940 resultados para Parallel hot-wire method
Resumo:
Amorphous silicon n-i-p solar cells have been fabricated entirely by Hot-Wire Chemical Vapour Deposition (HW-CVD) at low process temperature < 150 °C. A textured-Ag/ZnO back reflector deposited on Corning 1737F by rf magnetron sputtering was used as the substrate. Doped layers with very good conductivity and a very less defective intrinsic a-Si:H layer were used for the cell fabrication. A double n-layer (μc-Si:H/a-Si:H) and μc-Si:H p-layer were used for the cell. In this paper, we report the characterization of these layers and the integration of these layers in a solar cell fabricated at low temperature. An initial efficiency of 4.62% has been achieved for the n-i-p cell deposited at temperatures below 150 °C over glass/Ag/ZnO textured back reflector.
Resumo:
Hydrogenated nanocrystalline silicon (nc-Si:H) obtained by hot-wire chemical vapour deposition (HWCVD) at low substrate temperature (150 °C) has been incorporated as the active layer in bottom-gate thin-film transistors (TFTs). These devices were electrically characterised by measuring in vacuum the output and transfer characteristics for different temperatures. The field-effect mobility showed a thermally activated behaviour which could be attributed to carrier trapping at the band tails, as in hydrogenated amorphous silicon (a-Si:H), and potential barriers for the electronic transport. Trapped charge at the interfaces of the columns, which are typical in nc-Si:H, would account for these barriers. By using the Levinson technique, the quality of the material at the column boundaries could be studied. Finally, these results were interpreted according to the particular microstructure of nc-Si:H.
Resumo:
Polysilicon thin film transistors (TFT) are of great interest in the field of large area microelectronics, especially because of their application as active elements in flat panel displays. Different deposition techniques are in tough competition with the objective to obtain device-quality polysilicon thin films at low temperature. In this paper we present the preliminary results obtained with the fabrication of TFT deposited by hot-wire chemical vapor deposition (HWCVD). Some results concerned with the structural characterization of the material and electrical performance of the device are presented.
Resumo:
Hydrogenated microcrystalline silicon films obtained at low temperature (150-280°C) by hot wire chemical vapour deposition at two different process pressures were measured by Raman spectroscopy, X-ray diffraction (XRD) spectroscopy and photothermal deflection spectroscopy (PDS). A crystalline fraction >90% with a subgap optical absortion 10 cm -1 at 0.8 eV were obtained in films deposited at growth rates >0.8 nm/s. These films were incorporated in n-channel thin film transistors and their electrical properties were measured. The saturation mobility was 0.72 ± 0.05 cm 2/ V s and the threshold voltage around 0.2 eV. The dependence of their conductance activation energies on gate voltages were related to the properties of the material.
Microdoping compensation of microcrystalline silicon obtained by Hot-Wire Chemical Vapour Deposition
Resumo:
Undoped hydrogenated microcrystalline silicon was obtained by hot-wire chemical vapour deposition at different silane-to-hydrogen ratios and low temperature (<300 °C). As well as technological aspects of the deposition process, we report structural, optical and electrical characterizations of the samples that were used as the active layer for preliminary p-i-n solar cells. Raman spectroscopy indicates that changing the hydrogen dilution can vary the crystalline fraction. From electrical measurements an unwanted n-type character is deduced for this undoped material. This effect could be due to a contaminant, probably oxygen, which is also observed in capacitance-voltage measurements on Schottky structures. The negative effect of contaminants on the device was dramatic and a compensated p-i-n structure was also deposited to enhance the cell performance.
