927 resultados para PRECRACK TIP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The seven subunit Arp2/3 complex is a highly conserved nucleation factor of actin microfilaments. We have isolated the genomic sequence encoding a putative Arp3a protein of the moss Physcomitrella patens. The disruption of this ARP3A gene by allele replacement has generated loss-of-function mutants displaying a complex developmental phenotype. The loss-of function of ARP3A gene results in shortened, almost cubic chloronemal cells displaying affected tip growth and lacking differentiation to caulonemal cells. In moss arp3a mutants, buds differentiate directly from chloronemata to form stunted leafy shoots having differentiated leaves similar to wild type. Yet, rhizoids never differentiate from stem epidermal cells. To characterize the F-actin organization in the arp3a-mutated cells, we disrupted ARP3A gene in the previously described HGT1 strain expressing conditionally the GFP-talin marker. In vivo observation of the F-actin cytoskeleton during P. patens development demonstrated that loss-of-function of Arp3a is associated with the disappearance of specific F-actin cortical structures associated with the establishment of localized cellular growth domains. Finally, we show that constitutive expression of the P. patens Arp3a and its Arabidopsis thaliana orthologs efficiently complement the mutated phenotype indicating a high degree of evolutionary conservation of the Arp3 function in land plants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of the tip clearance and vaneless diffuser width on the stage performance and flow fields of a centrifugal compressor were studied numerically and results were compared to the experimental measurements. The diffuser width was changed by moving the shroud side of the diffuser axially and six tip clearances size from 0.5 to 3 mm were studied. Moreover, the effects of rotor-stator interaction on the diffuser and impeller flow fields and performance were studied. Also transient simulations were carried out in order to investigate the influence of the interaction on the impeller and diffuser performance parameters. It was seen that pinch could improve the performance and it help to get more uniform flow at exit and less back flow from diffuser to the impeller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Highly efficient mechanisms regulate intracellular calcium (Ca2+) levels. The recent discovery of new components linking intracellular Ca2+ stores to plasma membrane Ca2+ entry channels has brought new insight into the understanding of Ca2+ homeostasis. Stromal interaction molecule 1 (STIM1) was identified as a Ca2+ sensor essential for Ca2+ store depletion-triggered Ca2+ influx. Orai1 was recognized as being an essential component for the Ca2+ release-activated Ca2+ (CRAC) channel. Together, these proteins participate in store-operated Ca2+ channel function. Defective regulation of intracellular Ca2+ is a hallmark of several diseases. In this review, we focus on Ca2+ regulation by the STIM1/Orai1 pathway and review evidence that implicates STIM1/Orai1 in several pathological conditions including cardiovascular and pulmonary diseases, among others.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hammaslääketieteessä käytetettävien komposiittien valonläpäisevyys vaihtelee. Samoin LED-valokovettimet eroavat toisistaan valotehonsa ja muotoilunsa perusteella. On yleisesti tiedossa, että valokovettimesta tulevan valon intensiteetti pinta-alayksikköä kohden heikkenee, kun kovettimen etäisyys kasvaa. Toisaalta ei ole tiedossa, miten valokovetettavan kohteen ja valokovettimen kärjen väliin sijoitettu materiaali tarkalleenottaen vaikuttaa valon intensiteettiin eri etäisyyksiä käytettäessä. Tämän tutkimuksen tarkoituksena on selvittää, miten valokovetettavan kohteen ja valokovettimen kärjen väliin asetettava etukäteen polymerisoitu materiaali vaikuttaa valon intensiteettiin eri etäisyyksillä. Tutkimus suoritettiin käyttämällä kahta eri valokovetinta. Jotta etäisyyden vaikutusta valotustehoon voitiin demonstroida, vaihdettiin kovettimen etäisyyttä sensorista 0,2,4,6,8,10mm välillä. Valotehot rekisteröitiin MARC resin calibrator -laitteella. Sensorin ja valokovettimen kärjen väliin asetettavat erilaiset komposiittilevyt olivat valmiiksi kovetettuja,1mm paksuisia, filleripitoisuuksiltaan neljää erilaista muovia. Valotehot rekisteröitiin jokaiselta etäisyydeltä komposiitin ollessa sensorin päällä. Rinnakkaisesti verrattiin myös etäisyyden vaikutusta valotehoon ilman esikovetettua materiaalia kovettimen kärjen ja valoa mittaavan sensorin välissä. Vertailun suorittamiseksi laskettiin intensiteettisuhdeluku muovillisen ja muovittoman arvon välillä aina tietyllä etäisyydellä Valokovettimen kärjen etäisyyden kasvattaminen sensorista (eli valokovetettavasta kohteesta) odotusten mukaisesti pienensi valotehoa. Laittamalla sensorin ja kovettimen väliin komposiittilevy, valoteho pieneni odotetusti vielä enemmän. Tutkittaessa intensiteettisuhdetta (valoteho muovin kanssa : valoteho ilman muovia) kuitenkin huomattiin, että 4-6mm:n kohdalla suhdeluku oli suurempi kuin 0,2,8 ja 10mm kohdalla. Johtopäätöksenä oli, että suurin mahdollinen valokovetusteho saavutetan laittamalla kovetuskärki mahdollisimman lähelle kohdetta. Jos valokovetettavan kohteen ja valokovettimen kärjen välissä oli kiinteä komposiittipalanen, suurin mahdollinen valokovetusteho kohteeseen saavutetaan edelleen laittamalla kovetuskärki kiinni muoviin. Jos etäisyyttä muovin pinnasta sen sijaan kasvatettiin, valokovetusteho ei laskenutkaan niin nopeasti kuin oli odotettu. Tämä voi liittyä siihen, että tehokkaan valokeilan halkaisijan koko on suurempi verrattuna komposiitin sekä sensorin halkaisian kokoon. Toiseksi on arvioitu, että resiinikomposiitin täyteaineet voisivat fokusoida läpi kulkevaa valoa sensoriin. Se, pitääkö tämä ilmiö paikkansa, vaatii kuitenkin enemmän tutkimusta

