937 resultados para Peak Expiratory Flow Rate


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Backgroud: The aim was to study the prevalence of respiratory symptoms and assess the lung function of fish smokers in Nigeria. Methods: A case control study was done among fish smokers in Nigeria. Women aged 15 years or older (n=210) involved in fish smoking and equal number of matched controls were interviewed on respiratory symptoms and their peak expiratory flow rate (PEFR) measured. Data was analysed using chi square test, student\'s t-test and odd ratios. Results: Both groups were similar in their personal characteristics. The test group had significantly increased occurrence of sneezing (153; 72.86%), catarrh (159; 75.71%), cough (138; 65.71%) and chest pain (59; 28.10%) compared with the control group, odds ratio (OR) 2.49, 95% confidence interval CI (1.62-3.82), P < 0.001), OR 3.77,95% CI (2.44- 5.85), P < 0.001, OR 3.38, 95% CI (2.22-5.15), P < 0.001, and OR 6.45,95% CI (3.22-13.15), P < 0.001, respectively. The mean PEFR of 321±58.93 L/min among the fish smokers was significantly lower than 400±42.92 L/min among the controls (p = 0.0001). Conclusion: Fish smokers have increased risk of respiratory symptoms and reduced pulmonary function. There is a need for protective equipment and periodic evaluation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resumo Objectivos: Avaliação da Tosse em doentes com Doença Pulmonar Obstrutiva Crónica (DPOC). Identificar e determinar a relação dos factores preditivos que contribuem para a deterioração da capacidade de tosse nestes indivíduos. Tipo de estudo: Estudo observacional descritivo de natureza transversal. Definição dos casos: Os critérios de diagnóstico da DPOC são o quadro clínico e o Gold standard para diagnóstico da DPOC – a espirometria. População-alvo: Todos os utentes com patologia primária de DPOC diagnosticada que se desloquem ao serviço de função respiratória do Hospital de Viseu, para realizar provas. Método de Amostragem: Foi utilizada uma amostra aleatória constituída por todos os indivíduos, que cumpriram os critérios de inclusão, conscientes e colaborantes, que aceitaram participar neste estudo. Dimensão da amostra: Uma amostra de 55 indivíduos que se deslocaram ao serviço de função respiratória, entre Janeiro e Junho de 2009, para realizar provas de função respiratória. Condução do estudo: Os utentes que aceitaram participar neste estudo foram sujeitos a um questionário de dados clínicos e realizaram 5 testes: índice de massa corporal (IMC), estudo funcional respiratório e gasometria arterial, avaliação da força dos músculos respiratórios (PImax e PEmax) e avaliação do débito máximo da tosse (Peak Cough Flow). Análise estatística: Foram obtidos dados caracterizadores da amostra em estudo, sendo posteriormente correlacionado o valor de débito máximo da tosse (Peak Cough Flow) com os resultados obtidos para as avaliações do IMC, estudo funcional respiratório, PImax e PEmax, gasometria, avaliação da capacidade de Tosse e número de internamentos no último ano por agudização da DPOC. Tendo sido encontrados os valores de correlação entre o Peak Cough Flow e os restantes parâmetros. Resultados: Após análise dos resultados, foram obtidos os valores de Peak Cough Flow para a população com DPOC e verificou-se valores diminuídos em comparação com os valores normais da população, tendo-se verificado maiores valores de PCF em indivíduos do sexo masculino, em comparação aos valores do sexo feminino. Foi analisada a relação entre o PCF e a idade, peso, altura e IMC, não tendo sido encontrada relação, dado que a tosse não apresenta uma variação segundo os valores antropométricos, tal como a relação com os valores espirométricos. Quanto aos parâmetros funcionais respiratórios foram analisadas as relações com o PCF. Verificou-se relações significativas entre o PCF e o FEV1, a FVC, o PEF, apresentando uma relação positiva, onde maiores valores destes parâmetros estão correlacionados com maiores picos de tosse. Quanto a RAW e RV, o PCF apresenta uma relação negativa, onde uma maior resistência da via aérea ou doentes mais hiperinsuflados leva a menores valores de PCF. Por outro lado não foi encontrada relação entre o PCF e a FRC e o TLC. Quanto à força dos músculos respiratórios, verificou-se relação significativa com o PImax e a PEmax em que a fraqueza ao nível dos músculos respiratórios contribuem para um menor valor de PCF. Relativamente aos valores da gasometria arterial, verificou-se relação entre o PCF e a PaO2 de forma positiva, em que doentes hipoxémicos apresentam menores valores de tosse, e a PaCO2, de forma negativa, em que os doentes hipercápnicos apresentam menores valores de PCF tendo sido verificada relação entre o PCF e o pH e sO2. Quanto à relação entre o número de internamentos por agudização da DPOC no último ano e o PCF verificou-se uma relação significativa, onde um menor valor de PCF contribui para uma maior taxa de internamento por agudização da DPOC. Conclusão: Este conjunto de conclusões corrobora a hipótese inicialmente formulada, de que o Peak Cough Flow se encontra diminuído nos indivíduos