987 resultados para Liquid infusion techniques


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The paper presents methods for measurement of convective heat transfer distributions in a cold flow, supersonic blowdown wind tunnel. The techniques involve use of the difference between model surface temperature and adiabatic wall temperature as the driving temperature difference for heat transfer and no active heating or cooling of the test gas or model is required. Thermochromic liquid crystals are used for surface temperature indication and results presented from experiments in a Mach 3 flow indicate that measurements of the surface heat transfer distribution under swept shock wave boundary layer interactions can be made. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Post-processing a finite element solution is a well-known technique, which consists in a recalculation of the originally obtained quantities such that the rate of convergence increases without the need for expensive remeshing techniques. Postprocessing is especially effective in problems where better accuracy is required for derivatives of nodal variables in regions where Dirichlet essential boundary condition is imposed strongly. Consequently such an approach can be exceptionally good in modelling of resin infiltration under quasi steady-state assumption by remeshing techniques and with explicit time integration, because only the free-front normal velocities are necessary to advance the resin front to the next position. The new contribution is the post-processing analysis and implementation of the freeboundary velocities of mesolevel infiltration analysis. Such implementation ensures better accuracy on even coarser meshes, which in consequence reduces the computational time also by the possibility of employing larger time steps.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Fine-needle aspiration cytology (FNAC) of serous membrane effusions may fulfil a challenging role in the diagnostic analysis of both primary and metastatic disease. From this perspective, liquid-based cytology (LBC) represents a feasible and reliable method for empowering the performance of ancillary techniques (ie, immunocytochemistry and molecular testing) with high diagnostic accuracy. METHODS: In total, 3171 LBC pleural and pericardic effusions were appraised between January 2000 and December 2013. They were classified as negative for malignancy (NM), suspicious for malignancy (SM), or positive for malignancy (PM). RESULTS: The cytologic diagnoses included 2721 NM effusions (2505 pleural and 216 pericardic), 104 SM effusions (93 pleural and 11 pericardic), and 346 PM effusions (321 pleural and 25 pericardic). The malignant pleural series included 76 unknown malignancies (36 SM and 40 PM effusions), 174 metastatic lesions (85 SM and 89 PM effusions), 14 lymphomas (3 SM and 11 PM effusions), 16 mesotheliomas (5 SM and 11 SM effusions), and 3 myelomas (all SM effusions). The malignant pericardic category included 20 unknown malignancies (5 SM and 15 PM effusions), 15 metastatic lesions (1 SM and 14 PM effusions), and 1 lymphoma (1 PM effusion). There were 411 conclusive immunocytochemical analyses and 47 molecular analyses, and the authors documented 88% sensitivity, 100% specificity, 98% diagnostic accuracy, 98% negative predictive value, and 100% positive predictive value for FNAC. CONCLUSIONS: FNAC represents a primary diagnostic tool for effusions and a reliable approach with which to determine the correct follow-up. Furthermore, LBC is useful for ancillary techniques, such as immunocytochemistry and molecular analysis, with feasible diagnostic and predictive utility.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: Comparison of doxorubicin uptake, leakage and spatial regional blood flow, and drug distribution was made for antegrade, retrograde, combined antegrade and retrograde isolated lung perfusion, and pulmonary artery infusion by endovascular inflow occlusion (blood flow occlusion), as opposed to intravenous administration in a porcine model. METHODS: White pigs underwent single-pass lung perfusion with doxorubicin (320 mug/mL), labeled 99mTc-microspheres, and Indian ink. Visual assessment of the ink distribution and perfusion scintigraphy of the perfused lung was performed. 99mTc activity and doxorubicin levels were measured by gamma counting and high-performance liquid chromatography on 15 tissue samples from each perfused lung at predetermined localizations. RESULTS: Overall doxorubicin uptake in the perfused lung was significantly higher (P = .001) and the plasma concentration was significantly lower (P < .0001) after all isolated lung perfusion techniques, compared with intravenous administration, without differences between them. Pulmonary artery infusion (blood flow occlusion) showed an equally high doxorubicin uptake in the perfused lung but a higher systemic leakage than surgical isolated lung perfusion (P < .0001). The geometric coefficients of variation of the doxorubicin lung tissue levels were 175%, 279%, 226%, and 151% for antegrade, retrograde, combined antegrade and retrograde isolated lung perfusion, and pulmonary artery infusion by endovascular inflow occlusion (blood flow occlusion), respectively, compared with 51% for intravenous administration (P = .09). 