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este art??culo se analizan dos experiencias formativas ocurridas en el primer tercio del siglo XX, concretamente las escuelas de aprendices tip??graficos y de aprendices metal??rgicos. La finalidad de la primera era proporcionar instrucci??n t??cnica elemental a los j??venes que se dedicaran al arte de la imprenta en la secci??n de cajas. La segunda ten??a como objetivo ser el lugar donde completar la educaci??n pr??ctica que los aprendices recib??an en sus centros de trabajo, mediante ciertos conocimientos te??ricos, a fin de perfeccionar su capacidad profesional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumen tomado de la publicación

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the degree of conversion and hardness of a dental composite resin Filtek (TM) Z-350 (3M ESPE, Dental Products St. Paul, MN) photo-activated for 20 s of irradiation time with two different light guide tips, metal and polymer, coupled on blue LED Ultraled LCU (Dabi Atlante, SP, Brazil). With the metal light tip, power density was of 352 and with the polymer was of 456 mW/cm(2), respectively. Five samples (4 mm in diameter and 2mm in thickness-ISO 4049), were made for each Group evaluated. The measurements for DC (%) were made in a Nexus-470 FT-IR, Thermo Nicolet, E.U.A. Spectroscopy (FTIR). Spectra for both uncured and cured samples were analyzed using an accessory of reflectance diffuse. The measurements were recorded in absorbance operating under the following conditions: 32 scans, 4 cm(-1) resolution, 300-4000 cm(-1) wavelength. The percentage of unreacted carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm(-1)) against internal standard before and after curing of the sample: aromatic C-C (peak at 1610 cm(-1)). The Vickers hardness measurements (top and bottom surfaces) were performed in a universal testing machine (Buehler MMT-3 digital microhardness tester Lake Bluff, Illinois USA). A 50 gf load was used and the indenter with a dwell time of 30 s. The data were submitted to the test t Student at significance level of 5%. The mean values of degree of conversion for the polymer and metal light guide tip no were statistically different (p = 0.8389). The hardness mean values were no statistically significant different among the light guide tips (p = 0.6244), however, there was difference between top and bottom surfaces (p < 0.001). The results show that so much the polymer light tip as the metal light tip can be used for the photo-activation, probably for the low quality of the light guide tip metal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diversity of the V3 loop tip motif sequences of HIV-1 subtype B was analyzed in patients from Botucatu (Brazil) and Montpellier (France). Overall, 37 tetrameric tip motifs were identified, 28 and 17 of them being recognized in Brazilian and French patients, respectively. The GPGR (P) motif was predominant in French but not in Brazilian patients (53.5% vs 31.0%), whereas the GWGR (W) motif was frequent in Brazilian patients (23.0%) and absent in French patients. Three tip motif groups were considered: P, W, and non-P non-W groups. The distribution of HIV-1 isolates into the three groups was significantly different between isolates from Botucatu and from Montpellier (P < 0.001). A higher proportion of CXCR4-using HIV-1 (X4 variants) was observed in the non-P non-W group as compared with the P group (37.5% vs 19.1%), and no X4 variant was identified in the W group (P < 0.001). The higher proportion of X4 variants in the non-P non-W group was essentially observed among the patients from Montpellier, who have been infected with HIV-1 for a longer period of time than those from Botucatu. Among patients from Montpellier, CD4+ cell counts were lower in patients belonging to the non-P non-W group than in those belonging to the P group (24 cells/µL vs 197 cells/µL; P = 0.005). Taken together, the results suggest that variability of the V3 loop tip motif may be related to HIV-1 coreceptor usage and to disease progression. However, as analyzed by a bioinformatic method, the substitution of the V3 loop tip motif of the subtype B consensus sequence with the different tip motifs identified in the present study was not sufficient to induce a change in HIV-1 coreceptor usage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: A giant fusiform aneurysm in the posterior cerebral artery (PCA) is rare, as is fenestration of the PCA and basilar apex variation. We describe the angiographic and surgical findings of a giant fusiform aneurysm in the P1-P2 PCA segment associated with PCA bilateral fenestration and superior cerebellar artery double origin.CLINICAL PRESENTATION: A 26-year-old woman presented with a 2-month history of visual blurring. Digital subtraction angiography showed a giant (2.5 cm) fusiform PCA aneurysm in the right P1-P2 segment. The 3-dimensional view showed a caudal fusion