133 resultados para Miniaturization
Resumo:
This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.
Resumo:
A indústria de semicondutores é um sector em permanente evolução tecnológica. A tendência de miniaturização e de otimização do espaço, a necessidade de produzir circuitos cada vez mais complexos, a tendência para o incremento do número de camadas em cada circuito integrado, são as condições necessárias para que a evolução tecnológica nesta área seja uma constante. Os processos ligados à produção de semicondutores estão também em permanente evolução, dada a pressão efetuada pelas necessidades acima expostas. Os equipamentos necessitam de uma crescente precisão, a qual tem que ser acompanhada de procedimentos rigorosos para que a qualidade atingida tenha sempre o patamar desejado. No entanto, a constante evolução nem sempre permite um adequado levantamento de todas as causas que estão na origem de alguns problemas detetados na fabricação de semicondutores. Este trabalho teve por objetivo efetuar um levantamento dos processos ligados ao fabrico de semicondutores a partir de uma pastilha de silício (wafer) previamente realizada, identificando para cada processo os possíveis defeitos introduzidos pelo mesmo, procurando inventariar as causas possíveis que possam estar na origem desse defeito e realizar procedimentos que permitam criar regras e procedimentos perfeitamente estabelecidos que permitam aprender com os erros e evitar que os mesmos problemas se possam vir a repetir em situações análogas em outros produtos de uma mesma família.
Resumo:
Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.
Resumo:
With the recent advances in technology and miniaturization of devices such as GPS or IMU, Unmanned Aerial Vehicles became a feasible platform for a Remote Sensing applications. The use of UAVs compared to the conventional aerial platforms provides a set of advantages such as higher spatial resolution of the derived products. UAV - based imagery obtained by a user grade cameras introduces a set of problems which have to be solved, e. g. rotational or angular differences or unknown or insufficiently precise IO and EO camera parameters. In this work, UAV - based imagery of RGB and CIR type was processed using two different workflows based on PhotoScan and VisualSfM software solutions resulting in the DSM and orthophoto products. Feature detection and matching parameters influence on the result quality as well as a processing time was examined and the optimal parameter setup was presented. Products of the both workflows were compared in terms of a quality and a spatial accuracy. Both workflows were compared by presenting the processing times and quality of the results. Finally, the obtained products were used in order to demonstrate vegetation classification. Contribution of the IHS transformations was examined with respect to the classification accuracy.
Resumo:
Introduction of technologies in the workplace have led to a dramatic change. These changes have come with an increased capacity to gather data about one’s working performance (i.e. productivity), as well as the capacity to track one’s personal responses (i.e. emotional, physiological, etc.) to this changing workplace environment. This movement of self-monitoring or self-sensing using diverse types of wearable sensors combined with the use of computing has been identified as the Quantified-Self. Miniaturization of sensors, reduction in cost and a non-stop increase in the computer power capacity has led to a panacea of wearables and sensors to track and analyze all types of information. Utilized in the personal sphere to track information, a looming question remains, should employers use the information from the Quantified-Self to track their employees’ performance or well-being in the workplace and will this benefit employees? The aim of the present work is to layout the implications and challenges associated with the use of Quantified-Self information in the workplace. The Quantified-Self movement has enabled people to understand their personal life better by tracking multiple information and signals; such an approach could allow companies to gather knowledge on what drives productivity for their business and/or well-being of their employees. A discussion about the implications of this approach will cover 1) Monitoring health and well-being, 2) Oversight and safety, and 3) Mentoring and training. Challenges will address the question of 1) Privacy and Acceptability, 2) Scalability and 3) Creativity. Even though many questions remain regarding their use in the workplace, wearable technologies and Quantified-Self data in the workplace represent an exciting opportunity for the industry and health and safety practitioners who will be using them.