Resumo:
Lo studio della turbolenza è di fondamentale importanza non solo per la fluidodinamica teorica ma anche perchè viene riscontrata in una moltitudine di problemi di interesse ingegneristico. All'aumentare del numero di Reynolds, le scale caratteristiche tendono a ridurre le loro dimensioni assolute. Nella fluidodinamica sperimentale già da lungo tempo si è affermata l'anemometria a filo caldo, grazie ad ottime caratteristiche di risoluzione spaziale e temporale. Questa tecnica, caratterizzata da un basso costo e da una relativa semplicità, rende possibile la realizzazione di sensori di tipo artigianale, che hanno il vantaggio di poter essere relizzati in dimensioni inferiori. Nonostante l'ottima risoluzione spaziale degli hot-wire, infatti, si può verificare, ad alto numero di Reynolds, che le dimensioni dell'elemento sensibile siano superiori a quelle delle piccole scale. Questo impedisce al sensore di risolvere correttamente le strutture più piccole. Per questa tesi di laurea è stato allestito un laboratorio per la costruzione di sensori a filo caldo con filo di platino. Sono in questo modo stati realizzati diversi sensori dalle dimensioni caratteristiche inferiori a quelle dei sensori disponibili commercialmente. I sensori ottenuti sono quindi stati testati in un getto turbolento, dapprima confrontandone la risposta con un sensore di tipo commerciale, per verificarne il corretto funzionamento. In seguito si sono eseguite misure più specifiche e limitate ad alcune particolari zone all'interno del campo di moto, dove è probabile riscontrare effetti di risoluzione spaziale. Sono stati analizzati gli effetti della dimensione fisica del sensore sui momenti statistici centrali, sugli spettri di velocità e sulle funzioni di densità di probabilità.
Resumo:
A way to investigate turbulence is through experiments where hot wire measurements are performed. Analysis of the in turbulence of a temperature gradient on hot wire measurements is the aim of this thesis work. Actually - to author's knowledge - this investigation is the first attempt to document, understand and ultimately correct the effect of temperature gradients on turbulence statistics. However a numerical approach is used since instantaneous temperature and streamwise velocity fields are required to evaluate this effect. A channel flow simulation at Re_tau = 180 is analyzed to make a first evaluation of the amount of error introduced by temperature gradient inside the domain. Hot wire data field is obtained processing the numerical flow field through the application of a proper version of the King's law, which connect voltage, velocity and temperature. A drift in mean streamwise velocity profile and rms is observed when temperature correction is performed by means of centerline temperature. A correct mean velocity pro�le is achieved correcting temperature through its mean value at each wall normal position, but a not negligible error is still present into rms. The key point to correct properly the sensed velocity from the hot wire is the knowledge of the instantaneous temperature field. For this purpose three correction methods are proposed. At the end a numerical simulation at Re_tau =590 is also evaluated in order to confirm the results discussed earlier.
Resumo:
L'obiettivo primario di questo elaborato di tesi è quello di stimare l'effetto della risoluzione spaziale e quindi della lunghezza finita del sensore di un anemometro a filo caldo, sul calcolo delle derivate che contribuiscono a valutare la dissipazione.
Resumo:
A body with a shape similar to a hot wire with its sheath, but no prongs, has been placed close to the wall of a turbulent channel at Re_tau = 600. The results of the channel flow, without the wire, agree with previous published ones, despite the modest resolution and domain size. A simplified, two-dimensional version of the wire at the same Reynolds number has been studied to compare the dynamic response of cold and hot wires, where a slightly bigger perturbation is seen in the hot case, but an almost identical dynamic response. The cold wire seems to be able to measure instantaneous velocity with total drag after proper calibration. Being a DNS, the complete description of the flow field around the wire is obtained.
Resumo:
Photocopy.
Resumo:
Abstract not available
Resumo:
The study of turbulence is also nowadays a problem that does not have solution from the mathematical point of view due to the lack of solution to link the mean part of the flow with the fluctuating one. To solve this problem, in the CICLoPE laboratory of Predappio, experiments on different type of jets are performed in order to derive a closure model able to close our mathematical model. One of the most interesting type of jet that could be studied is the planar turbulent free jet which is a two dimensional canonical jet characterized by the self-similarity condition of the velocity profiles. To study this particular jet, a new facility was built. The aim of this project is to characterize the jet at different distances from the nozzle exit, for different values of Reynolds number, to demonstrate that the self-similarity condition is respected. To do that, the evaluation of quantities such as spreading rate, centerline velocity decay and relation between fluctuations and mean part of the flow has to be obtain. All these parameters could be detected thanks to the use of single and X hot-wire anemometry with which it is possible to analyzed the fluctuating behaviour of the flow by associating to an electric signal a physical variable expressed in terms of velocity. To justify the data obtain by the measures, a comparison with results coming from the literature has to be shown.
