839 resultados para Packed bed photocatalytic reactor


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertation for the Master degree in Biotechnology

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reactive Chromatography, Fixed-Bed Reactor, Heterogeneous, Hydrolysis, Ester, Catalyst, Adsorption, Ion-Exchange Resin

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A packed bed bioreactor (PBBR) was developed for rapid establishment of nitrification in brackish water hatchery systems in the tropics. The reactors were activated by immobilizing ammonia-oxidizing (AMONPCU- 1) and nitrite-oxidizing (NIONPCU-1) bacterial consortia on polystyrene and low-density polyethylene beads, respectively. Fluorescence in situ hybridization demonstrated the presence of autotrophic nitrifiers belong to Nitrosococcus mobilis, lineage of b ammonia oxidizers and nitrite oxidizer Nitrobacter sp. in the consortia. The activated reactors upon integration to the hatchery system resulted in significant ammonia removal (P\0.01) culminating to its undetectable levels. Consequently, a significantly higher percent survival of larvae was observed in the larval production systems. With spent water the reactors could establish nitrification with high percentage removal of ammonia (78%), nitrite (79%) and BOD (56%) within 7 days of initiation of the process. PBBR is configured in such a way to minimize the energy requirements for continuous operation by limiting the energy inputs to a single stage pumping of water and aeration to the aeration cells. The PBBR shall enable hatchery systems to operate under closed recirculating mode and pave the way for better water management in the aquaculture industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Air flow through packed beds was analyzed experimentally under conditions ranging from those that reinforce the effect of the wall on the void fraction to those that minimize it. The packing was spherical particles, with a tube-to-particle diameter ratio (D/dp) between 3 and 60. Air flow rates were maintained between 1.3 and 4.44 m3/min, and gas velocity was measured with a Pitot tube positioned above the bed exit. Measurements were made at various radial and angular coordinate values, allowing the distribution of air flow across the bed to be described in detail. Comparison of the experimentally observed radial profiles with those derived from published equations revealed that at high D/dp ratios the measured and calculated velocity profiles behaved similarly. At low ratios, oscillations in the velocity profiles agreed with those in the voidage profiles, signifying that treating the porous medium as a continuum medium is questionable in these cases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An X-ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two-dimensional (2-D) packed bed. A medical diagnostic X-ray unit has been used to image the local holdups in a 2-D cold model having a random packing of expanded polystyrene beads. An aqueous barium chloride solution was used as a fluid to achieve good contrast on X-ray images. To quantify the local liquid holdup, a simple calibration technique has been developed that can be used for most of the radiological methods such as gamma ray and neutron radiography. The global value of total liquid holdup, obtained by X-ray method, has been compared with two conventional methods: drainage and tracer response. The X-ray technique, after validation, has been used to visualize and quantify, the liquid hysteresis phenomena in a packed bed. The liquid flows in preferred paths or channels that carry droplets/rivulets of increasing size and number as the liquid flow rate is increased. When the flow is reduced, these paths are retained and the higher liquid holdup that persists in these regions leads to the holdup hysteresis effect. Holdup in some regions of the packed bed may be an order of magnitude higher than average at a particular flow rate. (c) 2005 American Institute of Chemical Engineers

Relevância:

100.00% 100.00%

Publicador:

Resumo:

