977 resultados para Nasal Septum


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Primary olfactory neurons situated in the nasal septum project axons within fascicles along a highly stereotypical trajectory en route to the olfactory bulb. The ventral fascicles make a distinct dorsovental turn at the rear of the septum so as to reach the olfactory bulb. In the present study we have used a brain and nasal septum coculture system to examine the role of target tissue on the peripheral trajectory of olfactory sensory axons. In cultures of isolated embryonic nasal septa, olfactory axons form numerous parallel fascicles that project caudally in the submucosa, as they do in vivo. The ventral axon fascicles in the septum, however, often fail to turn, and do not project dorsally towards the roof of the nasal cavity. The presence of olfactory bulb, cortical, or tectal tissue apposed to the caudal end of the septum rescued this phenotype, causing the ventral fascicles to follow a normal in vivo-like trajectory. Ectopic placements of the explants revealed that brain tissue is not tropic for olfactory axons but appears to maintain the peripheral trajectory of growing axons in the nasal septum. Although primary olfactory axons are able to penetrate into olfactory bulb in vitro, they only superficially enter cortical tissue, whereas they do not grow into tectal explants. The ability of axons to differentially grow into different brain regions was shown to be unrelated to the migratory behavior of olfactory ensheathing cells, indicating that olfactory axons are directly responsive to guidance cues in the brain. (C) 2004 Wiley Periodicals, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente trabalho teve por finalidade avaliar as alterações produzidas nos arcos dentárias superiores de pacientes submetidos à expansão rápida da maxila por meio de disjunção da sutura palatina mediana assistida cirurgicamente ERM-AC. A amostra utilizada para a realização deste estudo foi composta de 34 pares de modelos de gesso de 17 pacientes, sendo 6 do sexo masculino e 11 do sexo feminino. Para cada paciente foram preparados 2 pares de modelos obtidos em diferentes fases: inicial ,antes do procedimento operatório (T1) e três meses após o travamento do parafuso expansor (T2). O dispositivo expansor utilizado nesta amostra foi o disjuntor tipo Hyrax. O procedimento cirúrgico adotado foi a osteotomia nas paredes laterais da maxila sem o envolvimento da lâmina pterigóide, osteotomia da espinha nasal à linha média dental (incisivos centrais anteriores), separação da sutura palatina mediana por meio de cinzel e separação do septo nasal. O início da ativação ocorreu no 3o dia pós operatório sendo ¼ pela manhã e ¼ à noite, as ativações seguiram critérios clínicos para o controle da expansão. As medidas foram realizadas por meio da máquina de medição tridimensional (SAC) baseado nas alterações nos três planos vertical, sagital e transversal que ocorreram nos modelos de gesso. Os resultados mostraram que houve uma expansão estatisticamente significante na região dos caninos, primeiros prémolares, primeiros molares e segundos molares, respectivamente 6,03mm, 9,82mm, 8,66mm, 9,72mm e 5,67mm. As distâncias obtidas entre os incisivos centrais e laterais não se mostraram estatisticamente significantes, os valores obtidos foram respectivamente: 0,40mm e 4,12mm. As inclinações das coroas dentais para vestibular mostraram um comportamento assimétrico, pois nos primeiros molares os valores encontrados foram 6,890 (lado direito) e 9,560 (lado esquerdo) e para os primeiros prémolares os valores obtidos foram 3,260 para o lado direito (estatisticamente não significante) e 4,740 para o lado esquerdo. Avaliando a variável comprimento do arco maxilar, foi observada uma diminuição média entre os intervalos analisados T1 28,20 mm e T2 26,56 mm variando 1,64mm. Podemos concluir que a ERM-AC produziu uma expansão maxilar com inclinação vestibular da coroas dos dentes posteriores e diminuição no comprimento do arco maxilar, as outras variáveis analisadas não mostraram alterações estatisticamente significantes nos intervalos medidos.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este estudo avaliou as alterações produzidas nos arcos dentais superiores de pacientes submetidos à Expansão Rápida da Maxila Assistida Cirurgicamente (ERMAC). A amostra utilizada foi composta de 50 modelos de gesso superiores de 18 pacientes, sendo seis do sexo masculino e 12 do sexo feminino, com média de idade de 23,3 anos. Para cada paciente foram preparados três modelos de gesso obtidos em diferentes fases: Inicial, antes do procedimento operatório (T1); três meses pós-expansão (travamento do expansor) e momento da remoção do aparelho expansor tipo Hyrax e colocação da placa removível de acrílico para contenção (T2); seis meses pós-expansão e momento de remoção da placa de acrílico (T3). O dispositivo expansor utilizado foi o disjuntor tipo Hyrax. O procedimento cirúrgico adotado foi a osteotomia lateral da maxila sem o envolvimento da lâmina pterigóide, osteotomia da espinha nasal à linha média dental (incisivos centrais superiores), separação da sutura palatina mediana por meio de cinzel e separação do septo nasal. O início da ativação ocorreu no terceiro dia