880 resultados para Point-of-care systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cardiac troponins (cTn) I and T are the current golden standard biochemical markers in the diagnosis and risk stratification of patients with suspected acute coronary syndrome. During the past few years, novel assays capable of detecting cTn‐concentrations in >50% of apparently healthy individuals have become readily available. With the emerging of these high sensitivity cTn assays, reductions in the assay specificity have caused elevations in the measured cTn levels that do not correlate with the clinical picture of the patient. The increased assay sensitivity may reveal that various analytical interference mechanisms exist. This doctoral thesis focused on developing nanoparticle‐assisted immunometric assays that could possibly be applied to an automated point‐of‐care system. The main objective was to develop minimally interference‐prone assays for cTnI by employing recombinant antibody fragments. Fast 5‐ and 15‐minute assays for cTnI and D‐dimer, a degradation product of fibrin, based on intrinsically fluorescent nanoparticles were introduced, thus highlighting the versatility of nanoparticles as universally applicable labels. The utilization of antibody fragments in different versions of the developed cTnI‐assay enabled decreases in the used antibody amounts without sacrificing assay sensitivity. In addition, the utilization of recombinant antibody fragments was shown to significantly decrease the measured cTnI concentrations in an apparently healthy population, as well as in samples containing known amounts of potentially interfering factors: triglycerides, bilirubin, rheumatoid factors, or human anti‐mouse antibodies. When determining the specificity of four commercially available antibodies for cTnI, two out of the four cross‐reacted with skeletal troponin I, but caused crossreactivity issues in patient samples only when paired together. In conclusion, the results of this thesis emphasize the importance of careful antibody selection when developing cTnI assays. The results with different recombinant antibody fragments suggest that the utilization of antibody fragments should strongly be encouraged in the immunoassay field, especially with analytes such as cTnI that require highly sensitive assay approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point-of-care (POC) –diagnostics is a field with rapidly growing market share. As these applications become more widely used, there is an increasing pressure to improve their performance to match the one of a central laboratory tests. Lanthanide luminescence has been widely utilized in diagnostics because of the numerous advantages gained by the utilization of time-resolved or anti-Stokes detection. So far the use of lanthanide labels in POC has been scarce due to limitations set by the instrumentation required for their detection and the shortcomings, e.g. low brightness, of these labels. Along with the advances in the research of lanthanide luminescence, and in the field of semiconductors, these materials are becoming a feasible alternative for the signal generation also in the future POC assays. The aim of this thesis was to explore ways of utilizing time-resolved detection or anti-Stokes detection in POC applications. The long-lived fluorescence for the time-resolved measurement can be produced with lanthanide chelates. The ultraviolet (UV) excitation required by these chelates is cumbersome to produce with POC compatible fluorescence readers. In this thesis the use of a novel light-harvesting ligand was studied. This molecule can be used to excite Eu(III)-ions at wavelengths extending up to visible part of the spectrum. An enhancement solution based on this ligand showed a good performance in a proof-of-concept -bioaffinity assay and produced a bright signal upon 365 nm excitation thanks to the high molar absorptivity of the chelate. These features are crucial when developing miniaturized readers for the time-resolved detection of fluorescence. Upconverting phosphors (UCPs) were studied as an internal light source in glucose-sensing dry chemistry test strips and ways of utilizing their various emission wavelengths and near-infrared excitation were explored. The use of nanosized NaYF :Yb3+,Tm3+-particles enabled the replacement of an external UV-light source with a NIR-laser and gave an additional degree of freedom in the optical setup of the detector instrument. The new method enabled a blood glucose measurement with results comparable to a current standard method of measuring