991 resultados para Probeneintrag, Massenspektrometrie, ICP-MS, Atmosphärendruck-Ionisation
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia e Gestão Industrial
Resumo:
Recrystallization rims are a common feature of zircon crystals that underwent metamorphism. We present a microstructural and microchemical study of partially recrystallized zircon grains collected in polymetamorphic migmatites (Valle d'Arbedo, Ticino, Switzerland). The rims are bright in cathodo-luminescence (CL), with sharp and convex contacts characterized by inward-penetrating embayments transgressing igneous zircon cores. Laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS) data and transmission electron microscopy (TEM) imaging indicate that the rims are chemically and microstructurally different from the cores. The rims are strongly depleted in REE, with concentrations up to two orders of magnitude lower than in the cores, indicating a significant loss of REE during zircon recrystallization. Enrichment in non-formula elements, such as Ca, has not been observed in the rims. The microstructure of zircon cores shows a dappled intensity at and below the 100 nm scale, possibly due to radiation damage. Other defects such as pores and dislocations are absent in the core except at healed cracks. Zircon rims are mostly dapple-free, but contain nanoscale pores and strain centers, interpreted as fluid inclusions and chemical residues, respectively. Sensitive high-resolution ion microprobe (SHRIMP) U-Pb ages show that the recrystallization of the rims took place >200 Ma ago when the parent igneous zircon was not metamict. The chemical composition and the low-Ti content of the rims indicate that they form at sub-solidus temperatures (550-650 degrees C). Recrystallization rims in Valle d'Arbedo zircon are interpreted as the result of the migration of chemical reaction fronts in which fluid triggered in situ and contemporaneous interface-coupled dissolution-reprecipitation mechanisms. This study indicates that strong lattice strain resulting from the incorporation of a large amount of impurities and structural defects is not a necessary condition for zircon to recrystallize. Our observations suggest that the early formation of recrystallization rims played a major role in preserving zircon from the more recent Alpine metamorphic overprint.
Resumo:
For the first time, an albite orthogneiss has been recognised and dated within the HP-LT blueschist facies metabasites and metapelites of the Ile de Groix. It is characterised by a peraluminous composition, high LILE, Th and U contents, MORB-like HREE abundances and moderate Nb and Y values. A U-Pb age of 480.8 +/- A 4.8 Ma was obtained by LA-ICP-MS dating of zircon and titanite. It is interpreted as the age of the magmatic emplacement during the Early Ordovician. Morphologically different zircon grains yield late Neoproterozoic ages of 546.6-647.4 Ma. Zircon and titanite U-Pb ages indicate that the felsic magmatism from the Ile de Groix is contemporaneous with the acid, pre-orogenic magmatism widely recognised in the internal zones of the Variscan belt, related to the Cambro-Ordovician continental rifting. The magmatic protolith probably inherited a specific chemical composition from a combination of orogenic, back-arc and anorogenic signatures because of partial melting of the Cadomian basement during magma emplacement. Besides, the late Devonian U-Pb age of 366 +/- A 33 Ma obtained for titanite from a blueschist facies metapelite corresponds to the age of the HP-LT peak metamorphism.
