286 resultados para MAMMOGRAPHY
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
BACKGROUND:The Swiss breast cancer screening pilot programme was conducted in 3 districts of theFrench-speaking canton of Vaud (ca. 300,000 resident women) between October 1993 and January 1999.Women aged 50 to 69 were invited by mail every 2 years for a free of charge screening mammography (doubleview, multiple reading). This first ever-organised cancer screening programme in Switzerland showed thefeasibility and acceptability of this kind of public health intervention in the liberal Swiss healthcare system, whichwas the main objective of the pilot programme. This mammographic screening programme was extended to thewhole canton in 1999, and contributed to the implementation of similar programmes in 2 neighbouring cantons. OBJECTIVE:To appraise the use, the quality and the effectiveness of the Swiss screening pilot programme. METHODS:About 15,000 women (aged 50-69) were enrolled. Logistic regression analyses were performedseparately to identify determinants of initial and subsequent attendance. Standard indicators of quality,effectiveness and impact of the programme were assessed and compared with European recommendations. Tothis intent, linkage with data from the Vaud Cancer Registry was performed. RESULTS:About half the target population was screened at least once during the pilot trial. Participation washigher among Swiss than foreigners, among widowed or married women than among single, divorced or separatedones. Attendance also increased with age and decreasing distance between residence and the dedicatedscreening centre. Apart from Swiss citizenship, socio-demographic factors were not associated with reattendance.Intensity of prior recruitment, outcome of previous screening test (positive vs. negative) and indicators of women'shealth behaviour (time of last mammography prior to initial screen, smoking status) were the main determinants ofreattendance. Programme performance and quality indicators were, overall, in line with European Guidelines. Theywere overall more favourable among 60-69 than 50-59 year-olds and improved over time. CONCLUSION:The objectives of the pilot programme were met. Even if participation should increase in order toreach European standards, performance indicators overall met quality requirements. Ways to improve screeninguse, quality and effectiveness were devised and taken into account for the generalisation of the programme.
Resumo:
A method of objectively determining imaging performance for a mammography quality assurance programme for digital systems was developed. The method is based on the assessment of the visibility of a spherical microcalcification of 0.2 mm using a quasi-ideal observer model. It requires the assessment of the spatial resolution (modulation transfer function) and the noise power spectra of the systems. The contrast is measured using a 0.2-mm thick Al sheet and Polymethylmethacrylate (PMMA) blocks. The minimal image quality was defined as that giving a target contrast-to-noise ratio (CNR) of 5.4. Several evaluations of this objective method for evaluating image quality in mammography quality assurance programmes have been considered on computed radiography (CR) and digital radiography (DR) mammography systems. The measurement gives a threshold CNR necessary to reach the minimum standard image quality required with regards to the visibility of a 0.2-mm microcalcification. This method may replace the CDMAM image evaluation and simplify the threshold contrast visibility test used in mammography quality.
Resumo:
Quality assurance programmes are becoming a common practice in the field of mammography. At the present time several recommendations exist and different test objects are used to optimize this radiological procedure. The goal of this study was to check if geographically distant centres using different quality control procedures were comparable when using a common objective way of assessing image quality. The results show that consensus still needs to be found among radiologists to reach a satisfactory level of harmony between patient doses and image quality in Europe.
Resumo:
The shape of the energy spectrum produced by an x-ray tube has a great importance in mammography. Many anode-filtration combinations have been proposed to obtain the most effective spectrum shape for the image quality-dose relationship. On the other hand, third generation synchrotrons such as the European Synchrotron Radiation Facility in Grenoble are able to produce a high flux of monoenergetic radiation. It is thus a powerful tool to study the effect of beam energy on image quality and dose in mammography. An objective method was used to evaluate image quality and dose in mammography with synchrotron radiation and to compare them to standard conventional units. It was performed systematically in the energy range of interest for mammography through the evaluation of a global image quality index and through the measurement of the mean glandular dose. Compared to conventional mammography units, synchrotron radiation shows a great improvement of the image quality-dose relationship, which is due to the beam monochromaticity and to the high intrinsic collimation of the beam, which allows the use of a slit instead of an anti-scatter grid for scatter rejection.
Resumo:
Context: The debate about the balance of risks and benefits of mammography screening has prompted a comprehensive review by an independent panel in the UK. However, the panel's remit did not cover the important economic dimension of breast cancer screening. Methods: The life histories of two cohort studies of 50-year-old women, who would be eligible within the National Health Service (NHS) breast screening programme (NHSBSP), were simulated over 35 years, using a life table approach. One cohort participant was offered screening at age 50 and triennially thereafter until age 70, assuming 75% attendance, while the other received no screening. Based on the findings from the panel's report, the cost-effectiveness of the NHSBSP was assessed for various scenarios of screening effect on breast cancer incidence (base case scenario: screening advances diagnosis by 5 years; 10% incidence reduction after screening stops).