com Doença Pulmonar Obstrutiva Crónica onde a variação do PCF se encontra directamente relacionada com os parâmetros funcionais respiratórios, com a força dos músculos respiratórios e com os valores de gasometria arterial. ABSTRACT: Aims: Cough evaluation in Chronic Obstructive Pulmonary Disease (COPD) patients. Identify and determine the relation of the predictive factors that contribute to the cough capacity degradation in this type of patients. Type of study: Descriptive observational study of transversal nature. Case definition: The COPD diagnosis criteria are the clinical presentation and the gold standard to the COPD diagnosis- the Spirometry. Target Population: Every patients, with primary pathology of COPD diagnosed, who went to the respiratory function service of Viseu hospital to perform tests. Sampling Method: It was used a random sample constituted by all the, conscious and cooperating individuals, who complied with the inclusion criteria and who accepted to make part of this study. Sample size: A sample of 55 individuals that went to the respiratory function service between January and June 2009 to perform respiratory function tests. Study: The patients who accepted to make part of this study were submitted to a clinical data questionary and performed 5 tests: body mass index (BMI), respiratory functional study, arterial blood gas level, evaluation of respiratory muscles strength (maximal inspiratory pressure (MIP) and maximum expiratory pressure (MEP)), and Peak Cough Flow evaluation. Statistic Analysis: Were obtained characterizing data of the sample in study, and later correlated the value of the Peak Cough Flow with the results from the evaluation of the body mass index (BMI), the respiratory functional study the MIP and MEP, the arterial blood gas level and also with the ability to cough evaluation and the number of hospitalizations in the last year for COPD exacerbations. The values of correlation between the Peak Cough Flow and the other parameters were found. Results: After analyzing the results, were obtained the values of Peak Cough Flow for the population with COPD. There were decreased values compared with the population normal values, having been found higher values of PCF in males compared to female values. It was analyzed the relation between the PCF and the age, weight, height and BMI but no relation was found on account of the fact that the cough does not show a variation according to anthropometric parameters, such as the relation with spirometric values. As for the respiratory functional parameters were analyzed relations with the PCF. There were significant relations between the PCF and FEV1, the FVC, the PEF, presenting a positive relation, where higher values of these parameters are correlated with higher incidence of cough. Concerning the RAW and RV, the PCF has a negative relation, in which a higher airway resistance or in more hyperinflated patients, leads to lower values of PCF. On the other hand no correlation was found between the PCF and the FRC and TLC. Regarding the respiratory muscle strength, there was a significant relation with the MIP and MEP, in which the weakness at the level of respiratory muscles contribute to a lower value of PCF. For values of arterial blood gas level, there was no relation between the PCF and PaO2, in a positive way, in which patients with hypoxemia present lower values of cough, and PaCO2, in a negative way in which hypercapnic patients had lower values of PCF, having being founded a relation between the PCF and the pH and sO2. As for the relation between the number of hospitalizations for COPD exacerbation in the last year and the PCF was found a significant relation, in which a smaller value of PCF contributes to a higher rate of hospitalization for COPD exacerbation. Conclusion: This set of findings supports the hypothesis first formulated that Peak Cough Flow is decreased in individuals with Chronic Obstructive Pulmonary Disease, in which the variation of the PCF is directly related to the respiratory function parameters, the strength of respiratory muscles and the values of arterial blood gases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess positive end-expiratory pressure (PEEP)-induced lung overdistension and alveolar recruitment in six patients with acute lung injury (ALI) using a computed tomographic (CT) scan method. Lung overdistension was first determined in six healthy volunteers in whom CT sections were obtained at FRC and at TLC with a positive airway pressure of 30 cm H2O. In patients, lung volumes were quantified by the analysis of the frequency distribution of CT numbers on the entire lung at zero end-expiratory pressure (ZEEP) and PEEP. In healthy volunteers at FRC, the distribution of the density histograms was monophasic with a peak at -791 ± 12 Hounsfield units (HU). The lowest CT number observed was -912 HU. At TLC, lung volume increased by 79 ± 35% and the peak CT number decreased to -886 ± 26 HU. More than 70% of the increase in lung volume was located below -900 HU, suggesting that this value can be considered as the threshold separating normal aeration