987 resultados para Mean deviation


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Birnbaum and Saunders (1969a) introduced a probability distribution which is commonly used in reliability studies For the first time based on this distribution the so-called beta-Birnbaum-Saunders distribution is proposed for fatigue life modeling Various properties of the new model including expansions for the moments moment generating function mean deviations density function of the order statistics and their moments are derived We discuss maximum likelihood estimation of the model s parameters The superiority of the new model is illustrated by means of three failure real data sets (C) 2010 Elsevier B V All rights reserved

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Laplace distribution is one of the earliest distributions in probability theory. For the first time, based on this distribution, we propose the so-called beta Laplace distribution, which extends the Laplace distribution. Various structural properties of the new distribution are derived, including expansions for its moments, moment generating function, moments of the order statistics, and so forth. We discuss maximum likelihood estimation of the model parameters and derive the observed information matrix. The usefulness of the new model is illustrated by means of a real data set. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE. To investigate the on-road driving performance of patients with glaucoma.

METHODS. The sample comprised 20 patients with glaucoma and 20 subjects with normal vision, all licensed drivers, matched for age and sex. Driving performance was tested over a 10-km route incorporating 55 standardized maneuvers and skills through residential and business districts of Halifax, Nova Scotia, Canada. Testing was conducted by a professional driving instructor and assessed by an occupational therapist certified in driver rehabilitation, masked to participant group membership and level of vision. Main outcome measures were total number of satisfactory maneuvers and skills, overall rating, and incidence of at-fault critical interventions (application of the dual brake and/or steering override by the driving instructor to prevent a potentially unsafe maneuver). Measures of visual function included visual acuity, contrast sensitivity, and visual fields (Humphrey Field Analyzer; Carl Zeiss Meditec, Inc., Dublin, CA; mean deviation [MD] and binocular Esterman points).

RESULTS. There was no significant difference between patients with glaucoma (mean MD = −1.7 dB [SD 2.2] and −6.5 dB [SD 4.9], better and worse eyes, respectively) and control subjects in total satisfactory maneuvers and skills (P = 0.65), or overall rating (P = 0.60). However, 12 (60%) patients with glaucoma had one or more at-fault critical interventions, compared with 4 (20%) control subjects (odds ratio = 6.00, 95% CI, 1.46–24.69; higher still after adjustment for age, sex, medications and driving exposure), the predominant reason being failure to see and yield to a pedestrian. In the glaucoma group, worse-eye MD was associated with the overall rating of driving (r = 0.66, P = 0.002).

CONCLUSIONS. This sample of patients with glaucoma with slight to moderate visual field impairment performed many real-world driving maneuvers safely. However, they were six times as likely as subjects with normal vision to have a driving instructor intervene for reasons suggesting difficulty with detection of peripheral obstacles and hazards and reaction to unexpected events.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE. To investigate the risk of falls and motor vehicle collisions (MVCs) in patients with glaucoma.

METHODS. The sample comprised 48 patients with glaucoma (mean visual field mean deviation [MD] in the better eye = −3.9 dB; 5.1 dB SD) and 47 age-matched normal control subjects, who were recruited from a university-based hospital eye care clinic and are enrolled in an ongoing prospective study of risk factors for falls, risk factors for MVCs, and on-road driving performance in glaucoma. Main outcome measures at baseline were previous self-reported falls and MVCs, and police-reported MVCs. Demographic and medical data were obtained. In addition, functional independence in daily living, physical activity level and balance were assessed. Clinical vision measures included visual acuity, contrast sensitivity, standard automated perimetry, useful field of view (UFOV), and stereopsis. Analyses of falls and MVCs were adjusted to account for the possible confounding effects of demographic characteristics, medications, and visual field impairment. MVC analyses were also adjusted for kilometers driven per week.