Resumo:
In many European countries, image quality for digital x-ray systems used in screening mammography is currently specified using a threshold-detail detectability method. This is a two-part study that proposes an alternative method based on calculated detectability for a model observer: the first part of the work presents a characterization of the systems. Eleven digital mammography systems were included in the study; four computed radiography (CR) systems, and a group of seven digital radiography (DR) detectors, composed of three amorphous selenium-based detectors, three caesium iodide scintillator systems and a silicon wafer-based photon counting system. The technical parameters assessed included the system response curve, detector uniformity error, pre-sampling modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE). Approximate quantum noise limited exposure range was examined using a separation of noise sources based upon standard deviation. Noise separation showed that electronic noise was the dominant noise at low detector air kerma for three systems; the remaining systems showed quantum noise limited behaviour between 12.5 and 380 µGy. Greater variation in detector MTF was found for the DR group compared to the CR systems; MTF at 5 mm(-1) varied from 0.08 to 0.23 for the CR detectors against a range of 0.16-0.64 for the DR units. The needle CR detector had a higher MTF, lower NNPS and higher DQE at 5 mm(-1) than the powder CR phosphors. DQE at 5 mm(-1) ranged from 0.02 to 0.20 for the CR systems, while DQE at 5 mm(-1) for the DR group ranged from 0.04 to 0.41, indicating higher DQE for the DR detectors and needle CR system than for the powder CR phosphor systems. The technical evaluation section of the study showed that the digital mammography systems were well set up and exhibiting typical performance for the detector technology employed in the respective systems.
Resumo:
BACKGROUND: Various centralised mammography screening programmes have shown to reduce breast cancer mortality at reasonable costs. However, mammography screening is not necessarily cost-effective in every situation. Opportunistic screening, the predominant screening modality in several European countries, may under certain circumstances be a cost-effective alternative. In this study, we compared the cost-effectiveness of both screening modalities in Switzerland. METHODS: Using micro-simulation modelling, we predicted the effects and costs of biennial mammography screening for 50-69 years old women between 1999 and 2020, in the Swiss female population aged 30-70 in 1999. A sensitivity analysis on the test sensitivity of opportunistic screening was performed. RESULTS: Organised mammography screening with an 80% participation rate yielded a breast cancer mortality reduction of 13%. Twenty years after the start of screening, the predicted annual breast cancer mortality was 25% lower than in a situation without screening. The 3% discounted cost-effectiveness ratio of organised mammography screening was euro11,512 per life year gained. Opportunistic screening with a similar participation rate was comparably effective, but at twice the costs: euro22,671-24,707 per life year gained. This was mainly related to the high costs of opportunistic mammography and frequent use of imaging diagnostics in combination with an opportunistic mammogram. CONCLUSION: Although data on the performance of opportunistic screening are limited, both opportunistic and organised mammography screening seem effective in reducing breast cancer mortality in Switzerland. However, for opportunistic screening to become equally cost-effective as organised screening, costs and use of additional diagnostics should be reduced.
Resumo:
[Abstract] Reading volume and mammography screening performance appear positively correlated. Performance was compared across organised Swiss screening programmes, which target relatively small populations. Except for accreditation of 2nd readers radiologists (restrictive vs non-restrictive strategy), Swiss programmes have similar screening regimen/procedures and duration, which maximises comparability. Variation in performance was explored in order to improve mammography practice and optimise screening performance. Indicators of quality and effectiveness were evaluated for about 200,000 screens performed over 4 screening rounds in the 3 longest-standing Swiss cantonal programmes (of Vaud, Geneva and Valais). Interval cancers were identified by linkage with cancer registries records. Most European standards of performance were met with a favourable cancer stage shift. Several performance indicators showed substantial variation across programmes. In subsequent rounds, compared with programmes (Vaud and Geneva) which accredited few 2nd readers to increase their individual reading volume, proportions of in situ lesions and of small cancers (? 1cm) were one third lower and halved, respectively, and the proportion of advanced lesions (stage II+) nearly 50% higher in the programme without a restrictive selection strategy. Discrepancy in second-year proportional incidence of interval cancers appears to be multicausal. Differences in performance could partly be explained by a selective strategy for 2nd readers and a prior experience in service screening, but not by the levels of opportunistic screening and programme attendance. This study provides clues for enhancing mammography screening performance in low-volume Swiss programmes.