993 resultados para PACEMAKER IMPLANTATION
Resumo:
Background: The incidence of venous lesions following transvenous cardiac device implantation is high. Previous implantation of temporary leads ipsilateral to the permanent devices, and a depressed left ventricular ejection fraction have been associated with an increased risk of venous lesions, though the effects of preventive strategies remain controversial. This randomized trial examined the effects of warfarin in the prevention of these complications in high-risk patients. Method: Between February 2004 and September 2007, we studied 101 adults who underwent a first cardiac device implantation, and who had a left ventricular ejection fraction <= 0.40, or a temporary pacing system ipsilateral to the permanent implant, or both. After device implantation, the patients were randomly assigned to warfarin to a target international normalized ratio of 2.0-3.5, or to placebo. Clinical and laboratory evaluations were performed regularly up to 6 months postimplant. Venous lesions were detected at 6 months by digital subtraction venography. Results: Venous obstructions of various degrees were observed in 46 of the 92 patients (50.0%) who underwent venography. The frequency of venous obstructions was 60.4% in the placebo, versus 38.6% in the warfarin group (P = 0.018), corresponding to an absolute risk reduction of 22% (relative risk = 0.63; 95% confidence interval = 0.013-0.42). Conclusions: Warfarin prophylaxis lowered the frequency of venous lesions after transvenous devices implantation in high-risk patients. (PACE 2009; 32:S247-S251)
Resumo:
First-degree atrio-ventricular (AV) block is defined as a PR interval longer than 200 ms. If too long, it can become clinically relevant and may mimic a pacemaker syndrome. We report the case of a young woman with a long PR interval, probably congenital, with episodes of syncope and dizziness since childhood. Pseudo-pacemaker syndrome is rare and is a Class IIa recommendation for a pacemaker implantation. A dual-chamber pacemaker was implanted and short AV delay was programmed, with rapid clinical improvement.
Resumo:
BACKGROUND: The efficacy of cardiac pacing for prevention of syncopal recurrences in patients with neurally mediated syncope is controversial. We wanted to determine whether pacing therapy reduces syncopal recurrences in patients with severe asystolic neurally mediated syncope. METHODS AND RESULTS: Double-blind, randomized placebo-controlled study conducted in 29 centers in the Third International Study on Syncope of Uncertain Etiology (ISSUE-3) trial. Patients were ≥40 years, had experienced ≥3 syncopal episodes in the previous 2 years. Initially, 511 patients, received an implantable loop recorder; 89 of these had documentation of syncope with ≥3 s asystole or ≥6 s asystole without syncope within 12 ± 10 months and met criteria for pacemaker implantation; 77 of 89 patients were randomly assigned to dual-chamber pacing with rate drop response or to sensing only. The data were analyzed on intention-to-treat principle. There was syncope recurrence during follow-up in 27 patients, 19 of whom had been assigned to pacemaker OFF and 8 to pacemaker ON. The 2-year estimated syncope recurrence rate was 57% (95% CI, 40-74) with pacemaker OFF and 25% (95% CI, 13-45) with pacemaker ON (log rank: P=0.039 at the threshold of statistical significance of 0.04). The risk of recurrence was reduced by 57% (95% CI, 4-81). Five patients had procedural complications: lead dislodgment in 4 requiring correction and subclavian vein thrombosis in 1 patient. CONCLUSIONS: Dual-chamber permanent pacing is effective in reducing recurrence of syncope in patients ≥40 years with severe asystolic neurally mediated syncope. The observed 32% absolute and 57% relative reduction in syncope recurrence support this invasive treatment for the relatively benign neurally mediated syncope. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00359203.
