963 resultados para MRI quantitative


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Otto-von-Guericke-Universität Magdeburg, Fakultät für Informatik, Dissertation, 2016

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The histopathological counterpart of white matter hyperintensities is a matter of debate. Methodological and ethical limitations have prevented this question to be elucidated. We want to introduce a protocol applying state-of-the-art methods in order to solve fundamental questions regarding the neuroimaging-neuropathological uncertainties comprising the most common white matter hyperintensities [WMHs] seen in aging. By this protocol, the correlation between signal features in in situ, post mortem MRI-derived methods, including DTI and MTR and quantitative and qualitative histopathology can be investigated. We are mainly interested in determining the precise neuroanatomical substrate of incipient WMHs. A major issue in this protocol is the exact co-registration of small lesion in a tridimensional coordinate system that compensates tissue deformations after histological processing. The protocol is based on four principles: post mortem MRI in situ performed in a short post mortem interval, minimal brain deformation during processing, thick serial histological sections and computer-assisted 3D reconstruction of the histological sections. This protocol will greatly facilitate a systematic study of the location, pathogenesis, clinical impact, prognosis and prevention of WMHs. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work is to provide a quantitative method for analysis of the concentration of superparamagnetic iron oxide nanoparticles (SPION), determined by means of ferromagnetic resonance (FMR), with the nanoparticles coupled to a specific antibody (AC133), and thus to express the antigenic labeling evidence for the stem cells C D133(+). The FMR efficiency and sensitivity were proven adequate for detecting and quantifying the low amounts of iron content in the C D133(+) cells (similar to 6.16 x 10(5) pg in the volume of 2 mu l containing 4.5 x 1011 SPION). The quantitative method led to the result of 1.70 x 10(-13) mol of Fe (9.5 pg), or 7.0 x 10(6) nanoparticles per cell. For the quantification analysis via the FMR technique it was necessary to carry out a preliminary quantitative visualization of iron oxide-labeled cells in order to ensure that the nanoparticles coupled to the antibodies are indeed tied to the antigen at the stem cell surface and that the cellular morphology was conserved, as proof of the validity of this method. The quantitative analysis by means of FMR is necessary for determining the signal intensity for the study of molecular imaging by means of magnetic resonance imaging (MRI).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Chronic aortic valve disease (AVD) is characterized by progressive accumulation of interstitial myocardial fibrosis (MF). However, assessment of MF accumulation has only been possible through histologic analyses of endomyocardial biopsies. We sought to evaluate contrast-enhanced magnetic resonance imaging (ce-MRI) as a noninvasive method to identify the presence of increased MF in patients with severe AVD. Methods Seventy patients scheduled to undergo aortic valve replacement surgery were examined by cine and ce-MRI in a 1.5-T scanner. Cine images were used for the assessment of left ventricular (LV) volumes, mass, and function. Delayed-enhancement images were used to characterize the regions of MF. In addition, histologic analyses of myocardial samples obtained during aortic valve replacement surgery were used for direct quantification of interstitial MF. Ten additional subjects who died of noncardiac causes served as controls for the quantitative histologic analyses. Results Interstitial MF determined by histopathologic analysis was higher in patients with AVID than in controls (2.7% +/- 2.0% vs 0.6% +/- 0.2%, P =.001). When compared with histopathologic results, ce-MRI demonstrated a sensitivity of 74%, a specificity of 81%, and an accuracy of 76% to identify AVD patients with increased interstitial MF There was a significant inverse correlation between interstitial MF and LV ejection fraction (r = -0.67, P <.0001). Accordingly, patients with identifiable focal regions of MF by ce-MRI exhibited worse LV systolic function than those without MF (45% +/- 14% vs 65% +/- 14%, P <.0001). Conclusions Contrast-enhanced MRI allows for the noninvasive detection of focal regions of MF in patients with severe AVD. Moreover, patients with identifiable MF by ce-MRI exhibited worse LV functional parameters. (Am Heart J 2009; 157:361-8.)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study we present a novel automated strategy for predicting infarct evolution, based on MR diffusion and perfusion images acquired in the acute stage of stroke. The validity of this methodology was tested on novel patient data including data acquired from an independent stroke clinic. Regions-of-interest (ROIs) defining the initial diffusion lesion and tissue with abnormal hemodynamic function as defined by the mean transit time (MTT) abnormality were automatically extracted from DWI/PI maps. Quantitative measures of cerebral blood flow (CBF) and volume (CBV) along with ratio measures defined relative to the contralateral hemisphere (r(a)CBF and r(a)CBV) were calculated for the MTT ROIs. A parametric normal classifier algorithm incorporating these measures was used to predict infarct growth. The mean r(a)CBF and r(a)CBV values for eventually infarcted MTT tissue were 0.70 +/-0.19 and 1.20 +/-0.36. For recovered tissue the mean values were 0.99 +/-0.25 and 1.87 +/-0.71, respectively. There was a significant difference between these two regions for both measures (P