Resumo:
Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Eletrónica Médica)
Resumo:
Silk fibroin (SF) is a commonly available natural biopolymer produced in specialized glands of arthropods, with a long history of use in textile production and also in health cares. The exceptional intrinsic properties of these fibers, such as self-assembly, machinability, biocompatibility, biodegradation or non-toxicity, offer a wide range of exciting opportunities [1]. It has long been recognized that silk can be a rich source of inspiration for designing new materials with tailored properties, enhanced performance and high added value for targeted applications, opening exciting new prospects in the domain of materials science and related technological fields, including bio-friendly integration, miniaturization and multifunctionalization. In recent years it has been demonstrated that fibroin is an excellent material for active components in optics and photonics devices. Progress in new technological fields such as optics, photonics and electronics are emerging [2,3]. The incorporation of polymer electrolytes as components of various devices (advanced batteries, smart windows, displays and supercapacitors) offers significant advantages with respect to traditional electrolytes, including enhanced reliability and improved safety. SF films are particularly attractive in this context. They have near-perfect transparency across the VIS range, surface flatness (together with outstanding mechanical robustness), ability to replicate patterned substrates and their thickness may be easily tailored from a few nanometers to hundreds of micrometers through spin-casting of a silk solution into subtract. Moreover, fibroin can be added to other biocomponents or salts in order to modify the biomaterial properties leading to optimized and total different functions. Preliminary tests performed with a prototype electrochromic device (ECD) incorporating SF films doped with lithium triflate and lithium tetrafluoroborate (LiTFSI and LiBF4, respectively) as electrolyte and WO3 as cathodic electrochromic layer, are extremely encouraging. Aiming to evaluate the performance of the ion conducting SF membranes doped with LiTFSI and LiBF4 (SF-Li), small ECDs with glass/ITO/WO3/SF-Li/CeO2-TiO2/ITO/glass configuration were assembled and characterized. The device exhibited, after 4500 cycles, the insertion of charge at -3.0 V reached –1.1 mC.cm-2 in 15 s. After 4500 cycles the window glass-staining, glass/ITO/WO3/Fibrin-Li salts electrolyte/CeO2-TiO2/ITO/glass configuration was reversible and featured a T 8 % at λ = 686 nm
Resumo:
Tese de Doutoramento em Engenharia Eletrónica e de Computadores.
Resumo:
Los requisitos de los dispositivos empleados en los nuevos sistemas de telecomunicaciones son: unas avanzadas prestaciones, reducido tamaño y bajo coste. Actualmente, se utilizan filtros basados en la tecnología SAW para trabajar a frecuencias de microondas. Dado los inconvenientes que presentan dicho tipo de filtros, se pretende substituirlos por filtros basados en tecnología BAW. La topología en escalera es hasta el momento la más extendida para diseñar estos filtros.
Resumo:
En este trabajo se describe la miniaturización del diseño de un desfasador de cuadratura mediante líneas de transmisión metamaterial en tecnología microstrip. Para conseguir la miniaturización del diseño se utiliza la topología Spiral Resonator (SR). Los desfasadores de cuadratura han sido diseñados, fabricados y medidos. Mediante este proceso se ha consiguido un dispositivo metamaterial que presenta una reducción de un 77% del tamaño respecto a las líneas convencionales.
Resumo:
En los últimos tiempos la telefonía móvil ha experimentado una reducción de los terminales gracias a la miniaturización de los filtros a frecuencias de microondas. Los filtros pasa banda más utilizados son los basados en la tecnología SAW, sin embargo son incompatibles con tecnologías de silicio y su comportamiento se degrada a frecuencias superiores de 3 GHz, por ello los estudios actuales se centran en la tecnología BAW. Las dos arquitecturas convencionales de filtros basados en resonadores BAW unidos eléctricamente son el ladder y lattice. Sin embargo, en este proyecto se estudiará la topología half lattice, la cual presenta un mejor comportamiento y unas dimensiones más reducidas. Para ello se obtendrán las ecuaciones de diseño del filtro, y con ellas se realizará la implementación a partir de la frecuencia central y el ancho de banda relativo.