99mTc activity measurements of the samples paralleled the doxorubicin level measurements, indicating a trend to a more heterogeneous spatial regional blood flow and drug distribution after isolated lung perfusion and blood flow occlusion compared with intravenous administration. CONCLUSIONS: Cytostatic lung perfusion results in a high overall doxorubicin uptake, which is, however, heterogeneously distributed within the perfused lung.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The isolation of polyphenolic compounds from an infusion of the Brazilian plant Davilla elliptica (Dilleniaceae), used as tea by virtue of its digestive properties, is described. An improved preparative HPLC method was used in order to isolate pure polyphenols from the complex mixture. Liquid-liquid extraction and solid-phase extraction were employed to minimise the interference of polymeric compounds and to provide an enriched fraction of the compounds of interest. The identification of the isolated compounds was performed using analytical HPLC as well as direct injection electrospray ionisation ion trap tandem mass spectrometry (ESI-IT-MS/MS). The high flavonoid content suggests that D. elliptica may be a promising source of compounds to produce natural phytomedicines. Copyright (C) 2007 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A rapid analytical approach suitable to achieve a comprehensive characterization of the compounds present in the infusion prepared from the leaves of Byrsonima fagifolia Niedenzu (Malpighiaceae), a Brazilian plant used as an infusion to treat gastric disorders, was developed. The method was based on high-performance liquid chromatography coupled to electrospray negative ionisation multistage ion trap mass spectrometry (HPLC/ESI-ITMSn). The main ions in the ESI-ITMS spectra were attributed to a quinic acid core containing from one to five galloyl units. Quercetin derivatives containing one and two sugar moieties as well as galloyl esterification were also detected. These results indicated that HPLC/ESI-ITMSn is easily applicable to infusions of this plant and allows the rapid and direct identification of these compounds in crude plant extracts. Copyright (C) 2007 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A fast and reliable method, based on high-performance liquid chromatography coupled to electrospray ionization ion trap tandem mass spectrometry (HPLC/ESI-ITMS), was developed to investigate the infusion prepared from the leaves of Byrsonima crassa Niedenzu (Malpighiaceae), a native plant used in Brazil against gastric disorders. The use of on-line reverse-phase HPLC/ESI-ITMS allowed separation of three major classes of compounds and identification of over 20 very polar compounds characterized as galloylquinic acids, proanthocyanidins, and flavonoid glycosides, as well as the dimeric flavonoid amentoflavone and minor amounts of galloyl hexose and galloyl saccharose. This approach provided data that will allow establishment of a method for a future standardization of the infusion. Copyright (C) 2005 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

[EN]Until recently, sample preparation was carried out using traditional techniques, such as liquidliquid extraction (LLE), that use large volumes of organic solvents. Solid-phase extraction (SPE) uses much less solvent than LLE, although the volume can still be significant. These preparation methods are expensive, time-consuming and environmentally unfriendly. Recently, a great effort has been made to develop new analytical methodologies able to perform direct analyses using miniaturised equipment, thereby achieving high enrichment factors, minimising solvent consumption and reducing waste. These microextraction techniques improve the performance during sample preparation, particularly in complex water environmental samples, such as wastewaters, surface and ground waters, tap waters, sea and river waters. Liquid chromatography coupled to tandem mass spectrometry (LC/MS/MS) and time-of-flight mass spectrometric (TOF/MS) techniques can be used when analysing a broad range of organic micropollutants. Before separating and detecting these compounds in environmental samples, the target analytes must be extracted and pre-concentrated to make them detectable. In this work, we review the most recent applications of microextraction preparation techniques in different water environmental matrices to determine organic micropollutants: solid-phase microextraction SPME, in-tube solid-phase microextraction (IT-SPME), stir bar sorptive extraction (SBSE) and liquid-phase microextraction (LPME). Several groups of compounds are considered organic micropollutants because these are being released continuously into the environment. Many of these compounds are considered emerging contaminants. These analytes are generally compounds that are not covered by the existing regulations and are now detected more frequently in different environmental compartments. Pharmaceuticals, surfactants, personal care products and other chemicals are considered micropollutants. These compounds must be monitored because, although they are