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The aim of this study was to examine minor physical anomalies and quantitative measures of the head and face in patients with psychosis vs healthy controls. Methods: Based on a comprehensive prevalence study of psychosis, we recruited 310 individuals with psychosis and 303 controls. From this sample, we matched 180 case-control pairs for age and sex. Individual minor physical anomalies and quantitative measures related to head size and facial height and depth were compared within the matched pairs. Based on all subjects, we examined the specificity of the findings by comparing craniofacial summary scores in patients with nonaffective or affective psychosis and controls. Results: The odds of having a psychotic disorder were increased in those with wider skull bases (odds ratio [OR], 1.40; 95% confidence interval [CI], 1.02-1.17), smaller lower-facial heights (glabella to subnasal) (OR, 0.57; 95% CI, 0.44-0.75), protruding ears (OR, 1.72; 95% CI, 1.05-2.82), and shorter (OR, 2.29; 95% CI, 1.37-3.82) and wider (OR, 2.28; 95% CI, 1.43-3.65) palates. Compared with controls, those with psychotic disorder had skulls that were more brachycephalic. These differences were found to distinguish patients with nonaffective and affective psychoses from controls. Conclusions: Several of the features that differentiate patients from controls relate to the development of the neuro-basicranial complex and the adjacent temporal and frontal lobes. Future research should examine both the temporal lobe and the middle cranial fossa to reconcile our anthropomorphic findings and the literature showing smaller temporal lobes in patients with schizophrenia. Closer attention to the skull base may provide clues to the nature and timing of altered brain development in patients with psychosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of support vector machine classification (SVM) to combined information from magnetic resonance imaging (MRI) and [F18]fluorodeoxyglucose positron emission tomography (FDG-PET) has been shown to improve detection and differentiation of Alzheimer's disease dementia (AD) and frontotemporal lobar degeneration. To validate this approach for the most frequent dementia syndrome AD, and to test its applicability to multicenter data, we randomly extracted FDG-PET and MRI data of 28 AD patients and 28 healthy control subjects from the database provided by the Alzheimer's Disease Neuroimaging Initiative (ADNI) and compared them to data of 21 patients with AD and 13 control subjects from our own Leipzig cohort. SVM classification using combined volume-of-interest information from FDG-PET and MRI based on comprehensive quantitative meta-analyses investigating dementia syndromes revealed a higher discrimination accuracy in comparison to single modality classification. For the ADNI dataset accuracy rates of up to 88% and for the Leipzig cohort of up to 100% were obtained. Classifiers trained on the ADNI data discriminated the Leipzig cohorts with an accuracy of 91%. In conclusion, our results suggest SVM classification based on quantitative meta-analyses of multicenter data as a valid method for individual AD diagnosis. Furthermore, combining imaging information from MRI and FDG-PET might substantially improve the accuracy of AD diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Interventional catheterization is being increasingly used for relief of residual lesions in congenital heart disease. Exact anatomical imaging is crucial in the planning of an intervention. This can be provided non-invasively and without radiation by contrast-enhanced MR angiography (CEMRA). Aim: To evaluate the accuracy of the measurements of the vessels obtained by CEMRA in comparison to those obtained by conventional X-ray angiography (CXA). Methods: Retrospective blinded measurement of the diameters of aorta and pulmonary arteries on the CEMRA and CXA images, in the same locations. Comparison of the results by Pearson correlation and by calculating the limits of agreement. Results: Twenty-one children with congenital heart disease, mean age 5.6 +- 5.2 years, weight 21.1 +- 18.4 kg, underwent CEMRA and catheterization for assessment or treatment of a residual lesion. The time interval between the CEMRA and the CXA examination was 2.6 +- 2.3 months. A total of 98 measurements, 37 of the aorta and 61 of the pulmonary arteries were performed on the images obtained by each technique. The correlation between CEMRA and CXA measurements was excellent, r = 0.97, p < 0.0001. The mean difference between the two techniques was 0.018 +- 1.1mm; the limits of agreement were -2.14 and +2.18mm. Similar agreement was found for measures of the aorta (r +- 0.97, mean difference 0.20 = 1.08 mm) and