pós-operatório, sendo ¼ de volta pela manhã e ¼ à noite, sendo que as ativações seguiram critérios clínicos para o controle da expansão. As medidas foram realizadas por meio da máquina de medição tridimensional (SAC), baseando-se nas alterações nos três planos (vertical, sagital e transversal) que ocorreram nos modelos de gesso. Concluiu-se que: 1. Houve um aumento estatisticamente significante nas distâncias transversais em todos os grupos de dentes (de incisivos centrais até segundos molares) de T1 para T2, demonstrando a efetividade do tratamento. De T2 para T3 não houve diferença estatisticamente significante para nenhuma variável, indicando, assim, estabilidade após seis meses do término da ERMAC; 2. Houve um aumento estatisticamente significante nas inclinações dos primeiros e segundos molares dos lados direito e esquerdo e dos segundos pré-molares apenas do lado esquerdo, sugerindo um comportamento assimétrico dos dentes avaliados; 3. Houve um aumento na largura palatina nos intervalos analisados, com diferenças estatisticamente significantes entre T1 x T2 e T1 x T3; 4. Não foram observadas diferenças estatisticamente significantes na profundidade palatina nos intervalos analisados.(AU)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A cocaína é uma droga com ação estimulante no sistema nervoso central, extraída e refinada a partir da planta de coca (Erythroxylum coca). É característica por induzir o consumidor a um estado de hipervigilância reduzindo ao mesmo tempo, o cansaço e a fadiga. Este pó branco, cristalino, de sabor amargo, possui também um efeito anestésico local e vasoconstritor. As formas de apresentação mais comuns da droga são o cloridrato de cocaína e a cocaína crack. Esta droga destaca-se por ser o estimulante mais consumido na Europa com cerca de 3,4 milhões de consumidores estimados no ano de 2014. A prevalência do consumo desta droga em Portugal aumentou 0,3% de 2001, para 2012 na população geral (15-64 anos). Os estudos mais recentes em populações escolares (entre 2010 e 2011) evidenciaram, de um modo geral, o aumento da prevalência de consumo nesta população. Os efeitos adversos resultantes, tanto a nível físico como psíquico, são vários, sendo as manifestações orofaciais as que mais interferem na Qualidade de vida do toxicómano. As manifestações mais frequentes são as perfurações do septo nasal e palatino, bruxismo, gengivite, erosão dentária, xerostomia, cárie, lesões brancas atípicas e cefaleias em salva, tendo o Médico Dentista um papel importante no diagnóstico e tratamento destas lesões. A legislação, ao nível Europeu, sobre drogas procura uma uniformização das medidas aplicadas nos países membros, baseando-se no equilíbrio entre as sanções e o tratamento. Apesar das convenções das Nações Unidas sobre drogas limitarem o consumo de estupefacientes e substâncias psicotrópicas exclusivamente para fins médicos e científicos, cabe aos países signatários a liberdade de decisão das políticas a adoptar em matérias de infrações penais como a posse e o consumo ilegal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Community-associated methicillin-resistant Staphylococcus aureus (CA-MRSA) infections are emerging in southeast Queensland, Australia, but the incidence of carriage of CA-MRSA strains is unknown. The aim of this study was to assess the nasal carriage rate of S. aureus, including CA-MRSA strains, in the general adult population of southeast Queensland. 396 patients presenting to general practices in two Brisbane suburbs and 303 volunteers randomly selected from the electoral rolls in the same suburbs completed a medical questionnaire and had nasal swabs performed for S. aureus. All isolates of S. aureus underwent antibiotic susceptibility testing and single-nucleotide polymorphism (SNP) and binary typing, including determination of Panton–Valentine leukocidin (PVL). The nasal carriage rate of methicillin-susceptible S. aureus (MSSA) was 202/699 (28%), a rate similar to that found in other community-based nasal carriage studies. According to multivariate analysis, nasal carriage of S. aureus was associated with male sex, young adult age group and Caucasian ethnicity. Only two study isolates (one MSSA and one CA-MRSA) carried PVL. The nasal carriage rate of MRSA was low, at 5/699 (0.7%), and only two study participants (0.3%) had CA-MRSA strains. CA-MRSA is an emerging cause of infection in southeast Queensland, but as yet the incidence of carriage of CA-MRSA in the general community is low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: High-flow nasal cannulae (HFNC) create positive oropharyngeal airway pressure but it is unclear how their use affects lung volume. Electrical impedance tomography (EIT) allows assessment of changes in lung volume by measuring changes in lung impedance. Primary objectives were to investigate the effects of HFNC on airway pressure (Paw) and end-expiratory lung volume (EELV), and to identify any correlation between the two. Secondary objectives were to investigate the effects of HFNC on respiratory rate (RR), dyspnoea, tidal volume and oxygenation; and the interaction between body mass index (BMI) and EELV. Methods: Twenty patients prescribed HFNC post-cardiac surgery were investigated. Impedance measures, Paw, PaO2/FiO2 ratio, RR