Resumo:
U-Pb dating of zircons by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is a widely used analytical technique in Earth Sciences. For U-Pb ages below 1 billion years (1 Ga), Pb-206/U-238 dates are usually used, showing the least bias by external parameters such as the presence of initial lead and its isotopic composition in the analysed mineral. Precision and accuracy of the Pb/U ratio are thus of highest importance in LA-ICPMS geochronology. We consider the evaluation of the statistical distribution of the sweep intensities based on goodness-of-fit tests in order to find a model probability distribution fitting the data to apply an appropriate formulation for the standard deviation. We then discuss three main methods to calculate the Pb/U intensity ratio and its uncertainty in the LA-ICPMS: (1) ratio-of-the-mean intensities method, (2) mean-of-the-intensity-ratios method and (3) intercept method. These methods apply different functions to the same raw intensity vs. time data to calculate the mean Pb/U intensity ratio. Thus, the calculated intensity ratio and its uncertainty depend on the method applied. We demonstrate that the accuracy and, conditionally, the precision of the ratio-of-the-mean intensities method are invariant to the intensity fluctuations and averaging related to the dwell time selection and off-line data transformation (averaging of several sweeps); we present a statistical approach how to calculate the uncertainty of this method for transient signals. We also show that the accuracy of methods (2) and (3) is influenced by the intensity fluctuations and averaging, and the extent of this influence can amount to tens of percentage points; we show that the uncertainty of these methods also depends on how the signal is averaged. Each of the above methods imposes requirements to the instrumentation. The ratio-of-the-mean intensities method is sufficiently accurate provided the laser induced fractionation between the beginning and the end of the signal is kept low and linear. We show, based on a comprehensive series of analyses with different ablation pit sizes, energy densities and repetition rates for a 193 nm ns-ablation system that such a fractionation behaviour requires using a low ablation speed (low energy density and low repetition rate). Overall, we conclude that the ratio-of-the-mean intensities method combined with low sampling rates is the most mathematically accurate among the existing data treatment methods for U-Pb zircon dating by sensitive sector field ICPMS.
Resumo:
(241)Pu was determined in slurry samples from a nuclear reactor decommissioning project at the Paul Scherrer Institute (Switzerland). To validate the results, the (241)Pu activities of five samples were determined by LSC (TriCarb and Quantulus) and ICP-MS, with each instrument at a different laboratory. In lack of certified reference materials for (241)Pu, the methods were further validated using the (241)Pu information values of two reference sediments (IAEA-300 and IAEA-384). Excellent agreement with the results was found between LSC and ICP-MS in the nuclear waste slurries and the reference sediments.
Resumo:
An automatic dispenser based on a flow-injection system used to introduce sample and analytical solution into an inductively coupled plasma mass spectrometer through a spray chamber is proposed. Analytical curves were constructed after the injection of 20 to 750 µL aliquots of a multielement standard solution (20.0 µg L-1 in Li, Be, Al, V, Cr, Mn, Ni, Co, Cu, Zn, As, Se, Sr, Ag, Cd, Ba, Tl, Pb) and the acquisition of the integrated transient signals. The linear concentration range could be extended to ca. five decades. The performance of the system was checked by analyzing a NIST 1643d reference material. Accuracy could be improved by the proper selection of the injected volume. Besides good precision (r.s.d. < 2%), the results obtained with the proposed procedure were closer to the certified values of the reference material than those obtained by direct aspiration or by injecting 125 µL of several analytical solutions and samples.
Resumo:
The multi-element determination of Al, Cr, Mn, Ni, Cu, Zn, Cd, Ba, Pb, SO4= and Cl- in riverine water samples was accomplished by inductively coupled plasma mass spectrometry (ICP-MS). The sample passed through a column containing the anionic resin AG1-X8 and the metals were determined directly. The retained anionic species were eluted and SO4= and Cl- were determined at m/z 48 and 35 correspondent to the ions SO+ and Cl+ formed at the plasma. Accuracy for metals was assessed by analysing the certified reference TM-26 (National Water Research Institute of Canada). Results for SO4= and Cl- were in agreement with those obtained by turbidimetry and spectrophotometry. LOD's of 0.1 µg l-1 for Cd, Ba and Pb; 0.2 µg l-1 for Al, Mn and Cu; 0.5 µg l-1 for Cr; 0.9 for Zn; 2.0 µg l-1for Ni , 60 µg l-1 for S and 200 µg l-1 Cl were attained.
Resumo:
Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1) prewashing of the column with methanol (80% v/v); (2) use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9) with a flow rate of 1 mL/min. Sample detection limits (3s) for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L) and Ultrasonic (18 mug/L); ICP-MS -Cross flow (1.2 mug/L), Cyclonic (0.7 mug/L) and Ultrasonic (0.5 mug/L). Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts.
