average depth of the mandibular fossa, in the X-ray image, using the oblique lateral transcranial technique from the right and left sides samples of each patient, which included a total of 176 patients, 87 male and 89 female. The patients were in following phases: deciduous dentítion (the patients had only deciduous teeth in the oral cavity or, if they had any permanent teeth, they could not be in occlusion), mixed dentition (the patients presented deciduous and permanent in the oral cavity) and permanent dentition (the patients had only permanent teeth in the oral cavity), until the eruption of the permanent third molars, in the region from São José dos Campos. São Paulo. Brazil. The patients were under treatment at the Dental School. UNESP (São Paulo State University). ln order to measure the depth of the mandibular fossa in millimeters an imaginary line was traced on the X-ray image, perpendicular to the other line that served as a reference, which was traced from the botton part of the articular eminence up to the tympanosquamous fissure. After the data were obtained and put in a data sheet, they underwent statistical analysis. The results showed that, in the average, the depth of the mandibular fossa in masculine sex is non-statistically signíficant larger than what was observed in feminíne sex, and the right side is larger than the left side, with significant statistical differences. However, only in permanent dentition, in masculine sex, the depth of the mandibular fossa on the right side is larger than on the left side with significant statistical differences
Resumo:
The aim of this study was to evaluate whether digitized images obtained from periapical radiographs taken with low dose of radiation could be improved with the aid of a computer software (PhotoStyler) for digital treatrnent. Serial and standardized radiographs of molar and premolar areas were studied. A total of 57 images equivalent to the radiographs taken with reduced exposure time ( 60 and 80% of the time considered normal), digitized and treated, were submitted to the evaluation of seven exanúners which compared them with those images without treatment. lt was verified that about 80% of the images equivalem to lhe radiographs taken with 60% reduction of ordinary exposure time were considered to having quality for supporting diagnosis. As for the images taken with 80% reduction of ordinary exposure time, about 50% of them were considered suitable for the sarne purpose
Resumo:
Objective: The purpose of this study was to analyse the use of digital tools for image enhancement of mandibular radiolucent lesions and the effects of this manipulation on the percentage of correct radiographic diagnoses. Methods: 24 panoramic radiographs exhibiting radiolucent lesions were selected, digitized and evaluated by non-experts (undergraduate and newly graduated practitioners) and by professional experts in oral diagnosis. The percentages of correct and incorrect diagnoses, according to the use of brightness/contrast, sharpness, inversion, highlight and zoom tools, were compared. All dental professionals made their evaluations without (T-1) and with (T-2) a list of radiographic diagnostic parameters. Results: Digital tools were used with low frequency mainly in T-2. The most preferred tool was sharpness (45.2%). In the expert group, the percentage of correct diagnoses did not change when any of the digital tools were used. For the non-expert group, there was an increase in the frequency of correct diagnoses when brightness/contrast was used in T-2 (p = 0.008) and when brightness/contrast and sharpness were not used in T-1 (p = 0.027). The use or non-use of brightness/contrast, zoom and sharpness showed moderate agreement in the group of experts [kappa agreement coefficient (kappa) = 0.514, 0.425 and 0.335, respectively]. For the non-expert group there was slight agreement for all the tools used (kappa <= 0.237). Conclusions: Consulting the list of radiographic parameters before image manipulation reduced the frequency of tool use in both groups of examiners. Consulting the radiographic parameters with the use of some digital tools was important for improving correct diagnosis only in the group of non-expert examiners. Dentomaxillofacial Radiology (2012) 41, 203-210. doi: 10.1259/dmfr/78567773
Resumo:
Diagnostic radiology represents the largest man-made contribution to population radiation doses in Europe. To be able to keep the diagnostic benefit versus radiation risk ratio as high as possible, it is important to understand the quantitative relationship between the patient radiation dose and the various factors which affect the dose, such as the scan parameters, scan mode, and patient size. Paediatric patients have a higher probability for late radiation effects, since longer life expectancy is combined with the higher radiation sensitivity of the developing organs. The experience with particular paediatric examinations may be very limited and paediatric acquisition protocols may not be optimised. The purpose of this thesis was to enhance and compare different dosimetric protocols, to promote the establishment of the paediatric diagnostic reference levels (DRLs), and to provide new data on patient doses for optimisation purposes in computed tomography (with new applications for dental imaging) and in paediatric radiography. Large variations in radiation exposure in paediatric skull, sinus, chest, pelvic and abdominal radiography examinations were discovered in patient dose surveys. There were variations between different hospitals and examination rooms, between different sized patients, and between imaging techniques; emphasising the need for harmonisation of the examination protocols. For computed tomography, a correction coefficient, which takes individual patient size into account in patient dosimetry, was created. The presented patient size correction method can be used for both adult and paediatric purposes. Dental cone beam CT scanners provided adequate image quality for dentomaxillofacial examinations while delivering considerably smaller effective doses to patient compared to the multi slice CT. However, large dose differences between cone beam CT scanners were not explained by differences in image quality, which indicated the lack of optimisation. For paediatric radiography, a graphical method was created for setting the diagnostic reference levels in chest examinations, and the DRLs were given as a function of patient projection thickness. Paediatric DRLs were also given for sinus radiography. The detailed information about the patient data, exposure parameters and procedures provided tools for reducing the patient doses in paediatric radiography. The mean tissue doses presented for paediatric radiography enabled future risk assessments to be done. The calculated effective doses can be used for comparing different diagnostic procedures, as well as for comparing the use of similar technologies and procedures in different hospitals and countries.
Resumo:
Objectives: The aim of this study was to evaluate the genotoxic effects of X-rays on epithelial gingival cells during panoramic dental radiography using a differentiated protocol for the micronucleus test. Methods: 40 healthy individuals who underwent this procedure for diagnostic purposes on request from their dentists agreed to participate in this study. All of them answered a questionnaire before the examination. Epithelial gingival cells were obtained from the keratinized mucosa of the upper dental arcade by gentle scraping with a cervical brush immediately before exposure and 10 days later. Cytological preparations were stained according to the Feulgen-Rossenbeck reaction, counterstained with fast green 1% for 1 min and analysed under a light microscope. Micronuclei, nuclear projections (broken eggs) and degenerative nuclear alterations (pyknosis, karyolysis, karyorrhexis and condensed chromatin) were scored. Results: The frequency of micronuclei was significantly higher after exposure (P < 0.05), as were frequencies of nuclear alterations indicate of apoptosis (P < 0.001). Conclusions: These results indicate that X-ray radiation emitted during panoramic dental radiography induces a genotoxic effect on epithelial gingival cells that increases the frequency of chromosomal damage and nuclear alterations indicative of apoptosis.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Dental Panoramic Tomography (DPT) is a widely used and valuable examination in dentistry. One area prone to artefacts and therefore misinterpretation is the anterior region of the mandible. This case study discusses a periapical radiolucency related to lower anterior teeth that is discovered to be a radiographic artefact. Possible causes of the artefact include a pronounced depression in the mental region of the mandible or superimposition of intervertebral spaces. Additional limitations of the DPT image include superimposition of radio-opaque structures, reduced image detail compared to intra-oral views and uneven magnification. These problems often make the DPT inappropriate for imaging the anterior mandible.
CLINICAL RELEVANCE: Panoramic radiography is often unsuitable for radiographic examination of the anterior mandible.