Resumo:
AIMS: To evaluate short-term clinical outcomes following transcatheter aortic valve implantation (TAVI) using CE-mark approved devices in Switzerland. METHODS AND RESULTS: The Swiss TAVI registry is a national, prospective, multicentre, monitored cohort study evaluating clinical outcomes in consecutive patients undergoing TAVI at cardiovascular centres in Switzerland. From February 2011 to March 2013, a total of 697 patients underwent TAVI for native aortic valve stenosis (98.1%), degenerative aortic bioprosthesis (1.6%) or severe aortic regurgitation (0.3%). Patients were elderly (82.4±6 years), 52% were females, and the majority highly symptomatic (73.1% NYHA III/IV). Patients with severe aortic stenosis (mean gradient 44.8±17 mmHg, aortic valve area 0.7±0.3 cm²) were either deemed inoperable or at high risk for conventional surgery (STS 8.2%±7). The transfemoral access was the most frequently used (79.1%), followed by transapical (18.1%), direct aortic (1.7%) and subclavian access (1.1%). At 30 days, rates of all-cause mortality, cerebrovascular events and myocardial infarction were 4.8%, 3.3% and 0.4%, respectively. The most frequently observed adverse events were access-related complications (11.8%), permanent pacemaker implantation (20.5%) and bleeding complications (16.6%). The Swiss TAVI registry is registered at ClinicalTrials.gov (NCT01368250). CONCLUSIONS: The Swiss TAVI registry is a national cohort study evaluating consecutive TAVI procedures in Switzerland. This first outcome report provides favourable short-term clinical outcomes in unselected TAVI patients.
Resumo:
Aims: To evaluate short-term clinical outcomes following transcatheter aortic valve implantation (TAVI) using CE-mark approved devices in Switzerland. Methods and results: The Swiss TAVI registry is a national, prospective, multicentre, monitored cohort study evaluating clinical outcomes in consecutive patients undergoing TAVI at cardiovascular centres in Switzerland. From February 2011 to March 2013, a total of 697 patients underwent TAVI for native aortic valve stenosis (98.1%), degenerative aortic bioprosthesis (1.6%) or severe aortic regurgitation (0.3%). Patients were elderly (82.4±6 years), 52% were females, and the majority highly symptomatic (73.1% NYHA III/IV). Patients with severe aortic stenosis (mean gradient 44.8±17 mmHg, aortic valve area 0.7±0.3 cm2) were either deemed inoperable or at high risk for conventional surgery (STS 8.2%±7). The transfemoral access was the most frequently used (79.1%), followed by transapical (18.1%), direct aortic (1.7%) and subclavian access (1.1%). At 30 days, rates of all-cause mortality, cerebrovascular events and myocardial infarction were 4.8%, 3.3% and 0.4%, respectively. The most frequently observed adverse events were access-related complications (11.8%), permanent pacemaker implantation (20.5%) and bleeding complications (16.6%). The Swiss TAVI registry is registered at ClinicalTrials.gov (NCT01368250). Conclusions: The Swiss TAVI registry is a national cohort study evaluating consecutive TAVI procedures in Switzerland. This first outcome report provides favourable short-term clinical outcomes in unselected TAVI patients.
Resumo:
Aims Neurally meditated reflex or neurocardiogenic or vasovagal syncope (NMS) is usually mediated by a massive vagal reflex. This study reports the long-term outcome of NMS therapy based on endocardial radiofrequency (RF) catheter ablation of the cardiac vagal nervous system aiming permanent attenuation or elimination of the cardioinhibitory reflex (cardioneuroablation). Methods and results A total of 43 patients (18F/25M, 32.9+/-15 years) without apparent cardiopathy (left ventricular ejection fraction=68.6+/-5%) were included. All had recurrent NMS (4.7+/-2 syncope/patient) with important cardioinhibition (pauses=13.5+/-13 s) at head-up tilt test (HUT), normal electrocardiogram (ECG), and normal atropine test (AT). The patients underwent atrial endocardial RF ablation using spectral mapping to track the neurocardiac interface (AF Nest Mapping). The follow-up (FU) consisted of clinical evaluation, ECG (1 month/every 6 months/or symptoms), Holter (every 6 months/or symptoms), HUT (>= 4 months/or symptoms), and AT (end of ablation and >= 6 months). A total of 44 ablations (48+/-9 points/patient) were performed. Merely three cases of spontaneous syncope occurred in 45.1+/-22 months (two vasodepressor, one undefined). Only four partial cardioinhibitory responses occurred in post-ablation HUT without pauses or asystole (sinus bradycardia). Long-term AT (21.7+/-11 months post) was negative in 33 (76.7%, P<0.01), partially positive in 7(16.3%), and normal in three patients only (6.9%) reflecting long-term vagal denervation (AT-Delta% HR pre 79.4% x 23.2% post). The post-ablation stress test and Holter showed no abnormalities. No major complications occurred. Conclusion Endocardial RF catheter ablation of severe neurally meditated reflex syncope prevented pacemaker implantation and showed excellent long-term results in well selected patients. Despite no action in vasodepression it seems to cause enough long-term vagal reflex attenuation, eliminating the cardioinhibition, and keeping most patients asymptomatic. Indication was based on clinical symptoms, reproduction of severe cardioinhibitory syncope, and normal atropine response.