reflectance. Microsized visible emitting UCPs were used in a similar manner, but with a broad absorbing indicator compound filtering the excitation and emission wavelengths of the UCP. This approach resulted in a novel way of benefitting from the non-linear relationship between the excitation power and emission intensity of the UCPs, and enabled the amplification of the signal response from the indicator dye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Termiä sepsis käytetään infektion aiheuttamasta yleisestä tulehdusreaktio-oireyhtymästä. Biokemiallinen merkkiaine eli biomarkkeri on aine, joka objektiivisesti mitattuna ja arvioituna toimii indikaattorina erottaen toisistaan normaalit biologiset prosessit ja patogeeniset prosessit. Lisäksi biomarkkeri saattaa osoittaa farmakologisen vasteen lääkehoidolle. Tutkielman kirjallisessa osassa on esitelty ja verrattu toisiinsa jo kliinisessä käytössä olevia sekä lupaavia, vielä tutkimusvaiheessa olevia, sepsiksen biomerkkiaineita. Lisäksi tutkielmassa on tarkasteltu sepsiksen todentamisen, tunnistamisen ja hoidon tulevaisuudennäkymiä. Prokalsitoniini (PCT) on eräs jo kliinisessä käytössä oleva sepsiksen biomerkkiaine. Tutkielman kokeellisessa osassa pystytettiin teho-osastoille suunnattu pikatesti PCT:n mittaamiseen aikaerotteista fluoresenssiteknologiaa hyödyntävälle AQT-järjestelmälle (DHR Finland Oy, Innotrac Diagnostics, Suomi). Järjestelmä mittaa 20–30 minuutissa biomerkkiainepitoisuuden. Tavoitteena oli löytää sopiva vasta-ainepari ja pystyttää kaksipuoleinen immunomääritys, jonka analyyttinen herkkyys on alle 0,02 ng/ml:ssa. Työssä tutkittiin biotinyloidun kokonaisen vasta-aineen ja paikkaspesifisesti biotinyloidun antigeenia sitovan fragmentin (engl. fragment antigen binding, Fab) toimivuutta sitojamolekyylinä. Lisäksi työssä verrattiin kahden eri leimamolekyylin, 9 hampaisen europiumkelaatin sekä Innotracissa kehitetyn tähtikelaatin, toimivuutta PCT-immunomäärityksessä. Vasta-aineiden mahdolliset ristireaktiot testattiin ja määritystä testattiin alustavasti eri näytematriiseissa. Työssä löydettiin 5 vasta-aineparia, joiden analyyttinen herkkyys oli alle 0,02 ng/ml:ssa. Aiemmin testattuja vasta-ainepareja parempi analyyttinen herkkyys johtui todennäköisesti yhden uuden leimavasta-aineen paremmasta affiniteetistä. Tähtikelaatilla leimatulla vasta-aineella analyyttinen herkkyys parani lähes viisinkertaisesti, kun sitä verrattiin 9-hampaisella euroopiumkelaatilla leimatun vasta-aineen määritykseen. Havaittiin myös, että Fab-fragmentilla mitattiin määrityksissä lähes kaksi kertaa suuremmat signaali-taustasuhteet, kun sitä verrattiin kokonaiseen vasta-aineeseen, tietyllä vasta-aineparilla. Tämä johtui luultavasti steeristen esteiden vähenemisestä. Näytematriisilla ei todettu olevan vaikutusta määritykseen, eikä ristireaktioita havaittu. Kehitetyn määrityksen suoriutumista verrattiin markkinoilla olevaan BRAHMS AG:n (Saksa) PCT-määritykseen käyttäen potilasnäytteitä. Korrelaatiokertoimet potilasnäytevertailuissa olivat 0,965–0,989 ja näytteiden mitatuissa pitoisuuksissa oli tasoero.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The conventional Newton and fast decoupled power flow (FDPF) methods have been considered inadequate to obtain the maximum loading point of power systems due to ill-conditioning problems at and near this critical point. It is well known that the PV and Q-theta decoupling assumptions of the fast decoupled power flow formulation no longer hold in the vicinity of the critical point. Moreover, the Jacobian matrix of the Newton method becomes singular at this point. However, the maximum loading point can be efficiently computed through parameterization techniques of continuation methods. In this paper it is shown that by using either theta or V as a parameter, the new fast decoupled power flow versions (XB and BX) become adequate for the computation of the maximum loading point only with a few small modifications. The possible use of reactive power injection in a selected PV bus (Q(PV)) as continuation parameter (mu) for the computation of the maximum loading point is also shown. A trivial secant predictor, the modified zero-order polynomial which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used in predictor step. These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approach for the IEEE test systems (14, 30, 57 and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that parameters can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The parameterized fast decoupled power flow (PFDPF), versions XB and BX, using either theta or V as a parameter