from overdistension. In patients with ALI, at ZEEP the distribution of density histograms was either monophasic (n = 3) or biphasic (n = 3). The mean CT number was -319 ± 34 HU. At PEEP 13 ± 3 cm H2O, lung volume increased by 47 ± 19% whereas mean CT number decreased to -538 ± 171 HU. PEEP induced a mean alveolar recruitment of 320 ± 160 ml and a mean lung overdistension of 238 ± 320 ml. In conclusion, overdistended lung parenchyma of healthy volunteers is characterized by a CT number below -900 HU. This threshold can be used in patients with ALI for differentiating PEEP-induced alveolar recruitment from lung overdistension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For many people, a relatively large proportion of daily exposure to a multitude of pollutants may occur inside an automobile. A key determinant of exposure is the amount of outdoor air entering the cabin (i.e. air change or flow rate). We have quantified this parameter in six passenger vehicles ranging in age from 18 years to <1 year, at three vehicle speeds and under four different ventilation settings. Average infiltration into the cabin with all operable air entry pathways closed was between 1 and 33.1 air changes per hour (ACH) at a vehicle speed of 60 km/h, and between 2.6 and 47.3 ACH at 110 km/h, with these results representing the most (2005 Volkswagen Golf) and least air-tight (1989 Mazda 121) vehicles, respectively. Average infiltration into stationary vehicles parked outdoors varied between ~0 and 1.4 ACH and was moderately related to wind speed. Measurements were also performed under an air recirculation setting with low fan speed, while airflow rate measurements were conducted under two non-recirculate ventilation settings with low and high fan speeds. The windows were closed in all cases, and over 200 measurements were performed. The results can be applied to estimate pollutant exposure inside vehicles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To determine smoking patterns in South Africa, and to identify groups requiring culturally appropriate smoking cessation programmes. Methods A random sample of 13 826 people (415 years), was interviewed to identify tobacco use patterns and respiratory symptoms. Peak expiratory flow rates were measured. Multinomial regression analyses identified sociodemographic factors related to tobacco use, and the latter’s association with respiratory conditions. Results In 1998, 24.6% adults (44.2% of males and 11.0% of females) smoked regularly. Coloured women had a higher rate (39%) than African women (5.4%). About 24% of the regular smokers had attempted to quit, with only 9.9% succeeding. African women (13.2%) used smokeless tobacco more frequently than others. Of the nonsmokers 28% and 19% were exposed to environmental tobacco smoke in their homes and workplaces, respectively. The regression analysis showed that the demographic characteristics of light smokers (1–14 tobacco equivalents per day) and heavy smokers (>=15 tobacco equivalents per day) differed. Light smoking occurred significantly more frequently in the poorest, least educated and urban people. The relative risk for light smoking was 18 in Coloured women compared with African women. Heavy smoking occurred most frequently in the highest educated group. A dose–response was observed between the amount smoked and the presence of respiratory diseases. Conclusions Smoking in South Africa is decreasing and should continue with the recently passed tobacco control legislation. Culturally appropriate tobacco cessation programmes for the identified target groups need to be developed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Lagrangian particle tracking provides an effective method for simulating the deposition of nano- particles as well as micro-particles as it accounts for the particle inertia effect as well as the Brownian excitation. However, using the Lagrangian approach for simulating ultrafine particles has been limited due to computational cost and numerical difficulties. The aim of this paper is to study the deposition of nano-particles in cylindrical tubes under laminar condition using the Lagrangian particle tracking method. The commercial Fluent software is used to simulate the fluid flow in the pipes and to study the deposition and dispersion of nano-particles. Different particle diameters as well as different pipe lengths and flow rates are examined. The results show good agreement between the calculated deposition efficiency and different analytic correlations in the literature. Furthermore, for the nano-particles with higher diameters and when the effect of inertia has a higher importance, the calculated deposition efficiency by the Lagrangian method is less than the analytic correlations based on Eulerian method due to statistical error or the inertia effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The mass flow rate, (m) over dot, associated with the lateral outflow of dry, cohesionless granular material through circular orifices of diameter D made in vertical walls of silos was measured experimentally in order to determine also the influence of the wall thickness of the silo, w. Geometrical arguments, based on the outflow happening, are given in order to have a general correlation for (m) over dot embracing both quantities, D and w. The angle of repose appears to be an important characterization factor in these kinds of flows.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