detected in low concentrations, they might be harmful toward ecosystems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Micro-scale, two-phase flow is found in a variety of devices such as Lab-on-a-chip, bio-chips, micro-heat exchangers, and fuel cells. Knowledge of the fluid behavior near the dynamic gas-liquid interface is required for developing accurate predictive models. Light is distorted near a curved gas-liquid interface preventing accurate measurement of interfacial shape and internal liquid velocities. This research focused on the development of experimental methods designed to isolate and probe dynamic liquid films and measure velocity fields near a moving gas-liquid interface. A high-speed, reflectance, swept-field confocal (RSFC) imaging system was developed for imaging near curved surfaces. Experimental studies of dynamic gas-liquid interface of micro-scale, two-phase flow were conducted in three phases. Dynamic liquid film thicknesses of segmented, two-phase flow were measured using the RSFC and compared to a classic film thickness deposition model. Flow fields near a steadily moving meniscus were measured using RSFC and particle tracking velocimetry. The RSFC provided high speed imaging near the menisci without distortion caused the gas-liquid interface. Finally, interfacial morphology for internal two-phase flow and droplet evaporation were measured using interferograms produced by the RSFC imaging technique. Each technique can be used independently or simultaneously when.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An experiment was conceived in which we monitored degradation of GlcDGD. Independent of the fate of the [14C]glucosyl headgroup after hydrolysis from the glycerol backbone, the 14C enters the aqueous or gas phase whereas the intact lipid is insoluble and remains in the sediment phase. Total degradation of GlcDGD then is obtained by combining the increase of radioactivity in the aqueous and gaseous phases. We chose two different sediment to perform this experiment. One is from microbially actie surface sediment sampled in February 2010 from the upper tidal flat of the German Wadden Sea near Wremen (53° 38' 0N, 8° 29' 30E). The other one is deep subsurface sediments recovered from northern Cascadia Margin during Integrated Ocean Drilling Program Expedition 311 [site U1326, 138.2 meters below seafloor (mbsf), in situ temperature 20 °C, water depth 1,828 m. We performed both alive and killed control experiments for comparison. Surface and subsurface sediment slurry were incubated in the dark at in situ temperature, 4 °C and 20 °C for 300 d, respectively. The sterilized slurry was stored at 20 °C. All incubations were carried out under N2 headspace to ensure anaerobic conditions. The sampling frequency was high during the first half-month, i.e., after 1, 2, 7, and 14 d; thereafter, the sediment slurry was sampled every 2 months. At each time point, samples were taken in triplicate for radioactivity measurements. After 300 d of incubation, no significant changes of radioactivity in the aqueous phase were detected. This may be the result of either the rapid turnover of released [14C] glucose or the relatively high limit of detection caused by the slight solubility (equivalent to 2% of initial radioactivity) of GlcDGD in water. Therefore, total degradation of GlcDGD in the dataset was calculated by combining radioactivity of DIC, CH4, and CO2, leading to a minimum estimate.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Agricultural crops can be damaged by funguses, insects, worms and other organisms that cause diseases and decrease the yield of production. The effect of these damaging agents can be reduced using pesticides. Among them, triazole compounds are effective substances against fungus; for example, Oidium. Nevertheless, it has been detected that the residues of these fungicides in foods as well as in derivate products can affect the health of the consumers. Therefore, the European Union has established several regulations fixing the maximum residue of pesticide levels in a wide range of foods trying to assure the consumer safety. Hence, it is very important to develop adequate methods to determine these pesticide compounds. In most cases, gas or liquid chromatographic (GC, LC) separations are used in the analysis of the samples. But firstly, it is necessary to use proper sample treatments in order to preconcentrate and isolate the target analytes. To reach this aim, microextraction techniques are very effective tools; because allow to do both preconcentration and extraction of the analytes in one simple step that considerably reduces the source of errors. With these objectives, two remarkable techniques have been widely used during the last years: solid phase microextraction (SPME) and liquid phase microextraction (LPME) with its different options. Both techniques that avoid the use or reduce the amount of toxic solvents are convenient coupled to chromatographic equipments providing good quantitative results in a wide number of matrices and compounds. In this work simple and reliable methods have been developed using SPME and ultrasound assisted emulsification microextraction (USAEME) coupled to GC or LC for