have been proposed by the authors in Part I of this paper. The use of reactive power injection of a selected PVbus (Q(PV)) as the continuation parameter for the computation of the maximum loading point (MLP) was also investigated. In this paper, the proposed versions obtained only with small modifications of the conventional one are used for the computation of the MLP of IEEE test systems (14, 30, 57 and 118 buses). These new versions are compared to each other with the purpose of pointing out their features, as well as the influence of reactive power and transformer tap limits. The results obtained with the new approaches are presented and discussed. The results show that the characteristics of the conventional FDPF method are enhanced and the region of convergence around the singular solution is enlarged. In addition, it is shown that these versions can be switched during the tracing process in order to efficiently determine all the PV curve points with few iterations. A trivial secant predictor, the modified zero-order polynomial, which uses the current solution and a fixed increment in the parameter (V, theta, or mu) as an estimate for the next solution, is used for the predictor step. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of antibiotics is highest in primary care and directly associated with antibiotic resistance in the community. We assessed regional variations in antibiotic use in primary care in Switzerland and explored prescription patterns in relation to the use of point of care tests. Defined daily doses of antibiotics per 1000 inhabitants (DDD(1000pd) ) were calculated for the year 2007 from reimbursement data of the largest Swiss health insurer, based on the anatomic therapeutic chemical classification and the DDD methodology recommended by WHO. We present ecological associations by use of descriptive and regression analysis. We analysed data from 1 067 934 adults, representing 17.1% of the Swiss population. The rate of outpatient antibiotic prescriptions in the entire population was 8.5 DDD(1000pd) , and varied between 7.28 and 11.33 DDD(1000pd) for northwest Switzerland and the Lake Geneva region. DDD(1000pd) for the three most prescribed antibiotics were 2.90 for amoxicillin and amoxicillin-clavulanate, 1.77 for fluoroquinolones, and 1.34 for macrolides. Regions with higher DDD(1000pd) showed higher seasonal variability in antibiotic use and lower use of all point of care tests. In regression analysis for each class of antibiotics, the use of any point of care test was consistently associated with fewer antibiotic prescriptions. Prescription rates of primary care physicians showed variations between Swiss regions and were lower in northwest Switzerland and in physicians using point of care tests. Ecological studies are prone to bias and whether point of care tests reduce antibiotic use has to be investigated in pragmatic primary care trials.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intraoperative major bleeding is a common complication during surgery and can lead to the transfusion of blood products and/or procoagulant drugs. This is a therapeutic challenge, and adherence to guidelines is desirable to preserve blood product resources. The intraoperative administration of fibrinogen concentrate, a pro-coagulant drug, in bleeding patients might reduce the use and therefore the risks associated with blood products.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two major difficulties arise when taking blood samples in children: the challenge of venous access and the comparatively large amount of blood required.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Point-of-care testing (POCT) remains under scrutiny by healthcare professionals because of its ill-tried, young history. POCT methods are being developed by a few major equipment companies based on rapid progress in informatics and nanotechnology. Issues as POCT quality control, comparability with standard laboratory procedures, standardisation, traceability and round robin testing are being left to hospitals. As a result, the clinical and operational benefits of POCT were first evident for patients on the operating table. For the management of cardiovascular surgery patients, POCT technology is an indispensable aid. Improvement of the technology has meant that clinical laboratory pathologists now recognise the need for POCT beyond their high-throughput areas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The Roche CARDIAC proBNP point-of-care (POC) test is the first test intended for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in