402 resultados para Policlorobifenili (PCB)
Resumo:
We hypothesize that the impact of PCB desorption from resuspended sediments depends upon the intensity of the resuspension (which scales to bottom stress in the absence of organisms), the rate at which each congener desorbs (which depends on the size and hydrophobicity of the chemical, the relative amount of 'labile' and 'resistant' forms, and the size distribution of the suspended particles), and the residence time of the particles in the water column (which depends on the time-variable water column turbulence regime and the particle settling velocities). In order to accurately quantify the impact of PCB desorption from Hudson River sediments, we are conducting experiments that realistically mimic bottom shear stress and water column turbulence and rapidly measure PCB congener release. The objectives of this study are to measure the kinetics of PCB congener desorption from Hudson River sediments under realistic bottom shear and water column turbulence conditions and to quantify the impact of shear stress and contaminant aging on PCB desorption kinetics.
Resumo:
A novel technological platform for multiple gas detection based on the use of PCB-integrated polymer waveguides is presented. A proof-of-principle ammonia sensor is reported integrating onto low-cost FR4 substrates all essential photonic, electronic and chemical components. The device's potential to detect multiple gases is demonstrated. © 2011 IEEE.
Resumo:
A novel integration method for the production of cost-effective optoelectronic printed circuit boards (OE PCBs) is presented. The proposed integration method allows fabrication of OE PCBs with manufacturing processes common to the electronics industry while enabling direct attachment of electronic components onto the board with solder reflow processes as well as board assembly with automated pick-and-place tools. The OE PCB design is based on the use of polymer multimode waveguides, end-fired optical coupling schemes, and simple electro-optic connectors, eliminating the need for additional optical components in the optical layer, such as micro-mirrors and micro-lenses. A proof-of-concept low-cost optical transceiver produced with the proposed integration method is presented. This transceiver is fabricated on a low-cost FR4 substrate, comprises a polymer Y-splitter together with the electronic circuitry of the transmitter and receiver modules and achieves error-free 10-Gb/s bidirectional data transmission. Theoretical studies on the optical coupling efficiencies and alignment tolerances achieved with the employed end-fired coupling schemes are presented while experimental results on the optical transmission characteristics, frequency response, and data transmission performance of the integrated optical links are reported. The demonstrated optoelectronic unit can be used as a front-end optical network unit in short-reach datacommunication links. © 2011-2012 IEEE.
Resumo:
This paper presents a novel platform for the formation of cost-effective PCB-integrated optical waveguide sensors. The sensor design relies on the use of multimode polymer waveguides that can be formed directly on standard PCBs and commercially-available chemical dyes, enabling the integration of all essential sensor components (electronic, photonic, chemical) on low-cost substrates. Moreover, it enables the detection of multiple analytes from a single device by employing waveguide arrays functionalised with different chemical dyes. The devices can be manufactured with conventional methods of the PCB industry, such as solder-reflow processes and pick-and-place assembly techniques. As a proof of principle, a PCB-integrated ammonia gas sensor is fabricated on a FR4 substrate. The sensor operation relies on the change of the optical transmission characteristics of chemically functionalised optical waveguides in the presence of ammonia molecules. The fabrication and assembly of the sensor unit, as well as fundamental simulation and characterisation studies, are presented. The device achieves a sensitivity of approximately 30 ppm and a linear response up to 600 ppm at room temperature. Finally, the potential to detect multiple analytes from a single device is demonstrated using principal-component analysis. © 1983-2012 IEEE.