triazole fungicides determination. The proposed methods allow confidently determine triazole concentrations of μg L‐1 order in different fruit samples. Chemometric tools have been used to accomplish successful determinations. Firstly, in the selection and optimization of the variables involved in the microextraction processes; and secondly, to overcome the problems related to the overlapping peaks. Different fractional factorial designs have been used for the screening of the experimental variables; and central composite designs have been carried out to get the best experimental conditions. Trying to solve the overlapping peak problems multivariate calibration methods have been used. Parallel Factor Analysis 2 (PARAFAC2), Multivariate Curve Resolution (MCR) and Parallel Factor Analysis with Linear Dependencies (PARALIND) have been proposed, the adequate algorithms have been used according to data characteristics, and the results have been compared. Because its occurrence in Basque Country and its relevance in the production of cider and txakoli regional wines the grape and apple samples were selected. These crops are often treated with triazole compounds trying to solve the problems caused by the funguses. The peel and pulp from grape and apple, their juices and some commercial products such as musts, juice and cider have been analysed showing the adequacy of the developed methods for the triazole determination in this kind of fruit samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

studies have shown that rate of propofol infusion may influence the predicted propofol concentration at the effect site (Es). The aim of this study was to evaluate the Es predicted by the Marsh pharmacokinetic model (ke0 0.26min(-1)) in loss of consciousness during fast or slow induction. the study included 28 patients randomly divided into two equal groups. In slow induction group (S), target-controlled infusion (TCI) of propofol with plasma, Marsh pharmacokinetic model (ke0 0.26min(-1)) with target concentration (Tc) at 2.0-μg.mL(-1) were administered. When the predicted propofol concentration at the effect site (Es) reached half of Es value, Es was increased to previous Es + 1μg.mL(-1), successively, until loss of consciousness. In rapid induction group (R), patients were induced with TCI of propofol with plasma (6.0μg.ml(-1)) at Es, and waited until loss of consciousness. in rapid induction group, Tc for loss of consciousness was significantly lower compared to slow induction group (1.67±0.76 and 2.50±0.56μg.mL(-1), respectively, p=0.004). the predicted propofol concentration at the effect site for loss of consciousness is different for rapid induction and slow induction, even with the same pharmacokinetic model of propofol and the same balance constant between plasma and effect site.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The flavonoids present in sugarcane (Saccharum officinarum) extracts were analyzed by liquid chromatography - mass spectrometry (LC-MS), and a study of the fragmentation patterns of selected flavonoids was conducted using orthogonal acceleration time-of-flight electrospray ionization mass spectrometry (ESI-oa-ToF MS). Seven C- and O-glycosylflavones were identified in the extracts, namely, schaftoside, isoschaftoside, luteolin-8-C-(rhamnosylglucoside), vitexin, orientin, tricin-7-O-neohesperidoside and tricin-7-O-glucoside. Of these, five were identified in the absence of direct comparison with their respective standards. The described method also permitted the differentiation of the 6-C and 8-C isomeric flavones, schaftoside and isoschaftoside. The combination of fragmentation data and exact mass measurement showed to be complimentary to the HPLC-UV-MS techniques previously utilized for isomers discrimination in sugarcane studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently semi-empirical models to estimate flow boiling heat transfer coefficient, saturated CHF and pressure drop in micro-scale channels have been proposed. Most of the models were developed based on elongated bubbles and annular flows in the view of the fact that these flow patterns are predominant in smaller channels. In these models, the liquid film thickness plays an important role and such a fact emphasizes that the accurate measurement of the liquid film thickness is a key point to validate them. On the other hand, several techniques have been successfully applied to measure liquid film thicknesses during condensation and evaporation under macro-scale conditions. However, although this subject has been targeted by several leading laboratories around the world, it seems that there is no conclusive result describing a successful technique capable of measuring dynamic liquid film thickness during evaporation inside micro-scale round channels. This work presents a comprehensive literature review of the methods used to measure liquid film thickness in macro- and micro-scale systems. The methods are described and the main difficulties related to their use in micro-scale systems are identified. Based on this discussion, the most promising methods to measure dynamic liquid film thickness in micro-scale channels are identified. (C) 2009 Elsevier Inc. All rights reserved.