RESULTS. There were no significant differences between patients with glaucoma and control subjects with respect to number of systemic medical conditions, body mass index, functional independence, and physical activity level (P > 0.10). At baseline, 40 (83%) patients with glaucoma and 44 (94%) control subjects were driving. Compared with control subjects, patients with glaucoma were over three times more likely to have fallen in the previous year (odds ratio [OR]adjusted = 3.71; 95% CI, 1.14–12.05), over six times more likely to have been involved in one or more MVCs in the previous 5 years (ORadjusted = 6.62; 95% CI, 1.40–31.23), and more likely to have been at fault (ORadjusted = 12.44; 95% CI, 1.08–143.99). The strongest risk factor for MVCs in patients with glaucoma was impaired UFOV selective attention (ORadjusted = 10.29; 95% CI, 1.10–96.62; for selective attention >350 ms compared with ≤350 ms).

CONCLUSIONS. There is an increased risk of falls and MVCs in patients with glaucoma.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Conway-Maxwell Poisson (COMP) distribution as an extension of the Poisson distribution is a popular model for analyzing counting data. For the first time, we introduce a new three parameter distribution, so-called the exponential-Conway-Maxwell Poisson (ECOMP) distribution, that contains as sub-models the exponential-geometric and exponential-Poisson distributions proposed by Adamidis and Loukas (Stat Probab Lett 39:35-42, 1998) and KuAY (Comput Stat Data Anal 51:4497-4509, 2007), respectively. The new density function can be expressed as a mixture of exponential density functions. Expansions for moments, moment generating function and some statistical measures are provided. The density function of the order statistics can also be expressed as a mixture of exponential densities. We derive two formulae for the moments of order statistics. The elements of the observed information matrix are provided. Two applications illustrate the usefulness of the new distribution to analyze positive data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to assess the subjective visual vertical in patients with bilateral vestibular dysfunction and to propose a new method to analyze subjective visual vertical data in these patients. METHODS: Static subjective visual vertical tests were performed in 40 subjects split into two groups. Group A consisted of 20 healthy volunteers, and Group B consisted of 20 patients with bilateral vestibular dysfunction. Each patient performed six measurements of the subjective visual vertical test, and the mean values were calculated and analyzed. RESULTS: Analyses of the numerical values of subjective visual vertical deviations (the conventional method of analysis) showed that the mean deviation was 0.326 +/- 1.13 degrees in Group A and 0.301 +/- 1.87 degrees in Group B. However, by analyzing the absolute values of the subjective visual vertical (the new method of analysis proposed), the mean deviation became 1.35 +/- 0.48 degrees in Group A and 2.152 +/- 0.93 degrees in Group B. The difference in subjective visual vertical deviations between groups was statistically significant (p < 0.05) only when the absolute values and the range of deviations were considered. CONCLUSION: An analysis of the absolute values of the subjective visual vertical more accurately reflected the visual vertical misperception in patients with bilateral vestibular dysfunction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