Resumo:
A crescente atenção revelada pelas sociedades nos últimos anos, no que respeita à sustentabilidade energética do planeta, tornou-se o principal impulsionador para o desenvolvimento de formas de exploração de energia que contribuem para a redução dos gases com efeito de estufa. A energia geotérmica de baixa entalpia (Shallow Geothermal Energy–SGE) é um dos tipos de energia verde utilizados para aquecimento e arrefecimento de edifícios. Nas últimas décadas, tem vindo a demonstrar uma elevada eficácia energética e aplicabilidade em diversos países em todo o mundo. Aos sistemas convencionais de exploração abertos e fechados, seguiram-se os sistemas com estruturas de fundações termoactivas. A Suíça e Áustria foram os países pioneiros onde se iniciou a exploração utilizando este tipo de estruturas, primeiro com recurso a lajes de fundo e depois, em 1984, através de estacas. A utilização generalizada de fundações de forma bi-funcional poderá resultar numa compensação sustentável dos seus custos de implementação. No entanto, é necessário conhecer de forma sólida o comportamento geotécnico dos solos face à imposição das diferentes acções térmicas provocadas pelos Sistemas Geotérmicos de Baixa Entalpia. A eficácia dos Ground Energy Systems (GES) está directamente associada à capacidade que os solos apresentam para fornecer ou dissipar calor. O desempenho dos GES e a sua eficiência está ainda por avaliar relativamente às condições existentes em Portugal. As propriedades térmicas dos solos são um desses aspectos, sendo da maior relevância na avaliação do seu desempenho. Nesta dissertação são abordados os diferentes mecanismos de transferência de calor nos solos bem como propriedades térmicas necessárias para a sua caracterização. Apresenta-se também um caso prático, para o qual foi realizada caracterização térmica e posterior modelação numérica de uma estrutura termoactiva, determinando-se os campos de temperaturas máximos e mínimos e os fluxos térmicos provocados pelo seu funcionamento.
Resumo:
This paper proposes conceptual designs of multi-degree(s) of freedom (DOF) compliant parallel manipulators (CPMs) including 3-DOF translational CPMs and 6-DOF CPMs using a building block based pseudo-rigid-body-model (PRBM) approach. The proposed multi-DOF CPMs are composed of wire-beam based compliant mechanisms (WBBCMs) as distributed-compliance compliant building blocks (CBBs). Firstly, a comprehensive literature review for the design approaches of compliant mechanisms is conducted, and a building block based PRBM is then presented, which replaces the traditional kinematic sub-chain with an appropriate multi-DOF CBB. In order to obtain the decoupled 3-DOF translational CPMs (XYZ CPMs), two classes of kinematically decoupled 3-PPPR (P: prismatic joint, R: revolute joint) translational parallel mechanisms (TPMs) and 3-PPPRR TPMs are identified based on the type synthesis of rigid-body parallel mechanisms, and WBBCMs as the associated CBBs are further designed. Via replacing the traditional actuated P joint and the traditional passive PPR/PPRR sub-chain in each leg of the 3-DOF TPM with the counterpart CBBs (i.e. WBBCMs), a number of decoupled XYZ CPMs are obtained by appropriate arrangements. In order to obtain the decoupled 6-DOF CPMs, an orthogonally-arranged decoupled 6-PSS (S: spherical joint) parallel mechanism is first identified, and then two example 6-DOF CPMs are proposed by the building block based PRBM method. It is shown that, among these designs, two types of monolithic XYZ CPM designs with extended life have been presented.
Resumo:
The nature of the molecular structure of plastics makes the properties of such materials markedly temperature dependent. In addition, the continuous increase in the utilization of polymeric materials in many specific applications has demanded knowledge of their physical properties, both during their processing as raw material, as well as over the working temperature range of the final polymer product. Thermal conductivity, thermal diffusivity and specific heat, namely the thermal properties, are the three most important physical properties of a material that are needed for heat transfer calculations. Recently, among several different methods for the determination of the thermal diffusivity and thermal conductivity, transient techniques have become the preferable way for measuring thermal properties of materials. In this work, a very simple and low cost variation of the well known Angstrom method is employed in the experimental determination of the thermal diffusivity of some selected polymers. Cylindrical shaped samples 3 cm diameter and 7 cm high were prepared by cutting from long cylindrical commercial bars. The reproducibility is very good, and the results obtained were checked against results obtained by the hot wire technique, laser flash technique, and when possible, they were also compared with data found in the literature. Thermal conductivity may be then derived from the thermal diffusivity with the knowledge of the bulk density and the specific heat, easily obtained by differential scanning calorimetry. (C) 2009 Elsevier Ltd. All rights reserved.