940 resultados para ON-A-CHIP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A microfluidic glass chip system incorporating a quartz crystal microbalance (QCM) to measure the square root of the viscosity-density product of room temperature ionic liquids (RTILs) is presented. The QCM covers a central recess on a glass chip, with a seal formed by tightly clamping from above outside the sensing region. The change in resonant frequency of the QCM allows for the determination of the square root viscosity-density product of RTILs to a limit of similar to 10 kg m(-2) s(-0.5). This method has reduced the sample size needed for characterization from 1.5 ml to only 30 mu l and allows the measurement to be made in an enclosed system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new domain-specific, reconfigurable system-on-a-chip (SoC) architecture is proposed for video motion estimation. This has been designed to cover most of the common block-based video coding standards, including MPEG-2, MPEG-4, H.264, WMV-9 and AVS. The architecture exhibits simple control, high throughput and relatively low hardware cost when compared with existing circuits. It can also easily handle flexible search ranges without any increase in silicon area and can be configured prior to the start of the motion estimation process for a specific standard. The computational rates achieved make the circuit suitable for high-end video processing applications, such as HDTV. Silicon design studies indicate that circuits based on this approach incur only a relatively small penalty in terms of power dissipation and silicon area when compared with implementations for specific standards. Indeed, the cost/performance achieved exceeds that of existing but specific solutions and greatly exceeds that of general purpose field programmable gate array (FPGA) designs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The design of a System-on-a-Chip (SoC) demonstrator for a baseline JPEG encoder core is presented. This combines a highly optimized Discrete Cosine Transform (DCT) and quantization unit with an entropy coder which has been realized using off-the-shelf synthesizable IP cores (Run-length coder, Huffman coder and data packer). When synthesized in a 0.35 µm CMOS process, the core can operate at speeds up to 100 MHz and contains 50 k gates plus 11.5 kbits of RAM. This is approximately 20% less than similar JPEG encoder designs reported in literature. When targeted at FPGA the core can operate up to 30 MHz and is capable of compressing 9-bit full-frame color input data at NTSC or PAL rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study, we describe a simple and efficient method for on-chip storage of reagents for point-of-care (POC) diagnostics. The method is based on gelification of all reagents required for on-chip PCR-based diagnostics as a ready-to-use product. The result reported here is a key step towards the development of a ready and easy to use fully integrated Lab-on-a-chip (LOC) system for fast, cost-effective and efficient POC diagnostics analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents the design and simulation of a novel passive micromixer. The micromixer consists of two inlet tanks, one mixing channel and two outlet channels. In order to maximise the mixing efficiency, the following considerations are made: (i) The inlet tanks are followed by a series of microchannels, in which the flow is split. The microchannels are arranged in an interdigital manner to maximise the contact area between the two flows. (ii) The microchannels attached to the lower inlet tank have an upward slope while those attached to the upper tank have a downward slope. The higher-density flow is fed to the lower inlet tank and gets an upward velocity before entering the mixing channel. (iii) Two triangular barriers are placed within the mixing channel to impose chaotic advection and perturb the less-mixed flow along the top and bottom surfaces of the channel. (iv) Finally, two outlet channels are incorporated to discard the less-mixed flow. Three-dimensional simulations are carried out to evaluate the performance of the micromixer. Simulations are performed in the absence and presence of the gravitational force to analyse the influence of gravity on the micromixer. Mixing efficiencies of greater than 92% are achieved using water and a 1011'density biological solvent as the mixing fluids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper presents the design and simulation of a novel passive micromixer. The micromixer consists of two inlet tanks, one mixing channel and two outlet channels. In order to maximise the mixing efficiency, the following considerations are made : (i) The inlet tanks are followed by a series of microchannels, in which the flow is split. The microchannels are arranged in an interdigital manner to  maximise the contact area between the two flows. (ii) The microchannels attached to the lower inlet tank have an upward slope while those attached to the upper tank have a downward slope. The higher-density flow is fed to the lower inlet tank and gets an upward velocity before entering the mixing channel. (iii) Two triangular barriers are placed within the mixing channel to impose chaotic advection and perturb the less-mixed flow along the top and bottom surfaces of the channel. (iv) Finally, two outlet channels are incorporated to discard the less-mixed flow. Three-dimensional simulations are carried out to evaluate the performance of the micromixer. Simulations are performed in the absence and presence of the gravitational force to analyse the influence of gravity on the micromixer. Mixing efficiencies of greater than 92 % are achieved using water and a low-density biological solvent as the mixing fluids.