981 resultados para Poiseulli, endotracheal tubes, cuff, pediatric, airway


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The choice of model used to study human respiratory syncytial virus (RSV) infection is extremely important. RSV is a human pathogen that is exquisitely adapted to infection of human hosts. Rodent models, such as mice and cotton rats, are semi-permissive to RSV infection and do not faithfully reproduce hallmarks of RSV disease in humans. Furthermore, immortalized airway-derived cell lines, such as HEp-2, BEAS-2B, and A549 cells, are poorly representative of the complexity of the respiratory epithelium. The development of a well-differentiated primary pediatric airway epithelial cell models (WD-PAECs) allows us to simulate several hallmarks of RSV infection of infant airways. They therefore represent important additions to RSV pathogenesis modeling in human-relevant tissues. The following protocols describe how to culture and differentiate both bronchial and nasal primary pediatric airway epithelial cells and how to use these cultures to study RSV cytopathogenesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción La ventilación mecánica es fundamental en el manejo de la falla respiratoria aguda, actualmente no existe consenso sobre el momento exacto de extubación. Este estudio describe el comportamiento de la escala OMAHA+ en nuestra institución. Objetivo Principal Describir los desenlaces clínicos relacionados con la escala OMAHA+ durante la extubación de los pacientes de las unidades de cuidado intensivo del hospital universitario. Métodos Estudio descriptivo, retrospectivo, basado en el registro de la escala OMAHA+ de 68 pacientes durante el proceso de extubación en las Unidades de cuidado intensivo adulto de la Fundación Santa Fe de Bogotá durante Agosto de 2014 a Mayo de 2015. Resultados Se encontraron valores gasométricos cercanos a la normalidad, con una PaO2/FiO2 media de 261 (DS 60,6), SaO2 media de 96% (DS 2%), media de lactato sérico de 1.5 mmol/L (DS 1,2 mmol/L), con signos vitales normales. La causa más común de ingreso a UCI fue Neumonía, seguida por cirugía cardiaca y abdominal. Las medias de parámetros ventilatorios al momento de extubación fueron; PEEP de 6 (DS 0,8), volumen corriente de 8ml/Kg (DS 1,4 ml/Kg), índice de Tobín de 34 (DS 11,9), test de fuga positivo 94%, y sólo una extubación fallida. Conclusiones La escala OMAHA+ puede ser una herramienta útil, aplicable y fácilmente reproducible en los pacientes con soporte ventilatorio mecánico invasivo previo al proceso de extubación, con baja proporción de fallo. Estos resultados deben ser evaluados en estudios prospectivos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The case of Re Baby D (No. 2) has been described as a “landmark decision” as to whether parents themselves can authorise medical staff to withdraw life-sustaining treatment from their child or are required to seek the permission of a court or tribunal. The reasons for the decision that the removal of an endotracheal tube from the airway of Baby D was to treat “a bodily malfunction or disease” and therefore could be authorised by the parents will be explored.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine the prevalence, severity, location, etiology, treatment, and healing of medical device-related pressure ulcers in intensive care patients for up to 7 days. Design: Prospective repeated measures study. Setting and participants: Patients in 6 intensive care units of 2 major medical centers, one each in Australia and the United States, were screened 1 day per month for 6 months. Those with device-related ulcers were followed daily up to 7 days. Outcome measures: Device-related ulcer prevalence, pain, infection, treatment, healing. Results: 15/483 patients had device-related ulcers and 9/15 with 11 ulcers were followed beyond screening. Their mean age was 60.5 years, most were men, over-weight, and at increased pressure ulcer risk. Endotracheal and nasogastric tubes were the cause of most device-related ulcers. Repositioning was the most frequent treatment. 4/11 ulcers healed within the 7 day observation period. Conclusion: Device-related ulcer prevalence was 3.1%, similar to that reported in the limited literature available, indicating an ongoing problem. Systematic assessment and repositioning of devices are the mainstays of care. We recommend continued prevalence determination and that nurses remain vigilant to prevent device-related ulcers, especially in patients with nasogastric and endotracheal tubes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In all but the most sterile environments bacteria will reside in fluid being transported through conduits and some of these will attach and grow as biofilms on the conduit walls. The concentration and diversity of bacteria in the fluid at the point of delivery will be a mix of those when it entered the conduit and those that have become entrained into the flow due to seeding from biofilms. Examples include fluids through conduits such as drinking water pipe networks, endotracheal tubes, catheters and ventilation systems. Here we present two probabilistic models to describe changes in the composition of bulk fluid microbial communities as they are transported through a conduit whilst exposed to biofilm communities. The first (discrete) model simulates absolute numbers of individual cells, whereas the other (continuous) model simulates the relative abundance of taxa in the bulk fluid. The discrete model is founded on a birth-death process whereby the community changes one individual at a time and the numbers of cells in the system can vary. The continuous model is a stochastic differential equation derived from the discrete model and can also accommodate changes in the carrying capacity of the bulk fluid. These models provide a novel Lagrangian framework to investigate and predict the dynamics of migrating microbial communities. In this paper we compare the two models, discuss their merits, possible applications and present simulation results in the context of drinking water distribution systems. Our results provide novel insight into the effects of stochastic dynamics on the composition of non-stationary microbial communities that are exposed to biofilms and provides a new avenue for modelling microbial dynamics in systems where fluids are being transported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In practice, polyvinyl chloride endotracheal tubes and polyurethane urinary catheters are located in areas where they are exposed to the conditioning fluids saliva and urine, respectively. Samples of both biomaterials were incubated in these conditioning fluids and, following treatment, dynamic contact angle measurement and surface roughness assessment by atomic force microscopy were used to analyse surface characteristics. Over a 24 h period of contact with the conditioning fluids, the surface of both materials became significantly more hydrophilic (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background
Mechanical ventilation is a life-saving intervention for critically ill newborn infants with respiratory failure admitted to a neonatal intensive care unit (NICU). Ventilating newborn infants can be challenging due to small tidal volumes, high breathing frequencies, and the use of uncuffed endotracheal tubes. Mechanical ventilation has several short-term, as well as long-term complications. To prevent complications, weaning from the ventilator is started as soon as possible. Weaning aims to support the transfer from full mechanical ventilation support to spontaneous breathing activity.