Resumo:
Bioavailable water concentrations of polycyclic aromatic hydrocarbons (PAH), polychlorinated biphenyls (PCB) and organochlorine pesticides (OCP) were measured in the water column from Three Gorges Reservoir (TGR) collected in May 2008 using semipermeable membrane devices (SPMDs). The sampling sites spanned the whole reservoir from the upstream Chongqing to the great dam covering more than 600 km long distance with water flow velocities ranging from <0.05 to 1.5 m s(-1). This is the first experience of SPMD application in the biggest reservoir in the world. The results of water sampling rates based on performance reference compounds (PRC) were tested to be significantly correlated with water flow velocities in the big river. Results of back-calculated aqueous concentrations based on PRC showed obvious regional variations of PAH, PCB and OCP levels in the reservoir. Total PAH ranged from 13.8 to 97.2 ng L-1, with the higher concentrations occurring in the region of upstream and near the dam. Phenanthrene, fluoranthene, pyrene and chrysene were the predominant PAH compounds in TGR water. Total PCB ranged from 0.08 to 0.51 ng L-1, with the highest one occurring in the region near the dam. PCB 28, 52, 101, 138, 153, 180, 118 were the most abundant PCB congeners in the water. The total OCP ranged from 2.33 to 3.60 ng L-1 and the levels showed homogenous distribution in the whole reservoir. HCH, DDT and HCB, PeCB were the major compounds of OCP fingerprints. Based on water quality criteria, the TGR water could be designated as being polluted by HCB and PAH. Data on PAH, PCB and OCP concentrations found in this survey can be used as reference levels for future POP monitoring programmes in TGR. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
An optical waveguide sensor formed directly on low-cost PCB substrates is presented for the first time. The device integrates polymer waveguides functionalized with chemical dyes, photonic and electronic components and allows multiple-gas detection. © OSA/CLEO 2011.
Resumo:
Optical switching functionality is demonstrated in PCB integrated multimode passive polymer waveguides using a localised liquid-crystal cladding structure. Waveguide switching contrast of 15 dB is achieved with only 0.5 dB of on-state excess loss. © 2009 OSA.
Resumo:
本发明公开了一种实现微电极阵列与PCB电路柔性连接的方法,该方法包括:制作PCB接口板;将弹簧针插座焊接在该PCB接口板上,并将弹簧针针体插在插座上构成弹性针床;将弹簧针针体的头部对准微电极阵列接口电极,通过紧固螺丝压缩弹簧针,将弹簧针针体的头部与电极形成接触连接;将弹簧针插座端的引线与电生理信号放大器和刺激器进行连接,引线端与中心部分微电极一一对应,实现微电极阵列和外围电路的电气连接。本发明缩短了微电极阵列接口板的制作周期,节约了制作成本,针床与电极接触良好而不磨损电极表面金属层,电极的导电性能不受影响,延长了微电极阵列寿命。
Resumo:
Un robot autobalanceado es un dispositivo que, aun teniendo su centro de masas por encima del eje de giro, consigue mantener el equilibrio. Se basa o aproxima al problema del péndulo invertido. Este proyecto comprende el desarrollo e implementación de un robot autobalanceado basado en la plataforma Arduino. Se utilizará una placa Arduino y se diseñará y fabricará con un shield o tarjeta (PCB), donde se incluirán los elementos hardware que se consideren necesarios. Abarca el estudio y montaje del chasis y los sistemas de sensado, control digital, alimentación y motores
Resumo:
An investigation of 24 buildings in the Greater Boston Area revealed that one-third (8 of 24) contained caulking materials with polychlorinated biphenyl (PCB) content exceeding 50 ppm by weight, which is the U.S. Environmental Protection Agency (U.S. EPA) specified limit above which this material is considered to be PCB bulk product waste. These buildings included schools and other public buildings. In a university building where similar levels of PCB were found in caulking material, PCB levels in indoor air ranged from 111 to 393 ng/m3; and in dust taken from the building ventilation system, < 1 ppm to 81 ppm. In this building, the U.S. EPA mandated requirements for the removal and disposal of the PCB bulk product waste as well as for confirmatory sampling to ensure that the interior and exterior of the building were decontaminated. Although U.S. EPA regulations under the Toxic Substances Control Act stipulate procedures by which PCB-contaminated materials must be handled and disposed, the regulations apparently do not require that materials such as caulking be tested to determine its PCB content. This limited investigation strongly suggests that were this testing done, many buildings would be found to contain high levels of PCBs in the building materials and potentially in the building environment. The presence of PCBs in schools is of particular concern given evidence suggesting that PCBs are developmental toxins.
Resumo:
A simple design for a low-profile high-gain planar antenna has been presented in the letter. The antenna has the realized gain between 9 and 11 dBi and the return loss better than 10 dB over the 5.6-6.3-GHz frequency band, i.e. 11% bandwidth. A numerical study highlighting effects of key geometrical parameters on the gain and return loss of the antenna has been performed. It has been shown as well that the presented antenna occupies area 20% smaller than a conventional microstrip patch antenna array with a similar gain.