Resumo:
OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary), connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI), high septal ("AAI") and bifocal ("DDT" with AV interval ~ 0) stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p <= 0.01). The conventional method of stimulation showed the worst result. CONCLUSION: These results suggest that, when left ventricular stimulation is not possible, right ventricular bifocal stimulation should be used in patients with severe cardiomyopathy where a pacemaker is indicated.
Resumo:
PURPOSE: To analyze the influence of biventricular pacing (BP) on clinical behavior, ventricular arrhythmia (VA) prevalence, and left ventricular ejection fraction (LV EF) by gated ventriculography. METHODS: Twenty-four patients with left bundle branch block (LBBB) and NYHA class III and IV underwent pacemaker implantation and were randomized either to the conventional or BP group, all receiving BP after 6 months. RESULTS: Sixteen patients were in NYHA class IV (66.6%) and 8 were in class III (33.4%). After 1-year follow-up, 14 patients were in class II (70%) and 5 were in class III (25%). Two sudden cardiac deaths occurred. A significant reduction in QRS length was found with BP (p=0.006). A significant statistical increase, from a mean of 19.13 ± 5.19% (at baseline) to 25.33 ± 5.90% (with BP) was observed in LVEF Premature ventricular contraction prevalence decreased from a mean of 10,670.00 ± 12,595.39 SD or to a mean of 3,007.00 ± 3,216.63 SD PVC/24 h with BP (p<0.05). Regarding the hospital admission rate over 1 year, we observed a significant reduction from 60. To 16 admissions with BP (p<0.05). CONCLUSION: Patients with LBBB and severe heart failure experienced, with BP, a significant NYHA class and LVEF improvement. A reduction in the hospital admission rate and VA prevalence also occurred.
Resumo:
AbstractIn children with structural congenital heart disease (CHD), the effects of chronic ventricular pacing on diastolic function are not well known. On the other hand, the beneficial effect of septal pacing over apical pacing is still controversial.The aim of this study was to evaluate the influence of different right ventricular (RV) pacing site on left ventricular (LV) diastolic function in children with cardiac defects.Twenty-nine pediatric patients with complete atrioventricular block (CAVB) and CHD undergoing permanent pacing were prospectively studied. Pacing sites were RV apex (n = 16) and RV septum (n = 13). Echocardiographic assessment was performed before pacemaker implantation and after it, during a mean follow‑up of 4.9 years.Compared to RV septum, transmitral E-wave was significantly affected in RV apical pacing (95.38 ± 9.19 vs 83 ± 18.75, p = 0.038). Likewise, parameters at the lateral annular tissue Doppler imaging (TDI) were significantly affected in children paced at the RV apex. The E´ wave correlated inversely with TDI lateral myocardial performance index (Tei index) (R2= 0.9849, p ≤ 0.001). RV apex pacing (Odds ratio, 0.648; confidence interval, 0.067-0.652; p = 0.003) and TDI lateral Tei index (Odds ratio, 31.21; confidence interval, 54.6-177.4; p = 0.025) predicted significantly decreased LV diastolic function.Of the two sites studied, RV septum prevents pacing-induced reduction of LV diastolic function.