Resumo:
A method based on microwave-induced combustion (MIC) was applied for the decomposition of different types of edible seaweed (Nori, Hijiki and Wakame) for subsequent determination of bromine and iodine by inductively coupled plasma mass spectrometry (ICP-MS). Decomposition of 500 mg of each sample was achieved in less than 30 min. A single and diluted solution (150 mmol L-1 (NH4)2CO3) was used for the absorption of both analytes and a reflux step of 5 min was applied to improve analyte recoveries. Accuracy was evaluated using certified reference materials and agreement was between 103 and 108% for both elements.
Resumo:
Coral growth rate can be affected by environmental parameters such as seawater temperature, depth, and light intensity. The natural reef environment is also disturbed by human influences such as anthropogenic pollutants, which in Barbados are released close to the reefs. Here we describe a relatively new method of assessing the history of pollution and explain how these effects have influenced the coral communities off the west coast of Barbados. We evaluate the relative impact of both anthropogenic pollutants and natural stresses. Sclerochronology documents framework and skeletal growth rate and records pollution history (recorded as reduced growth) for a suite of sampled Montastraea annularis coral cores. X-radiography shows annual growth band patterns of the corals extending back over several decades and indicates significantly lower growth rate in polluted sites. Results using laser-ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) on the whole sample (aragonite, organic matter, trapped particulate matter, etc.), have shown contrasting concentrations of the trace elements (Cu, Sn, Zn, and Pb) between corals at different locations and within a single coral. Deepwater corals 7 km apart, record different levels of Pb and Sn, suggesting that a current transported the metal pollution in the water. In addition, the 1995 hurricanes are associated with anomalous values for Sn and Cu from most sites. These are believed to result from dispersion of nearshore polluted water. We compared the concentrations of trace elements in the coral growth of particular years to those in the relevant contemporaneous seawater. Mean values for the concentration factor in the coral, relative to the water, ranged from 10 for Cu and Ni to 2.4 and 0.7 for Cd and Zn, respectively. Although the uncertainties are large (60-80%), the coral record enabled us to demonstrate the possibility of calculating a history of seawater pollution for these elements from the 1940s to 1997. Our values were much higher than those obtained from analysis of carefully cleaned coral aragonite; they demonstrate the incorporation of more contamination including that from particulate material as well as dissolved metals.
Resumo:
Tests are described showing the results obtained for the determination of REE and the trace elements Rb, Y, Zr, Nb, Cs, Ba, Hf, Ta, Pb, Th and U with ICP-MS methodology for nine basaltic reference materials, and thirteen basalts and amphibolites from the mafic-ultramafic Niquelandia Complex, central Brazil. Sample decomposition for the reference materials was performed by microwave oven digestion (HF and HNO(3), 100 mg of sample), and that for the Niquelandia samples also by Parr bomb treatment (5 days at 200 degrees C, 40 mg of sample). Results for the reference materials were similar to published values, thus showing that the microwave technique can be used with confidence for basaltic rocks. No fluoride precipitates were observed in the microwave-digested solutions. Total recovery of elements, including Zr and Hf, was obtained for the Niquelandia samples, with the exception of an amphibolite. For this latter sample, the Parr method achieved a total digestion, but not so the microwave decomposition; losses, however, were observed only for Zr and Hf, indicating difficulty in dissolving Zr-bearing minerals by microwave acid attack.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A flow-injection (FI) system to match concentrations was used as an auto-diluter in multielement determination by inductively coupled plasma-mass spectrometry (ICP-MS). The flow system comprised loop-based injection or a timed valve that introduced a variable sample volume info a spray chamber through a standard Meinhard nebulizer of an ICP-MS. Routinely analyzed samples such as water, plant, and steel were selected. The accuracy of multielement determination was checked against water standard reference material from the National Institute of Standards and Technology (1643d), plant standard reference material from the National Bureau of Standards (1572 citrus leaves), and steel standard reference material from the National Bureau of Standards (AISI 4340). The measuring system was calibrated with a multielement solution, yielding a linear plot with good precision [relative standard deviation (RSD) < 3%, n = 12]. The results were in agreement at a 95% confidence level with the certified values for the reference materials and also with those obtained by continuous aspiration and by (FI) with a discrete volume. (C) 1999 John Wiley & Sons, Inc.