whole blood as an aid in the diagnosis of suspected congestive heart failure, in the monitoring of patients with compensated left-ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes. METHODS: A multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP test at seven different sites. RESULTS: The majority of all coefficients of variation (CVs) obtained for within-series imprecision using native blood samples was below 10% for both 52 samples measured ten times and for 674 samples measured in duplicate. Using quality control material, the majority of CV values for day-to-day imprecision were below 14% for the low control level and below 13% for the high control level. In method comparisons for four lots of the POC NT-proBNP test with the laboratory reference method (Elecsys proBNP), the slope ranged from 0.93 to 1.10 and the intercept ranged from 1.8 to 6.9. The bias found between venous and arterial blood with the POC NT-proBNP method was < or =5%. All four lots of the POC NT-proBNP test investigated showed excellent agreement, with mean differences of between -5% and +4%. No significant interference was observed with lipaemic blood (triglyceride concentrations up to 6.3 mmol/L), icteric blood (bilirubin concentrations up to 582 micromol/L), haemolytic blood (haemoglobin concentrations up to 62 mg/L), biotin (up to 10 mg/L), rheumatoid factor (up to 42 IU/mL), or with 50 out of 52 standard or cardiological drugs in therapeutic concentrations. With bisoprolol and BNP, somewhat higher bias in the low NT-proBNP concentration range (<175 ng/L) was found. Haematocrit values between 28% and 58% had no influence on the test result. Interference may be caused by human anti-mouse antibodies (HAMA) types 1 and 2. No significant influence on the results with POC NT-proBNP was found using volumes of 140-165 muL. High NT-proBNP concentrations above the measuring range of the POC NT-proBNP test did not lead to false low results due to a potential high-dose hook effect. CONCLUSIONS: The POC NT-proBNP test showed good analytical performance and excellent agreement with the laboratory method. The POC NT-proBNP assay is therefore suitable in the POC setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Bleeding is a frequent complication during surgery. The intraoperative administration of blood products, including packed red blood cells, platelets and fresh frozen plasma (FFP), is often live saving. Complications of blood transfusions contribute considerably to perioperative costs and blood product resources are limited. Consequently, strategies to optimize the decision to transfuse are needed. Bleeding during surgery is a dynamic process and may result in major blood loss and coagulopathy due to dilution and consumption. The indication for transfusion should be based on reliable coagulation studies. While hemoglobin levels and platelet counts are available within 15 minutes, standard coagulation studies require one hour. Therefore, the decision to administer FFP has to be made in the absence of any data. Point of care testing of prothrombin time ensures that one major parameter of coagulation is available in the operation theatre within minutes. It is fast, easy to perform, inexpensive and may enable physicians to rationally determine the need for FFP. METHODS/DESIGN: The objective of the POC-OP trial is to determine the effectiveness of point of care prothrombin time testing to reduce the administration of FFP. It is a patient and assessor blind, single center randomized controlled parallel group trial in 220 patients aged between 18 and 90 years undergoing major surgery (any type, except cardiac surgery and liver transplantation) with an estimated blood loss during surgery exceeding 20% of the calculated total blood volume or a requirement of FFP according to the judgment of the physicians in charge. Patients are randomized to usual care plus point of care prothrombin time testing or usual care alone without point of care testing. The primary outcome is the relative risk to receive any FFP perioperatively. The inclusion of 110 patients per group will yield more than 80% power to detect a clinically relevant relative risk of 0.60 to receive FFP of the experimental as compared with the control group. DISCUSSION: Point of care prothrombin time testing in the operation theatre may reduce the administration of FFP considerably, which in turn may decrease costs and complications usually associated with the administration of blood products. TRIAL REGISTRATION: NCT00656396.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.