and modified Borg scores were recorded first on low flow oxygen (nasal cannula or Hudson face mask) and then on HFNC. Results: A strong and significant correlation existed between Paw and end-expiratory lung impedance (EELI) (r=0.7, p<0.001). Compared with low flow oxygen, HFNC significantly increased EELI by 25.6% (95% CI 24.3, 26.9) and Paw by 3.0 cmH2O (95% CI 2.4, 3.7). RR reduced by 3.4 breaths per minute (95% CI 1.7, 5.2) with HFNC use, tidal impedance variation increased by 10.5% (95% CI 6.1, 18.3) and PaO2/FiO2 ratio improved by 30.6 mmHg (95% CI 17.9, 43.3). HFNC improved subjective dyspnoea scoring (p=0.023). Increases in EELI were significantly influenced by BMI, with larger increases associated with higher BMIs (p<0.001). Conclusions: This study suggests that HFNC improve dyspnoea and oxygenation by increasing both EELV and tidal volume, and are most beneficial in patients with higher BMIs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Staphylococci are important pathogenic bacteria responsible for a range of diseases in humans. The most frequently isolated microorganisms in a hospital microbiology laboratory are staphylococci. The general classification of staphylococci divides them into two major groups; Coagulase-positive staphylococci (e.g. Staphylococcus aureus) and Coagulase-negative staphylococci (e.g. Staphylococcus epidermidis). Coagulase-negative staphylococcal (CoNS) isolates include a variety of species and many different strains but are often dominated by the most important organism of this group, S. epidermidis. Currently, these organisms are regarded as important pathogenic organisms causing infections related to prosthetic materials and surgical wounds. A significant number of S. epidermidis isolates are also resistant to different antimicrobial agents. Virulence factors in CoNS are not very clearly established and not well documented. S. epidermidis is evolving as a resistant and powerful microbe related to nosocomial infections because it has different properties which independently, and in combination, make it a successful infectious agent, especially in the hospital environment. Such characteristics include biofilm formation, drug resistance and the evolution of genetic variables. The purpose of this project was to develop a novel SNP genotyping method to genotype S. epidermidis strains originating from hospital patients and healthy individuals. High-Resolution Melt Analysis was used to assign binary typing profiles to both clinical and commensal strains using a new bioinformatics approach. The presence of antibiotic resistance genes and biofilm coding genes were also interrogated in these isolates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Surveillance programs and research for acute respiratory infections in remote Australian communities are complicated by difficulties in the storage and transport of frozen samples to urban laboratories for testing. This study assessed the sensitivity of a simple method for transporting nasal swabs from a remote setting for bacterial polymerase chain reaction (PCR) testing. Methods We sampled every individual who presented to a remote community clinic over a three week period in August at a time of low influenza and no respiratory syncytial virus activity. Two anterior nasal swabs were collected from each participant. The left nare specimen was mailed to the laboratory via routine postal services. The right nare specimen was transported frozen. Testing for six bacterial species was undertaken using real-time PCR. Results One hundred and forty participants were enrolled who contributed 150 study visits and paired specimens for testing. Respiratory illnesses accounted for 10% of the reasons for presentation. Bacteria were identified in 117 (78%) presentations for 110 (79.4%) individuals; Streptococcus pneumoniae and Haemophilus influenzae were the most common (each identified in 58% of episodes). The overall sensitivity for any bacterium detected in mailed specimens was 82.2% (95% CI 73.6, 88.1) compared to 94.8% (95% CI 89.4, 98.1) for frozen specimens. The sensitivity of the two methods varied by species identified. Conclusion The mailing of unfrozen nasal specimens from remote communities appears to influence the utility of the specimen for bacterial studies, with a loss in sensitivity for the detection of any species overall. Further studies are needed to confirm our finding and to investigate the possible mechanisms of effect. Clinical trial registration Australia and New Zealand Clinical Trials Registry Number: ACTRN12609001006235. Keywords: Respiratory bacteria; RT-PCR; Specimen transport; Laboratory methods