Resumo:
Arsenic contamination of natural waters is a worldwide concern, as the drinking water supplies for large populations can have high concentrations of arsenic. Traditional techniques to detect arsenic in natural water samples can be costly and time-consuming; therefore, robust and inexpensive methods to detect arsenic in water are highly desirable. Additionally, methods for detecting arsenic in the field have been greatly sought after. This article focuses on the use of bacteria-based assays as an emerging method that is both robust and inexpensive for the detection of arsenic in groundwater both in the field and in the laboratory. The arsenic detection elements in bacteria-based bioassays are biosensor-reporter strains; genetically modified strains of, e.g., Escherichia coli, Bacillus subtilis, Staphylococcus aureus, and Rhodopseudomonas palustris. In response to the presence of arsenic, such bacteria produce a reporter protein, the amount or activity of which is measured in the bioassay. Some of these bacterial biosensor-reporters have been successfully utilized for comparative in-field analyses through the use of simple solution-based assays, but future methods may concentrate on miniaturization using fiberoptics or microfluidics platforms. Additionally, there are other potential emerging bioassays for the detection of arsenic in natural waters including nematodes and clams.
Resumo:
The Magnet Tracking System (MTS) is a minimally-invasive technique of continuous evaluation of gastrointestinal motility. In this study, MTS was used to analyse colonic propulsive dynamics and compare the transit of a magnetic pill with that of standard radio-opaque markers. MTS monitors the progress in real time of a magnetic pill through the gut. Ten men and 10 women with regular daily bowel movements swallowed this pill and 10 radio-opaque markers at 8 pm. Five hours of recordings were conducted during 2 following mornings. Origin, direction, amplitude and velocity of movements were analysed relative to space-time plots of the pill trajectory. Abdominal radiographs were taken to compare the progress of both pill and markers. The magnetic pill lay idle for 90% of its sojourn in the colon; its total retrograde displacement accounted for only 20% of its overall movement. Analysis of these movements showed a bimodal distribution of velocities: around 1.5 and 50 cm min(-1), the latter being responsible for 2/3 of distance traversed. There were more movements overall and more mass movements in males. Net hourly forward progress was greater in the left than right colon, and greater in males. The position of the magnetic pill correlated well with the advancement of markers. MTS showed patterns and propulsion dynamics of colonic segments with as yet unmet precision. Detailed analysis of slow and fast patterns of colonic progress makes it possible to specify the motility of colonic segments, and any variability in gender. Such analysis opens up promising avenues in studies of motility disorders.
Resumo:
BACKGROUND: Deep burn assessment made by clinical evaluation has an accuracy varying between 60% and 80% and will determine if a burn injury will need tangential excision and skin grafting or if it will be able to heal spontaneously. Laser Doppler Imaging (LDI) techniques allow an improved burn depth assessment but their use is limited by the time-consuming image acquisition which may take up to 6 min per image. METHODS: To evaluate the effectiveness and reliability of a newly developed full-field LDI technology, 15 consecutive patients presenting with intermediate depth burns were assessed both clinically and by FluxExplorer LDI technology. Comparison between the two methods of assessment was carried out. RESULTS: Image acquisition was done within 6 s. FluxEXPLORER LDI technology achieved a significantly improved accuracy of burn depth assessment compared to the clinical judgement performed by board certified plastic and reconstructive surgeons (P < 0.05, 93% of correctly assessed burns injuries vs. 80% for clinical assessment). CONCLUSION: Technological improvements of LDI technology leading to a decreased image acquisition time and reliable burn depth assessment allow the routine use of such devices in the acute setting of burn care without interfering with the patient's treatment. Rapid and reliable LDI technology may assist clinicians in burn depth assessment and may limit the morbidity of burn patients through a minimization of the area of surgical debridement. Future technological improvements allowing the miniaturization of the device will further ease its clinical application.
Resumo:
Numerous drug delivery systems (DDSs) can be used as intraocular tools to provide a sustained and calibrated release for a specific drug. Great progress has been made on the design, biocompatibility, bioavailability, and efficacy of DDSs. Although several of them are undergoing clinical trials, a few are already on the market and could be of a routine use in clinical practice. Moreover, miniaturization of the implants makes them less and less traumatic for the eye tissues and some DDSs are now able to target certain cells or tissues specifically. An overview of ocular implants with therapeutic application potentials is provided.