Objectives
To assess the efficacy of protocolized versus non-protocolized ventilator weaning for newborn infants in reducing the duration of invasive mechanical ventilation, the duration of weaning, and shortening the NICU and hospital length of stay. To determine efficacy in predefined subgroups including: gestational age and birth weight; type of protocol; and type of protocol delivery. To establish whether protocolized weaning is safe and clinically effective in reducing the duration of mechanical ventilation without increasing the risk of adverse events.

Search methods
We searched the Cochrane Central Register of Controlled trials (CENTRAL; the Cochrane Library; 2015, Issue 7); MEDLINE In-Process and other Non-Indexed Citations and OVID MEDLINE (1950 to 31 July 2015); CINAHL (1982 to 31 July 2015); EMBASE (1988 to 31 July 2015); and Web of Science (1990 to 15 July 2015). We did not restrict language of publication. We contacted authors of studies with a subgroup of newborn infants in their study, and experts in the field regarding this subject. In addition, we searched abstracts from conference proceedings, theses, dissertations, and reference lists of all identified studies for further relevant studies.

Selection criteria
Randomized, quasi-randomized or cluster-randomized controlled trials that compared protocolized with non-protocolized ventilator weaning practices in newborn infants with a gestational age of 24 weeks or more, who were enrolled in the study before the postnatal age of 28 completed days after the expected date of birth.

Data collection and analysis
Four authors, in pairs, independently reviewed titles and abstracts identified by electronic searches. We retrieved full-text versions of potentially relevant studies.

Main results
Our search yielded 1752 records. We removed duplicates (1062) and irrelevant studies (843). We did not find any randomized, quasi-randomized or cluster-randomized controlled trials conducted on weaning from mechanical ventilation in newborn infants. Two randomized controlled trials met the inclusion criteria on type of study and type of intervention, but only included a proportion of newborns. The study authors could not provide data needed for subgroup analysis; we excluded both studies.

Authors' conclusions
Based on the results of this review, there is no evidence to support or refute the superiority or inferiority of weaning by protocol over non-protocol weaning on duration of invasive mechanical ventilation in newborn infants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Anestesiologia - FMB

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Sedation is crucial for the recovery of patients in intensive care units (ICUs). Maintaining comfort and safety promotes optimal care for critically ill patients. Purpose: To examine sedation assessment and management undertaken by health professionals for mechanically ventilated patients in one Australian ICU. Methods: A retrospective clinical audit was undertaken of medical records of all eligible, mechanically ventilated patients admitted to an ICU of an Australian metropolitan, teaching hospital over a 12-month period. A Sedation Audit Tool was used to collect data from the day of intubation to 5 days after intubation. Findings: Data were extracted from medical records of 150 patients. The Riker Sedation-Agitation Scale (SAS) was the scoring system used. Patients were unarousable or very sedated between 57% and 81% at some point during the study period, while between 5% and 11% were agitated, very agitated or extremely agitated across this time. Patients' sedation scores were not documented in between 3.3% and 23.3% of patients. Medications commonly used were propofol, midazolam, morphine, and fentanyl. There were 135 situations of adverse events, which related to patients pulling endotracheal tubes leading to malpositioning, patients biting endotracheal tubes causing desaturation, patient experiencing excessive agitation requiring restraint use, patients experiencing increased intracranial pressure above desired limits, patients self-extubating, and patients experiencing over-drowsiness leading to delays in extubation. Conclusions: Many patients were either very sedated or agitated at some point during the study period, and some patients experienced adverse outcomes associated with sedation practices. The findings inform future quality initiatives to improve sedation practices.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJETIVO: Avaliar as alterações morfológicas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados, sob ventilação com tubo traqueal (TT) ou máscara laríngea (ML). MÉTODOS: Doze cães adultos foram divididos aleatoriamente em dois grupos: grupo TT (n-6) e grupo ML (n-6), submetidos à anestesia venosa e ventilação mecânica, em sistema sem reabsorção de CO2. Foram registrados parâmetros hemodinâmicos e ventilatórios, temperatura timpânica, temperatura, umidade relativa e absoluta do ar ambiente e dos gases inalados durante 3 horas. Ao término do experimento, os animais foram submetidos a eutanásia e realizadas biópsias ao longo do segmento traqueal para estudo morfológico. Três cães saudáveis foram utilizados para controle morfológico. RESULTADOS: A temperatura dos gases inalados manteve-se entre 24ºC e 26ºC, a umidade relativa entre 10% e 12%, e umidade absoluta entre 2 -3 mg H2O.L-1 sem diferença significativa entre os grupos. em ambos os grupos a análise histológica evidenciou processo inflamatório epitelial e congestão no córion, e a microscopia eletrônica de varredura mostrou agrupamento e desorganização ciliar. A microscopia eletrônica de transmissão detectou maiores alterações no grupo TT do que no ML, como alargamento das junções intercelulares, desorientação ciliar, vacuolização citoplasmática, alterações nucleares como pcinose e condensação da cromatina. CONCLUSÃO: A máscara laríngea determinou alterações menos pronunciadas no epitélio traqueal de cães expostos à inalação de gases pouco condicionados.