For any continuous baseline G distribution [G. M. Cordeiro and M. de Castro, A new family of generalized distributions, J. Statist. Comput. Simul. 81 (2011), pp. 883-898], proposed a new generalized distribution (denoted here with the prefix 'Kw-G'(Kumaraswamy-G)) with two extra positive parameters. They studied some of its mathematical properties and presented special sub-models. We derive a simple representation for the Kw-Gdensity function as a linear combination of exponentiated-G distributions. Some new distributions are proposed as sub-models of this family, for example, the Kw-Chen [Z.A. Chen, A new two-parameter lifetime distribution with bathtub shape or increasing failure rate function, Statist. Probab. Lett. 49 (2000), pp. 155-161], Kw-XTG [M. Xie, Y. Tang, and T.N. Goh, A modified Weibull extension with bathtub failure rate function, Reliab. Eng. System Safety 76 (2002), pp. 279-285] and Kw-Flexible Weibull [M. Bebbington, C. D. Lai, and R. Zitikis, A flexible Weibull extension, Reliab. Eng. System Safety 92 (2007), pp. 719-726]. New properties of the Kw-G distribution are derived which include asymptotes, shapes, moments, moment generating function, mean deviations, Bonferroni and Lorenz curves, reliability, Renyi entropy and Shannon entropy. New properties of the order statistics are investigated. We discuss the estimation of the parameters by maximum likelihood. We provide two applications to real data sets and discuss a bivariate extension of the Kw-G distribution.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We study a five-parameter lifetime distribution called the McDonald extended exponential model to generalize the exponential, generalized exponential, Kumaraswamy exponential and beta exponential distributions, among others. We obtain explicit expressions for the moments and incomplete moments, quantile and generating functions, mean deviations, Bonferroni and Lorenz curves and Gini concentration index. The method of maximum likelihood and a Bayesian procedure are adopted for estimating the model parameters. The applicability of the new model is illustrated by means of a real data set.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To evaluate the retinal nerve fiber layer measurements with time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to test the diagnostic ability of both technologies in glaucomatous patients with asymmetric visual hemifield loss. Methods: 36 patients with primary open-angle glaucoma with visual field loss in one hemifield (affected) and absent loss in the other (non-affected), and 36 age-matched healthy controls had the study eye imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, California, USA) and 3 D OCT-1000 (Topcon, Tokyo, Japan). Peripapillary retinal nerve fiber layer measurements and normative classification were recorded. Total deviation values were averaged in each hemifield (hemifield mean deviation) for each subject. Visual field and retinal nerve fiber layer "asymmetry indexes" were calculated as the ratio between affected versus non-affected hemifields and corresponding hemiretinas. Results: Retinal nerve fiber layer measurements in non-affected hemifields (mean [SD] 87.0 [17.1] mu m and 84.3 [20.2] mu m, for TD and SD-OCT, respectively) were thinner than in controls (119.0 [12.2] mu m and 117.0 [17.7] mu m, P<0.001). The optical coherence tomography normative database classified 42% and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P=0.01). Retinal nerve fiber layer measurements were consistently thicker with TD compared to SD-OCT. Retinal nerve fiber layer thickness asymmetry index was similar in TD (0.76 [0.17]) and SD-OCT (0.79 [0.12]) and significantly greater than the visual field asymmetry index (0.36 [0.20], P<0.001). Conclusions: Normal hemifields of glaucoma patients had thinner retinal nerve fiber layer than healthy eyes, as measured by TD and SD-OCT. Retinal nerve fiber layer measurements were thicker with TD than SD-OCT. SD-OCT detected abnormal retinal nerve fiber layer thickness more often than TD-OCT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To review the clinical characteristics of patients with neuromyelitis optica (NMO) and to compare their visual outcome with those of patients with optic neuritis (ON) and multiple sclerosis (MS). Methods: Thirty-three patients with NMO underwent neuro-ophthalmic evaluation, including automated perimetry along with 30 patients with MS. Visual function in both groups was compared overall and specifically for eyes after a single episode of ON. Results: Visual function and average visual field (VF) mean deviation were significantly worse in eyes of patients with NMO. After a single episode of ON, the VF was normal in only 2 of 36 eyes of patients with NMO compared to 17 of 35 eyes with MS (P < 0.001). The statistical analysis indicated that after a single episode of ON, the odds ratio for having NMO was 6.0 (confidence interval [CI]: 1.6-21.9) when VF mean deviation was worse than -20.0 dB while the odds ratio for having MS was 16.0 (CI: 3.6-68.7) when better than -3.0 dB. Conclusion: Visual outcome was significantly worse in NMO than in MS. After a single episode of ON, suspicion of NMO should be raised in the presence of severe residual VF deficit with automated perimetry and lowered in the case of complete VF recovery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose: To investigate the rate of visual field and optic disc change in patients with distinct patterns of glaucomatous optic disc damage. Design: Prospective longitudinal study. Participants: A total of 131 patients with open-angle glaucoma with focal (n = 45), diffuse (n = 42), and sclerotic (n = 44) optic disc damage. Methods: Patients were examined every 4 months with standard automated perimetry (SAP, SITA Standard, 24-2 test, Humphrey Field Analyzer, Carl Zeiss Meditec, Dublin, CA) and confocal scanning laser tomography (CSLT, Heidelberg Retina Tomograph, Heidelberg Engineering GmbH, Heidelberg, Germany) for a period of 4 years. During this time, patients were treated according to a predefined protocol to achieve a target intraocular pressure (IOP). Rates of change were estimated by robust linear regression of visual field mean deviation (MD) and global optic disc neuroretinal rim area with follow-up time. Main Outcome Measures: Rates of change in MD and rim area. Results: Rates of visual field change in patients with focal optic disc damage (mean -0.34, standard deviation [SD] 0.69 dB/year) were faster than in patients with sclerotic (mean - 0.14, SD 0.77 dB/year) and diffuse (mean + 0.01, SD 0.37 dB/year) optic disc damage (P = 0.003, Kruskal-Wallis). Rates of optic disc change in patients with focal optic disc damage (mean - 11.70, SD 25.5 x 10(-3) mm(2)/year) were faster than in patients with diffuse (mean -9.16, SD 14.9 x 10(-3) mm(2)/year) and sclerotic (mean -0.45, SD 20.6 x 10(-3) mm(2)/year) optic disc damage, although the differences were not statistically significant (P = 0.11). Absolute IOP reduction from untreated levels was similar among the groups (P = 0.59). Conclusions: Patients with focal optic disc damage had faster rates of visual field change and a tendency toward faster rates of optic disc deterioration when compared with patients with diffuse and sclerotic optic disc damage, despite similar IOP reductions during follow-up. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2012; 119: 294-303 (C) 2012 by the American Academy of Ophthalmology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To investigate the possible effect of aspherical or yellow tinted intraocular lens (IOL) on contrast sensitivity and blue-on-yellow perimetry. METHODS: This prospective randomized bilateral double-masked clinical study included 52 patients with visually significant bilateral cataracts divided in two groups; 25 patients (50 eyes) received aspherical intraocular lens in one eye and spherical intraocular lens in the fellow eye; and 27 patients (54 eyes) received ultraviolet and blue light filter (yellow tinted) IOL implantation in one eye and acrylic ultraviolet filter IOL in the fellow eye. The primary outcome measures were contrast sensitivity and blue-on-yellow perimetry values (mean deviation [MD] and pattern standard deviation [PSD]) investigated two years after surgery. The results were compared intra-individually. RESULTS: There was a statistically significant between-group (aspherical and spherical intraocular lens) difference in contrast sensitivity under photopic conditions at 12 cycles per degree and under mesopic conditions at all spatial frequencies. There were no between-group significant differences (yellow tinted and clear intraocular lens) under photopic or mesopic conditions. There was no statistically significant difference between all intraocular lens in MD or PSD. CONCLUSION: Contrast sensitivity was better under mesopic conditions with aspherical intraocular lens. Blue-on-yellow perimetry did not appear to be affected by aspherical or yellow tinted intraocular lens. Further studies with a larger sample should be carried out to confirm or not that hypotheses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coupled-Cluster-Theorie (CC) ist