When a gas is introduced at high velocity through a nozzle into a packed bed, it creates a raceway in the packed bed. It has been found that the raceway size is larger when it is formed by decreasing the gas velocity from its highest value than when it is formed by increasing the gas velocity. This phenomenon is known as raceway hysteresis. A hypothesis has been oroposed to explain the hysteresis phenomenon based on a force-balance approach which includes frictional, bed-weight, and pressure forces. According to this hypothesis, the frictional force acts in different directions when the raceway is expanding and contracting. In this article, the entire packed bed has been divided into radial and Cartesian co-ordinate systems, and the forces acting on the raceway have been solved analytically for a simplified one-dimensional case. Based on the force-balance approach, a general equation has been obtained to predict the diameter of the raceway for increasing And decreasing velocities. A reasonable agreement has been found between the theoretical predictions and experimental observations. The model has also been compared with published experimental and plant data. The hysteresis mechanism in the packed beds can be described reasonably by taking into consideration the direction of frictional forces for the increasing- and decreasin-velocity cases. The effects of the particleshape factor and void fraction on the raceway hysteresis are examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, it was developed a methodology for the determination of the dispersion of a gaseous tracer in porous media using the radiotracer technique. In order to evaluate several porous media, a cylindrical filter was constructed in PVC and connected to a system with constant flow. Inside this unit silica crystals (16-20) mesh was used as porous media and CH3Br (Methyl Bromide) marked with 82Br was used as radiotracer. An instantaneous pulse of tracer was applied in the system entrance and registered by two NaI (3x3)” scintillation detectors located one before and the other after the filter. The curves produced by the radioactive cloud and recorded by the detector were analyzed statistically using the weighted moment method. The mathematical model one considered as great dispersion of tracer was used to evaluate the flow conditions inside the filter system. The results show us that the weight moment method associated with radiotracer techniques is useful to evaluated an industrial filter and allows to measure the residence time distribution, τ, and the axial dispersion, DAB, gas in a porous medium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Temperature, pressure, gas stoichiometry, and residence time were varied to control the yield and product distribution of the palladium-catalyzed aminocarbonylation of aromatic bromides in both a silicon microreactor and a packed-bed tubular reactor. Automation of the system set points and product sampling enabled facile and repeatable reaction analysis with minimal operator supervision. It was observed that the reaction was divided into two temperature regimes. An automated system was used to screen steady-state conditions for offline analysis by gas chromatography to fit a reaction rate model. Additionally, a transient temperature ramp method utilizing online infrared analysis was used, leading to more rapid determination of the reaction activation energy of the lower temperature regimes. The entire reaction spanning both regimes was modeled in good agreement with the experimental data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le acque di vegetazione (AV) costituiscono un serio problema di carattere ambientale, sia a causa della loro elevata produzione sia per l’ elevato contenuto di COD che oscilla fra 50 e 150 g/l. Le AV sono considerate un refluo a tasso inquinante fra i più elevati nell’ambito dell’industria agroalimentare e la loro tossicità è determinata in massima parte dalla componente fenolica. Il presente lavoro si propone di studiare e ottimizzare un processo non solo di smaltimento di tale refluo ma anche di una sua valorizzazione, utlizzandolo come materia prima per la produzione di acidi grassi e quindi di PHA, polimeri biodegradabili utilizzabili in varie applicazioni. A tale scopo sono stati utilizzati due bioreattori anaerobici a biomassa adesa, di identica configurazione, con cui si sono condotti due esperimenti in continuo a diverse temperature e carichi organici al fine di studiare l’influenza di tali parametri sul processo. Il primo esperimento è stato condotto a 35°C e carico organico pari a 12,39 g/Ld, il secondo a 25°C e carico organico pari a 8,40 g/Ld. Si è scelto di allestire e mettere in opera un processo a cellule immobilizzate in quanto questa tecnologia si è rivelata vantaggiosa nel trattamento continuo di reflui ad alto contenuto di COD e carichi variabili. Inoltre si è scelto di lavorare in continuo poiché tale condizione, per debiti tempi di ritenzione idraulica, consente di minimizzare la metanogenesi, mediata da microrganismi con basse velocità specifiche di crescita. Per costituire il letto fisso dei due reattori si sono utilizzati due diversi tipi di supporto, in modo da poter studiare anche l’influenza di tale parametro, in particolare si è fatto uso di carbone attivo granulare (GAC) e filtri ceramici Vukopor S10 (VS). Confrontando i risultati si è visto che la massima quantità di VFA prodotta nell’ambito del presente studio si ha nel VS mantenuto a 25°C: in tale condizione si arriva infatti ad un valore di VFA prodotti pari a 524,668 mgCOD/L. Inoltre l’effluente in uscita risulta più concentrato in termini di VFA rispetto a quello in entrata: nell’alimentazione la percentuale di materiale organico presente sottoforma di acidi grassi volatili era del 54 % e tale percentuale, in uscita dai reattori, ha raggiunto il 59 %. Il VS25 rappresenta anche la condizione in cui il COD degradato si è trasformato in percentuale minore a metano (2,35 %) e questo a prova del fatto che l’acidogenesi ha prevalso sulla metanogenesi. Anche nella condizione più favorevole alla produzione di VFA però, si è riusciti ad ottenere una loro concentrazione in uscita (3,43 g/L) inferiore rispetto a quella di tentativo (8,5 g/L di VFA) per il processo di produzione di PHA, sviluppato da un gruppo di ricerca dell’università “La Sapienza” di Roma, relativa ad un medium sintetico. Si può constatare che la modesta produzione di VFA non è dovuta all’eccessiva degradazione del COD, essendo questa nel VS25 appena pari al 6,23%, ma piuttosto è dovuta a una scarsa concentrazione di VFA in uscita. Questo è di buon auspicio nell’ottica di ottimizzare il processo migliorandone le prestazioni, poiché è possibile aumentare tale concentrazione aumentando la conversione di COD in VFA che nel VS25 è pari a solo 5,87%. Per aumentare tale valore si può agire su vari parametri, quali la temperatura e il carico organico. Si è visto che il processo di acidogenesi è favorito, per il VS, per basse temperature e alti carichi organici. Per quanto riguarda il reattore impaccato con carbone attivo la produzione di VFA è molto ridotta per tutti i valori di temperatura e carichi organici utilizzati. Si può quindi pensare a un’applicazione diversa di tale tipo di reattore, ad esempio per la produzione di metano e quindi di energia.