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a review of the recent trends and developments in non-optical biosensing platforms for lab-on- a-chip systems. This includes design considerations and applications of the non-optical biosensing platforms. The paper first categorizes the non-optical biosensors into four groups. The definition of each group together with a review of the reported works associated with the group are given. A performance analysis of different non-optical detection methods is also presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Miniaturization is being increasingly applied to biological and chemical analysis processes. Lab-on-a-chip systems are direct creation of the advancement in the miniaturization of these processes. They offer a host of exciting applications in several areas including clinical diagnostics, food and environmental analysis, and drug discovery and delivery studies. This paper reviews lab-on-a-chip systems from their components perspective. It provides a categorization of the standard functional components found in lab-on-a-chip devices together with an overview of the latest trends and developments related to lab-on-a-chip technologies and their application in nanobiotechnology. The functional components include: injector, transporter, preparator, mixer, reactor, separator, detector, controller, and power supply. The components are represented by appropriate symbols allowing designers to present their lab-on-a-chip products in a standard manner. Definition and role of each functional component are included and complemented with examples of existing work. Through the approach presented in this paper, it is hoped that modularity and technology transfer in lab-on-a-chip systems can be further facilitated and their application in nanobiotechnology be expanded.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent years have brought enormous progress in cell-based lab-on-a-chip technologies, allowing dynamic studies of cell death with an unprecedented accuracy. As interest in the microfabricated technologies for cell-based bioassays is rapidly gaining momentum, we highlight the most promising technologies that provide a new outlook for the rapid assessment of programmed and accidental cell death and are applicable in drug discovery, high-content drug screening, and personalized clinical diagnostics.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current practice of designing microfluidic Lab-on-a-Chip (LoCs) limits reusing designs and makes sharing tasks among researchers difficult. One way to achieve that objective is to borrow best practices from engineering. Also it takes a lot of skills to design LoCs. Design-by-assembly in which a LoC can be designed by configuring, laying out subsystems can help new researchers to develop custom chips. Flexible, reusable, and rapid-prototyping-feasible LoC designs can be achieved by fabricated modular microfluidic blocks. However, challenging problems still persist, which limit the usefulness of prefabricated blocks. We propose software microfluidic modules (SoftMABs) based design technique to solve issues fabricated modules face. By configuring SoftMABs, integrating them, the new assembly of SoftMABs can form a 3D LoC design ready to be prototyped. The proposed method can make designing a complex LoC less challenging, and collaborating among laboratories easier. We created SoftMABs and designed a custom microfluidic chip by assembling SoftMABs like LEGOs, dragging-and-dropping them. Later we reconfigured them - by replacing a SoftMAB with another module - to make a new LoC. We believe this computeraided method is an interesting and useful LoC design technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article describes the manufacturing and characterisation of plano-convex miniaturised lenses using a CO2 laser engraving process in PMMA substrates. The technique allows for lenses to be fabricated rapidly and in a reproducible manner at depths of over 200 µm and for lens diameters of more than 3 mm. Experimental characterisation of the lens focal lengths shows good correlation with theory. The plano-convex lenses have been successfully embedded into capillary microfluidic systems alongside planar microlenses, allowing for a significant reduction of ancillary optics without a loss of detection sensitivity when performing fluorescence measurements. Such technology provides a significant step forward towards the portability of fluorescence- or luminescence-based systems for biological/chemical analysis.