in der heutigen Quantenchemie eine der erfolgreichsten Methoden zur genauen Beschreibung von Molekülen. Die in dieser Arbeit vorgestellten Ergebnisse zeigen, daß neben den Berechnungen von Energien eine Reihe von Eigenschaften wie Strukturparameter, Schwingungsfrequenzen und Rotations-Schwingungs-Parameter kleiner und mittelgrofler Moleküle zuverlässig und präzise vorhergesagt werden können. Im ersten Teil der Arbeit wird mit dem Spin-adaptierten Coupled-Cluster-Ansatz (SA-CC) ein neuer Weg zur Verbesserung der Beschreibung von offenschaligen Systemen vorgestellt. Dabei werden zur Bestimmung der unbekannten Wellenfunktionsparameter zusätzlich die CC-Spingleichungen gelöst. Durch dieses Vorgehen wird gewährleistet, daß die erhaltene Wellenfunktion eine Spineigenfunktion ist. Die durchgeführte Implementierung des Spin-adaptierten CC-Ansatzes unter Berücksichtigung von Einfach- und Zweifachanregungen (CCSD) für high-spin Triplett-Systeme wird ausführlich erläutert. Im zweiten Teil werden CC-Additionsschemata vorgestellt, die auf der Annahme der Additivität von Elektronenkorrelations- und Basissatzeffekten basieren. Die etablierte Vorgehensweise, verschiedene Beiträge zur Energie mit an den Rechenaufwand angepassten Basissätzen separat zu berechnen und aufzusummieren, wird hier auf Gradienten und Kraftkonstanten übertragen. Für eine Beschreibung von Bindungslängen und harmonischen Schwingungsfrequenzen mit experimenteller Genauigkeit ist die Berücksichtigung von Innerschalenkorrelationseffekten sowie Dreifach- und Vierfachanregungen im Clusteroperator der Wellenfunktion nötig. Die Basissatzkonvergenz wird dabei zusätzlich mit Extrapolationsmethoden beschleunigt. Die quantitative Vorhersage der Bindungslängen von 17 kleinen Molekülen, aufgebaut aus Atomen der ersten Langperiode, ist so mit einer Genauigkeit von wenigen Hundertstel Pikometern möglich. Für die Schwingungsfrequenzen dieser Moleküle weist das CC-Additionsschema basierend auf den berechneten Kraftkonstanten im Vergleich zu experimentellen Ergebnissen einen mittleren absoluten Fehler von 3.5 cm-1 und eine Standardabweichung von 2.2 cm-1 auf. Darüber hinaus werden zur Unterstützung von experimentellen Untersuchungen berechnete spektroskopische Daten einiger größerer Moleküle vorgelegt. Die in dieser Arbeit vorgestellten Untersuchungen zur Isomerisierung von Dihalogensulfanen XSSX (X= F, Cl) oder die Berechnung von Struktur- und Rotations-Schwingungs-Parametern für die Moleküle CHCl2F und CHClF2 zeigen, daß bereits störungstheoretische CCSD(T)-Näherungsmethoden qualitativ gute Vorhersagen experimenteller Resultate liefern. Desweiteren werden Diskrepanzen von experimentellen und berechneten Bindungsabständen bei den Molekülen Borhydrid- und Carbenylium durch die Berücksichtigung des elektronischen Beitrages zum Trägheitsmoment beseitigt.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: The aim of this study is to implement augmented reality in real-time image-guided interstitial brachytherapy to allow an intuitive real-time intraoperative orientation. METHODS AND MATERIALS: The developed system consists of a common video projector, two high-resolution charge coupled device cameras, and an off-the-shelf notebook. The projector was used as a scanning device by projecting coded-light patterns to register the patient and superimpose the operating field with planning data and additional information in arbitrary colors. Subsequent movements of the nonfixed patient were detected by means of stereoscopically tracking passive markers attached to the patient. RESULTS: In a first clinical study, we evaluated the whole process chain from image acquisition to data projection and determined overall accuracy with 10 patients undergoing implantation. The described method enabled the surgeon to visualize planning data on top of any preoperatively segmented and triangulated surface (skin) with direct line of sight during the operation. Furthermore, the tracking system allowed dynamic adjustment of the data to the patient's current position and therefore eliminated the need for rigid fixation. Because of soft-part displacement, we obtained an average deviation of 1.1 mm by moving the patient, whereas changing the projector's position resulted in an average deviation of 0.9 mm. Mean deviation of all needles of an implant was 1.4 mm (range, 0.3-2.7 mm). CONCLUSIONS: The developed low-cost augmented-reality system proved to be accurate and feasible in interstitial brachytherapy. The system meets clinical demands and enables intuitive real-time intraoperative orientation and monitoring of needle implantation.