Resumo:
BACKGROUND: Pulse wave velocity (PWV), an index of arterial wall stiffness, is modulated by blood pressure (BP). Whether heart rate (HR) is also a modulator of PWV is controversial. Recent research involving mainly patients with high aortic PWV have found either no change or a positive correlation between the two. Given that PWV is increasingly being measured in cardiovascular studies, the relationship between HR and PWV should be known in patients with preserved arterial wall elasticity. OBJECTIVE: The aim of this study was to evaluate the importance of HR as a determinant of the variability in PWV in patients with a low degree of atherosclerosis. DESIGN AND METHODS: Fourteen patients (five female, nine male; aged 68 +/- 8 years) were evaluated post pacemaker implantation due to sick sinus or carotid hypersensitivity syndromes. Carotid-femoral PWV was measured at rest and during atrial pacing at 80, 90 and 100 bpm (paced HR). Arterial femoral blood flow (AFBF) was measured by echodoppler. RESULTS: PWV increased from 6.2 +/- 1.5 m/s (mean +/- SD) during resting sinus rhythm (HR 62 +/- 8 bpm; mean +/- SD) to 6.8 +/- 1.0, 7.0 +/- 0.9, and 7.6 +/- 1.1 m/s at pacing rates of 80, 90 and 100 bpm, respectively (P < 0.0001). Systolic (SBP) and mean blood pressure (MBP) remained constant at all HR levels, whereas AFBF increased in a linear fashion. CONCLUSIONS: These results demonstrate that even in patients with a low degree of atherosclerosis, HR is a potential modulator of carotid-femoral PWV.
Resumo:
Cardiac arrhythmias are very frequent in fetuses and newborns. The prognosis depends on the nature of the arrhythmias but is most often either spontaneously benign or following short-term medication administration. A correct diagnosis is essential for both management and prognosis. It is based on echocardiography during the fetal period and mainly on history, physical exam, and electrocardiogram after birth, but other modalities are available to record transient arrhythmic events. Irregular rhythms are mostly benign and rarely require therapy. In most fetuses and infants, tachyarrhythmias resolve spontaneously or require short-term administration of antiarrhythmics. Approximately one third of these may recur later on, especially during adolescence. Persistent bradyarrhythmias might require pacemaker implantation when associated with failure to thrive or with risk of sudden death. CONCLUSION: Arrhythmias in fetuses and infants are very common and mostly benign. History, physical exam, and recording of the arrhythmia are essential to make a correct diagnosis and establish an appropriate management for the rare potentially harmful arrhythmias.
Resumo:
OBJECTIVE: We aim to explore how health surrogates of patients with dementia proceed in decision making, which considerations are decisive, and whether family surrogates and professional guardians decide differently. METHODS: We conducted an experimental vignette study using think aloud protocol analysis. Thirty-two family surrogates and professional guardians were asked to decide on two hypothetical case vignettes, concerning a feeding tube placement and a cardiac pacemaker implantation in patients with end-stage dementia. They had to verbalize their thoughts while deciding. Verbalizations were audio-recorded, transcribed, and analyzed according to content analysis. By experimentally changing variables in the vignettes, the impact of these variables on the outcome of decision making was calculated. RESULTS: Although only 25% and 31% of the relatives gave their consent to the feeding tube and pacemaker placement, respectively, 56% and 81% of the professional guardians consented to these life-sustaining measures. Relatives decided intuitively, referred to their own preferences, and focused on the patient's age, state of wellbeing, and suffering. Professional guardians showed a deliberative approach, relied on medical and legal authorities, and emphasized patient autonomy. Situational variables such as the patient's current behavior and the views of health care professionals and family members had higher impacts on decisions than the patient's prior statements or life attitudes. CONCLUSIONS: Both the process and outcome of surrogate decision making depend heavily on whether the surrogate is a relative or not. These findings have implications for the physician-surrogate relationship and legal frameworks regarding surrogacy. Copyright © 2011 John Wiley & Sons, Ltd.