pattern from the upper portion of the basilar artery associated with a bilateral long fenestration of the P1 and P2 segments and superior cerebellar artery double origin.INTERVENTION: Surgical trapping of the right P1 -P2 segment, including the posterior communicating artery, was performed by a pretemporal approach. Angiograms performed 3 and 13 months after surgery showed complete aneurysm exclusion, and the PCA was permeated and filled the PCA territory. Clinical follow-up at 14 months showed the patient with no deficits and a return to normal life.CONCLUSION: To our knowledge, this is the first report of a giant fusiform aneurysm of the PCA associated with P1-P2 segment fenestration and other variations of the basilar apex (bilateral superior cerebellar artery duplication and caudal fusion). Comprehension of the embryology and anatomy of the PCA and its related vessels and branches is fundamental to the decision-making process for a PCA aneurysm, especially when parent vessel occlusion is planned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo prospectivo avaliou os métodos semiquantitativo e qualitativo de cultura de cateter para o diagnóstico de infecção relacionada a cateter (IRC) em recém-nascidos (RN). Foram incluídas pontas de cateteres provenientes de recém-nascidos internados na Unidade Neonatal do Hospital das Clínicas da Faculdade de Medicina de Botucatu, UNESP. Foram utilizadas as técnicas semiquantitativa e qualitativa de cultura de cateter. Para o diagnóstico de IRC, os microrganismos isolados das culturas de cateteres e de hemoculturas periféricas foram identificados e submetidos ao teste de sensibilidade a antimicrobianos. O padrão ouro correspondeu ao diagnóstico de certeza de IRC, com o isolamento do mesmo microrganismo (espécie e perfil de sensibilidade a antimicrobianos) isolado em hemocultura periférica. Foram estudados 85 cateteres provenientes de 63 RN. A cultura semiquantitativa, embora tenha apresentado menor sensibilidade (90%), apresentou uma maior especificidade (71%) em comparação à sensibilidade de 100% e especificidade de 60% encontradas na cultura qualitativa. Através da identificação dos microrganismos obtidos nas culturas de cateteres, observou-se uma predominância de espécies de Estafilococos coagulase-negativa (ECN). A espécie Staphylococcus epidermidis foi a prevalente (77,5%) nos cateteres com culturas semiquantitativas positivas. Dos 11 episódios de IRC diagnosticados, 8 (72,7%) foram associados a espécies de ECN, dos quais 6 eram da espécie S. epidermidis. Também foram detectados dois casos de IRC por S. aureus e um caso por Candida parapsilosis. O método de cultura semiquantitativo cateter apresentou vantagens para o diagnóstico de IRC em RN quando comparado com o método qualitativo tradicional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the number of colony-forming units (CFU) that best correlates with catheter-related infections (CRI) in newborns.Methods: This was a prospective study of semiquantitative cultures of catheter tips obtained from newborns in the neonatal unit at Faculdade de Medicina de Botucatu, state of São Paulo, Brazil. The microorganisms isolated from catheter and peripheral blood cultures were identified and submitted to a drug susceptibility test. The optimal cutoff point was determined by the receiver operating characteristic (ROC) curve.Results: A total of 85 catheters obtained from 63 newborns were studied. Staphylococcus epidermidis was the predominant species in the catheters (75%). Eight of 11 (72.7%) CRI episodes were associated with coagulase-negative staphylococci, six of which were of the S. epidermidis type. ROC curve analysis indicated that the optimal cutoff point for the diagnosis of CRI was 122 CFU.Conclusions: The cutoff point of 122 CFU correlated best with the diagnosis of CRI in newborns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new strategy for the label-free electrochemical detection of DNA hybridization for detecting hepatitis C virus based on electrostatic modulation of the ion-exchange kinetics of a polypyrrole film deposited at microelectrodes. Synthetic single-stranded 18-mer HCV genotype-1-specific probe DNA has been immobilized at a 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole film established by electropolymerization at the previously formed polypyrrole layer. HCV DNA sequences (244-mer) resulting from the reverse transcriptase-linked polymerase chain reaction amplification of the original viral RNA were monitored by affecting the ion-exchange properties of the polypyrrole film. The performance of this miniaturized DNA sensor system was studied in respect to selectivity, sensitivity, and reproducibility. The limit of detection was determined at 1.82 x 10(-21) mol L-1. Control experiments were performed with cDNA from HCV genotypes 2a/c, 2b, and 3 and did not show any unspecific binding. Additionally, the influence of the spacer length of 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole on the behavior of the DNA sensor was investigated. This biosensing scheme was finally extended to the electrochemical detection of DNA at submicrometer-sized DNA biosensors integrated into bifunctional atomic force scanning electrochemical microscopy probes. The 18-mer DNA target was again monitored by following the ion-exchange properties of the polypyrrole film. Control experiments were performed with 12-base pair mismatched sequences.