HfO2 thin films deposited on Si substrate using electron beam evaporation, are evaluated for back-gated graphene transistors. The amount of O-2 flow rate, during vaporation is optimized for 35 nm thick HfO2 films, to achieve the best optical, chemical and electrical properties. It has been observed that with increasing oxygen flow rate, thickness of the films increased and refractive index decreased due to increase in porosity resulting from the scattering of the evaporant. The films deposited at low O-2 flow rates (1 and 3 SCCM) show better optical and compositional properties. The effects of post-deposition annealing and post-metallization annealing in forming gas ambience (FGA) on the optical and electrical properties of the films have been analyzed. The film deposited at 3 SCCM O-2 flow rate shows the best properties as measured on MOS capacitors. To evaluate the performance of device properties, back-gated bilayer graphene transistors on HfO2 films deposited at two O-2 flow rates of 3 and 20 SCCM have been fabricated and characterized. The transistor with HfO2 film deposited at 3 SCCM O-2 flow rate shows better electrical properties consistent with the observations on MOS capacitor structures. This suggests that an optimum oxygen pressure is necessary to get good quality films for high performance devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

对涡轮流量传感器进行了理论分析,给出了涡轮流量计仪表常数的计算方法,讨论了获得较大固有仪表常数K_0时涡轮传感器结构参数(如叶片数、涡轮半径、口径等)的优化组合问题,通过多相流动实验,总结出K_0与流动密度之间的实验关系,由此给出用涡轮流量计测量多相流的半理论半经验公式,并在油井多相流量测量中得到了实际应用,符合较好。

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Market competitiveness for aero engine power plant dictates that improvements in engine performance and reliability are guaranteed a priori by manufacturers. The requirement to accurately predict the life of engine components makes exacting demands of the internal air system, which must provide effective cooling over the engine duty cycle with the minimum consumption of compressor section air. Tests have been conducted at the University of Sussex using a turbine test facility which comprises a two stage turbine with an individual stage pressure ratio of 1.7:1. Main annulus air is supplied by an adapted Rolls-Royce Dart compressor at up to 440 K and 4.8 kg s-1. Cooling flow rates ranging from 0.71 to 1.46 Cw, ent, a disc entrainment parameter, have been used to allow ingress or egress dominated stator well flow conditions. The mechanical design of the test section allows internal cooling geometry to be rapidly re-configured, allowing the effect of jet momentum and coolant trajectory to be investigated. An important facet to this investigation is the use of CFD to model and analyse the flow structures associated with the cavity conditions tested, as well as to inform the design of cooling path geometry. This paper reports on the effectiveness of stator well coolant flow rate and delivery configurations using experimental data and also CFD analysis to better quantify the effect of stator well flow distribution on component temperatures. Copyright © 2011 by Rolls-Royce plc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vertically oriented GaAs nanowires (NWs) are grown on Si(111) substrates using metal-organic chemical vapor deposition. Controlled epitaxial growth along the 111 direction is demonstrated following the deposition of thin GaAs buffer layers and the elimination of structural defects, such as twin defects and stacking faults, is found for high growth rates. By systematically manipulating the AsH 3 (group-V) and TMGa (group-III) precursor flow rates, it is found that the TMGa flow rate has the most significant effect on the nanowire quality. After capping the minimal tapering and twin-free GaAs NWs with an AlGaAs shell, long exciton lifetimes (over 700ps) are obtained for high TMGa flow rate samples. It is observed that the Ga adatom concentration significantly affects the growth of GaAs NWs, with a high concentration and rapid growth leading to desirable characteristics for optoelectronic nanowire device applications including improved morphology, crystal structure and optical performance. © 2012 IOP Publishing Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As reported by other authors, we have also observed that the Si growth rate decreases with increasing phosphine (PH3) flow rate in gas source-Si molecular beam epitaxy using phosphorous (P) as a n-type dopant. Why small quantity PH3 can affect Si growth rate? Up to now, the quantitative characterization of PH3 flow influence on Si growth rate is little known. In this letter, the PH, influence will be analyzed in detail and a model considering strong P surface segregation and its absorption of hydrogen will be proposed to characterize the effect. (C) 2000 Elsevier Science B.V. All rights reserved.