of the pulmonary arteries (r +- 0.97, mean difference 0.048 = 0.89 mm). Conclusions: CEMRA provide accurate quantitative anatomical information, which highly agrees with CXA data, and can therefore be used for planning interventional catheterization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Quantitative measures of degree of lumbar spinal stenosis (LSS) such as antero-posterior diameter of the canal or dural sac cross sectional area vary widely and do not correlate with clinical symptoms or results of surgical decompression. In an effort to improve quantification of stenosis we have developed a grading system based on the morphology of the dural sac and its contents as seen on T2 axial images. The grading comprises seven categories ranging form normal to the most severe stenosis and takes into account the ratio of rootlet/CSF content. Material and methods: Fifty T2 axial MRI images taken at disc level from twenty seven symptomatic lumbar spinal stenosis patients who underwent decompressive surgery were classified into seven categories by five observers and reclassified 2 weeks later by the same investigators. Intra- and inter-observer reliability of the classification were assessed using Cohen's and Fleiss' kappa statistics, respectively. Results: Generally, the morphology grading system itself was well adopted by the observers. Its success in application is strongly influenced by the identification of the dural sac. The average intraobserver Cohen's kappa was 0.53 ± 0.2. The inter-observer Fleiss' kappa was 0.38 ± 0.02 in the first rating and 0.3 ± 0.03 in the second rating repeated after two weeks. Discussion: In this attempt, the teaching of the observers was limited to an introduction to the general idea of the morphology grading system and one example MRI image per category. The identification of the dimension of the dural sac may be a difficult issue in absence of complete T1 T2 MRI image series as it was the case here. The similarity of the CSF to possibly present fat on T2 images was the main reason of mismatch in the assignment of the cases to a category. The Fleiss correlation factors of the five observers are fair and the proposed morphology grading system is promising.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Contexte et but de l'étude: Les fractures du triquetrum sont les deuxièmes fractures des os du carpe en fréquence, après celles du scaphoïde. Elles représentent environ 3.5% de toutes les lésions traumatiques du poignet, et résultent le plus souvent d'une chute de sa hauteur avec réception sur le poignet en hyper-extension. Leur mécanisme physiopathologique reste débattu. La première théorie fut celle de l'avulsion ligamentaire d'un fragment osseux dorsal. Puis, Levy et coll. ainsi que Garcia-Elias ont successivement suggéré que ces fractures résultaient plutôt d'une impaction ulno-carpienne. De nombreux ligaments (intrinsèques et extrinsèques du carpe) s'insèrent sur les versants palmaires et dorsaux du triquetrum. Ces ligaments jouent un rôle essentiel dans le maintien de la stabilité du carpe. Bien que l'arthro-IRM du poignet soit l'examen de référence pour évaluer ces ligaments, Shahabpour et coll. ont récemment démontré leur visibilité en IRM tridimensionnelle (volumique) après injection iv. de produit de contraste (Gadolinium). L'atteinte ligamentaire associée aux fractures dorsales du triquetrum n'a jusqu'à présent jamais été évalué. Ces lésions pourraient avoir un impact sur l'évolution et la prise en charge de ces fractures. Les objectifs de l'étude étaient donc les suivants: premièrement, déterminer l'ensemble des caractéristiques des fractures dorsales du triquetrum en IRM, en mettant l'accent sur les lésions ligamentaires extrinsèques associées; secondairement, discuter les différents mécanismes physiopathologiques (i.e. avulsion ligamentaire ou impaction ulno-carpienne) de ces fractures d'après nos résultats en IRM. Patients et méthodes: Ceci est une étude rétrospective multicentrique (CHUV, Lausanne; Hôpital Cochin, AP-HP, Paris) d'examens IRM et radiographies conventionnelles du poignet. A partir de janvier 2008, nous avons recherché dans les bases de données institutionnelles les patients présentant une fracture du triquetrum et ayant bénéficié d'une IRM volumique du poignet dans un délai de six semaines entre le traumatisme et l'IRM. Les examens IRM ont été effectués sur deux machines à haut champ magnétique (3 Tesla) avec une antenne dédiée et un protocole d'acquisition incluant une séquence tridimensionnelle isotropique (« 3D VIBE ») après injection iv. de produit de contraste (Gadolinium). Ces examens ont été analysés par deux radiologues ostéo-articulaires expérimentés. Les mesures ont été effectuées par un troisième radiologue ostéo-articulaire. En ce qui concerne l'analyse qualitative, le type de fracture du triquetrum (selon la classification de Garcia-Elias), la distribution de l'oedème osseux post- traumatique, ainsi que le nombre et la distribution des lésions ligamentaires extrinsèques associées ont été évalués. Pour l'analyse quantitative, l'index du processus de la styloïde ulnaire (selon la formule de Garcia-Elias), le volume du fragment osseux détaché du triquetrum, et la distance séparant ce fragment osseux du triquetrum ont été mesurés.