Resumo:
NlmCategory="UNASSIGNED">Rapid deployment aortic valve replacement (RDAVR) with the use of rapid deployment valve systems represents a smart alternative to the use of standard aortic bioprosthesis for aortic valve replacement. Nevertheless, its use is still debatable in patients with pure aortic valve regurgitation or true bicuspid aortic valve because of the risk of postoperative paravalvular leak. To address this issue, an optimal annulus-valve size match seems to be the ideal surgical strategy. This article describes a new technique developed to stabilize the aortic annulus and prevent paravalvular leak after RDAVR. To confirm the feasibility, this technique was performed in six patients with severe symptomatic aortic stenosis who were scheduled to undergo aortic valve replacement at our center. All patients survived surgery and were discharged from the hospital. There were no new intracardiac conduction system disturbances observed, and a permanent pacemaker implantation was not required in any of the patients. The intraoperative and postoperative echocardiogram confirmed successful positioning of the valve, and no paravalvular leak was observed. In this preliminary experience, RDAVR through a full sternotomy or an upper hemisternotomy approach with the use of aortic annulus stabilization technique was safe, and no leak was observed. Future studies on large series of patients are necessary to confirm the safety and effectiveness of this technique in preventing paravalvular leak in patients with true bicuspid aortic valves or pure aortic regurgitation.
Resumo:
Introducción: El sincope vasovagal es la principal causa de pérdida transitoria de la consciencia. Las guías internacionales de tratamiento del síncope recomiendan con un nivel de evidencia débil, el implante de marcapasos para pacientes refractarios al tratamiento médico que tienen respuesta cardioinhibitoria. Hasta el momento no existe una revisión sistemática que resuma la mejor evidencia disponible a la fecha sobre la estimulación con marcapasos en síncope vasovagal para disminuir recurrencias. Métodos: Revisión sistemática de la literatura de ensayos clínicos aleatorizados acerca del uso del marcapasos en síncope vasovagal para disminuir recurrencias. Resultados: La búsqueda inicial arrojó un total de 299 resultados, de los cuales solo 8 cumplieron los criterios de selección. Se evaluó la recurrencia de síncopes en el grupo de estimulación con marcapasos comparada con el grupo sin estimulación. Con diferencias metodológicas marcadas en los estudios seleccionados en general no hay una evidencia sólida para asegurar que el marcapasos disminuye recurrencias de síncope vasovagal. Discusión: El marcapasos en síncope vasovagal no tiene efecto benéfico en disminución de recurrencias cuando se implanta a toda la población refractaria al tratamiento médico para disminuir recurrencias. Solamente un grupo con características clínicas muy seleccionadas podría beneficiarse de la estimulación con marcapasos para disminuir recurrencias de síncope. Conclusión: La evidencia disponible sugiere que el marcapasos no tiene efecto en disminución de recurrencias en todo el grupo de pacientes con síncope vasovagal refractarios a tratamiento médico.
Resumo:
Objetivo: Avaliar aspectos da qualidade de vida em pacientes pós-implante de marca-passo e relacionar com gênero, idade e tempo de implante. Métodos: Foram estudados 107 indivíduos de ambos os gêneros (49,5% do sexo feminino e 50,5% do sexo masculino), tempo de implante três a 12 meses (média de 6,36±2,99 meses), estáveis clinicamente com idade acima de 18 anos (média de 69,3±12,6 anos). A avaliação constou de: dados pessoais, clínicos, do implante e questionários de qualidade de vida (AQUAREL e SF-36). Análise estatística empregou teste t e correlação de Pearson, com significância de 5%. Resultados: No SF-36, o menor escore ocorreu no domínio aspectos físicos e o maior, em aspectos sociais. No AQUAREL, o menor escore foi em dispneia e o maior em desconforto. Verificou-se associação significante entre gênero e qualidade de vida no SF-36 (capacidade funcional e aspectos emocionais) e no AQUAREL (dispneia). Observaram-se correlações negativas entre idade e qualidade de vida (capacidade funcional do SF-36 e em desconforto do AQUAREL) em relação ao tempo de implante, correlação com vitalidade do SF-36. Conclusão: Menores escores de qualidade de vida foram encontrados em aspectos físicos e dispneia; maiores em aspectos sociais e desconforto. Homens apresentaram maiores escores de qualidade de vida em capacidade funcional, aspectos emocionais e dispneia. Conforme aumenta a idade, pior é a qualidade de vida em capacidade funcional e desconforto, e, quanto maior o tempo de implante de marca-passo, pior a qualidade de vida em vitalidade. Gênero, idade e tempo de implante influenciam na qualidade de vida, dessa forma, essas variáveis devem ser consideradas nas estratégias para melhora da qualidade de vida em portadores de marca-passo.