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improved biopharmaceutical delivery may be achieved via the use of biodegradable microspheres as delivery vehicles. Biodegradable microspheres offer the advantages of maintaining sustained protein release over time whilst simultaneously protecting the biopharmaceutical from degradation. Particle samples produced by ultrasonic atomization were studied in order to determine a feed stock capable of producing protein loaded poly-ε-caprolactone (PCL) particles suitable for nasal delivery (i.e., less than 20 μm). A 40 kHz atomization system was used with a 6 mm full wave atomization probe. The effect of solids percent, feed flow rate, volumetric ratio of the polymer stock to the protein stock, and protein concentration in the protein stock on particle size characteristics were determined. It was shown that feed stocks containing 100 parts of 0.5 or 1.0% w/v PCL in acetone with one part 100 mg ml -1 BSA and 15 mg ml -1 PVA produced particles with a mass moment diameter (D[4,3]) of 13.17 μm and 9.10 μm, respectively in addition to displaying high protein encapsulation efficiencies of 93 and 95%, respectively. The biodegradable PCL particles were shown to be able to deliver encapsulated protein in vitro under physiological conditions.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic rhinosinusitis is one of the most common chronic respiratory tract diseases affecting up to 15% of the adult population in the Western world. It may be perpetuated by factors predisposing to sinus ostial obstruction together with inflammatory changes in the sinus mucosa. Chronic rhinosinusitis is associated with asthma, and it may represent the same disease process. Chronic rhinosinusitis with nasal polyposis (CRSwNP) and asthma share also the characteristic inflammatory features and histopathologic feature of airway remodelling. Remodelling is considered as a key event in the pathogenesis of asthma. It is controlled by a delicate balance between the matrix metalloproteinases (MMPs) and their regulators. The purpose of the present study was to evaluate the microbiological findings, inflammatory features and MMP and tissue inhibitor of metalloproteinases-1 (TIMP-1) expression in CRSwNP. The results were related to the patient history, exposure to moisture and clinical outcome in order to find out possible explanations for the etiology and chronicity of CRSwNP. Bacterial culture results were similar in patients and in controls and do not explain the chronic course of CRSwNP. The presence of fungi seems to be more common in CRSwNP than chronic rhinosinusitis in general, and they should be actively searched for using microbiological as well as histological methods. Typical outdoor fungal species were found in nasal lavage samples taken from controls in the autumn but not in the winter, reflecting environmental exposure. Exposure to moisture was reported by 46% of the CRSwNP patients, which is in accordance to the Finnish general population. Exposed patients did not differ significantly from non-exposed subjects with regards to microbiological findings, tissue eosinophilia and clinical outcome. Significantly elevated levels of collagenase-2 (MMP-8) and interleukin (IL)-8 but not tumour necrosis factor-α were found in CRSwNP patients. In particular, the activation of mesenchymal-type MMP-8 but not polymorphonuclear-type MMP-8 was associated with elevated IL-8 levels. IL-8 and MMP-8 may form an inductive cytokine-proteinase cascade in CRSwNP pathogenesis and provide a target for novel therapies and a diagnostic tool for monitoring CRSwNP treatment. The proteolytic spectrum is different in eosinophilic and non-eosinophilic CRSwNP with the up-regulation of MMP-8 and MMP-9 in non-eosinophilic CRSwNP, suggesting different pathophysiology in these subgroups. The lack of MMP up-regulation was associated with a poor prognostic factor and worse clinical outcome, representing a possible synergic anti-inflammatory function of MMP-8 and MMP-9 in CRSwNP. This study provides new information about possible immunologic mechanisms in the pathogenesis of CRSwNP. The recently discovered anti-inflammatory/ defensive properties of MMP-8 and MMP-9 in animal models are reported for the first time in a clinical setting in human inflammatory diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Design and development of a piezoelectric polyvinylidene fluoride (PVDF) thin film based nasal sensor to monitor human respiration pattern (RP) from each nostril simultaneously is presented in this paper. Thin film based PVDF nasal sensor is designed in a cantilever beam configuration. Two cantilevers are mounted on a spectacle frame in such a way that the air flow from each nostril impinges on this sensor causing bending of the cantilever beams. Voltage signal produced due to air flow induced dynamic piezoelectric effect produce a respective RP. A group of 23 healthy awake human subjects are studied. The RP in terms of respiratory rate (RR) and Respiratory air-flow changes/alterations obtained from the developed PVDF nasal sensor are compared with RP obtained from respiratory inductance plethysmograph (RIP) device. The mean RR of the developed nasal sensor (19.65 +/- A 4.1) and the RIP (19.57 +/- A 4.1) are found to be almost same (difference not significant, p > 0.05) with the correlation coefficient 0.96, p < 0.0001. It was observed that any change/alterations in the pattern of RIP is followed by same amount of change/alterations in the pattern of PVDF nasal sensor with k = 0.815 indicating strong agreement between the PVDF nasal sensor and RIP respiratory air-flow pattern. The developed sensor is simple in design, non-invasive, patient friendly and hence shows promising routine clinical usage. The preliminary result shows that this new method can have various applications in respiratory monitoring and diagnosis.